Search NASA⌕ Search

SEARCH · Search NASA

Results for “ENDF/B-VII.1”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Neutronic Characteristics of ENDF/B-VIII.0 Compared to ENDF/B-VII.1 for Light-Water Reactor Analysis

The Evaluated Nuclear Data File (ENDF)/B-VIII.0 data library was released in 2018. To assess the new data during development and shortly after release, many validation calculations were performed with static, room-temperature benchmarks. Recently, when performing validation of ENDF/B-VIII.0 for pressurized water reactor depletion calculations, a regression in performance compared to ENDF/B-VII.1 was observed. This paper documents extensive benchmark calculations for light-water reactors performed using continuous energy Monte Carlo code with ENDF/B-VII.1 and -VIII.0 and neutronic characteristics of ENDF/B-VIII.0 are discussed and compared to those of ENDF/B-VII.1. It is our recommendation that ENDF/B data library assessment should include reactor-specific benchmark assessments, including depletion cases, such that these types of regressions may be caught earlier in the data development cycle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Impact of Changes in ENDF/B-VII.1 and ENDF/B-VIII.0 235U Nuclear Data Indicated by NDSE Studies on LLNL Pulsed Sphere Simulations

A recent journal article by J.A. Gomez et al. measured gamma-ray die-off curves of three subcritical static highly-enriched uranium (HEU) assemblies driven by an external neutron source with a new detector system. This new detector system was developed for being used in dynamically driven subcritical assemblies as part of the Neutron Diagnosed Subcritical Experiments (NDSE) program. Simulations of these die-off curves with various nuclear data and comparison to experimental data indicated that a decrease of the ENDF/B-VII.1 235 U(n,inl) cross section by a factor 0.8 and 0.85 for ENDF/B-VIII.0 would lead to better predictions of experimental data. Here, we test the proposed changes with another type of measurement response, namely neutron-leakage spectra emitted in LLNL pulsed sphere measurements. These spheres were pulsed by 14-MeV neutrons produced via the D+T reaction in their center. The proposed changes in nuclear data have a distinctly smaller impact on predicting pulsed-sphere neutron-leakage spectra than for the die-off curves; they lead to a worsened prediction of the inelastic valley of LLNL pulsed-sphere neutron spectra indicating that the proposed change could constitute a compensating error. Changes in the inelastic angular distributions along with the cross section might be worthwhile to study

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verification of the ENDF/B-VII.1 Based MC 2 -3 Library Rev.1

The MC 2 -3 code, developed by Argonne National Laboratory under the DOE-NE NEAMS program, is a multigroup cross section generation code for fast reactor applications. Last year, the ENDF/B-VII.0 (E70) MC 2 -3 library, which has been extensively used, verified, and validated over a long period, was intensively reverified and updated to support the commercial grade dedication (CGD) requirement of the TerraPower Natrium project. This year, the ENDF/B-VII.1 (E71) MC 2 -3 library, the preliminary version of which was generated several years ago, was regenerated and rigorously verified to support the Natrium project as well as the completion of verification of the E71 library. The E71 library was verified using the process developed during the verification of the E70 library, including comparisons of cross sections with the NJOY-generated cross sections, comparisons of the resolved resonance cross sections with those using the PEDNF library, and comparison of total cross sections with the sum of partial cross sections. Additional verifications were conducted to ensure that the benchmark problem solutions with the E71 library are reasonable compared to the corresponding Monte Carlo solutions. Furthermore, the E71 gamma library was generated, which includes data for prompt gamma, delayed gamma, and delayed beta as well as neutron and gamma heating. The gamma library was verified at the level of individual isotopes. The EBR-II core solutions from MC 2 -3/ DIF3D and MCNP were compared, demonstrating that those solutions in terms of k-effective and assembly powers were in good agreement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nuclear Data Sensitivity Study for the EBR-II Fast Reactor Benchmark Using SCALE with ENDF/B-VII.1 and ENDF/B-VIII.0

The EBR-II benchmark, which was recently included in the International Handbook of Evaluated Reactor Physics Benchmark Experiments, served as a basis for assessing the performance of the SCALE code system for fast reactor analyses. A reference SCALE model was developed based on the benchmark specifications. Great agreement was observed between the eigenvalue calculated with this SCALE model and the benchmark eigenvalue. To identify potential gaps and uncertainties of nuclear data for the simulation of various quantities of interest in fast spectrum systems, sensitivity and uncertainty analyses were performed for the eigenvalue, reactivity effects, and the radial power profile of EBR-II using the two most recent ENDF/B nuclear data library releases. While the nominal results are consistent between the calculations with the different libraries, the uncertainties due to nuclear data vary significantly. The major driver of observed uncertainties is the uncertainty of the 235 U ( n,γ ) reaction. Since the uncertainty of this reaction is significantly reduced in the ENDF/B-VIII.0 library compared to ENDF/B-VII.1, the obtained output uncertainties tend to be smaller in ENDF/B-VIII.0 calculations, although the decrease is partially compensated by increased uncertainties in 235 U fission and ν ¯ .

