Search NASA⌕ Search

SEARCH · Search NASA

Results for “EM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Cryo-EM Visualization of Intermolecular π-Electron Interactions within π-Conjugated Peptidic Supramolecular Polymers

The self-assembly of “π-peptides” – molecules with π-electron cores substituted with two or more oligopeptide chains – brings organic electronic function into biologically relevant nanomaterials. π-Peptides assemble into fibrillar nanomaterials as driven by enthalpic peptide-based hydrogen bonding networks and pi-core-based quadrupolar interactions. A large body of spectroscopic, morphological and computational studies informs on the nature of the self-assembly process and the resulting nanostructures, but detailed structural information has remained elusive. Here, inspired by the recent use of cryogenic electron microscopy (cryo-EM) to provide high-resolution structures for synthetic peptide nanomaterials, we present here the use of cryo-EM to offer ca. 3 Å resolution of π-peptide nanomaterial assemblies, visualizing for the first time the nature of the intermolecular π-core electronic interactions responsible for energy transport through these supramolecular materials.

Group theory↗

EMS and DMS Integration of the Coordinative Real-time Sub-Transmission Volt-Var Control Tool under High DER Penetration

This paper proposes an applicable approach to deploy the Coordinative Real-time Sub-Transmission Volt-Var Control Tool (CReST-VCT), and a holistic system integration framework considering both the energy management system (EMS) and distribution system management system (DMS). This provides an architectural basis and can serve as the implementation guideline of CReST-VCT and other advanced grid support tools, to co-optimize the operation benefits of DERs and assets in both transmission and distribution networks. Potential communication protocols for different physical domains of a real application is included. Performance and security issues are also discussed, along with specific considerations for field deployment. Finally, the paper presents a viable pathway for CReST-VCT and other advanced grid support tools, which could be integrated in an open-source standardized-based platform that supports distribution utilities.

Nguyen, Quan H.↗

Cryo-EM structure of an extracellular Geobacter OmcE cytochrome filament reveals tetrahaem packing

Electrically conductive appendages from the anaerobic bacterium Geobacter sulfurreducens were first observed two decades ago, with genetic and biochemical data suggesting that conductive fibres were type IV pili. Recently, an extracellular conductive filament of G. sulfurreducens was found to contain polymerized c-type cytochrome OmcS subunits, not pilin subunits. Here we report that G. sulfurreducens also produces a second, thinner appendage comprised of cytochrome OmcE subunits and solve its structure using cryo-electron microscopy at ~4.3 A resolution. Although OmcE and OmcS subunits have no overall sequence or structural similarities, upon polymerization both form filaments that share a conserved haem packing arrangement in which haems are coordinated by histidines in adjacent subunits. Unlike OmcS filaments, OmcE filaments are highly glycosylated. In extracellular fractions from G. sulfurreducens, we detected type IV pili comprising PilA-N and -C chains, along with abundant B-DNA. OmcE is the second cytochrome filament to be characterized using structural and biophysical methods. Here, we propose that there is a broad class of conductive bacterial appendages with conserved haem packing (rather than sequence homology) that enable long-distance electron transport to chemicals or other microbial cells.

59 BASIC BIOLOGICAL SCIENCES↗

Novel features and GPU performance analysis for EM particle transport in the Celeritas code

Celeritas is a new computational transport code designed for high-performance simulation of high-energy physics detectors. This work describes some of its current capabilities and the design choices that enable the rapid development of efficient on-device physics. The abstractions that underpin the code design facilitate low-level performance tweaks that require no changes to the higher-level physics code. We evaluate a set of independent changes that together yield an almost 40% speedup over the original GPU code for a net performance increase of 220× for a single GPU over a single CPU running 8.4M tracks on a small demonstration physics app.

Johnson, Seth R.↗

Intelligent resolution: Integrating Cryo-EM with AI-driven multi-resolution simulations to observe the severe acute respiratory syndrome coronavirus-2 replication-transcription machinery in action

The severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) replication transcription complex (RTC) is a multi-domain protein responsible for replicating and transcribing the viral mRNA inside a human cell. Attacking RTC function with pharmaceutical compounds is a pathway to treating COVID-19. Conventional tools, e.g., cryo-electron microscopy and all-atom molecular dynamics (AAMD), do not provide sufficiently high resolution or timescale to capture important dynamics of this molecular machine. Consequently, we develop an innovative workflow that bridges the gap between these resolutions, using mesoscale fluctuating finite element analysis (FFEA) continuum simulations and a hierarchy of AI-methods that continually learn and infer features for maintaining consistency between AAMD and FFEA simulations. We leverage a multi-site distributed workflow manager to orchestrate AI, FFEA, and AAMD jobs, providing optimal resource utilization across HPC centers. Our study provides unprecedented access to study the SARS-CoV-2 RTC machinery, while providing general capability for AI-enabled multi-resolution simulations at scale.

