Search NASA⌕ Search

SEARCH · Search NASA

Results for “EQUIVALENT PLATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Calibration and equivalency analysis of image plate scanners

A universal procedure was developed to calibrate image plate scanners using radioisotope sources. Techniques to calibrate scanners and sources, as well as cross-calibrate scanner models, are described to convert image plate dosage into physical units. This allows for the direct comparison of quantitative data between any facility and scanner. An empirical relation was also derived to establish sensitivity response settings for arbitrary gain settings. In practice, these methods may be extended to any image plate scanning system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation on Mechanical Properties and Equivalent Model of Aluminum Honeycomb Sandwich Panels

In this study, positive-pressure, bending, and drum peel tests were carried out for aluminum honeycomb sandwich panels made of different materials and with different dimensions. The results of these tests not only precisely revealed the relationships between the mechanical properties of aluminum honeycomb sandwich panels and the material dimensions of the face and core layers, the layout mode of the core layer, and the connecting mode between the face layers and core layers, but also determined the reliable mechanical equivalent model. The test results indicate that when the specimen was subjected to the vertical load, the compression properties of aluminum honeycomb sandwich panels were mainly determined by its core layer, while the face layer mainly relieves the axial stress and restrains the deformation of the core layer. In the flexural test, the face layer is the main part subjected to the load, whereas the core layer shows supporting, stabilizing, and strengthening effects, slowing the deformation of the face layer; flexural-tensile properties can be somewhat affected by the layout type of the core layer. The equivalent plate model, honeycomb plate model, and sandwich panel model were screened based on the experimental results, indicating that the sandwich panel model provided a more accurate description. The sandwich panel model was further modified, ultimately resulting in a more effective equivalent model that can accurately reflect the mechanical properties of the aluminum honeycomb sandwich panels.

36 MATERIALS SCIENCE↗

Alpha spectroscopy backgrounds at Lawrence Livermore National Laboratory: technical equivalency for backgrounds with blank plates versus backgrounds with no plates

Alpha spectroscopy chamber backgrounds are routinely measured using blank plates. Operator time spent moving blank plates in and out of chambers is significant. If chamber backgrounds are measured in empty chambers, time spent moving blank plates can be reclaimed for other uses. This study compares here results of chamber backgrounds measured with and without plates. Five hundred fourteen chamber backgrounds measured with plates are paired with 514 chamber backgrounds measured without plates. The total counts within 13 spectral regions of interest are compared statistically. Chamber backgrounds measured without blank plates are found statistically equivalent to chamber backgrounds measured with blank plates.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

TH-AB-209-02: Gadolinium Measurements in Human Bone Using in Vivo K X-Ray Fluorescence (KXRF) Technique

Purpose: Improvement in an in vivo K x-ray fluorescence system, based on 109Cd source, for the detection of gadolinium (Gd) in bone has been investigated. Series of improvements to the method is described. Gd is of interest because of the extensive use of Gd-based contrast agents in MR imaging and the potential toxicity of Gd exposure. Methods: A set of seven bone equivalent phantoms with different amount of Gd concentrations (from 0–100 ppm) has been developed. Soft tissue equivalent plastic plates were used to simulate the soft tissue overlaying the tibia bone in an in vivo measurement. A new 5 GBq 109Cd source was used to improve the source activity in comparison to the previous study (0.17 GBq). An improved spectral fitting program was utilized for data analysis. Results: The previous published minimum detection limit (MDL) for Gd doped phantom measurements using KXRF system was 3.3 ppm. In this study the MDL for bare bone phantoms was found to be 0.8 ppm. Our previous study used only three layers of plastic (0.32, 0.64 and 0.96 mm) as soft tissue equivalent materials and obtained the MDL of 4–4.8 ppm. In this study the plastic plates with more realistic thicknesses to simulate the soft tissue covering tibia bone (nine thicknesses ranging from 0.61–6.13 mm) were used. The MDLs for phantoms were determined to be 1.8–3.5 ppm. Conclusion: With the improvements made to the technology (stronger source, improved data analysis algorithm, realistic soft tissue thicknesses), the MDL of the KXRF system to measure Gd in bare bone was improved by a factor of 4.1. The MDL is at the level of the bone Gd concentration reported in literature. Hence, the system is ready to be tested on human subjects to investigate the use of bone Gd as a biomarker for Gd toxicity.