42 ENGINEERING↗

Cumulative χ 2 Metric for VALID for ENDF/B-VII.1 and ENDF/B-VIII.0 in SCALE 6.3b9 [Slides]

Quantifying the performance of a new evaluation is difficult and doing so for a new library is significantly more challenging. Cumulative χ 2 metric is an established approach to comparing distributions. In this case, C/E results from different libraries. Andrei Trkov and Roberto Capote have published cumulative χ 2 results for ENDF/B-VIII.0. Cumulative χ 2 metric was recently calculated for VALID library maintained at ORNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of the SCALE/Polaris-PARCS Code Procedure with the ENDF/B-VII.1 AMPX 56-Group Library: Pressurized Water Reactor

This study was conducted to validate the SCALE/Polaris v6.3.0–PARCS v3.4.2 code procedure with the Evaluated Nuclear Data File (ENDF)/B-VII.1 AMPX 56-group library for pressurized water reactor (PWR) analysis, by comparing simulated results with measured data for critical experiments and operating PWRs. Uncertainties of the SCALE/Polaris–PARCS code procedure for PWR analysis were evaluated in the validation for the PWR key nuclear parameters such as critical boron concentrations, reactivity, control bank work, temperature coefficients, and pin and assembly power peaking factors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Validation of the SCALE/Polaris–PARCS Code Procedure With the ENDF/B-VII.1 AMPX 56-Group Library: Boiling Water Reactor

The SCALE/Polaris–PARCS code procedure has been used in the confirmatory analysis for boiling water reactors by the US Nuclear Regulatory Commission. In this study, the SCALE/Polaris v6.3.0–PARCS v3.4.2 code procedure with the Evaluated Nuclear Data File (ENDF)/B-VII.1 AMPX 56-group library was validated by comparing the simulated results with the measured data for operating boiling water reactors, including Peach Bottom Unit 2 cycles 1–3, Hatch Unit 1 cycles 1–3, and Quad Cities Unit 1 cycles 1–3. The uncertainties and biases of the SCALE/Polaris–PARCS code package for boiling water reactor physics analysis were evaluated in the validation for key nuclear parameters such as reactivity and traversing in-core probe data.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cumulative $\chi^2$ Metric for VALID for ENDF/B-VII.1 and ENDF/B-VIII.0 in SCALE 6.3b9

Nuclear data testing is generally performed in a manner similar to validation: a series of critical benchmark experiments is modeled, and the differences between calculated and expected results are examined to understand the performance of a code and cross section set. This process is repeated for multiple sets of experiments with different transport codes and sometimes with different datasets. Occasionally, data processing differences are also important in understanding the differences in calculated results. Relevant experts then meet periodically to compare results and set priorities for improvement in the next round of data updates. This process has been largely effective, despite the confounding factors of different benchmark sets, application areas, sponsors, nationalities, and the resulting different priorities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Continuous-Energy ENDF/B-VIII.0 Cross Section and SCALE 6.2.4 Performance for Nuclear Criticality Safety Applications: 1 H, C, 58,60 Ni, 182,183,184,186 W, 235,238 U, 239 Pu

