Search NASA⌕ Search

SEARCH · Search NASA

Results for “EMIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

EMI Mitigation of a Ćuk-Based Power-Electronic System Using Switching-Sequence-Based Control

Switching-sequence-based control (SBC) laws when designed based on topological switching behavior can have positive effects on slow- and fast-scale dynamics of a power-electronic system (PES). The slow-scale control can encompass fast PES state regulation and tracking, based on predefined objective, while fastscale control can address differential-mode (DM) and commonmode (CM) spectral-peak energy associated with PES switching operation. Such control laws may offer enhanced programmability to conventional PES design where bulky electromagnetic interference (EMI) filters have been traditionally used to reduce EMI of switching power converters to meet EMI regulatory standards. An EMI filter is always a less programmable solution since it is usually designed for the worst-case EMI mitigation and usually overkill for a PES operating under reduced load condition. The control scheme outlined in this article offers EMI mitigation across wide operating regions without compromising PES regulation. Moreover, it does so by use of switching sequences that guarantee the reachability of the PES dynamics using an advanced Lyapunov-function-based approach. SBC is a powerful tool to generate control actions for a PES based on multivariate PES state constraints. Hence, contemporary EMI regulatory standards are used as constraints in the SBC formulation to operate the PES under wide operating regime while autonomously mitigating the EMI levels. The work may be of paramount importance for operating the ultra-fast-transition recent wide-bandgap semiconductor devices like GaN–FET and SiC MOSFET under higher power with increasing switching frequencies, which is usually desirable for increased power density and reduced switching losses. Here, a hardware Cuk–PES operated ´ with GaN–FETs is fabricated and is used for case illustration. It is shown by experimental results how SBC mitigate DM and CM EMI noise of the PES while maintaining regulation even for the higher order nonminimum phase PES, while reducing sensor requirements using state observer derived from the switching model of the PES.

42 ENGINEERING↗

Coupled Inductor Design for Interleaved Three-level Active Neutral Point Clamped Inverters Considering EMI Noise Reduction

This paper presents the coupled inductor design for interleaved three-level active neutral point clamped (ANPC) inverter considering electromagnetic interference (EMI) noise reduction. Compared to two-level case, the scenarios involved in the three-level space vector modulation (SVM) are more complicated when analyzing the volt-seconds of the coupled inductor for paralleled three-level inverter. At system level, the purpose of converter interleaving is to reduce EMI noise and ripple current in most applications, and coupled inductor design should consider the needs of EMI noise reduction and EMI filter design. These issues are discussed in this paper. The relationship between circulating current and EMI noise is illustrated. EMI filter corner frequency as a function of interleaving angle is analytically derived, and optimal interleaving angle for maximum common-mode (CM) filter and differential-mode (DM) filter corner frequencies is discussed. Coupled inductor design methodology for interleaved three-level inverters with SVM is then presented. Experiments on two interleaved ANPC inverters are conducted. The results verify the coupled inductor design. With the derived optimal interleaving angle, the CM and DM EMI noise are significantly reduced.

Chen, Ruirui↗

Estimation of soil classes and their relationship to grapevine vigor in a Bordeaux vineyard: advancing the practical joint use of electromagnetic induction (EMI) and NDVI datasets for precision viticulture

Working within a vineyard in the Pessac Léognan Appellation of Bordeaux, France, this study documents the potential of using simple statistical methods with spatially-resolved and increasingly available electromagnetic induction (EMI) geophysical and normalized difference vegetation index (NDVI) datasets to accurately estimate Bordeaux vineyard soil classes and to quantitatively explore the relationship between vineyard soil types and grapevine vigor. First, co-located electrical tomographic tomography (ERT) and EMI datasets were compared to gain confidence about how the EMI method averaged soil properties over the grapevine rooting depth. Then, EMI data were used with core soil texture and soil-pit based interpretations of Bordeaux soil types (Brunisol, Redoxisol, Colluviosol and Calcosol) to estimate the spatial distribution of geophysically-identified Bordeaux soil classes. A strong relationship (r = 0.75, p < 0.01) was revealed between the geophysically-identified Bordeaux soil classes and NDVI (both 2 m resolution), showing that the highest grapevine vigor was associated with the Bordeaux soil classes having the largest clay fraction. The results suggest that within-block variability of grapevine vigor was largely controlled by variability in soil classes, and that carefully collected EMI and NDVI datasets can be exceedingly helpful for providing quantitative estimates of vineyard soil and vigor variability, as well as their covariation. The method is expected to be transferable to other viticultural regions, providing an approach to use easy-to-acquire, high resolution datasets to guide viticultural practices, including routine management and replanting.

