Search NASA⌕ Search

SEARCH · Search NASA

Results for “EMCD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Determination of magnetic parameters in La{sub 0.7}Sr{sub 0.3}MnO{sub 3}/SrTiO{sub 3} thin films using EMCD

It is well known that the magnetic state of the La{sub 0.7}Sr{sub 0.3}MnO{sub 3} (LSMO) thin-film heterostructure is strongly correlated with the lattice, spin, orbital, and charge states, since these influence the electric and magnetic transport properties even on the unit-cell level. Therefore, understanding the material's magnetic properties on the nanoscale is important for the development of novel applications. The recently developed electron magnetic-circular dichroism (EMCD) technique allows the determination of atomic site-specific magnetic information via the use of transmitted electrons; however, its sensitivity is not high enough to quantitatively acquire magnetic information in many weak magnetism systems. Here, we utilized a dynamical diffraction-effect assisted EMCD technique to quantitatively determine the spin and orbital magnetic moment of LSMO/SrTiO{sub 3} thin films on the nanometer scale using a transmission electron microscope. Further, data processing was optimized to enhance the intensity of the EMCD signals for manganese, which have very weak magnetism at room temperature. High signal-to-noise ratio and accurate quantitative magnetic measurement are eventually achieved. Finally, the spin magnetic moments (0.73 ± 0.26 μ{sub B}) are derived, and we also limited the ratio of the orbital to spin magnetic moment within an interval of (−0.03, 0.01). Our results not only present the nanoscale magnetic parameters of LSMO/SrTiO{sub 3}, but also demonstrate how the measurement limit of the spin (or orbital) magnetic moment can be achieved, which is via the developed dynamical diffraction effect assisted EMCD technique.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic site sensitivity of the energy loss magnetic chiral dichroic spectra of complex oxides

The quantitative analysis of magnetic oxide core level spectra can become complicated when the magnetic atoms are located at several nonequivalent atomic sites in the crystal. This is, for instance, the case for Fe atoms in magnetite, which are located in tetrahedral and octahedral atomic sites; in this case, the x-ray magnetic circular dichroic (XMCD) spectra recorded at the L{sub 2,3} edge of Fe contain contributions from the different nonequivalent atomic sites, which unfortunately cannot be separated. Energy loss magnetic chiral dichroic (EMCD) spectra are the transmission electron microscope analogies of the XMCD spectra. One of the important differences between these two techniques of magnetic analysis is that EMCD uses a fast electron beam instead of polarized light. The fast electrons behave like Bloch states in the sample, and the fine structure of the EMCD spectra is strongly influenced by channeling and dynamical diffraction effects. These effects can be adjusted by changing the experimental configuration. We use theoretical calculations, which include dynamical diffraction effects and in which electronic transitions are treated in the atomic multiplet formalism, to show that the relative weight of the Fe atoms in different nonequivalent atomic sites can be changed by a proper choice of the position of the detector and of the magnetite sample orientation and thickness. We conclude that EMCD spectra could be used to isolate the magnetic contribution of atoms in each of the nonequivalent atomic sites, which would not be possible with XMCD techniques.

36 MATERIALS SCIENCE↗

Achieving atomic resolution magnetic dichroism by controlling the phase symmetry of an electron probe

The calculations presented here reveal that an electron probe carrying orbital angular momentum is just a particular case of a wider class of electron beams that can be used to measure electron magnetic circular dichroism (EMCD) with atomic resolution. It is possible to obtain an EMCD signal with atomic resolution by simply breaking the symmetry of the electron probe phase front using the aberration-corrected optics of a scanning transmission electron microscope. The probe’s required phase distribution depends on the sample’s magnetic symmetry and crystal structure. The calculations indicate that EMCD signals that use the electron probe’s phase are as strong as those obtained by nanodiffraction methods.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Circular dichroism in the electron microscope: Progress and applications (invited)

According to theory, x-ray magnetic circular dichroism in a synchrotron is equivalent to energy loss magnetic chiral dichroism (EMCD) in a transmission electron microscope (TEM). After a synopsis of the development of EMCD, the theoretical background is reviewed and recent results are presented, focusing on the study of magnetic nanoparticles for ferrofluids and Heusler alloys for spintronic devices. Simulated maps of the dichroic strength as a function of atom position in the crystal allow evaluating the influence of specimen thickness and sample tilt on the experimental EMCD signal. Finally, the possibility of direct observation of chiral electronic transitions with atomic resolution in a TEM is discussed.

