Search NASA⌕ Search

SEARCH · Search NASA

Results for “END EFFECTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Influence of capillary end effects on steady-state relative permeability estimates from direct pore-scale simulations

In this study, we investigate and characterize the influence of capillary end effects on steady-state relative permeabilities obtained in pore-scale numerical simulations of two-phase flows. Our study is motivated by the observation that capillary end effects documented in two-phase laboratory-scale experiments can significantly influence permeability estimates. While numerical simulations of two-phase flows in reconstructed pore-spaces are increasingly employed to characterize relative permeabilities, a phenomenon which is akin to capillary end effects can also arise in such analyses due to the constraints applied at the boundaries of the computational domain. We profile the relative strength of these capillary end effects on the calculation of steady-state relative permeabilities obtained within randomly generated porous micro-structures using a finite volume-based two-phase flow solver. Finally, we suggest a procedure to estimate the extent of the regions influenced by these capillary end effects, which in turn allows for the alleviation of bias in the estimation of relative permeabilities.

42 ENGINEERING↗

Determining the Efficiency of the Hanford Waste End Effecter through Proof of Concept Testing - 18165

The ability to effectively retrieve aged and hardened waste from leaking underground storage tanks at the Hanford Site is critical to achieving tank closure and Tank Farm mission success. DOE's Tank Operations Contractor, Washington River Protection Solutions (WRPS) is currently developing with Pacific Northwest National Laboratory (PNNL) a confined sluicing end effecter known as the Hanford Waste End Effecter (HWEE). The HWEE is a high-pressure rotating multi water-jet (for waste dislocation) with an eductor transfer system that is designed to both mobilize and extract the eroded waste settled on tank bottoms. This technology development is planned to be accomplished in four phases: 1) HWEE proof of concept testing using cold simulants (based on known Hanford tank waste hardness characteristics); 2) HWEE retrieval system development and testing using cold simulant; 3) full scale HWEE system testing using cold simulant; and 4) deployment into an actual Hanford Tank with the intent to successfully retrieve remaining waste in the tank. This paper discusses the viability of the HWEE based on how well it removed the simulated hardpan and the amount of liquid left in the test bed during Phase 1. Water usage and retrieval rate were closely monitored. This paper only discusses Phase 1 testing and results completed in October 2017. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-J-55: End-To-End Effectiveness Analysis of 3D Surface Image Guided Voluntary Breath-Holding Radiotherapy for Left Breast

Purpose To evaluate the effectiveness of using 3D-surface-image to guide breath-holding (BH) left-side breast treatment. Methods Two 3D surface image guided BH procedures were implemented and evaluated: normal-BH, taking BH at a comfortable level, and deep-inspiration-breath-holding (DIBH). A total of 20 patients (10 Normal-BH and 10 DIBH) were recruited. Patients received a BH evaluation using a commercialized 3D-surface- tracking-system (VisionRT, London, UK) to quantify the reproducibility of BH positions prior to CT scan. Tangential 3D/IMRT plans were conducted. Patients were initially setup under free-breathing (FB) condition using the FB surface obtained from the untaged CT to ensure a correct patient position. Patients were then guided to reach the planned BH position using the BH surface obtained from the BH CT. Action-levels were set at each phase of treatment process based on the information provided by the 3D-surface-tracking-system for proper interventions (eliminate/re-setup/ re-coaching). We reviewed the frequency of interventions to evaluate its effectiveness. The FB-CBCT and port-film were utilized to evaluate the accuracy of 3D-surface-guided setups. Results 25% of BH candidates with BH positioning uncertainty > 2mm are eliminated prior to CT scan. For >90% of fractions, based on the setup deltas from3D-surface-trackingsystem, adjustments of patient setup are needed after the initial-setup using laser. 3D-surface-guided-setup accuracy is comparable as CBCT. For the BH guidance, frequency of interventions (a re-coaching/re-setup) is 40%(Normal-BH)/91%(DIBH) of treatments for the first 5-fractions and then drops to 16%(Normal-BH)/46%(DIBH). The necessity of re-setup is highly patient-specific for Normal-BH but highly random among patients for DIBH. Overall, a −0.8±2.4 mm accuracy of the anterior pericardial shadow position was achieved. Conclusion 3D-surface-image technology provides effective intervention to the treatment process and ensures favorable day-to-day setup accuracy. DIBH setup appears to be more uncertain and this would be the patient group who will definitely benefit from the extra information of 3D surface setup.