60 APPLIED LIFE SCIENCES↗

Proton Radiography Imager:Generates Synthetic Proton Radiographs

ProRad is a computer program that is used to generate synthetic images of proton (or other charged particles) radiographs. The proton radiographs arc images that arc obtained by sending energetic protons (or electrons or positrons, for example) through 11 plasma where electric and/or magnetic fields alter the particles trajectory, Dnd the variations me imaged on RC film, image plate, or equivalent

Wilks, ScottC.↗

Advanced Distillation Final Report

The Advanced Distillation project was concluded on December 31, 2009. This U.S. Department of Energy (DOE) funded project was completed successfully and within budget during a timeline approved by DOE project managers, which included a one year extension to the initial ending date. The subject technology, Microchannel Process Technology (MPT) distillation, was expected to provide both capital and operating cost savings compared to conventional distillation technology. With efforts from Velocys and its project partners, MPT distillation was successfully demonstrated at a laboratory scale and its energy savings potential was calculated. While many objectives established at the beginning of the project were met, the project was only partially successful. At the conclusion, it appears that MPT distillation is not a good fit for the targeted separation of ethane and ethylene in large-scale ethylene production facilities, as greater advantages were seen for smaller scale distillations. Early in the project, work involved flowsheet analyses to discern the economic viability of ethane-ethylene MPT distillation and develop strategies for maximizing its impact on the economics of the process. This study confirmed that through modification to standard operating processes, MPT can enable net energy savings in excess of 20%. This advantage was used by ABB Lumus to determine the potential impact of MPT distillation on the ethane-ethylene market. The study indicated that a substantial market exists if the energy saving could be realized and if installed capital cost of MPT distillation was on par or less than conventional technology. Unfortunately, it was determined that the large number of MPT distillation units needed to perform ethane-ethylene separation for world-scale ethylene facilities, makes the targeted separation a poor fit for the technology in this application at the current state of manufacturing costs. Over the course of the project, distillation experiments were performed with the targeted mixture, ethane-ethylene, as well as with analogous low relative volatility systems: cyclohexane-hexane and cyclopentane-pentane. Devices and test stands were specifically designed for these efforts. Development progressed from experiments and models considering sections of a full scale device to the design, fabrication, and operation of a single-channel distillation unit with integrated heat transfer. Throughout the project, analytical and numerical models and Computational Fluid Dynamics (CFD) simulations were validated with experiments in the process of developing this platform technology. Experimental trials demonstrated steady and controllable distillation for a variety of process conditions. Values of Height-to-an-Equivalent Theoretical Plate (HETP) ranging from less than 0.5 inch to a few inches were experimentally proven, demonstrating a ten-fold performance enhancement relative to conventional distillation. This improvement, while substantial, is not sufficient for MPT distillation to displace very large scale distillation trains. Fortunately, parallel efforts in the area of business development have yielded other applications for MPT distillation, including smaller scale separations that benefit from the flowsheet flexibility offered by the technology. Talks with multiple potential partners are underway. Their outcome will also help determine the path ahead for MPT distillation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Proton Radiography Imager:Generates Synthetic Proton Radiographs

ProRad is a computer program that is used to generate synthetic images of proton (or other charged particles) radiographs. The proton radiographs arc images that arc obtained by sending energetic protons (or electrons or positrons, for example) through 11 plasma where electric and/or magnetic fields alter the particles trajectory, Dnd the variations me imaged on RC film, image plate, or equivalent

Wilks, Scott C.↗

Discrete Fracture Network Modeling to Estimate Upscaled Parameters for the Topopah Spring, Lava Flow, and Tiva Canyon Aquifers at Pahute Mesa, Nevada National Security Site

