Search NASA⌕ Search

SEARCH · Search NASA

Results for “ENDF/B-VIII.0”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluation of Neutron Reactions on Iron Isotopes for CIELO and ENDF/B-VIII.0

A new suite of evaluations for {sup 54,56,57,58}Fe has been developed in the framework of the CIELO international collaboration. New resolved resonance ranges were evaluated for {sup 54}Fe and {sup 57}Fe, while modifications were applied to resonances in {sup 56}Fe. The low energy part of the {sup 56}Fe file is almost totally based on measurements. At higher energies in {sup 56}Fe and in the whole fast neutron range for minor isotopes the evaluation consists of model predictions carefully adjusted to available experimental data. We also make use of the high quality and well experimentally-constrained dosimetry evaluations from the IRDFF library. Special attention was dedicated to the elastic angular distributions, which were found to affect results of the integral benchmarking. The new set of iron evaluations was developed in concert with other CIELO evaluations and they were tested together in the integral experiments before being adopted for the ENDF/B-VIII.0 library.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Stochastically estimated covariance matrices for independent and cumulative fission yields in the ENDF/B-VIII.0 and JEFF-3.3 evaluations

A Monte-Carlo method for the generation of correlation and covariance matrices for independent and cumulative fission yields has been developed. The method uses a constrained Monte-Carlo resampling structure in order to vary evaluated fission yield libraries in a way that meets basic conservation principles. This results in the generation of correlation/covariance matrices with limited model bias and uncertainty; the matrices are primarily reflective of the evaluated fission yield uncertainties and correlations that arise from the evaluation process. This method has been applied to generate correlation and covariance matrices for all of the fissioning systems of the ENDF/B-VIII.0 and JEFF-3.3 evaluations, marking the first time such matrices have been generated for all of these systems. These covariance matrices have been published online for immediate public use. These correlation and covariance matrices can be used to improve uncertainty estimation in calculations of reactor antineutrino emission rates, decay heat problems, and nuclear forensics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Continuous-Energy ENDF/B-VIII.0 Cross Section and SCALE 6.2.4 Performance for Nuclear Criticality Safety Applications: 1 H, C, 58,60 Ni, 182,183,184,186 W, 235,238 U, 239 Pu

As part of the nuclear data evaluation and validation cycle, the ENDF/B-VIII.0 cross-section library released in 2018 requires testing to determine areas of improvement and deterioration. Previous work by the authors investigated the performance of 16 O, 56 Fe, and 63,65 Cu cross sections, with this study acting as an extension of the prior work. In addition to the isotopes and nuclear criticality safety benchmarks of interest to the prior work, benchmarks from the International Criticality Safety Benchmark Evaluation Project Handbook were selected for their k eff sensitivity to 1 H, C, 58,60 Ni, 182,183,184,186 W, 235,238U, or 239 Pu cross sections and were modeled in the SCALE code system maintained by Oak Ridge National Laboratory. In total, 253 benchmark configurations were selected for their sensitivities and modeled using SCALE 6.2.4 Criticality Safety Analysis Sequences (CSAS) continuous-energy Monte Carlo k eff calculations. This collection includes and expands upon the 99 benchmarks in the prior work. The AMPX-processed ENDF/B-VIII.0 library was decomposed into individual ENDF/B-VIII.0 datum libraries for each isotope of interest. Doing so allowed for the individual substitution of an ENDF/B-VIII.0 cross section in the place of ENDF/B-VII.1, determining isotope-specific effects of ENDF/B-VIII.0 relative to ENDF/B-VII.1. Full library calculations with entirely ENDF/B-VII.1 data or entirely ENDF/B-VIII.0 data were also executed. As a measure of performance, the average relative deviation was determined as the ratio of the deviation between calculated and experimental keff to the propagated calculational and experimental uncertainty. With calculated full library and isotope-specific ENDF/B-VIII.0 k eff ’s, an optimized combination of data libraries was estimated and confirmed with SCALE calculations. This showed that reverting 239 Pu, 58 Ni, 16 O, and 65 Cu cross sections to ENDF/B-VII.1 resulted in improved performance relative to the full ENDF/B-VIII.0 library. Across all 253 benchmarks, the average relative deviation was 1.29σ for the full ENDF/B-VII.1 library, 1.17σ for the full ENDF/B-VIII.0 library, and 0.97σ for the optimized combination. The reversion of 239 Pu, 58 Ni, 16 O, and 65 Cu cross sections to ENDF/B-VII.1 in the 99 benchmarks of the prior work resulted in further improved experimental agreement compared to the previously reported improvement from 16 O and 65 Cu alone. Therefore, it is suggested that applications with significant sensitivities to 239 Pu, 58 Ni, 16 O, and 65 Cu consider their choice of nuclear data library.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Nuclear Data and Cross Section Testing Using ENDF/B-VIII.0

