Search NASASearch

SEARCH · Search NASA

Results for “ELVIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Performance Testing of Enhanced Linear Variable Integrated Sensor (ELVIS III) for LVDTs

The Enhanced Linear Variable Intrinsic Sensor (ELVIS) was a 2024 breakthrough discovery by Idaho National Laboratory (INL) in terms of further innovating the usage of all linear variable differential transformers (LVDTs) and enhancing their performance in harsh environments. In irradiation tests conducted within material test reactors (MTRs), LVDTs with an internal temperature sensing capability can address several critical challenges. This report focuses on performance testing of the ELVIS III device with new hybrid LVDTs provided by the Institute for Energy Technology (IFE), which is the world’s sole supplier of nuclear-grade LVDTs. The ELVIS III device was evaluated in terms of temperature showcasing promising results comparable to a typical type-K thermocouple (TC).

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN

Microstructure, stored energy, and stability of H/He-filled nanocavities in low temperature irradiated Inconel 718

The microstructure, trapped transmutation gases, stored energy, and mechanical behavior of samples from an irradiated Inconel 718 proton beam window were characterized using transmission electron microcopy, thermal desorption spectrometry (TDS), differential scanning calorimetry (DSC), and tensile testing. In the as-irradiated condition the microstructure contained a high number density of 1–3 nm gas-filled nanocavities. Emissions of trapped gases, H and He, during TDS correlated with peaks of the energy release curves from DSC examinations, which suggest these gases were likely stored in highly stable defect traps. The stored energy from radiation damage saturated at doses of a few dpa and did not increase with increasing radiation dose, but the amount of stored H and He increased with increasing dose. Effects of post-irradiation annealing were studied as well. After exposure to 700 °C, the nanocavities grew only slightly to 2–4 nm in diameter, but after exposure to 900 °C, the cavities grew to 10–20 nm in diameter and electron energy-loss spectroscopy showed these cavities contained a core of He surrounded by a shell of H. Further, this study demonstrated that the irradiation defect structures containing H and He were remarkably stable during irradiation and after exposure up to 700 °C. The effect of the irradiation temperature, defect mobility, and interaction of H, He, and irradiation defects on mechanical behavior provides insight into the processes responsible for the unusual recovery in ductility with increasing radiation dose observed in Inconel 718 after high energy proton and spallation neutron irradiation.

36 MATERIALS SCIENCE

Long-term thermal stability and calibration of Type-II fiber Bragg grating array inscribed in radiation-hardened fibers

This paper investigates the long-term thermal stability of Type-II fiber Bragg grating (FBG) arrays, inscribed by femtosecond laser in radiation-hardened fiber, for potential applications as multiplexed sensors in high-temperature energy systems. The thermal stability of FBG sensors was assessed through 16 thermal cycles from room temperature (RT) to 750 ℃ about two months, involving 100 FBG sensors. The results show that the absolute temperature drift of FBG sensors can be reduced to less than 0.4 pm/day after 54 h thermal annealing process at a constant temperature of 800 ℃. As temperature sensors, the FBGs demonstrated stable performance, achieving a standard deviation (STD) of 1.8 pm (corresponding to a temperature resolution of 0.118 ℃) post-annealing. Repeated thermal cycles revealed a random drift of 2.3 pm in the FBG wavelength at RT. Polynomial fitting was explored as a calibration method to convert FBG wavelength shifts into absolute temperature measurements. By optimizing calibration temperature points (RT, 200 ℃, 400 ℃, and 750 ℃), the study shows that cubic polynomial calibration using four points yields an average R2 of 0.9997 and an RMSE of 3.58 ℃ across the entire temperature range (RT to 750 ℃). This approach represents an 11.53-fold improvement over empirical slope calibration and a 1.34-fold improvement over four-point piecewise fitting. The findings indicate that Type-II FBGs inscribed in radiation-hardened fibers can function as accurate temperature sensors, with performance on par with or exceeding that of thermocouples. With their multiplexing capability, robust signal transmission over long lead cables, and immunity to electromagnetic interference, FBG sensors offer a promising alternative to traditional electronic sensors for energy system monitoring.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018

Exercise alters molecular profiles of inflammation and substrate metabolism in human white adipose tissue

White adipose tissue (WAT) plays a significant role in whole body energy homeostasis, and its excess typifies obesity. In addition to WAT quantity, perturbations in the basic cellular processes of WAT (i.e., quality) are also associated with obesity and metabolic disease. Exercise training alleviates metabolic perturbations associated with obesity; however, the underlying molecular mechanisms that drive these metabolic adaptations in WAT are not well described. For this work, abdominal subcutaneous WAT biopsies were collected after an acute bout of exercise (1 day after) at baseline and following 3 wk of supervised aerobic training in sedentary overweight women (n = 6) without alterations in body weight and fat mass. RNA-seq, global proteomics, and phosphoproteomics in WAT revealed training-induced changes in 1,527 transcripts, 154 proteins, and 144 phosphosites, respectively. Training decreased abundance of transcripts and proteins involved in inflammation and components of the extracellular matrix and increased abundance of transcripts and proteins related to fatty acid esterification and lipolysis. In summary, short-term aerobic training significantly reduces local inflammation and increases lipid metabolism in WAT of sedentary overweight women—independent of alterations in body and fat mass. As such, some of the health benefits of aerobic training may occur through molecular alterations in WAT (i.e., enhanced quality) rather than a sheer reduction in WAT quantity.