Trifan, Anda↗

Use of Historical EM Practices and Policies for Management of Cleanup Program and Address GAO Concerns - 20222

As Department of Energy (DOE) Environmental Management (EM) program policies and management practices are revised over time, it might be useful to periodically reflect on the DOE EM program's past to identify practices that have worked and those that might be appropriate for possible reuse in the future. An added impetus to examine alternative approaches is the recent Government Accountability Office (GAO) report entitled 'Nuclear Waste Cleanup - DOE Could Improve Program and Project Management by Better Classifying Work and Following Leading Practices.' The February 2019 GAO report states that EM categorizes most of its work in a way that does not adequately involve independent experts and DOE senior leadership. It also noted that EM has not followed leading practices for program and project management that could help keep the cleanup efforts on schedule and control costs. The GAO report recommended that EM, working with DOE Office of Project Management (PM): - Establish requirements and then assess EM's ongoing operations activities to determine if some activities should be reclassified as capital asset projects based on these newly established requirements. - Review and revise EM's 2017 cleanup policy to include program management leading practices related to scope, cost, schedule performance, and independent reviews. - Update the cleanup policy to require that earned value management (EVM) systems be maintained and used in a way that follows EVM best practices. - Develop a policy to ensure that work is categorized as level of effort (LOE) only in appropriate, specified circumstances, such as when work is not measurable or when measurement is impractical. - Integrate EVM data into EM's performance metrics for operations activities. To assist with improving program performance and implementing audit recommendations, this paper reviewed past successful cleanups such as Weldon Springs, Rocky Flats, Fernald, Ashtabula, Battelle Columbus (abs, and other historical resources and people with experience during the early years of EM program. As such, there are several past practices which may well be suited for reuse today. Some of these practices include: - In 1990's, as the DOE EM cleanup program, known as Environmental Restoration came into effect, the known cleanup scope at each geographic location or site was organized into four levels ranging from overall site-wide cleanup effort to the individual 'release sites', providing high granularity to the program. - The cleanup program was organized by geography (Northwest, Southwest, Eastern Area Programs, etc.). These 'sub-program' managers provided a degree of Headquarters oversight and management allowing upper management (EM-1, 2, and 3) to focus on major decisions and issues. - Budget levels at selected cleanup sites were funded above 'minimum-safety' levels to accelerate actual cleanup work. - Past practice utilized EVM techniques and uniform EM oversight over all discrete project-like activities, providing for a coordinated cleanup effort. - EM managed LOE activities using benchmarking and best in class management practice techniques to help manage costs. - EM managed and reviewed entire site cleanup baselines, not only individual projects, focusing on a successful overall outcome. - Sites had a 'Road map' or 'Management Action Plan' that provided the overall strategy or plan for that site's cleanup - this helped with understanding and coordination of efforts. - EM had a robust lessons-learned program and database to capture and transmit worthy ideas. - EM had well-structured cleanup baseline change control policies to control cost and schedule changes, at the contractor and higher Headquarters levels. Finally, some of the GAO observations may be valid, however it is not clear as to their extent. For example, for some operation types of work, the use of the Level of Effort (LOE) earned value method to track progress may be appropriate. Also, to ensure independence of thought, and to obtain useful insight on past practices, it may be suitable to have former EM employees to assist with understanding past practices or to verify that activities have been properly identified. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CryoSegNet: accurate cryo-EM protein particle picking by integrating the foundational AI image segmentation model and attention-gated U-Net

Picking protein particles in cryo-electron microscopy (cryo-EM) micrographs is a crucial step in the cryo-EM-based structure determination. However, existing methods trained on a limited amount of cryo-EM data still cannot accurately pick protein particles from noisy cryo-EM images. The general foundational artificial intelligence–based image segmentation model such as Meta’s Segment Anything Model (SAM) cannot segment protein particles well because their training data do not include cryo-EM images. Here, we present a novel approach (CryoSegNet) of integrating an attention-gated U-shape network (U-Net) specially designed and trained for cryo-EM particle picking and the SAM. The U-Net is first trained on a large cryo-EM image dataset and then used to generate input from original cryo-EM images for SAM to make particle pickings. CryoSegNet shows both high precision and recall in segmenting protein particles from cryo-EM micrographs, irrespective of protein type, shape and size. On several independent datasets of various protein types, CryoSegNet outperforms two top machine learning particle pickers crYOLO and Topaz as well as SAM itself. The average resolution of density maps reconstructed from the particles picked by CryoSegNet is 3.33 Å, 7% better than 3.58 Å of Topaz and 14% better than 3.87 Å of crYOLO. It is publicly available at https://github.com/jianlin-cheng/CryoSegNet

