Search NASA⌕ Search

SEARCH · Search NASA

Results for “EQUIPMENT PROTECTION DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Remote switch actuator

The invention provides a device and method for actuating electrical switches remotely. The device is removably attached to the switch and is actuated through the transfer of a user's force. The user is able to remain physically removed from the switch site obviating need for protective equipment. The device and method allow rapid, safe actuation of high-voltage or high-current carrying electrical switches or circuit breakers.

42 ENGINEERING↗

Open-Source High-Fidelity Aggregate Composite Load Models of Emerging Load Behaviors for Large-Sale Analysis

The goal of this project is to accurately model the dynamic loads for power system planning and operation and to address the challenges inherent in such modeling. Existing load models are inadequate to handle the increasing proliferation of residential air conditioner loads and distributed energy resources, the emerging trends of price-responsive demand, and the growing importance of protective devices in equipment and buildings. A need has emerged to develop a fundamentally new class of load models and next-generation data tools. This work proposes to develop a set of regional–level, scalable open source load models and tools, including large-scale aggregate load protection, concept of price responsive demand, advanced load composition data, next-generation load model data tools, and advanced composite load model calibration and validation frameworks to address new challenges in the representation of next-generation load models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synthetic Sling Failure - Evaluations and Recommendations

The information and evaluations provided in this report were compiled to address the recurring problem of synthetic sling failure. As safety is the number one priority in all work aspects, a solution must be devised to prevent accidents from occurring. A total of thirteen cases regarding synthetic sling failure were evaluated in order to determine their causes, effects, and preventative measures. From the collected data, it was found that all cases in which the synthetic sling contacted the edge of its load resulted in sling failure. It is required that adequate synthetic sling protection devices be used to protect slings in any lift where the sling comes in direct contact with the edge or corner of its load. However, there are no consensus codes or standards stating the type, material, or purpose of the type of protective device used to protect the sling from being cut. Numerous industry standards and codes provide vague descriptions on how to protect synthetic slings. Without a clear, concise statement of how to protect synthetic slings, it is common for inadequate materials and sling protection devices to be used in an attempt to meet the intent of these requirements. The use of an inadequate sling protection device is the main cause of synthetic sling failure in all researched cases. Commercial sling protection devices come in many shapes and sizes, and have a variety of names, as well as advertised uses. 'Abrasion pads' and 'wear protectors' are two different names for products with the same intended purpose. There is no distinguishable way to determine the extent of sling protection which these devices will provide, or what specific scenarios they are made for. This creates room for error in a field where error is unacceptable. This report provides a recommended action for hoisting and rigging activities which require synthetic slings to contact a load, as well as recommended changes to industry standards which will benefit overall industry safety.

42 ENGINEERING↗

Compressed Natural Gas Vehicle Maintenance Facility Modification Handbook

To ensure the safety of personnel and facilities, vehicle maintenance facilities are required by law and by guidelines of the National Fire Protection Association (NFPA) and the International Fire Code (IFC) to exhibit certain design features. They are also required to be fitted with certain fire protection equipment and devices because of the potential for fire or explosion in the event of fuel leakage or spills. All fuels have an explosion or fire potential if specific conditions are present. This handbook covers the primary elements that must be considered when developing a CNG vehicle maintenance facility design that will protect against the ignition of natural gas releases. It also discusses specific protocols and training needed to ensure safety.

cng, maintenance facility, compressed natural gas,↗

Compressed Natural Gas Vehicle Maintenance Facility Modification Handbook

To ensure the safety of personnel and facilities, vehicle maintenance facilities are required by law and by guidelines of the National Fire Protection Association (NFPA) and the International Fire Code (IFC) to exhibit certain design features. They are also required to be fitted with certain fire protection equipment and devices because of the potential for fire or explosion in the event of fuel leakage or spills. All fuels have an explosion or fire potential if specific conditions are present. The hazard presented by liquid fuels, such as gasoline and diesel, results from the spillage of these liquids and subsequent ignition of vapors, causing a fire or explosion. Facilities that maintain liquid-fueled vehicles and implement appropriate safety measures are protected with ventilation systems designed to capture liquid fuel vapors at or near floor level. To minimize the potential for ignition in the event of a spill, receptacles, electrical fixtures, and hot-work operations, such as welding, are located outside of these areas. Compressed natural gas (CNG) is composed of methane with slight amounts of heavier simple hydrocarbons. Maintenance facilities that maintain CNG vehicles indoors must be protected against fire and explosion. However, the means of ensuring safety are different from those employed for liquid fuels because of the gaseous nature of methane and the fact that it is lighter than air. Because CNG is lighter than air, a release will rise to the ceiling of the maintenance facility and quickly dissipate rather than remaining at or near floor level like liquid fuel vapors. Although some of the means of protection for CNG vehicle maintenance facilities are similar to those used for liquid-fueled vehicles (ventilation and elimination of ignition sources), the types and placement of the protection equipment are different because of the behavior of the different fuels. The nature of gaseous methane may also require additional safeguards, such as combustible gas detectors and control systems, or specialized space heating, which are not needed in facilities servicing liquid-fuel vehicles. This handbook covers maintenance facilities that service CNG-fueled vehicles. Although similar requirements are mandated for liquefied natural gas (LNG) or liquefied petroleum gas (LPG) fueled vehicles, LNG and LPG are not covered in this handbook.