As part of the nuclear data evaluation and validation cycle, the ENDF/B-VIII.0 cross-section library released in 2018 requires testing to determine areas of improvement and deterioration. Previous work by the authors investigated the performance of 16 O, 56 Fe, and 63,65 Cu cross sections, with this study acting as an extension of the prior work. In addition to the isotopes and nuclear criticality safety benchmarks of interest to the prior work, benchmarks from the International Criticality Safety Benchmark Evaluation Project Handbook were selected for their k eff sensitivity to 1 H, C, 58,60 Ni, 182,183,184,186 W, 235,238U, or 239 Pu cross sections and were modeled in the SCALE code system maintained by Oak Ridge National Laboratory. In total, 253 benchmark configurations were selected for their sensitivities and modeled using SCALE 6.2.4 Criticality Safety Analysis Sequences (CSAS) continuous-energy Monte Carlo k eff calculations. This collection includes and expands upon the 99 benchmarks in the prior work. The AMPX-processed ENDF/B-VIII.0 library was decomposed into individual ENDF/B-VIII.0 datum libraries for each isotope of interest. Doing so allowed for the individual substitution of an ENDF/B-VIII.0 cross section in the place of ENDF/B-VII.1, determining isotope-specific effects of ENDF/B-VIII.0 relative to ENDF/B-VII.1. Full library calculations with entirely ENDF/B-VII.1 data or entirely ENDF/B-VIII.0 data were also executed. As a measure of performance, the average relative deviation was determined as the ratio of the deviation between calculated and experimental keff to the propagated calculational and experimental uncertainty. With calculated full library and isotope-specific ENDF/B-VIII.0 k eff ’s, an optimized combination of data libraries was estimated and confirmed with SCALE calculations. This showed that reverting 239 Pu, 58 Ni, 16 O, and 65 Cu cross sections to ENDF/B-VII.1 resulted in improved performance relative to the full ENDF/B-VIII.0 library. Across all 253 benchmarks, the average relative deviation was 1.29σ for the full ENDF/B-VII.1 library, 1.17σ for the full ENDF/B-VIII.0 library, and 0.97σ for the optimized combination. The reversion of 239 Pu, 58 Ni, 16 O, and 65 Cu cross sections to ENDF/B-VII.1 in the 99 benchmarks of the prior work resulted in further improved experimental agreement compared to the previously reported improvement from 16 O and 65 Cu alone. Therefore, it is suggested that applications with significant sensitivities to 239 Pu, 58 Ni, 16 O, and 65 Cu consider their choice of nuclear data library.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Recent Testing of ENDF/B-VIII.0 at ORNL [Slides]

This presentation provides an overview of comparisons of ENDF/B-VII.1 and ENDF/B-VIII.0 and uses VALID suite to test >600 cases with ENDF/B-VII.1 and ENDF/B-VIII.0 in KENO V.a/KENO-VI, although a limited number of cases have been tested with TSUNAMI. It provides a results summary of KENO V.a/KENO-VI with a pooled results summary. The presentation also discusses changes for LCT experiments, MCT experiments, MST experiments, and PST experiments. A few words about graphite are also provided and the presentation states that graphite performance investigated across ENDF/B-VII.0, ENDF/B-VII.1, and ENDF/B-VIII.0 for MSR and HTGR models. A brief summary of the results is presented to make sure the Validation Committee is aware of the work. Also presented is an Eigenvalue comparison with a graphite moderated system, and comparison between an HTR-10 pebble model ENDF/B-VII.1 vs. ENDF/B-VIII.0, which provides different graphite data. In conclusion, ORNL has recently completed a comparison of ENDF/B-VIII.0 and ENDF/B-VII.1 using the VALID library. Work is also being performed for advanced reactor applications. Other efforts on-going and they are also trying to investigate more intermediate spectrum cases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data and Cross Section Testing Using ENDF/B-VIII.0

With the release of the Evaluated Nuclear Data File (ENDF)/B-VIII.0 library, nuclear criticality safety practitioners and engineers have access to the latest cross section sets available for their analyses. However, these cross sections must be rigorously tested and validated to ensure that the nuclear data are responsive to the needs of the individuals responsible for developing, implementing, and maintaining computational tools for criticality safety applications. Thus, the ENDF/B-VIII.0 library is tested and validated with a large collection of experiments that were vetted by the International Criticality Safety Benchmark Evaluation Project and made available in the International Handbook of Evaluated Criticality Safety Benchmark Experiments. A selection of benchmark experiments for use within the criticality safety community were prepared and reviewed within the Verified, Archived Library of Inputs and Data (VALID), which is maintained by the Nuclear Energy and Fuel Cycle Division at Oak Ridge National Laboratory. The performance of the ENDF/B-VIII.0 library is assessed by using VALID models of benchmark experiments with the beta 12 version of SCALE 6.3 KENO V.a and KENO-VI Monte Carlo codes. The performance is compared with the results obtained from with the ENDF/B-VII.1 library. This report considers multigroup (MG) and continuous energy (CE) formats of the ENDF/B-VIII.0 and -VII.1 libraries. The benchmark experiments within VALID that validate the ENDF/B-VIII.0 library cover 15 broad system categories by using a range of fissile materials, uranium enrichments, plutonium isotopic vectors, and mixed uranium/plutonium systems. These forms are represented as metals, solutions, or various arrays of rods or plates that cover a variety of neutron energy spectra: thermal, fast, mixed, and intermediate. Over 600 cases were considered for use with the KENO V.a and KENO-VI codes with the ENDF/B-VIII.0 library. The results of the Monte Carlo comparison of ENDF/B-VIII.0 to ENDF/B-VII.1 with both KENO V.a and KENO-VI indicate that there is a less than 0.53% Δk difference between the bias of calculated k eff from the expected values. The CE ENDF/B-VIII.0 library results in smaller magnitude biases than the ENDF/B-VII.1 data for HEU-MET-FAST, HEU-SOL-THERM, IEU-MET-FAST, LEU-SOL-THERM, PU-SOL-THERM, and U233-MET-FAST systems, while the MG results yielded smaller magnitude biases for HEU-MET-FAST, HEU-SOL-THERM, IEU-MET-FAST, LEU-COMP-THERM, LEU-SOL THERM, MIX-COMP-FAST, and U233-MET-FAST systems. Most notable are the adjustments to the plutonium and 233 U cross section data, which has resulted in noticeably lower biases in the ENDF/B VIII.0 results for the mixed, plutonium, and 233 U systems. Results of the sensitivity data file comparison generated from TSUNAMI-3D for selected VALID cases for the ENDF/B-VIII.0 library indicate a very high level of agreement with correlation coefficients of the effect of nuclear data uncertainty on k eff (the c k integral parameter) all above 0.99. This indicates that cases with the ENDF/B-VIII.0 library would see very similar responses to any nuclear data errors or change as those with the ENDF/B-VII.1 library.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Validation of Continuous-Energy ENDF/B-VIII.0 16 O, 56 Fe, and 63,65 Cu Cross Sections for Nuclear Criticality Safety Applications