With the release of the Evaluated Nuclear Data File (ENDF)/B-VIII.0 library, nuclear criticality safety practitioners and engineers have access to the latest cross section sets available for their analyses. However, these cross sections must be rigorously tested and validated to ensure that the nuclear data are responsive to the needs of the individuals responsible for developing, implementing, and maintaining computational tools for criticality safety applications. Thus, the ENDF/B-VIII.0 library is tested and validated with a large collection of experiments that were vetted by the International Criticality Safety Benchmark Evaluation Project and made available in the International Handbook of Evaluated Criticality Safety Benchmark Experiments. A selection of benchmark experiments for use within the criticality safety community were prepared and reviewed within the Verified, Archived Library of Inputs and Data (VALID), which is maintained by the Nuclear Energy and Fuel Cycle Division at Oak Ridge National Laboratory. The performance of the ENDF/B-VIII.0 library is assessed by using VALID models of benchmark experiments with the beta 12 version of SCALE 6.3 KENO V.a and KENO-VI Monte Carlo codes. The performance is compared with the results obtained from with the ENDF/B-VII.1 library. This report considers multigroup (MG) and continuous energy (CE) formats of the ENDF/B-VIII.0 and -VII.1 libraries. The benchmark experiments within VALID that validate the ENDF/B-VIII.0 library cover 15 broad system categories by using a range of fissile materials, uranium enrichments, plutonium isotopic vectors, and mixed uranium/plutonium systems. These forms are represented as metals, solutions, or various arrays of rods or plates that cover a variety of neutron energy spectra: thermal, fast, mixed, and intermediate. Over 600 cases were considered for use with the KENO V.a and KENO-VI codes with the ENDF/B-VIII.0 library. The results of the Monte Carlo comparison of ENDF/B-VIII.0 to ENDF/B-VII.1 with both KENO V.a and KENO-VI indicate that there is a less than 0.53% Δk difference between the bias of calculated k eff from the expected values. The CE ENDF/B-VIII.0 library results in smaller magnitude biases than the ENDF/B-VII.1 data for HEU-MET-FAST, HEU-SOL-THERM, IEU-MET-FAST, LEU-SOL-THERM, PU-SOL-THERM, and U233-MET-FAST systems, while the MG results yielded smaller magnitude biases for HEU-MET-FAST, HEU-SOL-THERM, IEU-MET-FAST, LEU-COMP-THERM, LEU-SOL THERM, MIX-COMP-FAST, and U233-MET-FAST systems. Most notable are the adjustments to the plutonium and 233 U cross section data, which has resulted in noticeably lower biases in the ENDF/B VIII.0 results for the mixed, plutonium, and 233 U systems. Results of the sensitivity data file comparison generated from TSUNAMI-3D for selected VALID cases for the ENDF/B-VIII.0 library indicate a very high level of agreement with correlation coefficients of the effect of nuclear data uncertainty on k eff (the c k integral parameter) all above 0.99. This indicates that cases with the ENDF/B-VIII.0 library would see very similar responses to any nuclear data errors or change as those with the ENDF/B-VII.1 library.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Validation of Continuous-Energy ENDF/B-VIII.0 16 O, 56 Fe, and 63,65 Cu Cross Sections for Nuclear Criticality Safety Applications

