Ensuring electromagnetic compatibility in grid-connected power converters: Challenges, standards, and compliance strategies

In today's rapidly advancing world, electronic devices and systems are fundamental to a wide range of industries, including renewable energy and global telecommunications infrastructure. However, as these devices become more complex and widespread, the risk of electromagnetic interference (EMI) also increases, underscoring the importance of stringent Electromagnetic Compatibility (EMC) requirements for maintaining system integrity. This paper addresses the specific challenges associated with grid-connected power converters (GCPCs), which are critical in integrating renewable energy into existing power grids. It explores the complexities of EMI in the context of GCPCs, particularly given the recent emergence of tailored EMC standards for these systems. The paper also highlights the shortcomings of applying generic or unrelated standards to GCPCs, often leading to inadequate compliance and testing protocols. Through a detailed analysis of existing standards and recent advancements in product-specific EMC requirements, this paper provides a comprehensive overview of the current landscape, offering guidance to stakeholders on navigating the intricate EMC compliance landscape, with a focus on methodologies, testing procedures, and the evolving regulatory environment for GCPCs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Compact, Single Stage, >1 kV Medium-Voltage Line Impedance Stabilization Network

This paper presents the design of a single-phase, single-stage line impedance stabilization network (LISN) for medium-voltage (MV) applications. More than 1 kV rated widebandgap (WBG) power semiconductor switches are increasingly utilized in new, emerging power electronics energy systems to improve power density and efficiency. However, due to inherently fast-switching speeds, WBG switch modules emit considerable electromagnetic interference (EMI) (e.g., common mode (CM) or differential mode (DM)). State-of-the-art offers standardized LISN solutions to validate and certify the new energy system for electromagnetic compatibility (EMC). However, most are for low voltage applications (i.e., < 1 kV). MV LISNs (i.e., > 1 kV) are rare until recently and literature does not provide sufficient guidelines for designing and characterizing such devices. It has been a critical challenge for many scientists and engineers to reliably certify the emerging MV energy systems (e.g., electric ships and aircraft). This paper addresses such a technology gap. Specifically, a CISPR 16-1-2 compliant 50Ω/50μH LISN with 1.5kV, 75A and 30MHz measurement capability has been proposed. Detailed performance study versus non-linear parasitic parameters variations in MV inductors and capacitors have been done. Based on new understandings, novel techniques to intuitively mitigate unwanted parasitic have been proposed to develop the proposed LISN successfully. Thorough characterization of important LISN parameters are presented and factors influencing them are analyzed. A rigorous analysis, experimental tests, and in-depth comparisons over state-of-the-art have been made to validate the effectiveness. This is done through the state-of-the-art 300kVA MV EMI testbed.

42 ENGINEERING↗

Criteria for Determining the Safety of Wireless Technologies at Nuclear Power Plants

This report provides an initial discussion of the potential impact to safety-related/important-to-safety (SR/ITS) systems by the possible expanded use of wireless technologies. One aspect of this discussion is focused on a review of Regulatory Guide (RG) 1.180 Rev. 2 to determine whether any revisions are necessary to reflect the current state of practice in evaluating and protecting instrumentation and control (I&C) systems and components from electromagnetic interference (EMI) or radiofrequency interference (RFI) on safety and nonsafety I&C. Electromagnetic compatibility (EMC) is the ability of a device or system to function satisfactorily in its electromagnetic (EM) environment, which is achieved by limiting the unintentional generation, propagation, and reception of EM energy that may cause unwanted effects such as EMI. The goal of EMC is to ensure the correct operation of different types of equipment in a common EM environment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Detector Noise Susceptibility Issues for the Future Generation of High Energy Physics Experiments

