Probing D-region globally using lightning waveforms detected by ENTLN [Slides]

This report includes research and data that the author's state demonstrates "the technique from [Shao et al., Nature Geoscience, 2012] can be used with ENTLN waveforms. Furthermore, an "automated processing has been developed to produce averaged waveforms and associated measurements." Ideas for future work is also presented.

54 ENVIRONMENTAL SCIENCES↗

Terrestrial Gamma‐Ray Flash Following Intense Negative Return Stroke Observed With BIMAP‐3D

We report ground-based observations of a terrestrial gamma-ray flash (TGF) associated with a strong negative cloud-to-ground lightning strike (-CG) which occurred near Los Alamos National Laboratory (LANL) in New Mexico, USA. Gamma photons were detected by the Terrestrial High-energy Observations of Radiation (THOR) instrument, developed at the University of California, Santa Cruz, which has been hosted at LANL since 2022. Simultaneous measurements were also made with the 3-Dimensional Broadband Interferometric Mapping and Polarization (BIMAP-3D) system, which includes 3D lightning mapping, two fast antennas, and an additional plastic scintillator. Additional field change waveforms were obtained from the Earth Networks Total Lightning Network (ENTLN). The lightning initiated about 1 km above the ground, leading to a powerful -CG with an ENTLN peak current of −237 kA and bipolar field change matching the recently described “energetic compact stroke” (ECS) shape. The TGF was then observed ∼35 µs after the start of the return stroke. We also observe an electric field pulse likely produced by the TGF either in isolation or by coupling to the lightning channel. Based on modeling of the radiated electric field and photon propagation through the atmosphere we infer that the TGF source was on the order of 1⁢0 17 photons. This TGF and associated lightning are extremely similar to some recently reported ECS TGFs in coastal Japan in winter, but we report the first observation of this phenomenon outside of Japan in a different climate, terrain, and season.

58 GEOSCIENCES↗

Probing the D-region ionosphere globally with Earth Networks Total Lightning Network data

An existing technique to use broadband lightning waveforms to probe the D-region ionosphere (60–90 km altitude) is shown to be extendable to a global scale using the Earth Networks Total Lightning Network (ENTLN). This paper demonstrates the technique in detail on a region of the Southeastern United States. This demonstration shows that diurnal D-region height variation and smaller time-scale variations on the order of tens of minutes to hours are evident in the measurement. The technique is then extended to three additional global regions on this same day: Northeastern U.S., India, and Japan. The diurnal behavior between these different regions is compared to a D-region model from the International Reference Ionosphere.

D-region ionosphere↗

Machine-learning-based investigation of the variables affecting summertime lightning occurrence over the Southern Great Plains

Lightning is affected by many factors, many of which are not routinely measured, well understood, or accounted for in physical models. Several commonly used machine learning (ML) models have been applied to analyze the relationship between Atmospheric Radiation Measurement (ARM) data and lightning data from the Earth Networks Total Lightning Network (ENTLN) in order to identify important variables affecting lightning occurrence in the vicinity of the Southern Great Plains (SGP) ARM site during the summer months (June, July, August and September) of 2012 to 2020. Testing various ML models, we found that the random forest model is the best predictor among common classifiers. When convective clouds were detected, it predicts lightning occurrence with an accuracy of 76.9 % and an area under the curve (AUC) of 0.850. Using this model, we further ranked the variables in terms of their effectiveness in nowcasting lightning and identified geometric cloud thickness, rain rate and convective available potential energy (CAPE) as the most effective predictors. The contrast in meteorological variables between no-lightning and frequent-lightning periods was examined for hours with CAPE values conducive to thunderstorm formation. Besides the variables considered for the ML models, surface variables and mid-altitude variables (e.g., equivalent potential temperature and minimum equivalent potential temperature, respectively) have statistically significant contrasts between no-lightning and frequent-lightning hours. For example, the minimum equivalent potential temperature from 700 to 500 hPa is significantly lower during frequent-lightning hours compared with no-lightning hours. Finally, a notable positive relationship between the intracloud (IC) flash fraction and the square root of CAPE ($\sqrt{CAPE}$) was found, suggesting that stronger updrafts increase the height of the electrification zone, resulting in fewer flashes reaching the surface and consequently a greater IC flash fraction.

54 ENVIRONMENTAL SCIENCES↗