Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROSTATIC PROBES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Three point method to characterize low-pressure electronegative discharges using electrostatic probe

Electrostatic probe measurements for low-pressure inductively coupled SF{sub 6} plasmas are performed. From the current-voltage (I-V) curves of probe, the saturation currents of the positive ions and electrons and the electron temperature are measured. The electronegativity and the negative ion density are deduced by using the ratios of these parameters at three adjacent pressure points. The positive ion density is calculated by the orbital-motion-limited theory, and the electron temperatures are given either by the slope of the I-V curves or by the electron energy distribution function with the second derivative of I-V curves. The variations in the charged species density with pressure and power are investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An ion thruster internal discharge chamber electrostatic probe diagnostic technique using a high-speed probe positioning system

Extensive resources have been allocated to diagnose and minimize lifetime-limiting factors in gridded ion thrusters. While most of this effort has focused on grid erosion, results from wear tests indicate that discharge cathode erosion may also play an important role in limiting the lifetime of ring-cusp ion thrusters proposed for future large flagship missions. The detailed characterization of the near-cathode discharge plasma is essential for mitigating discharge cathode erosion. However, severe difficulty is encountered when attempting to measure internal discharge plasma parameters during thruster operation with conventional probing techniques. These difficulties stem from the high-voltage, high-density discharge cathode plume, which is a hostile environment for probes. A method for interrogating the discharge chamber plasma of a working ion thruster over a two-dimensional grid is demonstrated. The high-speed axial reciprocating probe positioning system is used to minimize thruster perturbation during probe insertion and to reduce heating of the probe. Electrostatic probe measurements from a symmetric double Langmuir probe are presented over a two-dimensional spatial array in the near-discharge cathode assembly region of a 30-cm-diameter ring-cusp ion thruster. Electron temperatures, 2-5 eV, and number density contours, with a maximum of 8x10{sup 12} cm{sup -3} on centerline, are measured. These data provide detailed electron temperature and number density contours which, when combined with plasma potential measurements, may shed light on discharge cathode erosion processes and the effect of thruster operating conditions on erosion rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Surface Charge Distribution Mapping Using an Electrostatic Probe

Undesired accumulation of charge on dielectric materials causing electrostatic discharges can be an issue in pulsed power systems and electrical systems in general. As such, an understanding of surface charge distribution, charge accumulation, and decay is required. An in-house no-contact electrostatic probe designed with a 2 mm resolution was fabricated to measure and map surface charge distribution. Designed as a contactless instrument, the probe consisting of a metal rod and low leakage amplifier circuit probes the electric potential near the surface. A scan of the surface then provides the raw data, a potential distribution. The actual probe response - i.e., the surface charge to voltage transfer function, is accounted for in post-processing. This is accomplished via an Inverse Wien Filter - a technique often applied in image processing - to deconvolve the probe response from the measured data. A commercially available electrostatic probe, the Trek 341B meter with a 3455ET probe, capable of measuring +/- 20 kV was compared to the in- house probe that is designed to cover a wider range from +/- 35 kV. A resolution better than the simple probe resolution is achieved through the distribution’s scanning voltage method and deconvolution. Applying repeated scans, surface charge decay was tracked on various polymer materials to determine the material and environment dependence; materials included were PA6, PTFE, and others. As an example of material dependence, samples charged to 20 kV at 65% humidity experience full charge decay in approximately 45 seconds for PA5 (152 mm dia.), while it took about 100 times longer for PTFE (51 mm dia.) to observe the same decay/redistribution of charge.

36 MATERIALS SCIENCE↗

Electrostatic probe disruption of drift waves in magnetized microdischarges

Ultrahigh speed images of ExB discharges are collected during electrostatic probing of magnetized microdischarges. Two azimuthally separated floating micro-Langmuir probes inserted into an axisymmetric microscale magnetically confined plasma are used to characterize azimuthal drift waves. The images reveal features associated with probe intrusion, showing how the electrostatic probes may disrupt the otherwise coherent azimuthal waves. The resulting wave dispersion calculated from the probe signals is consistent with the disruptions seen in the images. These images demonstrate how probe measurements of fluctuations and turbulence, even when probe dimensions are much smaller than characteristic discharge scales, must be interpreted with caution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficiency of Tungsten Dust Collection of Different Types of Dust Particles by Electrostatic Probe