60 APPLIED LIFE SCIENCES↗

Real-time POD-CFD Wind-Load Calculator for PV Systems

The primary objective of this project is to create an accurate web-based real-time wind-load calculator. This is of paramount importance for (1) the rapid and accurate assessments of the uplift and downforce loads on a PV mounting system, (2) identifying viable solutions from available mounting systems, and therefore helping reduce the cost of mounting hardware and installation. Wind loading calculations for structures are currently performed according to the American Society of Civil Engineers/ Structural Engineering Institute Standard ASCE/SEI 7; the values in this standard were calculated from simplified models that do not necessarily take into account relevant characteristics such as those from full 3D effects, end effects, turbulence generation and dissipation, as well as minor effects derived from shear forces on installation brackets and other accessories. This standard does not include provisions that address the special requirements of rooftop PV systems, and attempts to apply this standard may lead to significant design errors as wind loads are incorrectly estimated. Therefore, an accurate calculator would be of paramount importance for the preliminary assessments of the uplift and downforce loads on a PV mounting system, identifying viable solutions from available mounting systems, and therefore helping reduce the cost of the mounting system and installation. The challenge is that although a full-fledged three-dimensional computational fluid dynamics (CFD) analysis would properly and accurately capture the complete physical effects of air flow over PV systems, it would be impractical for this tool, which is intended to be a real-time web-based calculator. CFD routinely requires enormous computation times to arrive at solutions that can be deemed accurate and grid-independent even in powerful and massively parallel computer platforms.

14 SOLAR ENERGY↗

Viscous Dissipation and Apparent Permeability of Gas Flow in Nanoporous Media

The nanopore confinement effect can increase the mobility for gas flow in shale rocks, and the apparent permeability is usually adopted to account for this effect. However, most of the apparent permeability calculation models are derived based on straight channels (capillaries) and neglect the influence of end effect. The end effect is caused by the bending of streamlines which yields more viscous dissipation and additional flow resistance for gas flow in nanoporous media. Here, for the first time the viscous dissipation for gas flow in nanoporous media is analyzed. In addition, an improved apparent permeability calculation model is proposed based on the Beskok-Karniadakis (B-K) model by introducing the influence of end effect, which is characterized by the ratio of the length to the width of a short channel (L/H). The accuracy of this model is validated by lattice Boltzmann simulations of gas flow in three different geometries: an infinite-length straight channel, a finite-length straight channel, and nanoporous media. For the infinite-length straight channel, there is no end effect therefore both the B-K model and the improved model can well predict the apparent permeability. However, for the finite-length straight channel and nanoporous media, the original B-K model overestimates the gas apparent permeability as it neglects the influence of end effect, while the improved model can still well predict the gas apparent permeability. In summary, the improved apparent permeability calculation model is more reasonable in predicting gas mobility in nanoporous media.

58 GEOSCIENCES↗

Dominant end-tunneling effect in two distinct Luttinger liquids coexisting in one quantum wire

Luttinger liquids occupy a notable place in physics as one of the most understood classes of quantum many-body systems. The experimental mission of measuring its main prediction, power laws in observable quantities, has already produced a body of exponents in different semiconductor and metallic structures. Here, we combine tunneling spectroscopy with density-dependent transport measurements in the same quantum wires over more than two orders of magnitude in temperature to very low electron temperatures down to ∼40 mK. This reveals that, when the second 1D subband becomes populated, the temperature dependence splits into two ranges with different exponents in the power-law dependence of the conductance, both dominated by the finite-size effect of the end-tunneling process. This result demonstrates the importance of measuring the Luttinger parameters as well as the number of modes independently through spectroscopy in addition to the transport exponent in the characterization of Luttinger liquids. This opens a pathway to unambiguous interpretation of the exponents observed in quantum wires.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of end reflections on conversion efficiency of coaxial relativistic backward wave oscillator

This paper theoretically investigates the effect of end reflections on the operation of the coaxial relativistic backward wave oscillator (CRBWO). It is found that the considerable enhancement of the end reflection at one end increases the conversion efficiency, but excessively large end reflections at both ends weaken the asynchronous wave-beam interaction and thus reduce the conversion efficiency. Perfect reflection at the post end significantly improves the interaction between the electron beam and the asynchronous harmonic so that the conversion efficiency is notably increased. Based on the theoretical research, the diffraction-CRBWO with the generated microwave diffracted and output through the front end of the coaxial slow wave structure cavity is proposed. The post end is conductively closed to provide the perfect reflection. This promotes the amplitude and uniformity of the longitudinal electric field on the beam transmission line and improves the asynchronous wave-beam interaction. In numerical simulations under the diode voltage and current of 450 kV and 5.84 kA, microwave generation with the power of 1.45 GW and the conversion efficiency of 55% are obtained at the frequency of 7.45 GHz.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Meta-metallic coils and resonators: Methods for high Q-value resonant geometries