54 ENVIRONMENTAL SCIENCES↗

Lightweight graphene nanoplatelet/boron carbide composite with high EMI shielding effectiveness

Lightweight graphene nanoplatelet (GNP)/boron carbide (B{sub 4}C) composites were prepared and the effect of GNPs loading on the electromagnetic interference (EMI) shielding effectiveness (SE) has been evaluated in the X-band frequency range. Results have shown that the EMI SE of GNP/B{sub 4}C composite increases with increasing the GNPs loading. An EMI SE as high as 37 ∼ 39 dB has been achieved in composite with 5 vol% GNPs. The high EMI SE is mainly attributed to the high electrical conductivity, high dielectric loss as well as multiple reflections by aligned GNPs inside the composite. The GNP/B{sub 4}C composite is demonstrated to be promising candidate of high-temperature microwave EMI shielding material.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A Comprehensive Approach towards Multi-Objective EMI Filter Design Optimization in High-Frequency SiC-Based Motor Drives

With rapid penetration of high-frequency, highdensity power electronics into the industry, controlling the system generated EMI becomes one of the major design challenges. Designing practical optimized EMI filters require simultaneous consideration of multiple aspects - including electromagnetic couplings, magnetic materials, practical component parasitics and their impacts at high-frequencies, and also the overall manufacturing costs. The multi-dimensional nature of the problem often results in overcompensated designs that hurt the system efficiency and power density. This paper focuses on a comprehensive design platform (developed in MATLAB) towards designing high-density, optimized, highly efficient EMI filters by analyzing the generated noise spectrum and evaluating a vast array of potential solutions before outputting an optimized filter solution. The proposed tool includes database-based component selection, optimal topology selection, multistage filter design, overall optimization for volume, mass, cost and total loss. The proposed filter has been thoroughly evaluated in a PSIM simulation environment emulating the hardware in CRD300DA12EXM3, a 300kW three-phase inverter from Wolfspeed with an RL load representing a motor drive application. Furthermore, a 20kHz switching frequency is chosen and impacts of the motor high-frequency characteristics on the generated EMI noise spectrum of the overall system have been analyzed.

42 ENGINEERING↗

Best Practices to Support EMIS Operation at Federal Facilities

The Federal Energy Management Program (FEMP) promotes best practices for impactful utilization of Energy Management Information Systems (EMIS) at federal facilities, as detailed in the EMIS Technical Resources Report. A series of best practices documents was created by FEMP to help accelerate the market adoption and use of EMIS in the federal sector. This document highlights best practices for supporting EMIS use at federal facilities.

EMIS↗

Parasitic Effects of Grounding Paths on Common-Mode EMI Filter's Performance in Power Electronics Systems

High-frequency common-mode (CM) electromagnetic-interference (EMI) noise is difficult to suppress in electronics systems. EMI filters are used to suppress CM noise, but their performance is greatly affected by the parasitic effects of the grounding paths. In this paper, the parasitic effects of the grounding paths on an EMI filter's performance are investigated in a motor-drive system. The effects of the mutual inductance between two grounding paths are explored. Guidelines for the grounding of CM EMI filters are derived. Simulations and experiments are finally carried out to verify the theoretical analysis.

42 ENGINEERING↗

Electromagnetic Induction (EMI) Data, 2024, Trail Creek, Colorado

This dataset contains Electromagnetic Induction (EMI) data collected at Trail Creek, Colorado, in 2024. EMI surveys were conducted to investigate the spatial distribution of electrical conductivity in the subsurface, providing insights into soil moisture and subsurface geological features. The surveys were performed along multiple transects to capture variations in conductivity influenced by changes in soil composition, moisture content, and underlying geological structures. This dataset complements other geophysical data collected in the region, including Electrical Resistivity Tomography (ERT) and Terrestrial LiDAR Scanning (TLS), providing a detailed understanding of the subsurface and its impact on surface vegetation and hydrological processes. The data are valuable for environmental geophysics, ecological research, and hydrological modeling in mountainous ecosystems. The files include: - data.zip: the raw EMI data (.csv) - inversion.zip: the inverted resistivity model (.csv and .kml) - kriging.zip: the kriging resistivity model (.csv, .tif, .kmz) - flmd.csv: file level metadata file describing all files within this dataset - dd.csv: data dictionary file describing the column headers within CSV files This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

CMD Mini-Explorer↗

Report of the EMI Testing of the Johnson Noise Thermometry System

This report summarizes the Electromagnetic Interference (EMI) testing of the Johnson Noise Thermometry System developed at ORNL. The EMI performance is very important for Johnson Noise Thermometry because it requires accurate measurement of a very small noise signal that is amplified 10,000 times. Any interference in the form on pickup from external signal sources from such as fluorescent lighting ballasts, motors, etc. can skew the measurement. Testing is therefore very important in determining the effects of these external noise sources. Results from testing in several environments with various sources of EMI are presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EMIS Agent Simulation Model (Electricity Markets Investment Suite) [SWR-19-56]

The Electricity Markets Investment Suite Agent-based Simulation (EMIS-AS) model is an agent-based model developed at NREL for simulating annual investment and retirement decisions of heterogeneous investors in the electricity sector. EMIS-AS is designed to capture the evolution of the electricity generation portfolio resulting from the interactions of heterogeneous investors under different policy and market designs. EMIS-AS not only allows end-users to customize market products and rules, but also to capture investors' heterogeneous financing parameters, technology preferences, beliefs about the future (forecasts), ability to update those forecasts, and risk preferences under uncertainty.