The front-end electronics (FEE) noise characterization to electromagnetic interference and the compatibility of the different subsystems are important topics to consider for the LHC calorimeter upgrades. A new power distribution scheme based on switching power converters is under study and will define a noticeable noise source very close to the detector's FEE. Knowledge and experience with both FFE noise and electromagnetic compatibility (EMC) issues from previous detectors are important conditions to guarantee the design goals and the good functionality of the upgraded LHC detectors. This paper shows an overview of the noise susceptibility studies performed in different CMS subdetectors. The impact of different FEE topologies in the final sensitivity to electromagnetic interference of the subsystem is analyzed and design recommendations are presented to increase the EMC of the detectors to the future challenging power distribution topologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling and analyzing parasitic parameters in high frequency converters

This research focuses on electromagnetic interference (EMI) / electromagnetic compatibility (EMC) design and analysis in power electronics systems. To limit the EMI under the standards, different methods and strategies are investigated. Parasitic parameters of high frequency (HF) transformer are analyzed using a novel analytical method, finite element method (FEM), and experimental measurements for different structures and windings arrangements. Also, the magnetic field, electric field, electric displacement, and electric potential distribution are simulated and analyzed. Moreover, a high voltage system is considered and analyzed to improve the EMC. The EMI propagation paths are analyzed. The EMI noise level of the system is obtained and compared to the IEC61800-3 standard. To improve the EMC, the parasitic parameters of the transformer, as the main path of EMI circulation, are analyzed and optimized to block the propagation. Furthermore, the geometry structure of the HF transformer is optimized to lower the parasitics in the system. Three pareto-optimal techniques are investigated for the optimization. The models and results are verified by 3D-FEM and experimental results for several given scenarios. Furthermore, the EMC modeling and conducted EMI analysis are developed for a system including an AC-DC-DC power supply (rectifier and dual active bridge (DAB) converter). Moreover, the common mode (CM) EMI noise propagation through the system is discussed and the noise sources and effect of components on the noise are analyzed. Additionally, the CM impedance of different parts of the system and the noise levels are discussed. Finally, EMI attenuation techniques were applied to the system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Implementation of wireless technologies in nuclear power plants' electromagnetic environment using cognitive radio system - 153

Wireless technologies have increased efficiency in many industrial settings across the world by enabling a mobile workforce and improving communications. Unfortunately, the nuclear power industry has been slow to adopt wireless technology as a result of safety, security, and reliability concerns expressed by regulators and others. A Research and Development (R and D) effort is currently being conducted to address two significant technical concerns for the introduction of wireless technology in nuclear power plants, which are electromagnetic compatibility (EMC) and wireless coexistence. Most equipment in nuclear power plants has never been tested for vulnerability to wireless transmission. As such, the impact of modern wireless devices on nuclear safety and plant reliability is not understood. Existing guidance from the Nuclear Regulatory Commission (NRC) and Electric Power Research Institute (EPRI) rely on the use of exclusion zones to protect plant equipment, which can result in exclusion zones of up to eight feet for some tablet devices rendering them ineffective for the mobile workforce. Another unknown is how different wireless devices will operate in close proximity to one another in the harsh electromagnetic environment of a nuclear power plant. These issues are being addressed through development of a cognitive radio system that has the ability to generate and output multiple wireless signals such as Wi-Fi, Bluetooth, and cellular communications at varying power levels and frequencies. The cognitive radio system is a modular system that can test nuclear plant equipment located in training areas, simulators, and the actual plant environment. In addition to using the system for testing plant equipment to wireless signals and EMC standards, the system can also monitor the radio spectrum for usage in other plant focuses such as cyber security. The R and D work will provide the objective guidance for the nuclear industry in the two areas mentioned and will develop a cognitive radio system for in-plant EMC and coexistence testing. The system will assist in the seamless use of wireless technology in nuclear power plants while greatly reducing the risks wireless signals may introduce. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An Analog Active Gate Drive Circuit Architecture for Wide Band Gap Devices

With the increased usage of SiC and GaN devices in power converters, it is apparent to engineers that the benefits of these devices for low switching losses have to be balanced against two deterrents: (1) the faster rise and fall times of these devices lead to increased harmonic content, making it more difficult to meet Electromagnetic Compatibility (EMC) regulations; and (2) increased sensitivity to parasitic elements in the board layout, leading to higher dv DS /dt and di D /dt with higher current and voltage peak stresses. "Active" gate drives are thus needed to regulate different regions of switching to achieve the optimal tradeoff between switching loss and EMC. We present a simple analog circuit architecture for an active gate drive. Turn on and turn off tests with SiC modules and discrete parts are discussed with experimental results.