Recently completed cross-section evaluations sponsored in part by the Nuclear Criticality Safety Program were incorporated into the 2018 release of the ENDF/B-VIII.0 cross-section library. Evaluated isotopes of interest to the nuclear data and criticality safety community include 16 O, 56 Fe, and 63,65 Cu. For performance validation, benchmark models defined in the International Criticality Safety Benchmark Evaluation Project Handbook were selected based on energy-integrated k eff sensitivities to total cross sections of interest and compared with experimental values. Of the 102 benchmark configurations that were utilized, 63 are sensitive to 16 O, 32 sensitive to 63,65 Cu, and 25 sensitive to 56 Fe. Selected benchmarks were modeled in SCALE 6.2.3 Criticality Safety Analysis Sequence (CSAS) continuous-energy Monte Carlo k eff calculations with ENDF/B-VII.1, with a hybrid ENDF/B-VII.1 with ENDF/B-VIII.0 data substituted for individual isotopes of interest, and with ENDF/B-VIII.0. ENDF/B-VIII.0 showed improved agreement with experimental k eff for 56 Fe, 63 Cu, elemental copper, and full library substitution while producing lessened agreement for 16 O and 65 Cu. Furthermore, with full library and isotope-specific ENDF/B-VIII.0 performance, a best-case ENDF library was formed by excluding underperforming isotopes’ ENDF/B-VIII.0 data, reverting 16 O and 65 Cu cross sections to ENDF/B-VII.1. This resulted in the average relative deviation between calculated and experimental data improving from 1.45σ for the ENDF/B-VIII.0 library to 1.32σ for the best-case library, relative to benchmark uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Guide for Using ENDF/B-VIII.0 Nuclear Data with MCNP

This report provides guidance for using the ENDF/B-VIII.0 nuclear data that were released in 2018 and 2020 with MCNP. Appendix A: Obtaining and installing the new ENDF/B-VIII.0 ACE nuclear data. Appendix B. Obtaining & using XSDIR files that include ENDF/B-VIII.0 data. Appendix C: ENDF/B-VIII.0-based ACE files for neutron cross-sections. A listing of the available temperatures and ZA numbers for neutron cross-sections (ACE files with suffix .nnC). Appendix D: ENDF/B-VIII.0-based ACE files for thermal scattering law (TSL) data, $S$(α,β). A listing of the available thermal scattering $S$(α,β) data (ACE files with suffix .nnT) The next section below provides guidance for modifying existing $\textit{mcnp}$ input files to use the ENDF/B-VIII.0 data. Detailed results from running several benchmark suites for nuclear criticality safety with both ENDF/B-VII.1 and ENDF/B-VIII.0 nuclear data are reported in. It is important to note that this report deals only with TSL data released in 2020. With the original release of ENDF/B-VIII.0 in 2018, the ACE files for neutron cross-sections were contained in a directory called Lib80X and the ACE files for TSL data were contained in a directory called ENDF80SaB. A few years later, it was determined that many of the TSL data files had been generated with faulty data or with incorrect processing, and a new set of ACE files for TSL data was created, with the corrected files contained in directory ENDF80SaB2.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ENDF/B-VIII.0 Covariance Data Development and Testing for Advanced Reactors

This report documents the ENDF/B-VIII.0 covariance data development and testing performed at Oak Ridge National Laboratory performed under the auspices of the US Department of Energy Office of Nuclear Energy. This work supports modeling and simulation of advanced reactor designs in the US by analyzing, validating and improving the nuclear data that provide underlying physics for calculations. This report assesses nuclear data uncertainty information for neutron cross sections, provided in the form of covariance matrices, in the 2018 ENDF/B-VIII.0 library. A review and interpretation of some of the issues with the current covariance library is provided. A new approach to augment the ENDF/B-VIII.0 covariance matrix to accurately reflect uncertainties in the results of modeling and simulation reliant on the current nuclear data library is documented. Rigorous testing of the ENDF/B-VIII.0 covariance data is documented. Finally, the performance of the ENDF/B-VIII.0 covariance data for advanced reactor applications is assessed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Recent Testing of ENDF/B-VIII.0 at ORNL [Slides]

This presentation provides an overview of comparisons of ENDF/B-VII.1 and ENDF/B-VIII.0 and uses VALID suite to test >600 cases with ENDF/B-VII.1 and ENDF/B-VIII.0 in KENO V.a/KENO-VI, although a limited number of cases have been tested with TSUNAMI. It provides a results summary of KENO V.a/KENO-VI with a pooled results summary. The presentation also discusses changes for LCT experiments, MCT experiments, MST experiments, and PST experiments. A few words about graphite are also provided and the presentation states that graphite performance investigated across ENDF/B-VII.0, ENDF/B-VII.1, and ENDF/B-VIII.0 for MSR and HTGR models. A brief summary of the results is presented to make sure the Validation Committee is aware of the work. Also presented is an Eigenvalue comparison with a graphite moderated system, and comparison between an HTR-10 pebble model ENDF/B-VII.1 vs. ENDF/B-VIII.0, which provides different graphite data. In conclusion, ORNL has recently completed a comparison of ENDF/B-VIII.0 and ENDF/B-VII.1 using the VALID library. Work is also being performed for advanced reactor applications. Other efforts on-going and they are also trying to investigate more intermediate spectrum cases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Benchmarking of ENDF/B-VIII.0 cross sections for LWR ex-core transport applications