59 BASIC BIOLOGICAL SCIENCES↗

EMS-Induced Mutagenesis of Clostridium carboxidivorans for Increased Atmospheric CO 2 Reduction Efficiency and Solvent Production

Clostridium carboxidivorans (P7) is one of the most important solvent-producing bacteria capable of fermenting syngas (CO, CO 2 , and H 2 ) to produce chemical commodities when grown as an autotroph. This study aimed to develop ethyl methanesulfonate (EMS)-induced P7 mutants that were capable of growing in the presence of CO 2 as a unique source of carbon with increased solvent formation and atmospheric CO 2 reduction to limit global warming. Phenotypic analysis including growth and end product characterization of the P7 wild type (WT) demonstrated that this strain grew better at 25 °C than 37 °C when CO 2 served as the only source of carbon. In the current study, 55 mutagenized P7-EMS mutants were developed by using 100 mM and 120 mM EMS. Interestingly, using a forward genetic approach, three out of the 55 P7-EMS mutants showed a significant increase in ethanol, butyrate, and butanol production. The three P7-EMS mutants presented on average a 4.68-fold increase in concentrations of ethanol when compared to the P7-WT. Butyric acid production from 3 P7-EMS mutants contained an average of a 3.85 fold increase over the levels observed in the P7-WT cultures under the same conditions (CO 2 only). In addition, one P7-EMS mutant presented butanol production (0.23 ± 0.02 g/L), which was absent from the P7-WT under CO 2 conditions. Most of the P7-EMS mutants showed stability of the obtained end product traits after three transfers. Most importantly, the amount of reduced atmospheric CO 2 increased up to 8.72 times (0.21 g/Abs) for ethanol production and up to 8.73 times higher (0.16 g/Abs) for butyrate than the levels contained in the P7-WT. Additionally, to produce butanol, the P7-EMSIII-J mutant presented 0.082 g/Abs of CO 2 reduction. This study demonstrated the feasibility and effectiveness of employing EMS mutagenesis in generating solvent-producing anaerobic bacteria mutants with improved and novel product formation and increased atmospheric CO 2 reduction efficiency.

59 BASIC BIOLOGICAL SCIENCES↗

CryoTEN: efficiently enhancing cryo-EM density maps using transformers

Abstract Motivation Cryogenic electron microscopy (cryo-EM) is a core experimental technique used to determine the structure of macromolecules such as proteins. However, the effectiveness of cryo-EM is often hindered by the noise and missing density values in cryo-EM density maps caused by experimental conditions such as low contrast and conformational heterogeneity. Although various global and local map-sharpening techniques are widely employed to improve cryo-EM density maps, it is still challenging to efficiently improve their quality for building better protein structures from them. Results In this study, we introduce CryoTEN—a 3D UNETR++ style transformer to improve cryo-EM maps effectively. CryoTEN is trained using a diverse set of 1295 cryo-EM maps as inputs and their corresponding simulated maps generated from known protein structures as targets. An independent test set containing 150 maps is used to evaluate CryoTEN, and the results demonstrate that it can robustly enhance the quality of cryo-EM density maps. In addition, automatic de novo protein structure modeling shows that protein structures built from the density maps processed by CryoTEN have substantially better quality than those built from the original maps. Compared to the existing state-of-the-art deep learning methods for enhancing cryo-EM density maps, CryoTEN ranks second in improving the quality of density maps, while running >10 times faster and requiring much less GPU memory than them. Availability and implementation The source code and data are freely available at https://github.com/jianlin-cheng/cryoten.

Biochemistry & Molecular Biology↗

CERES : a cryo-EM re-refinement system for continuous improvement of deposited models

The field of electron cryomicroscopy (cryo-EM) has advanced quickly in recent years as the result of numerous technological and methodological developments. This has led to an increase in the number of atomic structures determined using this method. Recently, several tools for the analysis of cryo-EM data and models have been developed within the Phenix software package, such as phenix.real_space_refine for the refinement of atomic models against real-space maps. Also, new validation metrics have been developed for low-resolution cryo-EM models. To understand the quality of deposited cryo-EM structures and how they might be improved, models deposited in the Protein Data Bank that have map resolutions of better than 5 Å were automatically re-refined using current versions of Phenix tools. The results are available on a publicly accessible web page (https://cci.lbl.gov/ceres). The implementation of a Cryo-EM Re-refinement System ( CERES ) for the improvement of models deposited in the wwPDB, and the results of the re-refinements, are described. Based on these results, contents are proposed for a `cryo-EM Table 1', which summarizes experimental details and validation metrics in a similar way to `Table 1' in crystallography. The consistent use of robust metrics for the evaluation of cryo-EM models and data should accompany every structure deposition and be reported in scientific publications.