Anwar, Mahammad Bashar↗

Using EMIS to Identify Top Opportunities for Commercial Building Efficiency

Energy Management and Information Systems (EMIS) comprise a broad family of tools and services to manage commercial building energy use. These technologies offer a mix of capabilities to store, display, and analyze energy use and system data, and in some cases, provide control. EMIS technologies enable 10–20 percent site energy savings in best practice implementations. Energy Information System (EIS) and Fault Detection and Diagnosis (FDD) systems are two key technologies in the EMIS family. Energy Information Systems are broadly defined as the web-based software, data acquisition hardware, and communication systems used to analyze and display building energy performance. At a minimum, an EIS provides daily, hourly or sub-hourly interval meter data at the whole-building level, with graphical and analytical capability. Fault Detection and Diagnosis systems automatically identify heating, ventilation, and air-conditioning (HVAC) system or equipment-level performances issues, and in some cases are able to isolate the root causes of the problem. They use computer algorithms to continuously analyze system-level operational data to detect faults and diagnose their causes. Many FDD tools integrate the trend log data from a Building Automation System (BAS) but otherwise are stand-alone software packages; other types of FDD tools are implemented as “on-board” equipment-embedded diagnostics. (This document focuses on the former.) Analysis approaches adopted in FDD technologies span a variety of techniques from rule-based methods to process history-based approaches. FDD tools automate investigations that can be conducted via manual data inspection by someone with expert knowledge, thereby expanding accessibility and breath of analysis opportunity, and also reducing complexity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of the Feasibility of UAS-Based EMI Sensing for Underground Utilities Detection and Mapping

This paper investigates the feasibility of using a linear current sensing (LCS) technique integrated on an unmanned aerial system (UAS) for detecting and mapping underground infrastructure rapidly and cost-effectively. The LCS technique is based on data from a wide band of electromagnetic induction frequencies (50 kHz to 2 MHz) using a vector magnetic field gradiometer. This technique takes advantage of a slowly decaying secondary magnetic field in order to achieve greater standoff detection distance ($\frac{1}{R^2}$ vs. $\frac{1}{R^6}$ for compact metallic targets during EMI sensing, where R is the distance from a target to the sensor). These secondary magnetic fields are produced by the excite current on long conductors, allowing detection at a distance of 10 meters or more. The system operates between tens of kHz to a few MHz and uses either an active EMI source or existing EM fields to excite this linear current on a long metallic subsurface target. Once excited, these linear currents produce a secondary magnetic field that is detected with an above ground triaxial magnetic field gradiometer. By moving and tracking its geolocation, the system outputs rich datasets sufficient to support high-fidelity forward and inverse EMI models for estimating the depth and orientation of deep underground long linear metallic infrastructure. The system’s hardware and its integration to a UAS system are outlined, along with the formulation of LCS theory, and numerical and experimental data are presented. The results illustrate that the LCS technique offers large standoff detection, is adaptable to UAS, and could be used effectively for detecting deep underground infrastructure such as wires and pipes.

54 ENVIRONMENTAL SCIENCES↗

Shielded multi-stage EMI noise filter

Electromagnetic interference (EMI) noise filter embodiments and methods for filtering are provided herein. EMI noise filters include multiple signal exclusion enclosures. The multiple signal exclusion enclosures contain filter circuit stages. The signal exclusion enclosures can attenuate noise generated external to the enclosures and/or isolate noise currents generated by the corresponding filter circuits within the enclosures. In certain embodiments, an output of one filter circuit stage is connected to an input of the next filter circuit stage. The multiple signal exclusion enclosures can be chambers formed using conductive partitions to divide an outer signal exclusion enclosure. EMI noise filters can also include mechanisms to maintain the components of the filter circuit stages at a consistent temperature. For example, a metal base plate can distribute heat among filter components, and an insulating material can be positioned inside signal exclusion enclosures.

42 ENGINEERING↗

A Primer on Organizational Use of Energy Management and Information Systems (EMIS)

The document provides a high-level overview of Energy Management and Information Systems (EMIS), which are combined hardware and software products that comprise a broad family of tools and services to manage commercial building energy use. It provides a common reference that can be used to understand key distinguishing factors and core attributes of different solutions within the family of EMIS technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Primer on Organizational Use of Energy Management and Information Systems (EMIS), Second edition

The document provides a high-level overview of Energy Management and Information Systems (EMIS), which are combined hardware and software products that comprise a broad family of tools and services to manage commercial building energy use. It provides a common reference that can be used to understand key distinguishing factors and core attributes of different solutions within the family of EMIS technologies. This is a 2021 update to the original 2015 edition.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Management and Information Systems (EMIS) Specification and Procurement Support Materials

This annotated Request for Proposal (RFP) template includes an Energy Management and Information System (EMIS) technology specification, an ongoing services specification, RFP evaluation criteria, and more. It is designed to guide building professionals through the specification, procurement, and selection of an EMIS or related building performance monitoring and diagnostic technology.

building performance↗