30 DIRECT ENERGY CONVERSION↗

High energy arcing fault fires in switchgear equipment : a literature review.

In power generating plants, switchgear provide a means to isolate and de-energize specific electrical components and buses in order to clear downstream faults, perform routine maintenance, and replace necessary electrical equipment. These protective devices may be categorized by the insulating medium, such as air or oil, and are typically specified by voltage classes, i.e. low, medium, and high voltage. Given their high energy content, catastrophic failure of switchgear by means of a high energy arcing fault (HEAF) may occur. An incident such as this may lead to an explosion and fire within the switchgear, directly impact adjacent components, and possibly render dependent electrical equipment inoperable. Historically, HEAF events have been poorly documented and discussed in little detail. Recent incidents involving switchgear components at nuclear power plants, however, were scrupulously investigated. The phenomena itself is only understood on a very elementary level from preliminary experiments and theories; though many have argued that these early experiments were inaccurate due to primitive instrumentation or poorly justified methodologies and thus require re-evaluation. Within the past two decades, however, there has been a resurgence of research that analyzes previous work and modern technology. Developing a greater understanding of the HEAF phenomena, in particular the affects on switchgear equipment and other associated switching components, would allow power generating industries to minimize and possibly prevent future occurrences, thereby reducing costs associated with repair and downtime. This report presents the findings of a literature review focused on arc fault studies for electrical switching equipment. The specific objective of this review was to assess the availability of the types of information needed to support development of improved treatment methods in fire Probabilistic Risk Assessment (PRA) for nuclear power plant applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Superconducting matrix fault current limiter with current-driven trigger mechanism

A modular and scalable Matrix-type Fault Current Limiter (MFCL) that functions as a "variable impedance" device in an electric power network, using components made of superconducting and non-superconducting electrically conductive materials. An inductor is connected in series with the trigger superconductor in the trigger matrix and physically surrounds the superconductor. The current surge during a fault will generate a trigger magnetic field in the series inductor to cause fast and uniform quenching of the trigger superconductor to significantly reduce burnout risk due to superconductor material non-uniformity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating HPC simulations and physical experiments to characterize the effects of gamma radiation on seismic protective devices

Seismic protective systems, composed of seismic isolators and dampers, can substantially reduce the effects of earthquake shaking on nuclear power plants and components therein. To enable the use of these devices to protect equipment inside a plant and close to a source of radiation, the U.S. Department of Energy (DOE) funded a project at the Idaho National Laboratory (INL) and the University at Buffalo to characterize the effects of absorbed gamma dose on their mechanical properties. An early task in the project was to determine the exposure time required in the INL Foss Therapy Services (FTS) 60 Co gamma irradiator to achieve a target absorbed dose in the materials used to construct isolators and dampers, including fluids, polymers, composites, and metals. This task required the novel integration of high-performance computing (HPC), Monte Carlo N-Particle (MCNP) simulations, and irradiation experiments using Fricke dosimetry. An MCNP model of the FTS irradiator at INL was developed and validated using Fricke dosimetry. Simulations of three experiments in the irradiator, two with Fricke vials only and one with Fricke vials and a large-size isolator, predicted the Fricke-measured absorbed dose rate to within 15% in all three cases, providing high confidence in the calculation of the gamma dose absorbed in the materials comprising the seismic protective devices. The simulations demonstrated that the effects of photon scattering on absorbed dose rate in the FTS irradiator are negligible for test articles installed close to the cobalt sources and near the rear of the irradiator. The validated MCNP model of the FTS irradiator is being used to support ongoing DOE-funded experiments on seismic protective devices and could be applied to future, non-seismic-related experiments. In conclusion, the novel validation process successfully deployed for the FTS irradiator at INL could be applied to other irradiators, requiring new MCNP models and simulations, and irradiation experiments using dosimeters.

