Search NASA⌕ Search

SEARCH · Search NASA

Results for “ERROR FREQUENCY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Quality Assurance Analysis of a Large Multicenter Practice: Does Increased Complexity of Intensity-Modulated Radiotherapy Lead to Increased Error Frequency?

Purpose: Error reduction is an important concern in clinical medicine. Intensity-modulated radiotherapy (IMRT) is an important advancement in radiation oncology that increases the complexity of treatment, potentially increasing the error risk. We studied the frequency and severity of errors in a large multicenter practice to ascertain the impact of quality improvement interventions over time, IMRT, and type of practice. Methods and Materials: We analyzed prospective data from three academic and 16 community practice sites with 24,775 courses of radiotherapy (9,210 IMRT courses and 15,565 non-IMRT) between January 2006 and December 2009. All IMRT treatment was performed using one centralized dose planning center for all sites. Results: We prospectively identified various errors or potential errors in 0.14 % vs. 0.40 % of the IMRT vs. non-IMRT courses (13/9,210 vs. 62/15,565, p = 0.0004) and excluding potential errors: 0.03 % for IMRT vs. 0.21% for non-IMRT. We developed the Clinical Radiotherapy Error Severity Scale (CRESS) to classify error severity from 1 to 10, with 1 to 3 for potential or completely correctable errors, 4 to 5 for dose variations <5%, and 6 to 10 for dose variations >5%. Multivariate analyses of CRESS values, severity >4, and any error (including potential) correlated significantly reduced errors with IMRT (p = 0.0001-0.0024) but found no significant difference between the academic and community practice sites and no change in error frequency over time despite implementation of 39 system-wide policy changes by the centralized quality improvement committee. Conclusions: Despite the increase in complexity with IMRT compared with conventional radiotherapy, it can be delivered with reduced error frequency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Sub-THz CMOS Molecular Clock with 20 ppt Stability at 10,000 s Based on A Dual-Loop Spectroscopic Detection and Digital Frequency Error Integration

This paper presents a dual-loop chip-scale molecular clock (CSMC), which enhances the Allan Deviation performance by combining high signal-to-noise ratio of using fundamental mode and long-term stability of using higher order modes in derivative molecular absorption spectroscopy. In addition, digital frequency-error integration is adopted in the frequency-locked loop to provide an infinite open-loop DC gain, which fully suppresses any frequency drift caused by the temperature-sensitive crystal oscillator. This new generation CSMC is implemented in 65-nm CMOS, and achieves 20 ppt (part-per-trillion) Allan Deviation at 10,000 s averaging time with 71-mW power consumption.

Han, Ruonan↗

Wind Power Forecasting Error Frequency Analyses for Operational Power System Studies: Preprint

The examination of wind power forecasting errors is crucial for optimal unit commitment and economic dispatch of power systems with significant wind power penetrations. This scheduling process includes both renewable and nonrenewable generators, and the incorporation of wind power forecasts will become increasingly important as wind fleets constitute a larger portion of generation portfolios. This research considers the Western Wind and Solar Integration Study database of wind power forecasts and numerical actualizations. This database comprises more than 30,000 locations spread over the western United States, with a total wind power capacity of 960 GW. Error analyses for individual sites and for specific balancing areas are performed using the database, quantifying the fit to theoretical distributions through goodness-of-fit metrics. Insights into wind-power forecasting error distributions are established for various levels of temporal and spatial resolution, contrasts made among the frequency distribution alternatives, and recommendations put forth for harnessing the results. Empirical data are used to produce more realistic site-level forecasts than previously employed, such that higher resolution operational studies are possible. This research feeds into a larger work of renewable integration through the links wind power forecasting has with various operational issues, such as stochastic unit commitment and flexible reserve level determination.

17 WIND ENERGY↗

Development of a measurement of upper MID frequency errors on arbitrary grazing incidence optics

Two state-of-the-art subsystems (detection and servo) were developed and performance generally more than an order of magnitude better than comparable commercial subsystems was achieved. Most importantly, though, the breadboard instrument measured more than an order of magnitude more accurately than the original 1 Angstrom goal within the primary spatial period range. Extensive measurements were taken, and a useful set of Phase 3 modifications were defined.

