Evaluation of Sandia NCS Benchmark Suite Updates
The Sandia Nuclear Criticality Safety (NCS) program’s benchmark suite was recently updated. This suite is used to ensure that NCS calculations using computer-based neutron transportation codes have an established baseline comparison of calculated versus known experimental results. The Evaluated Nuclear Data File (ENDF) version used for the MCNP models in the suite was changed from ENDF/B-VII.1 to ENDF/B-VIII.0. Additionally, relevant thermal scattering law data libraries (TSLs) were updated. The sensitivity of the calculational bias of each benchmark model to these changes is discussed. Implementation of the ENDF/B-VIII.0 library and updated TSLs results in improvements to bias distribution in the intermediate enriched uranium, plutonium, and mixed uranium–plutonium (IEU, PU, and MIX) fissionable material benchmark categories, but a small bias increase in low- and high-enriched uranium categories (LEU and HEU, respectively). The results also highlight the sensitivity of the benchmarks, with average lethargy of neutrons causing fission energies (EALF) in the intermediate energy range to ENDF/B library changes. The most numerous bias changes were observed in the thermal energy region when transitioning from ENDF/B-VII.1 to ENDF/B-VIII.0. In conclusion, most of the unique bias changes observed in MCNP 6.3.0 between the two nuclear data libraries were in the LEU-COMP-THERM evaluation subset.