This report describes the results of Discrete Fracture Network (DFN) simulations for the Topopah Spring Aquifer (TSA), Lava Flow Aquifer, and Tiva Canyon Aquifer (TCA), at Pahute Mesa on the Nevada National Security Site (NNSS), formerly the Nevada Test Site. The research focuses on calculating upscaled groundwater flow and contaminant transport parameters using DFNs generated according to fracture characteristics observed in the TSA, LFA and TCA at Pahute Mesa. The highly fractured and heterogeneous nature of these aquifers makes them candidates for stochastic DFN modeling of radionuclide transport on a small scale with subsequent upscaling. One hundred independent DFN realizations are generated for each aquifer, and the upscaled parameters for continuum simulations of subsurface flow and transport in fractured media at Pahute Mesa are calculated. Our goal is to implement a modeling approach that can translate parameters to larger-scale models that account for local-scale flow and transport processes, such as channelization of flow and transport along a few well connected, large fractures. Additionally, to simulate advective and advective-diffusive transport through the fracture networks, the Time Domain Random Walk (TDRW) approach is applied to account for matrix diffusion into a finite half-space. Moreover, a novel approach to calculate dynamic (active) fracture surface area to reflect flow channeling is implemented. This work will improve the representation of radionuclide transport processes in largescale, regulatory-focused models by providing estimates of hard-to-measure flow and contaminant transport parameters at large scales. In this report, we (1) show recent results of flow and transport simulations on multiple DFN realizations of the TSA, LFA, TCA; (2) discuss the resulting distributions of estimated upscaled parameters; (3) describe the estimation of upscaled parameters for an equivalent parallel-plate continuum model and (4) present a comparison between simulated transport from the equivalent continuum model and an actual DFN.

54 ENVIRONMENTAL SCIENCES↗

Additively manufactured cryogenic microchannel distillation device for air separation

Abstract The efficiency of air separation is tested using three different small‐scale cryogenic distillation columns. The performance of a random packed column is compared to the performance of two microchannel distillation (MCD) columns that use thin wicking structures and gas flow channels to achieve process intensification. The MCD columns tested include a plate‐type layered column and an additively manufactured porous honeycomb (AMPH) column. For columns with 25.4 cm of active height and run under similar conditions, the packed, plate‐type layering, and AMPH columns achieved approximate height equivalent of a theoretical plate (HETP) values of 5.5, 3.7, and 3.2 cm for nitrogen, and 5.9, 4.9, and 3.3 cm for argon. The AMPH column can produce up to 0.4 SLM of more than 90% purity oxygen with 12 W of cooling lift. These results demonstrate the feasibility of using additive manufacturing to construct MCD devices and pave a way for constructing novel MCD designs.

36 MATERIALS SCIENCE↗

Complex software dedicated for design and simulation of LPCE process for heavy water detritiation

The main purpose of this paper is to present a comprehensive software, SICA, designed to be used in water-hydrogen liquid phase catalytic exchange process (LPCE). The software calculates the water-gas catalytic isotopic exchange process, following the transfer of any H, D or T isotope from water to gas and vice versa. This software is useful for both design and laboratory-based research; the type of the catalytic filling (ordered or random) can be defined for any of these 2 cases, the isotopic calculation being specific to the package type. For the laboratory-based research, the performance of a catalytic packing can be determined by knowing the type and by using experimental results. Performance of the mixed catalytic packing is defined by mass transfer constants for each catalytic and hydrophilic package in that specific arrangement, and also for the isotope whose transfer is studied from one phase to another. Also, it has been established a link between these constants and commonly used parameters for the fillings performance defined by HETP (Height Equivalent of Theoretical Plate). To demonstrate the performance of the software, we present a comparative analysis of water-gas catalytic isotopic exchange on a column equipped with 3 types of filling: successive layers, random and structured (ordered package filled with catalyst). The program can be used for the LPCE process calculation, process used at detritiation facilities for CANDU reactors or fusion reactors. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental results of hydrogen distillation at the low power cryogenic column for the production of deuterium depleted hydrogen