Ramabhadran, Ramanujam↗

Technical Basis for Electromagnetic Compatibility Regulatory Guidance Update

The objective of this report is to serve as the technical basis document for the next, planned revision of this RG that highlights and provides the rationale for the recommended changes. The structure of this document follows and summarizes the several assessment activities undertaken during the course of this project to evaluate new and updated electromagnetic compatibility (EMC) standards, testing methods and limits, and relevant technology developments being incorporated into plant activities that may have EMI/RFI implications, as well as other specific issues, including impacts of electrostatic discharge (ESD) on safety equipment and impacts on increased usage of wireless devices in nuclear power plants.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Digital I and C system upgrade integration technique

This work developed an integration technique for digital I and C system upgrade, the utility can replace the I and C systems step by step systematically by this method. Inst. of Nuclear Energy Research (INER) developed a digital Instrumentation and Control (I and C) replacement integration technique on the basis of requirement of the three existing nuclear power plants (NPPs), which are Chin-Shan (CS) NPP, Kuo-Sheng (KS) NPP, and Maanshan (MS) NPP, in Taiwan, and also developed the related Critical Digital Review (CDR) Procedure. The digital I and C replacement integration technique includes: (I) Establishment of Nuclear Power Plant Digital Replacement Integration Guideline, (2) Preliminary Investigation on I and C System Digitalization, (3) Evaluation on I and C System Digitalization, and (4) Establishment of I and C System Digitalization Architectures. These works can be a reference for performing I and C system digital replacement integration of the three existing NPPs of Taiwan Power Company (TPC). A CDR is the review for a critical system digital I and C replacement. The major reference of this procedure is EPRI TR- 1011710 (2005) 'Handbook for Evaluating Critical Digital Equipment and Systems' which was published by the Electric Power Research Inst. (EPRI). With this document, INER developed a TPC-specific CDR procedure. Currently, CDR becomes one of the policies for digital I and C replacement in TPC. The contents of this CDR procedure include: Scope, Responsibility, Operation Procedure, Operation Flow Chart, CDR review items. The CDR review items include the comparison of the design change, Software Verification and Validation (SVandV), Failure Mode and Effects Analysis (FMEA), Evaluation of Diversity and Defense-in-depth (D3), Evaluation of Watchdog Timer, Evaluation of Electromagnetic Compatibility (EMC), Evaluation of Grounding for System/Component, Seismic Evaluation, Witness and Inspection, Lessons Learnt from the Digital I and C Failure Events. A solid review can assure the quality of the digital I and C system replacement. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Electromagnetic compatibility qualification of power electronics for I and C power applications - 152

Electromagnetic Compatibility (EMC) is a growing field in nuclear equipment qualification. Previously confined to I and C equipment residing in control and cable spreading rooms, EMC qualification has expanded to include the inverters and battery chargers which often power safety-related I and C equipment, as well as adjustable speed drives and material handling equipment which could potentially affect sensitive safety-related I and C systems. Because much of the data collected to form the current EMC limits and guidance was collected from low-power equipment in relatively low EMI environments, the same guidance, applied to power electronic equipment, produces overly conservative estimations of the performance needed for EMC. Excessive modification in an attempt to bring the equipment into compliance with EMC limits may not be necessary. This paper provides a brief summary of current applicable EMC guidance and demonstrates a road map for the qualification of larger, more powerful devices which takes into account the entire EMC process, including design, testing, mapping of the installed location, and justification of EMC failures with the end goal being successful, timely, and cost-effective implementation of upgrades and compatibility with existing plant infrastructure (in the intended installation environment), even if equipment exceeds traditional operating envelopes. (authors)