ENDF/B-VIII.0 cross section data is benchmarked on a simple Monte-Carlo model representative of the ex-core geometry of a PWR used for reactor vessel neutron fluence calculations. The benchmarking indicates that the ENDF/B-VIII.0 results show large differences as compared to previous evaluations, which have been extensively compared to measured data. This exercise suggests that ENDF/B-VIII.0 nuclear data is not suitable for ex-core LWR radiation transport applications. Evaluators are aware of the problems with the ENDF/B-VIII.0 evaluation of iron and work is underway to improve the evaluations for an upcoming release.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Proposed Updates to Pu Evaluation for ENDF/B-VIII.0β 2 [Slides]

This presentation shows current status of in ENDF/B-VIII.0 and ENDF/B-VIII.0β 1 Pu evaluations. With a focus on the Pu thermal solutions (PST) and sanity check on fast metal assemblies (PMF). Pu ENDFβ 1 file in the low-energy region included updates in RRR (up to 2.5 keV), TNC and PFNS. Discussed are improvements over ENDF/B-VIII.0 in the C/E benchmarks (PST 81 cases) with preliminary ν p and cross section covariance generation for the resolved resonance energy range up to 2.25 keV. Highlighted are proposed updates for ENDFβ 2 with an extension of the RRR evaluation up to 5 keV, inclusion of Mosby’s data including proper resolution function (thanks to Marian J.), and a particular focus on η energy dependence from thermal up to 10 eV with the impact of the capture-to-fission ratio at 0.29 eV. This presentation concludes with an updated ν p and cross section covariance generation for the resolved resonance energy range up to 5 keV. And additional validation to test performance at about 2 eV and in the keV region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verification of MCNP6.2 with ENDF/B-VIII.0 Nuclear Data for Nuclear Criticality Safety Applications

MCNP6.2 was released in 2018 and is the latest production release of MCNP ® available from RSICC. MCNP6.2 includes all of the standard features for nuclear criticality safety (NCS) calculations that have been available for the past 15 years, along with new features for sensitivity-uncertainty based methods using Whisper for NCS validation. MCNP6.2 verification using ENDF/B-VII.1 nuclear data was previously reported in. This report focuses on the initial testing and verification of MCNP6.2 using the ENDF/B-VIII.0 nuclear data that were released in 2018. The sections that follow provide guidance for NCS users on modifying existing MCNP input files to use the new ENDF/B-VIII.0 ACE nuclear data, discussion of results for several ICSBEP-based benchmark suites using MCNP6.2 with ENDF/B-VII.1 and ENDF/B-VIII.0 nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ENDF/B-VIII.0: the 8. major release of the ENDF/B library containing CIELO-project evaluations, new standards and thermal scattering data - 25580

The ENDF/B-VIII.0 evaluated nuclear reaction data library was released on February 2, 2018. ENDF/B-VIII.0 incorporates many improvements including the new IAEA standards, a nearly completely new thermal neutron scattering sublibrary and the CIELO project evaluations for neutron reactions on {sup 16}O, {sup 56}Fe, {sup 235}U, {sup 238}U and {sup 239}Pu. These evaluations are a direct result of improvements in theory and simulation and benefit from recent experimental data obtained in the U.S. and Europe. Notable other advances include updated evaluated data for light nuclei, structural materials, actinides and charged-particle reactions, and specific updates to fission energy release, prompt fission neutron and γ-ray spectra. ENDF/B-VIII.0 has undergone substantial testing including a wide range of criticality, reaction rate, and shielding benchmarks. Our integral validation demonstrates that performance of the library is a noticeable improvement over the previous ENDF/B-VII.1 library. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

ENDF/B-VIII.0: The 8 th Major Release of the Nuclear Reaction Data Library with CIELO-project Cross Sections, New Standards and Thermal Scattering Data