59 BASIC BIOLOGICAL SCIENCES↗

Nevada Higher Education Benefits from US Department of Energy (DOE) Environmental Management (EM) Nevada Program's Transfer of Geologic Samples - 20442

The Nevada National Security Site (NNSS), formerly the Nevada Test Site, was the location of 100 historic atmospheric and 828 historic underground nuclear tests from 1951 to 1992. Related to this historic nuclear testing, geologic and hydrologic studies of the site were conducted utilizing the skills and the expertise of the U.S. Geological Survey (USGS) and national laboratories (Los Alamos National Laboratory, Lawrence Livermore National Laboratory), who were principal in leading the development of weapons and were responsible for specific underground testing programs. The subsurface samples and technical/scientific data associated with NNSS geologic studies (past and present) are preserved and stored at the USGS Mercury Core Library and Data Center located at the NNSS. Currently, the facility stores over 2,000,000 linear feet of cores and cuttings from more than 2,600 drill holes that can be accessed for study. Most of the samples and historic geologic work was focused directly on subsurface geologic settings that relate directly to historic underground nuclear testing. Since 1992, the United States has observed a unilateral moratorium on full-scale nuclear testing, and the U.S. Department of Energy (DOE) Environmental Management (EM) Nevada Program is now responsible for hydrogeologic characterization of the potential impacts to the natural groundwater systems that may have resulted from historic underground nuclear tests. As part of this effort, the EM Nevada Program Underground Test Area (UGTA) Activity has drilled and completed over 58 deep (2,000 - 7,000 ft.) characterization wells, totaling in excess of 170,000 linear feet of cuttings and core samples. Cutting samples were collected as triplicate samples for each respective depth interval, to account for potential later nondestructive/destructive analysis and to preserve samples for regulatory purposes. Recently, it was recognized by the EM Nevada Program that opportunities may exist to reduce the cost and floor space required for the storage of geologic samples at the Mercury Core Library without impacting the integrity and representative nature of the samples necessary for project execution. An initiative was sponsored by EM Nevada Program to evaluate several options: 1) disposal of a portion of cuttings and cores in a land fill setting; 2) reduction in sample volume through skeletonizing core and cuttings from wells to a representative but much smaller number of samples; and 3) solicit potential interest in the academic community where other geoscientists could freely access the samples for studies. The Nevada state university system through the Nevada Bureau of Mines and Geology responded positively to the opportunity to receive these NNSS samples from the EM Nevada Program. In June 2019, approximately 17,000 geologic samples, representing greater than 170,000 linear feet of drilling and weighing over 20,000 pounds, were shipped from the NNSS to the Great Basin Science Sample and Records Library located in Reno, Nevada. The benefits resulting from this transfer were realized by the EM Nevada Program in terms of cost and space savings for geologic sample storage at the NNSS. The transfer did not impact the EM Nevada Program mission as access to representative geologic samples for regulatory and scientific purposes was preserved. Moreover, the Nevada Bureau of Mines and Geology acquired a significant resource of subsurface geologic samples and supporting technical data to support academic and scientific studies in a complex volcanic setting in southwest Nevada. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An assessment of controlled source EM for monitoring subsurface CO 2 injection at the wyoming carbonSAFE geologic carbon storage site

Here we evaluate if electromagnetic (EM) geophysical methods for monitoring geologic carbon storage (GCS) efforts at the Wyoming CarbonSAFE project adjacent to the Dry Fork Station power plant near Gillette, Wyoming. This first involved acquiring both electric and magnetic fields at eleven different locations ranging in distance from immediately adjacent to 4 km from the plant. Passive EM measurements were made to provide spectral EM noise measurements generated by electricity production at the plant and to determine if useful magnetotelluric (MT) data can be successfully collected in the region. The processed data indicate that useful MT data can be collected as long as the site is located more than 2km away from the power plant as well as active roads and rail lines. Controlled source EM data were collected using three different source configurations, two of which connected to steel casings used to complete the injection wells. Comparing the EM noise measurements to the CSEM data show measurable electric and magnetic field signals at all sites. Next a series of three-dimensional (3D) numerical models were built that simulate resistivity changes caused by the proposed CO2 injection at depths ranging from 2.4 to 3.0km. These models were used to simulate various EM measurement configurations. The modeling shows that casing-source CSEM monitoring can provide sensitivity to the injected CO 2 if source electrodes are connected to the bottom of one or both of the injection wells.