60 APPLIED LIFE SCIENCES

Resilient Communities, Maryland (RCM): A Framework for Community-Driven Energy Resilience (Final Technical Report)

The Resilient Communities, Maryland (RCM) project integrates community-based participatory research (CBPR) approaches into energy resilience planning. The combination of qualitative, community-driven data and quantitative utility data improves both the effectiveness and efficiency of assessing the impacts of disruptions to energy infrastructure. Centered around a metric of critical services access, RCM created a repeatable framework for evaluating and modeling energy resilience in communities and promoted community engagement, resulting in more equitable stakeholder participation and improved decision-making processes for siting infrastructure to improve community energy resilience.

14 SOLAR ENERGY

Chandra Discovery of a Candidate Hyperluminous X-Ray Source in MCG+11-11-032

We present a multiwavelength analysis of MCG+11-11-032, a nearby active galactic nucleus (AGN), with a unique classification as being both a binary and a dual AGN candidate. With new Chandra observations, we aim to resolve any dual AGN system via imaging data and search for signs of a binary AGN via analysis of the X-ray spectrum. Analyzing the Chandra spectrum, we find no evidence of the previously suggested double-peaked Fe Kα lines; the spectrum is instead best fit by an absorbed power law with a single Fe Kα line, as well as an additional line centered at ≈7.5 keV. The Chandra observation reveals faint, soft, and extended X-ray emission, possibly linked to low-level nuclear outflows. Further analysis shows evidence for a compact hard source—MCG+11-11-032 X2—located 3.″3 from the primary AGN. Modeling MCG+11-11-032 X2 as a compact source, we find that it is relatively luminous (L2–10 keV=1.5−0.5+0.9×1041erg s$^{−1}$), and the location is coincident with a compact and off-nuclear source resolved in Hubble Space Telescope infrared (F105W) and optical (F621M, F547M) bands. Pairing our X-ray results with a 144 MHz radio detection at the host galaxy location, we observe X-ray and radio properties similar to those of ESO 243-49 HLX-1, suggesting that MCG+11-11-032 X2 may be a hyperluminous X-ray source. This detection with Chandra highlights the importance of a high-resolution X-ray imager as well as how previous binary AGN candidates detected with large-aperture instruments can benefit from high-resolution follow-up. Future spatially resolved optical spectra, and deeper X-ray observations, can better constrain the origin of MCG+11-11-032 X2.

79 ASTRONOMY AND ASTROPHYSICS

EVALUATION OF OPERATION TEMPERATURES UNDER NATURAL CONVECTION HELIUM FLOW IN A CONFINED CAVITY

The Spallation Neutron Source (SNS) is a high-power accelerator-based pulsed neutron source led by Oak Ridge National Laboratory (ORNL) to achieve high fluxes of neutrons for scientific experiments. Active and passive cooling of the systems and parts forming the SNS have been considered to warrant the safe operation of the facility. The diverse cooling systems make use of conjugated heat transfer mechanisms to provide a stable operation temperature for all components in the machine. Thermal power deposited into stainless-steel piping lines due to particle radiation may reach values of up to 1.2 W/cc in the regions located closer to the center of the lower IRP. These energy deposition levels, in not actively cooled components, such as the transfer-line-outer-vacuum-layer may increase the temperature of the component beyond design requirement limitations. The evaluation of the operation temperatures for the former components relies in the assumption that a low-pressure helium atmosphere provides enough heat removal capacity based on natural convection phenomena. In this work, the evaluation of steady state temperatures in components such as the CMS transfer lines has been evaluated using computational fluid dynamics (CFD), analytical correlations and experimental measurements. The companion experiments were conducted in a closed helium system at pressures varying from 1.1 to 1.5 bar. A copper rod was affixed horizontally between viewing windows and heated at constant power, and measurements were made of both the rod temperature and ambient temperature via a system fiberoptic distributed temperature sensors and RTDs. It was found that the measured heat transfer coefficients agree well with the predictions of Churchill and Chu correlations across the range of cases considered. Additionally, the ambient helium volume above the rod was imaged via background oriented schlieren (BOS), and these data was used to determine the line-averaged density gradients in this region. These gradients were compared to simulation data to validate the predictions of natural convection simulations.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018

Experimental and Computational Study of Weld Drop-Through Hydraulic Effects in Multi-Layer Concentric Pipes Servicing Cryogenic Liquid Hydrogen

The Cryogenic Moderator System (CMS) at the Oak Ridge National Laboratory (ORNL)-Spallation Neutron Source (SNS) supplies liquid hydrogen, through vacuum insulated transfer lines to the moderators. The welding process used to make the transfer lines produces weld drop-through, which can constrict the flow of hydrogen and/or cause thermal bridges between adjacent layers. To ensure proper operation of the CMS it is therefore necessary to conduct a flow test to verify the pressure drop caused by the welds. Measurements in as-built piping sections intended to provide liquid hydrogen service to the SNS-CMS system were performed to test the effect of weld penetrations into the fluid flow area focusing on pressure drop effects. The reference test sections were designed using prototypical piping dimensions, materials and expected penetration welds. A numerical study using Computational Fluid Dynamics (CFD) tools in the transfer lines provided a conversion factor from the pressure drop measured in the lines with water to the expected pressure drop using liquid cryogenic hydrogen. The results show evidence of a maximum pressure drop modification in water of 78 KPa in the tested parts, which scales to liquid hydrogen as PHydrogen = 5.2 KPa. The maximum measured equivalent blockage area percentage was found in the as-built TDM transfer line spool 2 with a value of 31%. The measured values obtained in the as-built transfer lines provided accurate values to estimate the expected total pressure drop in the CMS system providing operational limits for the current recirculatory capacity. The effect of the weld drop-through in hydrogen evacuation capacity scenarios was better evaluated as a result of this study.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018