The Deuterium Removal Unit (DRU) has been designed and built at the Petersburg Nuclear Physics Inst. (PNPI) to produce isotopically pure hydrogen with deuterium content less than 1 ppm. The cryogenic distillation column of 2.2 cm inner diameter and 155 cm packing height is the main element of the DRU. Column performances at different hydrogen distillation operating modes have been measured. The height equivalent to theoretical plate (HETP) for the column is 2.2 cm and almost constant over a wide range of vapour flow rates. Deuterium depleted hydrogen with a deuterium content of less than 0.1 ppm was produced in required quantity. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Augmented Monitoring and Condition Assessment Program for SNF Wet Storage Life Extension - 20489

Approximately 27 MTHM of spent nuclear fuel (SNF) owned and managed by the U.S. Department of Energy, Office of Environmental Management is stored in the L Basin at the Savannah River Site (SRS). This 'DOE SNF' is comprised of approximately 12,000 aluminum-clad, aluminum-based fuel assemblies (∼7 MTHM), and approximately 2000 non-aluminum fuel assemblies (∼20 MTHM). A program is in progress to perform Non-Destructive Examination (NDE) of the fuel and their storage containers to characterize the materials' condition, and to evaluate the effects of service to enable continued safe wet storage of the SNF. The Augmented Monitoring and Condition Assessment Program (AMCAP), a two-part program to develop and implement remote underwater Non-Destructive Examination of the aluminum SNF, and of the containers of the non-aluminum SNF, respectively, is aimed at the characterization and evaluation of corrosion degradation of aluminum fuel and container materials. The predominant design of the aluminum SNF (ASNF) stored in L Basin is the Materials Test Reactor (MTR) equivalent design, a plate fuel design. These SNF are stored in 5'' diameter tubes or 5'' x 5'' squares (called bundles) that are nominally 12' or up to 14' long. The SNF is de-bundled and inspected using a custom-designed MTR Fuel Inspection Table. The inspection table provides for indexed fuel positioning for a video camera examination with controlled lighting. A total of 10 of the SNF originating from foreign research and test reactors were selected for examination based on burnup, enrichment, and prior damage caused by service/storage history. A special inspection campaign of these 10 assemblies is in progress. The observed corrosion damage included minor to moderate attack from general corrosion, pitting, crevice, end grain and galvanic corrosion. Example results from the completed inspections are shown and discussed. The focus is a comparison of the as-received condition versus the as-found current storage condition that will serve to validate Water Chemistry and Corrosion Monitoring Programs. The non-aluminum SNF (NASNF) stored in L Basin are of diverse design that includes various geometries with claddings of stainless steel, Zircaloy, and Hastelloy. The fuel core materials include uranium alloys, oxides/mixed oxides, and carbides. These SNF materials, originating from early experimental and test reactors, are in various physical forms including single fuel elements and cut pieces. The fuel is stored in L Basin in various configurations including in direct bundled storage in aluminum tubes and in isolation cans that are in the bundles or in a larger over-size storage container (OSC). Concern with inside-out corrosion and the potential loss of configuration control and ability to handle the storage containers prompted the development of remote NDE methods that include visual and UT technologies to assess the condition of the containers. Candidate stored materials were selected for a special inspection campaign; the development of the NDE methods for the inspection for galvanic, crevice and sediment-induced corrosion (inside-out) are discussed. A summary of the SNF storage in L Basin at the SRS, and an overview of the AMCAP to enable continued safe storage of DOE SNF are described. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TU-D-201-03: Results of a Survey On the Implementation of the TG-51 Protocol and Associated Addendum On Reference Dosimetry of External Beams