58 GEOSCIENCES↗

Evolution of standardization and dissemination of cryo-EM structures and data jointly by the community, PDB, and EMDB

Cryogenic electron microscopy (cryo-EM) methods began to be used in the mid-1970s to study thin and periodic arrays of proteins. Following a half-century of development in cryo-specimen preparation, instrumentation, data collection, data processing and modeling software, cryo-EM has become a routine method for solving structures from large biological assemblies to small biomolecules at near to true atomic resolution. This review explores the critical roles played by the Protein Data Bank (PDB) and Electron Microscopy Data Bank (EMDB) in partnership with the community to develop the necessary infrastructure to archive cryo-EM maps and associated models. Public access to cryo-EM structure data has in turn facilitated better understanding of structure-function relationships and advancement of image processing and modeling tool development. The partnership between the global cryo-EM community and PDB and EMDB leadership has synergistically shaped the standards for metadata, one-stop deposition of maps and models, and validation metrics to assess the quality of cryo-EM structures. The advent of cryo-electron tomography (cryo-ET) for in situ molecular cell structures at a broad resolution range and their correlations with other imaging data introduces new data archival challenges in terms of data size and complexity in the years to come.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of atom resolvability in cryo-EM maps with Q-scores

Cryogenic electron microscopy (cryo-EM) maps are now at the point where resolvability of individual atoms can be achieved. However, resolvability is not necessarily uniform throughout the map. We introduce a quantitative parameter to characterize the resolvability of individual atoms in cryo-EM maps, the map Q-score. Q-scores can be calculated for atoms in proteins, nucleic acids, water, ligands and other solvent atoms, using models fitted to or derived from cryo-EM maps. Q-scores can also be averaged to represent larger features such as entire residues and nucleotides. Averaged over entire models, Q-scores correlate very well with the estimated resolution of cryo-EM maps for both protein and RNA. Here, assuming the models they are calculated from are well fitted to the map, Q-scores can be used as a measure of resolvability in cryo-EM maps at various scales, from entire macromolecules down to individual atoms. Q-score analysis of multiple cryo-EM maps of the same proteins derived from different laboratories confirms the reproducibility of structural features from side chains down to water and ion atoms.

59 BASIC BIOLOGICAL SCIENCES↗

Cryo2StructData: A Large Labeled Cryo-EM Density Map Dataset for AI-based Modeling of Protein Structures

The advent of single-particle cryo-electron microscopy (cryo-EM) has brought forth a new era of structural biology, enabling the routine determination of large biological molecules and their complexes at atomic resolution. The high-resolution structures of biological macromolecules and their complexes significantly expedite biomedical research and drug discovery. However, automatically and accurately building atomic models from high-resolution cryo-EM density maps is still time-consuming and challenging when template-based models are unavailable. Artificial intelligence (AI) methods such as deep learning trained on limited amount of labeled cryo-EM density maps generate inaccurate atomic models. To address this issue, we created a dataset called Cryo2StructData consisting of 7,600 preprocessed cryo-EM density maps whose voxels are labelled according to their corresponding known atomic structures for training and testing AI methods to build atomic models from cryo-EM density maps. Cryo2StructData is larger than existing, publicly available datasets for training AI methods to build atomic protein structures from cryo-EM density maps. We trained and tested deep learning models on Cryo2StructData to validate its quality showing that it is ready for being used to train and test AI methods for building atomic models.

59 BASIC BIOLOGICAL SCIENCES↗

Evolving data standards for cryo-EM structures

Electron cryo-microscopy (cryo-EM) is increasingly being used to determine 3D structures of a broad spectrum of biological specimens from molecules to cells. Anticipating this progress in the early 2000s, an international collaboration of scientists with expertise in both cryo-EM and structure data archiving was established (EMDataResource, previously known as EMDataBank). The major goals of the collaboration have been twofold: to develop the necessary infrastructure for archiving cryo-EM-derived density maps and models, and to promote development of cryo-EM structure validation standards. We describe how cryo-EM data archiving and validation have been developed and jointly coordinated for the Electron Microscopy Data Bank and Protein Data Bank archives over the past two decades, as well as the impact of evolving technology on data standards. Just as for X-ray crystallography and nuclear magnetic resonance, engaging the scientific community via workshops and challenging activities has played a central role in developing recommendations and requirements for the cryo-EM structure data archives.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