42 - ENGINEERING↗

Benchmarking MCNP models to support gamma irradiation experiments

Seismic isolators and damping devices have been used for 30+ years to reduce seismic forces and deployed in 10,000+ structures, including bridges, buildings, and mission-critical infrastructure. Studies have shown that seismic isolation of nuclear power plants can reduce the seismic risk by several orders of magnitude and substantially reduce the overnight capital cost. Advanced reactor developers are considering seismic isolation as an integral design feature in their reactor design. It can either be deployed at the building level, isolating the entire reactor building, or at the component level, isolating individual pieces of safety-class equipment, such as a reactor vessel or a steam generator. For equipment isolation, located close to the reactor vessel, the seismic isolators and/or damping devices may be exposed to gamma and neutron radiation, with a possible effect on their mechanical properties which would affect the response of the isolated equipment under earthquake shaking. The Department of Energy, as part of its Nuclear Energy University Program (NEUP), in collaboration with the Idaho National Laboratory (INL), is funding a project at the University at Buffalo (UB) to investigate the effect of gamma radiation on the mechanical properties of various seismic protective devices. (When isolating equipment, the seismic protective devices will be located outside the reactor vessel where the neutron exposure will be insignificant.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Fused ring and linking groups effect on overcharge protection for lithium-ion batteries.

The derivatives of 1,3-benzodioxan (DBBD1) and 1,4-benzodioxan (DBBD2) bearing two tert-butyl groups have been synthesized as new redox shuttle additives for overcharge protection of lithium-ion batteries. Both compounds exhibit a reversible redox wave over 4 V vs Li/Li{sup +} with better solubility in a commercial electrolyte (1.2 M LiPF{sub 6}) dissolved in ethylene carbonate/ethyl methyl carbonate (EC/EMC 3/7) than the di-tert-butyl-substituted 1,4-dimethoxybenzene (DDB). The electrochemical stability of DBBD1 and DBBD2 was tested under charge/discharge cycles with 100% overcharge at each cycle in MCMB/LiFePO{sub 4} and Li{sub 4}Ti{sub 5}O{sub 12}/LiFePO{sub 4} cells. DBBD2 shows significantly better performance than DBBD1 for both cell chemistries. The structural difference and reaction energies for decomposition have been studied by density functional calculations.

25 ENERGY STORAGE↗

Sheath expansion and plasma dynamics in the presence of electrode evaporation: Application to a vacuum circuit breaker

During the postarc dielectric recovery phase in a vacuum circuit breaker, a cathode sheath forms and expels the plasma from the electrode gap. The success or failure of current breaking depends on how efficiently the plasma is expelled from the electrode gap. The sheath expansion in the postarc phase can be compared to sheath expansion in plasma immersion ion implantation except that collisions between charged particles and atoms generated by electrode evaporation may become important in a vacuum circuit breaker. In this paper, we show that electrode evaporation plays a significant role in the dynamics of the sheath expansion in this context not only because charged particle transport is no longer collisionless but also because the neutral flow due to evaporation and temperature gradients may push the plasma toward one of the electrodes. Using a hybrid model of the nonequilibrium postarc plasma and cathode sheath coupled with a direct simulation Monte Carlo method to describe collisions between heavy species, we present a parametric study of the sheath and plasma dynamics and of the time needed for the sheath to expel the plasma from the gap for different values of plasma density and electrode temperatures at the beginning of the postarc phase. This work constitutes a preliminary step toward understanding and quantifying the risk of current breaking failure of a vacuum arc.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Model Reduction for Fast Assessment of Grid Impact of High Penetration PV

A key challenge in properly analyzing the impact of solar photovoltaics (PV) during planning, interconnection and operation in the distribution grid is computational complexity. Such studies require the use of Quasi-Steady-Time-Series (QSTS) power flow to capture the complex interaction of PV with voltage regulating equipment and protection devices and a large number of scenario studies are needed to capture location specific constraints and uncertainties. In addition, a typical distribution feeder can have thousands of nodes and there can be thousands of such feeders in a given utility system. To solve this problem, a new and systematic method for distribution network reduction is proposed. The objective is to reduce the size of distribution systems by more than 80% while preserving the accuracy of power flow results. To this end, an extended Ward-equivalent method has been proposed to create an equivalent circuit. Moreover, load and PV aggregation based on the backward sweep method has been developed to further simplify the feeder. The proposed method is tested with a modified IEEE 123-node distribution test system. The simulation results demonstrate the high efficiency and accuracy of the proposed approach for distribution network reduction.

reduced order systems, load flow, load modeling, v↗

Lithium borate cluster salts as novel redox shuttles for overcharge protection of lithium-ion cells.