Purpose: The working group on the review and extension of the TG-51 protocol (WGTG51) collected data from American Association of Physicists in Medicine (AAPM) members with respect to their current TG-51 and associated addendum usage in the interest of considering future protocol addenda and guidance on reference dosimetry best practices. This study reports an overview of this survey on dosimetry of external beams. Methods: Fourteen survey questions were developed by WGTG51 and released in November 2015. The questions collected information on reference dosimetry, beam quality specification, and ancillary calibration equipment. Results: Of the 190 submissions completed worldwide (U.S. 70%), 83% were AAPM members. Of the respondents, 33.5% implemented the TG-51 addendum, with the maximum calibration difference for any photon beam, with respect to the original TG-51 protocol, being <1% for 97.4% of responses. One major finding is that 81.8% of respondents used the same cylindrical ionization chamber for photon and electron dosimetry, implying that many clinics are foregoing the use of parallel-plate chambers. Other evidence suggests equivalent dosimetric results can be obtained with both cylindrical and parallel-plate chambers in electron beams. This, combined with users comfort with cylindrical chambers for electrons will likely impact recommendations put forward in an upcoming electron beam addendum to the TG-51 protocol. Data collected on ancillary equipment showed 58.2% (45.0%) of the thermometers (barometers) in use for beam calibration had NIST traceable calibration certificates, but 48.4% (42.7%) were never recalibrated. Conclusion: This survey provides a snapshot of TG-51 external beam reference dosimetry practice in radiotherapy centers. Findings demonstrate the rapid take-up of the TG-51 photon beam addendum and raise issues for the WGTG51 to focus on going forward, including guidelines on ancillary equipment and the choice of chamber for electron beam dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Physical properties and structure of fine core-shell particles used as packing materials for chromatography relationships between particle characteristics and column performance

The recent development of new brands of packing materials made of fine porous-shell particles, e.g., Halo and Kinetex, has brought great improvements in potential column efficiency, demanding considerable progress in the design of chromatographic instruments. Columns packed with Halo and Kinetex particles provide minimum values of their reduced plate heights of nearly 1.5 and 1.2, respectively. These packing materials have physical properties that set them apart from conventional porous particles. The kinetic performance of 4.6 mm I.D. columns packed with these two new materials is analyzed based on the results of a series of nine independent and complementary experiments: low-temperature nitrogen adsorption (LTNA), scanning electron microscopy (SEM), inverse size-exclusion chromatography (ISEC), Coulter counter particle size distributions, pycnometry, height equivalent to a theoretical plate (HETP), peak parking method (PP), total pore blocking method (TPB), and local electrochemical detection across the column exit section (LED). The results of this work establish links between the physical properties of these superficially porous particles and the excellent kinetic performance of columns packed with them. It clarifies the fundamental origin of the difference in the chromatographic performances of the Halo and the Kinetex columns.

36 MATERIALS SCIENCE↗

Characterization and response of three TNT equivalent materials in subsurface explosions

Energetic compositions utilized for inducing seismic responses are often referred to in terms of their TNT equivalent, a metric which is often misused because observations of interest are not often understood with respect to explosive characteristics. Here, in this investigation, we characterize three energetic compositions used to elicit seismic responses in a highly instrumented testbed to further our understanding of subsurface TNT equivalence. Three different energetic sources are prepared and studied for their fidelity to thermochemically predicted detonation behavior. We present effects of subsurface detonation on subsurface rock and seismic emission as a function of energetic source material within the testbed. Field experiments were conducted using a single thermochemical yield of 5 kg using diverse sources consisting of nitromethane, ammonal, and PBXN‐5 (an HMX based plastic bonded explosive) mixtures at the Energetic Materials Research and Testing Center in Socorro, New Mexico. Relative performance of energy density‐related detonation parameters, such as detonation velocity and pressure, affect the observed response in the subsurface. Most notable, equal thermochemical yields described in terms of TNT equivalence do not correlate to equal thermochemical effects in the subsurface.