We describe the new ENDF/B-VIII.0 evaluated nuclear reaction data library. ENDF/B-VIII.0 fully incorporates the new IAEA standards, includes improved thermal neutron scattering data and uses new evaluated data from the CIELO project for neutron reactions on 1 H, 16 O, 56 Fe, 235 U, 238 U and 239 Pu described in companion papers in the present issue of Nuclear Data Sheets. The evaluations benefit from recent experimental data obtained in the U.S. and Europe, and improvements in theory and simulation. Notable advances include updated evaluated data for light nuclei, structural materials, actinides, fission energy release, prompt fission neutron and γ-ray spectra, thermal neutron scattering data, and charged-particle reactions. Integral validation testing is shown for a wide range of criticality, reaction rate, and neutron transmission benchmarks. In general, integral validation performance of the library is improved relative to the previous ENDF/B-VII.1 library.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The ENDF/B-VIII.0 Compendium Volume I: Neutron Cross Section Plots

Version 8 of the Evaluated Nuclear Data File (ENDF/B-VIII.0) contains a wealth of nuclear data representing the most recent collection of evaluated neutron cross section measurements, isotopic radioactive decay, and much more. This Compendium has been prepared as a easily-navigable reference of the contents of the ENDF/B-VIII.0 library, while making no statement regarding the accuracy of those contents. The Compendium is split into four volumes.

07 ISOTOPE AND RADIATION SOURCES↗

The ENDF/B-VIII.0 Compendium Volume IV: Radioactive Decay Rank-Order Analyses

Version 8 of the Evaluated Nuclear Data File (ENDF/B-VIII.0) contains a wealth of nuclear data representing the most recent collection of evaluated neutron cross section measurements, isotopic radioactive decay, and much more. This Compendium has been prepared as a easily-navigable reference of the contents of the ENDF/B-VIII.0 library, while making no statement regarding the accuracy of those contents. The Compendium is split into four volumes. In Volume IV, radioactive decay properties are presented in tabular form, sorted by isotope, energy, element-then- energy, and probability of emission.

07 ISOTOPE AND RADIATION SOURCES↗

The ENDF/B-VIII.0 Compendium Volume II: Neutron Cross Section Rank-Order Analyses

Version 8 of the Evaluated Nuclear Data File (ENDF/B-VIII.0) contains a wealth of nuclear data representing the most recent collection of evaluated neutron cross section measurements, isotopic radioactive decay, and much more. This Compendium has been prepared as a easily-navigable reference of the contents of the ENDF/B-VIII.0 library, while making no statement regarding the accuracy of those contents. The Compendium is split into four volumes. Volume II presents a series of tables of reaction cross section values for thermal (0.025 eV), fission (1 MeV), and fusion (14 MeV) energies, each sorted by cross section value, isotope, and element-then-isotope to facilitate quick searches.

07 ISOTOPE AND RADIATION SOURCES↗

Determination of Solar System R-Process Abundances using ENDF/B-VIII.0 and TENDL-2015 libraries

Recent multi-messenger detection of the binary neutron star merger (GW170817) energized the astrophysical community and encouraged further research for determination of nuclear physics observables. Comprehensive studies of atomic nuclei in the cosmos provide an opportunity for investigating these astrophysical phenomena and acquiring complementary information on stellar nucleosynthesis processes that can be verified using the latest nuclear data. Evaluated Nuclear Data File (ENDF) libraries contain complete collections of reaction cross sections over the energy range relevant to astrophysics, fission yields and decay data. These data collections have been used worldwide in nuclear science, industry and national security applications. There is great interest in exploring the ENDF/B-VIII.0 and TALYS Evaluated Nuclear Data Library (TENDL-2015) for nuclear astrophysics purposes and comparing findings with the Karlsruhe Astrophysical Database of Nucleosynthesis in Stars (KADoNiS). The Maxwellian-averaged cross sections (MACS) and astrophysical reaction rates have been calculated using the ENDF/B-VIII.0 and TENDL-2015 evaluated data sets. The calculated cross sections were combined with the solar system abundances and fitted using the classical model of stellar nucleosynthesis. Astrophysical rapid- and slow-neutron capture, r- and s-process, respectively, abundances were obtained from present data and compared with available values. Further analysis of MACS reveals potential evaluated libraries data deficiencies and a strong need for new measurements. The current results demonstrate a large nuclear astrophysics potential of evaluated libraries and mutually beneficial relations between nuclear industry and research e orts.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Criticality and Radiation Shielding Impacts of ENDF/B-VIII.0 [Slides]

Several impacts of ENDF/B-VIII.0 on Radiation Shielding Applications were observed by researchers. Most reaction rates, attenuation ratios, and dose rates are similar for ENDF/B-VII.1 and ENDF/B-VIII.0. A significant reduction in reactor dosimetry results was noted. Investigation continues to reveal underlying data for discrepancies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