Redox shuttle is a promising mechanism for intrinsic overcharge protection in lithium-ion cells and batteries. Two lithium borate cluster salts are reported to function as both the main salt for a nonaqueous electrolyte and the redox shuttle for overcharge protection. Lithium borate cluster salts with a tunable redox potential are promising candidates for overcharge protection for most positive electrodes in state-of-the-art lithium-ion cells.

25 ENERGY STORAGE↗

MANGO – Modal Analysis for Grid Operation: A Method for Damping Improvement through Operating Point Adjustment

Small signal stability problems are one of the major threats to grid stability and reliability in the U.S. power grid. An undamped mode can cause large-amplitude oscillations and may result in system breakups and large-scale blackouts. There have been several incidents of system-wide oscillations. Of those incidents, the most notable is the August 10, 1996 western system breakup, a result of undamped system-wide oscillations. Significant efforts have been devoted to monitoring system oscillatory behaviors from measurements in the past 20 years. The deployment of phasor measurement units (PMU) provides high-precision, time-synchronized data needed for detecting oscillation modes. Measurement-based modal analysis, also known as ModeMeter, uses real-time phasor measurements to identify system oscillation modes and their damping. Low damping indicates potential system stability issues. Modal analysis has been demonstrated with phasor measurements to have the capability of estimating system modes from both oscillation signals and ambient data. With more and more phasor measurements available and ModeMeter techniques maturing, there is yet a need for methods to bring modal analysis from monitoring to actions. The methods should be able to associate low damping with grid operating conditions, so operators or automated operation schemes can respond when low damping is observed. The work presented in this report aims to develop such a method and establish a Modal Analysis for Grid Operation (MANGO) procedure to aid grid operation decision making to increase inter-area modal damping. The procedure can provide operation suggestions (such as increasing generation or decreasing load) for mitigating inter-area oscillations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quench propagation in the HOM damper of the 56 MHz cavity

The aim of this report is to summarize a study of the propagation of a quench in a HOM damper probe of the 56 MHz superconducting storage cavity for RHIC and provide guidance for machine protection. The 56 MHz cavity [1] is designed to operate as a beam-driven superconducting quarter-wave resonator in the RHIC ring. Four Higher Order Mode (HOM) dampers [2] are used to prevent beam instabilities [3] in RHIC. These are inserted in the back wall of the cavity (the high magnetic field region) through ports that also serve for rinsing the cavity with high-pressure deionized water as well as the fundamental power coupler and pick-up ports. Figure 1 shows the outline of the cavity [4,5]. The HOM damper probe has a magnetic coupling loop which penetrates the cavity as shown in Figure 2 [5]. The loop is cooled by conduction to the 4.3K helium system, thus any sudden, significant amount of heat dumped on the loop will cause local heating. The peak magnetic field on the loop can reach about 7.4 x 10{sup 4} amperes per meter at a cavity voltage of 2.5 MV [5]. The scenario we present here is that a small region on the loop quenches. We can calculate the current driving the cavity using the RHIC parameters and get the magnetic field as a function of the current, the cavity's intrinsic Q and detuning parameter, however it turns out that within the time relevant for the quench development (a fraction of a second) the cavity field does not change sufficiently to warrant this extra computation. Thus we can assume that the field over the loop is constant. The damper loop dimensions are not so important, however its cross section is. In the following we assume that the loop's cross-section is 2 cm by 0.3 cm. It is actually rounded in cross section (sharp corners avoided) but we will approximate it as square. The material parameters taken for the niobium loop (assuming high RRR of about 200) are given in the following stepwise linear approximations. The surface resistivity in ohms as a function of temperature in degrees Kelvin is given in Figure 3, the thermal conductivity in watt per degree meter as a function of temperature is given in Figure 4 and the heat capacity in Joule per kg as a function of temperature is given in Figure 5.

43 PARTICLE ACCELERATORS↗

Effects of a conducting sphere moving through a gradient magnetic field.

We examine several conducting spheres moving through a magnetic field gradient. An analytical approximation is derived and an experiment is conducted to verify the analytical solution. The experiment is simulated as well to produce a numerical result. Both the low and high magnetic Reynolds number regimes are studied. Deformation of the sphere is noted in the high Reynolds number case. It is suggested that this deformation effect could be useful for designing or enhancing present protection systems against space debris.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