Blue Canyon Dome↗

Microchannel reactive distillation for the conversion of aqueous ethanol to ethylene

Here we demonstrate the proof-of-concept for microchannel reactive distillation for alcohol-to-jet application: combining ethanol/water separation and ethanol dehydration in one unit operation. Ethanol is first distilled into the vapor phase, converted to ethylene and water, and then the water co-product is condensed to shift the reaction equilibrium. Process intensification is achieved through rapid mass transfer—ethanol stripping from thin wicks using novel microchannel architectures—leading to lower residence time and improved separation efficiency. Energy savings are realized with integration of unit operations. For example, heat of condensing water can offset vaporizing ethanol. Furthermore, the dehydration reaction equilibrium shifts towards completion by immediate removal of the water byproduct upon formation while maintaining aqueous feedstock in the condensed phase. For aqueous ethanol feedstock (40% w ), 71% ethanol conversion with 91% selectivity to ethylene was demonstrated at 220 °C, 600 psig, and 0.28 h -1 wt hour space velocity. 2.7 stages of separation were also demonstrated, under these conditions, using a device length of 8.3 cm. This provides a height equivalent of a theoretical plate (HETP), a measure of separation efficiency, of ~3.3 cm. By comparison, conventional distillation packing provides an HETP of ~30 cm. Thus, 9.1× reduction in HETP was demonstrated over conventional technology, providing a means for significant energy savings and an example of process intensification. Finally, preliminary process economic analysis indicates that by using microchannel reactive distillation technology, the operating and capital costs for the ethanol separation and dehydration portion of an envisioned alcohol-to-jet process could be reduced by at least 35% and 55%, respectively, relative to the incumbent technology, provided future improvements to microchannel reactive distillation design and operability are made.

10 SYNTHETIC FUELS↗

Influence of viscous friction heating on the efficiency of columns operated under very high pressures

When columns packed with very fine particles are operated at high mobile phase velocities, the friction of the mobile phase percolating through the column bed generates heat. This heat dissipates along and across the column and axial and radial temperature gradients appear. The wall region of the column tends to be cooler than its center, and due to the influence of temperature on the mobile phase viscosity and on the equilibrium constant of analytes, the band velocity is not constant across the column. This radial heterogeneity of the temperature distribution across the column contributes to band broadening. This phenomenon was investigated assuming a cylindrically symmetrical column and using the general dispersion theory of Aris, which relates the height equivalent to the theoretical plate (HETP) contribution due to a radial heterogeneity of the column to the radial distribution of the linear velocities of a compound peak and to the radial distribution of its apparent dispersion coefficients in the column bed. The former is known from the temperature gradient across the column, the temperature dependencies of the mobile phase viscosity, and the retention factor of the compound. The latter is derived from the known expression of the transverse reduced HETP equation for the column. The values of the HETP calculated with the Aris model and a classical HETP equation were compared to those measured on a 2.1 x 50 mm Acquity BEH-C{sub 18} column, run at flow rates of 0.6, 0.95, 1.30, and 1.65 mL/min, with pure acetonitrile as the mobile phase and naphtho[2,3-a]pyrene as the retained compound. These two sets of data are in generally good agreement, although the experimental values of the HETP tend to increase faster with increasing mobile phase velocity than the calculated values.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Separative analyses of a chromatographic column packed with a core-shell adsorbent for lithium isotope separation

Lithium-6 is used as a blanket material for sufficient tritium production in DT fueled fusion reactors. A core-shell type adsorbent was proposed for lithium isotope separation by chromatography. The mass transfer model in a chromatographic column consisted of 4 steps, such as convection and dispersion in the column, transfer through liquid films, intra-particle diffusion and and adsorption or desorption at the local adsorption sites. A model was developed and concentration profiles and time variation in the column were numerically simulated. It became clear that core-shell type adsorbents with thin porous shell were saturated rapidly relatively to fully porous one and established a sharp edge of adsorption band. This is very important feature because lithium isotope separation requires long-distance development of adsorption band. The values of HETP (Height Equivalent of a Theoretical Plate) for core-shell adsorbent packed column were estimated by statistical moments of the step response curve. The value of HETP decreased with the thickness of the porous shell. A core-shell type adsorbent is, then, useful for lithium isotope separation. (authors)

07 ISOTOPE AND RADIATION SOURCES↗