Recently completed cross-section evaluations sponsored in part by the Nuclear Criticality Safety Program were incorporated into the 2018 release of the ENDF/B-VIII.0 cross-section library. Evaluated isotopes of interest to the nuclear data and criticality safety community include 16 O, 56 Fe, and 63,65 Cu. For performance validation, benchmark models defined in the International Criticality Safety Benchmark Evaluation Project Handbook were selected based on energy-integrated k eff sensitivities to total cross sections of interest and compared with experimental values. Of the 102 benchmark configurations that were utilized, 63 are sensitive to 16 O, 32 sensitive to 63,65 Cu, and 25 sensitive to 56 Fe. Selected benchmarks were modeled in SCALE 6.2.3 Criticality Safety Analysis Sequence (CSAS) continuous-energy Monte Carlo k eff calculations with ENDF/B-VII.1, with a hybrid ENDF/B-VII.1 with ENDF/B-VIII.0 data substituted for individual isotopes of interest, and with ENDF/B-VIII.0. ENDF/B-VIII.0 showed improved agreement with experimental k eff for 56 Fe, 63 Cu, elemental copper, and full library substitution while producing lessened agreement for 16 O and 65 Cu. Furthermore, with full library and isotope-specific ENDF/B-VIII.0 performance, a best-case ENDF library was formed by excluding underperforming isotopes’ ENDF/B-VIII.0 data, reverting 16 O and 65 Cu cross sections to ENDF/B-VII.1. This resulted in the average relative deviation between calculated and experimental data improving from 1.45σ for the ENDF/B-VIII.0 library to 1.32σ for the best-case library, relative to benchmark uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multigroup Examination of Nickel-Reflected HEU System

Critical configurations of HEU-MET-FAST-003 (HMF-003) from the International Criticality Safety Benchmark Evaluation Project Handbook were modeled for addition into the Verified, Archived Library of Inputs and Data maintained at Oak Ridge National Laboratory. HMF-003 contains models of a highly enriched uranium sphere with a spherical metal reflector of natural uranium, tungsten carbide, or nickel. For these simple models, good agreement is expected between the k eff calculated with continuous-energy (CE) and multigroup (MG) transport. However, using the CSAS5 sequence of the SCALE 6.2.4 package, the 8 in. thick nickel reflector model resulted in a difference of around 1.2 % Δ k . Results presented a clear indication of poor performance for the SCALE 252-group based on ENDF/B-VII.1 cross section library for this model. The bias was investigated over a range of nickel thickness and then compared with other MG libraries available in SCALE 6.2.4. As the nickel thickness increases, the MG k eff deviates from the CE result, confirming a performance issue with the MG calculation. Additionally, the reactions were compared between the two libraries to help determine the cause of k eff bias. Finally, additional MG libraries within SCALE 6.3 and based on ENDF/B-VII.1 and ENDF/B-VIII were reviewed. The 302-group and 1597-group result in significant improvements compared with the 252-group library. Nickel cross sections were modified from ENDF/B-VII.1 to ENDF/B-VIII. For the ENDF/B-VIII library, the deviation between the CE libraries and MG libraries is less pronounced than for ENDF/VII.1, except for the 1597-group. This examination clearly indicates the importance of validating calculations with applicable benchmark experiments and caution when using MG libraries.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