A novel method of decreasing ohmic losses and increasing Q-value in metallic resonators at high frequencies is presented. The method overcomes the skin-depth limitation of rf current flow cross section. The method uses layers of conductive foil of thickness less than a skin depth and capacitive gaps between layers. The capacitive gaps can substantially equalize the rf current flowing in each layer, resulting in a total cross-sectional dimension for rf current flow many times larger than a skin depth. Analytic theory and finite-element simulations indicate that, for a variety of structures, the Q-value enhancement over a single thick conductor approaches the ratio of total conductor thickness to skin depth if the total number of layers is greater than one-third the square of the ratio of total conductor thickness to skin depth. The layer number requirement is due to counter-currents in each foil layer caused by the surrounding rf magnetic fields. We call structures that exhibit this type of Q-enhancement “meta-metallic.” In addition, end effects due to rf magnetic fields wrapping around the ends of the foils can substantially reduce the Q-value for some classes of structures. Foil structures with Q-values that are substantially influenced by such end effects are discussed as are five classes of structures that are not. We focus particularly on 400 MHz, which is the resonant frequency of protons at 9.4 T. Simulations at 400 MHz are shown with comparison to measurements on fabricated structures. The methods and geometries described here are general for magnetic resonance and can be used at frequencies much higher than 400 MHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An extended JBN method of determining unsteady-state two-phase relative permeability

Relative permeability is the reduction of permeability of porous media when subjected to multiphase flow and a key parameter in subsurface hydrology. The JBN method is a well-known method of obtaining relative permeability, which measures the overall pressure drop and the effluent phase ratio versus time during two-phase displacements. By assuming no capillary pressure or gravity, the JBN method obtains the relative permeabilities to both phases at the core outlet. Since data across a range of saturations are acquired in a relatively short time, this method is widely used. This work extends the JBN method by having (1) section-wise pressure drop measurements between the core inlet, four pressure taps on the core and the outlet, (2) local saturation measurements, and (3) local phase fluxes. With these data, the extended JBN method can determine relative permeabilities to both phases at each pressure tap of the core (not just at the core outlet). The JBN extension is shown using a data set where CO 2 invades a brine-filled core. From this it is found that the advantages of the extended JBN method over the regular JBN method are: (1) four times more data are obtained, and (2) data are more accurate because the capillary end effect is experimentally avoided. Avoiding the end effect results in tripling the saturation range, and obtaining relative permeabilities that are consistent with steady-state measurements and roughly 40% higher than those from the regular JBN method.

54 ENVIRONMENTAL SCIENCES↗

Effects of end group functionalization and level alignment on electron transport in molecular devices

The effect of metal-molecule coupling on electron transport is examined in the prototypical case of alkane chains sandwiched between gold contacts and bridged by either amine or thiol groups. The results show that end group functionalization plays a crucial role in controlling electron transport, and that the symmetries and spatial extent of orbitals near the Fermi level control the conductivity rather than the strength of the bonding. For amine/Au and thiol/Au junctions, a crossover in conductivity with increasing bias is predicted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-T-32: Evaluation of the Performance of a Multiple-Array-Diode Detector for Quality Assurance Tests in High-Dose-Rate Brachytherapy with Ir-192 Source

Purpose: To evaluate the performance of a two-dimensional (2D) array-diode- detector for geometric and dosimetric quality assurance (QA) tests of high-dose-rate (HDR) brachytherapy with an Ir-192-source. Methods: A phantom setup was designed that encapsulated a two-dimensional (2D) array-diode-detector (MapCheck2) and a catheter for the HDR brachytherapy Ir-192 source. This setup was used to perform both geometric and dosimetric quality assurance for the HDR-Ir192 source. The geometric tests included: (a) measurement of the position of the source and (b) spacing between different dwell positions. The dosimteric tests include: (a) linearity of output with time, (b) end effect and (c) relative dose verification. The 2D-dose distribution measured with MapCheck2 was used to perform the previous tests. The results of MapCheck2 were compared with the corresponding quality assurance testes performed with Gafchromic-film and well-ionization-chamber. Results: The position of the source and the spacing between different dwell-positions were reproducible within 1 mm accuracy by measuring the position of maximal dose using MapCheck2 in contrast to the film which showed a blurred image of the dwell positions due to limited film sensitivity to irradiation. The linearity of the dose with dwell times measured from MapCheck2 was superior to the linearity measured with ionization chamber due to higher signal-to-noise ratio of the diode readings. MapCheck2 provided more accurate measurement of the end effect with uncertainty < 1.5% in comparison with the ionization chamber uncertainty of 3%. Although MapCheck2 did not provide absolute calibration dosimeter for the activity of the source, it provided accurate tool for relative dose verification in HDR-brachytherapy. Conclusion: The 2D-array-diode-detector provides a practical, compact and accurate tool to perform quality assurance for HDR-brachytherapy with an Ir-192 source. The diodes in MapCheck2 have high radiation sensitivity and linearity that is superior to Gafchromic-films and ionization chamber used for geometric and dosimetric QA in HDR-brachytherapy, respectively.