Formation of dust particles and clusters is observed in almost every modern thermonuclear facility. Accumulation of dust in the next generation thermonuclear installations can dramatically affect the plasma parameters and lead to the accumulation of unacceptably large amounts of tritium. Experiments on collection of dust particles by a model of electrostatic probe developed for collection of metallic dust at ITER are described in the article. Experiments on the generation of tungsten dust consisting of flakes formed during the destruction of tungsten layers formed on the walls of the plasma chamber sputtered from the surface of the tungsten target by plasma ions were conducted. The nature of dust degassing at elevated temperatures and the behavior of dust in an electric field were studied. The results obtained are compared with the results of the experiments with dust consisting of crystal particles of simple geometric shapes. The effectiveness of collection of both types of dust using the model of an electrostatic probe is determined.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Potential structure of discharge plasma inside liquid directly measured by an electrostatic probe

Potential structures of a discharge plasma inside a liquid are investigated by an electrostatic probe measurement. The time evolution of radial profiles of the floating potential for the plasma inside liquid reveals that the dominant negative charges in the plasma are the negative ion species such as OH{sup -} and O{sub 2}{sup -} rather than electrons. In addition, a positive potential gradient exists at the plasma-liquid interface due to the presence of an electrical double layer which is caused by the separation of low-mass positive ion of H{sup +} and high-mass negative ions of OH{sup -} and O{sub 2}{sup -} near the plasma-liquid interface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Automated electrostatic probe device of high resolution and accuracy

In this work, an automated apparatus for driving single electrostatic probes and acquiring the plasma-related data has been designed and fabricated. The voltage range of the present system is ±110 V with an adjustable voltage step as low as 3 mV. Voltage and current measurements are carried out with high resolution and high accuracy circuits, both based on 16 bit analog-to-digital converters. The code embedded in a micro-controller, schedules the operation of the device and transfers the experimental data to a personal computer. The modular design of the system makes possible its modification and thus increases its adaptability to different plasma setups. Finally, the reliable operation of the entire device is confirmed by tests in Electron Cyclotron Resonance plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Micro-Particles as Electrostatic Probes for Plasma Sheath Diagnostic

An interesting aspect in the research of complex (dusty) plasmas is the experimental study of the interaction of micro-particles of different sizes with the surrounding plasma for diagnostic purpose. In the plasma micro-disperse particles are negatively charged and confined in the sheath. The particles are trapped by an equilibrium of gravity, electric field force and ion drag force. From the behavior, local electric fields can be determined, e.g. particles are used as electrostatic probes. In combination with additional measurements of the plasma parameters with Langmuir probes and thermal probes as well as by comparison with an analytical sheath model, the structure of the sheath can be described. In the present work we focus on the behavior of micro-particles of different sizes and several plasma parameters e.g. the gas pressure and the rf-power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detailed plasma potential measurements in a radio-frequency expanding plasma obtained from various electrostatic probes

On-axis plasma potential measurements have been made with an emissive probe in a low pressure (0.044 Pa) rf expanding plasma containing an ion beam. The beam is detected with a retarding field energy analyzer (RFEA), and is seen to disappear at high pressure (0.39 Pa). The emissive probe measurements are in very good agreement with corresponding measurements made with two separate RFEAs, and the results indicate that the floating potential of the strongly emitting probe gives an accurate measure of the plasma potential under the present conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Perturbations induced by electrostatic probe in the discharge of Hall thrusters

Emissive and Langmuir probes are two widely used plasma diagnostic techniques that, when used properly, give access to a wide range of information on the plasma’s ions and electrons. We show here that their use in small and medium power Hall thrusters produces large perturbations in the discharge characteristics. Potential measurements performed by both probes and non-invasive Laser Induced Fluorescence (LIF) spectroscopy highlight significant discrepancies in the discharge profile. This phenomenon is observed both in the 200 W and the 1.5 kW-class thrusters. In order to have a better understanding of these perturbations, ion velocity distribution functions are acquired by LIF spectroscopy at different positions in the smaller thruster, with and without the probes. Emissive probes are shown to produce the biggest perturbation, shifting the acceleration region upstream. The probe insertion is also shown to have significant effect on both the average discharge current, increasing it by as much as 30%, and its harmonic content in both amplitude and spectrum. These perturbations appear as the probe tip passes a threshold located between 0 and 5 mm downstream of the thruster exit plane.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of an electron beam in a high density plasma via an electrostatic probe

Here, an electron beam is detected by a 1D floating potential probe array in a relatively high density (10 12 –10 13 cm -3 ) and low temperature (~5 eV) plasma of the Magnetic Reconnection Experiment. Clear perturbations in the floating potential profile by the electron beam are observed. Based on the floating potential profile and a current balance equation to the probe array tips, the effective width of the electron beam is determined, from which we determine the radial and toroidal beam current density profiles. After the profile of the electron beam is specified from the measured beam current, we demonstrate the consistency of the current balance equation and the location of the perturbation is also in agreement with field line mapping. No significant broadening of the electron beam is observed after the beam propagates for tens of centimeters through the high density plasma. These results prove that the field line mapping is, in principle, possible in high density plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detection of an electron beam in a high density plasma via an electrostatic probe