Glenn, Paul↗

Frequency-Tracking-Error Detector

Frequency-tracking-error detector compares average period of output signal from band-pass tracking filter with average period of signal of frequency 100 f(sub 0) that controls center frequency f(sub 0) of tracking filter. Measures difference between f(sub 0) and frequency of one of periodic components in output of bearing sensor. Bearing sensor is accelerometer, strain gauge, or deflectometer mounted on bearing housing. Detector part of system of electronic equipment used to measure vibrations in bearings in rotating machinery.

Randall, Richard L.↗

Temporal contrast degradation from mid-spatial-frequency surface error on stretcher mirrors

Temporal contrast degradation due to mid-spatial-frequency error in chirped-pulse amplification stretcher optics is studied. Third-order cross-correlation measurements reveal a temporal peak that appears when using two different mirrors processed by magnetorheological finishing, despite an improvement in rms roughness compared to a third unprocessed mirror. Simulations based on measured power spectral density show how the actual impact on contrast is different from measurements using a typical bandwidth-limited third-order cross correlator. Furthermore, strategies are proposed to avoid this type of contrast degradation while exploiting computer numerically controlled polishing techniques for enhancement of surface figure and roughness.

47 OTHER INSTRUMENTATION↗

PCR-Induced Transitions Are the Major Source of Error in Cleaned Ultra-Deep Pyrosequencing Data

Ultra-deep pyrosequencing (UDPS) is used to identify rare sequence variants. The sequence depth is influenced by several factors including the error frequency of PCR and UDPS. This study investigated the characteristics and source of errors in raw and cleaned UDPS data. UDPS of a 167-nucleotide fragment of the HIV-1 SG3Δenv plasmid was performed on the Roche/454 platform. The plasmid was diluted to one copy, PCR amplified and subjected to bidirectional UDPS on three occasions. The dataset consisted of 47,693 UDPS reads. Raw UDPS data had an average error frequency of 0.30% per nucleotide site. Most errors were insertions and deletions in homopolymeric regions. We used a cleaning strategy that removed almost all indel errors, but had little effect on substitution errors, which reduced the error frequency to 0.056% per nucleotide. In cleaned data the error frequency was similar in homopolymeric and non-homopolymeric regions, but varied considerably across sites. These site-specific error frequencies were moderately, but still significantly, correlated between runs (r = 0.15–0.65) and between forward and reverse sequencing directions within runs (r = 0.33–0.65). Furthermore, transition errors were 48-times more common than transversion errors (0.052% vs. 0.001%; p<0.0001). Collectively the results indicate that a considerable proportion of the sequencing errors that remained after data cleaning were generated during the PCR that preceded UDPS. A majority of the sequencing errors that remained after data cleaning were introduced by PCR prior to sequencing, which means that they will be independent of platform used for next-generation sequencing. The transition vs. transversion error bias in cleaned UDPS data will influence the detection limits of rare mutations and sequence variants.

59 BASIC BIOLOGICAL SCIENCES↗

An Experiment-based Distribution Level Performance Comparison among PMUs

This paper presents a experiment-based distribution level performance comparison among three Phasor Measurement Units (PMUs). Several evaluation criteria, including the total vector error, the phase angle error, the frequency error, the rate of change of frequency, the response time, the settling time, the overshoot, and the algorithm window size, are selected to compare the static and dynamic performances of the PMUs under steady state and step response test conditions. In order to have a more realistic test environment, a test is setup in which PMUs under evaluation have exactly the same input signals. The quantitative experiment result analysis gives an end-user guideline to the PMU selection regarding distribution level applications.

Yin, He↗

Demonstration of the frequency offset errors introduced by an incorrect setting of the Zeeman/magnetic field adjustment on the cesium beam frequency standard

The fine frequency setting of a cesium beam frequency standard is accomplished by adjusting the C field control with the appropriate Zeeman frequency applied to the harmonic generator. A novice operator in the field, even when using the correct Zeeman frequency input, may mistakenly set the C field to any one of seven major Beam I peaks (fingers) represented by the Ramsey curve. This can result in frequency offset errors of as much as 2.5 parts in ten to the tenth. The effects of maladjustment are demonstrated and suggestions are discussed on how to avoid the subtle traps associated with C field adjustments.