42 ENGINEERING↗

Morphological and electrical properties of epoxy-based composites reinforced with exfoliated graphite

An experimental study has been carried out to prepare and characterize epoxy/amine-based composites filled with different percentages of partially exfoliated graphite (i.e. pEG) particles having an exfoliation degree of 56% in order to analyze the effect of the filler amounts on the electrical properties of the resulting nanocomposites. Moreover, in order to fully investigate the direct relationship between the physical properties of the employed filler and the results of the electrical characterization, a structural and morphological characterization of the pEG samples is carried out by means of various type of analysis such as X-ray diffraction patterns, micro-Raman and Scanning Electron Microscopy (SEM) images. The DC electrical characterization reveals a percolation thresholds (EPT) that falls in the range [2–3] wt% and an electrical conductivity of about 0.66 S/m at the highest filler loading (6.5 wt%). From the analysis of the percolative curve it is possible to derive the percolation law parameters and in particular the critical exponent t, whose value (i.e. 1.2) reflects an effective 2D organization of the percolating structure consistent with the type of filler used (2-dimensional). Finally, an extensive analysis concerning the electrical properties in the frequency domain has been carried out in order to evaluate the effectiveness of pEG-loaded composites in terms of electromagnetic interference compatibility (EMC) and their applicability as radar absorbers materials (RAMs).

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Task 4 - EMI/RFI Issues Potentially Impacting Electromagnetic Compatibility of I&C Systems (NRCHQ6014D0015)

The U.S. Nuclear Regulatory Commission’s (NRC’s) regulations in Part 50, “Domestic Licensing of Production and Utilization Facilities,” of Title 10 of the Code of Federal Regulations (10 CFR Part 50) state that structures, systems, and components important to safety in a nuclear power plant are to be designed to accommodate the effects of environmental conditions (i.e., remain functional under all postulated service conditions) and that design control measures such as testing are to be used to check the adequacy of design. Regulatory Guide (RG) 1.180 was developed to provide guidance to licensees and applicants on methods acceptable to the NRC staff for complying with the NRC’s regulations on design, installation, and testing practices for addressing the effects of electromagnetic and radio-frequency interference (EMI/RFI) and power surges on safety-related instrumentation and control (I&C) systems. The first revision of RG 1.180 was issued in January 2000 and a second revision was issued in October 2003*. The second revision differed from the first revision in endorsing Military Standard (MIL-STD)-461E and the International Electrotechnical Commission (IEC) Standard (Std) 61000 series of EMI/RFI test methods, extending the guidance to cover signal line testing, incorporating frequency ranges where portable communications devices are experiencing increasing use, and relaxing the operating envelopes (test levels) when experience and confirmatory research warranted. It also offered exemptions from specific test criteria based on technical considerations such as plant conditions and the intended location of the safety-related I&C equipment. Since the last revision, new requirements have been identified, associated RGs have been created and updated, and additional industry guidance has been developed. Additionally, the operational environment has changed with the increase in wireless communication technology for both personal (smartphone) and industrial (remote I&C) purposes. Also, specific concerns and issues with testing methods and methodologies have been identified that must be addressed. Further, most of the standards that serve as the basis for the RG have been revised. Therefore, the NRC’s Office of Regulatory Research has contracted with Oak Ridge National Laboratory (ORNL) to incorporate new information and resolve the identified issues under NRC-HQ-60-14-D-0015, “Update to RG 1.180, Revision 2, Guidelines for Evaluating Electromagnetic and Radio-Frequency Interference in Safety-Related Instrumentation and Control Systems.” The ultimate goal of this project is to provide NRC the technical basis for developing and publishing a new revision of the RG. The focus of Task 4 was for ORNL to identify and address any new or additional EMI/RFI issues that could potentially impact the EMC of I&C systems. More specifically, ORNL was to evaluate the impact of any new issue on safety equipment in their local environments and then determine whether the issues should be included and discussed in the revision to RG 1.180 that is currently under way.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