60 APPLIED LIFE SCIENCES↗

Methods for separation of polymeric compounds

Recently two techniques using free solution electrophoresis to separate charged-uncharged polymer conjugates have proven successful: End Labeled Free Solution Electrophoresis (ELFSE) for DNA sequencing, and Free Solution Conjugate Electrophoresis (FSCE) for molar mass profiling of uncharged polymers. Previous attempts have been made to analyze experimental data generated by these new techniques for the electrophoresis of molecules with varying charge distributions. However, the importance of the ends of the polymers in determining the polymer's overall mobility was neglected in previous work. Through a careful investigation and a reanalysis of the experimental data, it is determined here that this “end effect” critically impacts the behavior of polymers and charged-uncharged polymer conjugates during electrophoresis. In this way, the invention provides for methods that exploit this “end effect” for the separation of polymeric molecules on the basis of size, including for example DNA separation and sequencing techniques.

Slater, Gary W.↗

Measurements of CO 2 ‐brine relative permeability in Berea sandstone using pressure taps and a long core

Abstract We measured CO 2 ‐brine relative permeability by performing five steady‐state primary drainage experiments in a 116 mD Berea sandstone core at 20°C and 10.34 MPa. We used a long (60.8 cm) core and four pressure taps to study and minimize end effects that can plague CO 2 ‐brine relative permeability measurements, and we obtained in situ saturation profiles using a medical X‐ray Computed Tomography (CT) scanner. We found that entrance and exit effects propagated ∼5 cm into the core, but the center sections of the core had uniform saturation. From the saturations and pressure drops, we obtained both CO 2 and brine relative permeability in the center sections. We also obtained CO 2 relative permeability at the entrance section where the brine saturation was lower and not uniform. The 15‐cm long exit section of the core had non‐uniform saturation and a measured pressure drop that was on the order of the capillary pressure and hence was unreliable for calculating relative permeability. We found that the CO 2 and brine relative permeabilities determined in five experiments were consistent with each other and followed two simple Corey‐type models that are similar to those seen in oil‐brine relative permeability measurements. We discuss why end effects are much greater in the CO 2 ‐brine system than in oil‐brine systems, and how this is a possible explanation of the low CO 2 relative permeabilities recently reported for the CO 2 ‐brine systems. © 2016 Society of Chemical Industry and John Wiley & Sons, Ltd.

Chen, Xiongyu↗

Exploring Engine Oil Reactivity Effects on End Gas Knock in a Direct-Injection Spark Ignition Engine

An experimental study was conducted in a direct-injection (DI) spark-ignited engine to determine the extent to which oil reactivity impacts combustion phasing and knock propensity. Three engine oils were examined: a baseline 20W30 oil from conventional base stock, a 5W30 oil from a synthetic base stock, and a jet oil from a hindered ester base stock. The engine was operated at a constant fueling rate of 24.7 mg/injection for two engine speed conditions (1500 and 2000 rpm) using two cam profile conditions (high and low lift), for a total of four operating conditions. Spark timing sweeps were conducted at each of the four operating conditions. Results were analyzed for an engine oil impact on combustion phasing, cycle-to-cycle variability, combustion duration, knock propensity, and knock intensity. No correlation between engine oil type and any of these performance metrics could be identified. Measurements showed that the oil consumption rate for this engine is low and comparable to engines compliant with U.S. Tier 1 and Tier 2 emissions standards, consuming 1.4 g/kg of fuel consumed (150 g for 20 hours of operation). Finally, the lack of a correlation between the oil type and engine performance can be attributed to this low level of oil consumption, resulting in very little interaction between the oil and the combustion chamber contents.

42 ENGINEERING↗