36 MATERIALS SCIENCE↗

Quantitative analysis of magnetic spin and orbital moments from an oxidized iron (1 1 0) surface using electron magnetic circular dichroism

Understanding the ramifications of reduced crystalline symmetry on magnetic behavior is a critical step in improving our understanding of nanoscale and interfacial magnetism. However, investigations of such effects are often controversial largely due to the challenges inherent in directly correlating nanoscale stoichiometry and structure to magnetic behavior. Here, we describe how to use Transmission Electron Microscope (TEM) to obtain Electron Magnetic Circular Dichroism (EMCD) signals as a function of scattering angle to locally probe the magnetic behavior of thin oxide layers grown on an Fe (1 1 0) surface. Experiments and simulations both reveal a strong dependence of the magnetic orbital to spin ratio on its scattering vector in reciprocal space. We exploit this variation to extract the magnetic properties of the oxide cladding layer, showing that it locally may exhibit an enhanced orbital to spin moment ratio. This finding is supported here by both spatially and angularly resolved EMCD measurements, opening up the way for compelling investigations into how magnetic properties are affected by nanoscale features.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Aberrated electron probes for magnetic spectroscopy with atomic resolution: Theory and practical aspects

It was recently proposed that electron magnetic circular dichroism (EMCD) can be measured in scanning transmission electron microscopy (STEM) with atomic resolution by tuning the phase distribution of a electron beam. Here, we describe the theoretical and practical aspects for the detection of out-of-plane and in-plane magnetization utilizing atomic size electron probes. Here we present the calculated optimized astigmatic probes and discuss how to achieve them experimentally.

47 OTHER INSTRUMENTATION↗

Probing the localization of magnetic dichroism by atomic-size astigmatic and vortex electron beams

We report localization of a magnetic dichroic signal on atomic columns in electron magnetic circular dichroism (EMCD), probed by beam distorted by four-fold astigmatism and electron vortex beam. With astigmatic probe, magnetic signal to noise ratio can be enhanced by blocking the intensity from the central part of probe. However, the simulations show that for atomic resolution magnetic measurements, vortex beam is a more effective probe, with much higher magnetic signal to noise ratio. For all considered beam shapes, the optimal SNR constrains the signal detection at low collection angles of approximately 6–8 mrad. Irrespective of the material thickness, the magnetic signal remains strongly localized within the probed atomic column with vortex beam, whereas for astigmatic probes, the magnetic signal originates mostly from the nearest neighbor atomic columns. Due to excellent signal localization at probing individual atomic columns, vortex beams are predicted to be a strong candidate for studying the crystal site specific magnetic properties, magnetic properties at interfaces, or magnetism arising from individual atomic impurities.

36 MATERIALS SCIENCE↗

Detecting magnetic ordering with atomic size electron probes

While magnetism originates at the atomic scale, the existing spectroscopic techniques sensitive to magnetic signals only produce spectra with spatial resolution on a larger scale. However, recently, it has been theoretically argued that atomic size electron probes with customized phase distributions can detect magnetic circular dichroism. Here, we report a direct experimental real-space detection of magnetic circular dichroism in aberration-corrected scanning transmission electron microscopy (STEM). Using an atomic size-aberrated electron probe with a customized phase distribution, we reveal the checkerboard antiferromagnetic ordering of Mn moments in LaMnAsO by observing a dichroic signal in the Mn L-edge. The novel experimental setup presented here, which can easily be implemented in aberration-corrected STEM, opens new paths for probing dichroic signals in materials with unprecedented spatial resolution.

36 MATERIALS SCIENCE↗