Kaufmann, D. C.↗

Supercapacitor to Provide Ancillary Services With Control Coordination

This paper proposes a dynamic frequency support scheme of a supercapacitor energy storage system (SCESS) in coordination with run-of-the-river-based pumped storage hydropower (PSH) to enhance the short-term frequency stability in a power system that has a high penetration of renewable energy. To achieve this, the proposed coordinated frequency controller (CFC) enables the SCESS and PSH plant to provide the frequency response. The CFC scheme employs a dynamic droop characteristic in parallel with an integral controller and a distribution function. The dynamic droop characteristic determines the power production for frequency regulation employing a variable gain, which varies with the total capacity of the frequency control units and magnitude of the system frequency error with time; the gain increases with the frequency error, and thereby, arresting the frequency nadir at a higher level than in the conventional droop characteristic. In addition, the distribution function dispatches the power from the dynamic droop and integral controller to the control units in proportion to their headrooms; furthermore, the distribution function considers a sudden loss of generation from an SCESS by its operational constraint during the frequency support. Thus, the proposed dynamic frequency support scheme can enhance the short-term frequency stability for a frequency event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cryogenic Pound Circuits for Cryogenic Sapphire Oscillators

Two modern cryogenic variants of the Pound circuit have been devised to increase the frequency stability of microwave oscillators that include cryogenic sapphire-filled cavity resonators. The original Pound circuit is a microwave frequency discriminator that provides feedback to stabilize a voltage-controlled microwave oscillator with respect to an associated cavity resonator. In the present cryogenic Pound circuits, the active microwave devices are implemented by use of state-of-the-art commercially available tunnel diodes that exhibit low flicker noise (required for high frequency stability) and function well at low temperatures and at frequencies up to several tens of gigahertz. While tunnel diodes are inherently operable as amplitude detectors and amplitude modulators, they cannot, by themselves, induce significant phase modulation. Therefore, each of the present cryogenic Pound circuits includes passive circuitry that transforms the AM into the required PM. Each circuit also contains an AM detector that is used to sample the microwave signal at the input terminal of the high-Q resonator for the purpose of verifying the desired AM null at this point. Finally, each circuit contains a Pound signal detector that puts out a signal, at the modulation frequency, having an amplitude proportional to the frequency error in the input signal. High frequency stability is obtained by processing this output signal into feedback to a voltage-controlled oscillator to continuously correct the frequency error in the input signal.

Dick, G. John↗

Design and Quasi-Equilibrium Analysis of a Distributed Frequency-Restoration Controller for Inverter-Based Microgrids

This paper discusses a proposed frequency restoration controller which operates as an outer loop to frequency droop for voltage-source inverters. By quasi-equilibrium analysis, we show that the proposed controller is able to provide arbitrarily small steady-state frequency error while maintaing power sharing between inverters without need for communication or centralized control. We derive rate of convergence, discuss design considerations (including a fundamental trade-off that must be made in design), present a design procedure to meet a maximum frequency error requirement, and show simulation results verifying our analysis and design method. The proposed controller will allow flexible plug-and-play inverter-based networks to meet a specified maximum frequency error requirement.

Distributed control↗

Modified LTR robust control for flexible structures

A procedure is developed for dealing with performance and robustness issues in the design of multi-input multi-output compensators for lightly damped flexible structures. The procedure is based upon representing errors in the plant design model as structured uncertainties, and applying a modified version of the Loop Transfer Recovery (LTR) design method. Real parameter errors, such as frequency errors, damping errors or modal displacement errors can be treated. The approach involves adjusting the cost function in the regulator problem and the process noise model in the estimator problem in a particular manner which reflects the assumed structure of the modeling errors. Numerical examples dealing with the control of a large flexible space antenna with uncertain frequencies demonstrate a considerable improvement over standard LTR methods. Convenient design parameters can be varied until a satisfactory compromise is achieved between performance and robustness.

Blelloch, P. A.↗