An electron beam is detected by a 1D floating potential probe array in a relatively high density (10e12 - 10e13 cm-3) and low temperature (~ 5 eV) plasma of the Magnetic Reconnection Experiment (MRX). Clear perturbations in the floating potential profile by the electron beam are observed. Based on the floating potential profile and a current balance equation to the probe array tips, the effective width of the electron beam is determined, from which we determine the radial and toroidal beam current density profiles. After the profile of the electron beam is specified from the measured beam current, we demonstrate the consistency of the current balance equation and the location of the perturbation is also in agreement with field line mapping. No significant broadening of the electron beam is observed after the beam propagates for tens of centimeters through the high density plasma. These results prove that the field line mapping is, in principle, possible in high density plasmas.

field line mapping↗

Quantification of in-contact probe-sample electrostatic forces with dynamic atomic force microscopy

Here, atomic force microscopy (AFM) methods utilizing resonant mechanical vibrations of cantilevers in contact with a sample surface have shown sensitivities as high as few picometers for detecting surface displacements. Such a high sensitivity is harnessed in several AFM imaging modes. Here, we demonstrate a cantilever-resonance-based method to quantify electrostatic forces on a probe in the probe-sample junction in the presence of a surface potential or when a bias voltage is applied to the AFM probe. We find that the electrostatic forces acting on the probe tip apex can produce signals equivalent to a few pm of surface displacement. In combination with modeling, the measurements of the force were used to access the strength of the electrical field at the probe tip apex in contact with a sample. We find an evidence that the electric field strength in the junction can reach ca. 1 V nm –1 at a bias voltage of a few volts and is limited by non-ideality of the tip-sample contact. This field is sufficiently strong to significantly influence material states and kinetic processes through charge injection, Maxwell stress, shifts of phase equilibria, and reduction of energy barriers for activated processes. Besides, the results provide a baseline for accounting for the effects of local electrostatic forces in electromechanical AFM measurements as well as offer additional means to probe ionic mobility and field-induced phenomena in solids.

36 MATERIALS SCIENCE↗

Effects of a dielectric material in an ion source on the ion beam current density and ion beam energy

To understand a strong focusing phenomenon that occurs in a low-energy hydrogen ion beam, the electron temperature, the electron density, and the space potential in an ion source with cusped magnetic fields are measured before and after the transition to the focusing state using an electrostatic probe. The experimental results show that no significant changes are observed before or after the transition. However, we found unique phenomena that are characterized by the position of the electrostatic probe in the ion source chamber. Specifically, the extracted ion beam current density and energy are obviously enhanced in the case where the electrostatic probe, which is covered by a dielectric material, is placed close to an acceleration electrode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital smoothing of the Langmuir probe I-V characteristic

Electrostatic probes or Langmuir probes are the most common diagnostic tools in plasma discharges. The second derivative of the Langmuir probe I-V characteristic is proportional to the electron energy distribution function. Determining the second derivative accurately requires some method of noise suppression. We compare the Savitzky-Golay filter, the Gaussian filter, and polynomial fitting to the Blackman filter for digitally smoothing simulated and measured I-V characteristics. We find that the Blackman filter achieves the most smoothing with minimal distortion for noisy data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multi-channel capacitive probe for electrostatic fluctuation measurement in the Madison Symmetric Torus reversed field pinch

A 40-channel capacitive probe has been developed to measure the electrostatic fluctuations associated with the tearing modes deep into Madison Symmetric Torus (MST) reversed field pinch plasma. The capacitive probe measures the ac component of the plasma potential via the voltage induced on stainless steel electrodes capacitively coupled with the plasma through a thin annular layer of boron nitride (BN) dielectric (also serves as the particle shield). When bombarded by the plasma electrons, BN provides a sufficiently large secondary electron emission for the induced voltage to be very close to the plasma potential. The probe consists of four stalks each with ten cylindrical capacitors that are radially separated by 1.5 cm. The four stalks are arranged on a 1.3 cm square grid so that at each radial position, there are four electrodes forming a square grid. Every two adjacent radial sets of four electrodes form a cube. The fluctuating electric field can be calculated by the gradient of the plasma potential fluctuations at the eight corners of the cube. The probe can be inserted up to 15 cm (r/a = 0.7) into the plasma. Furthermore, the capacitive probe has a frequency bandwidth from 13 Hz to 100 kHz, amplifier-circuit limit, sufficient for studying the tearing modes (5-30 kHz) in the MST reversed-field pinch.

47 OTHER INSTRUMENTATION↗