Search NASA⌕ Search

SEARCH · Search NASA

Results for “ERROR FREQUENCY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Sub-THz CMOS Molecular Clock with 20 ppt Stability at 10,000 s Based on A Dual-Loop Spectroscopic Detection and Digital Frequency Error Integration

This paper presents a dual-loop chip-scale molecular clock (CSMC), which enhances the Allan Deviation performance by combining high signal-to-noise ratio of using fundamental mode and long-term stability of using higher order modes in derivative molecular absorption spectroscopy. In addition, digital frequency-error integration is adopted in the frequency-locked loop to provide an infinite open-loop DC gain, which fully suppresses any frequency drift caused by the temperature-sensitive crystal oscillator. This new generation CSMC is implemented in 65-nm CMOS, and achieves 20 ppt (part-per-trillion) Allan Deviation at 10,000 s averaging time with 71-mW power consumption.

Han, Ruonan↗

Development of a measurement of upper MID frequency errors on arbitrary grazing incidence optics

Two state-of-the-art subsystems (detection and servo) were developed and performance generally more than an order of magnitude better than comparable commercial subsystems was achieved. Most importantly, though, the breadboard instrument measured more than an order of magnitude more accurately than the original 1 Angstrom goal within the primary spatial period range. Extensive measurements were taken, and a useful set of Phase 3 modifications were defined.

Glenn, Paul↗

Frequency-Tracking-Error Detector

Frequency-tracking-error detector compares average period of output signal from band-pass tracking filter with average period of signal of frequency 100 f(sub 0) that controls center frequency f(sub 0) of tracking filter. Measures difference between f(sub 0) and frequency of one of periodic components in output of bearing sensor. Bearing sensor is accelerometer, strain gauge, or deflectometer mounted on bearing housing. Detector part of system of electronic equipment used to measure vibrations in bearings in rotating machinery.

Randall, Richard L.↗

Demonstration of the frequency offset errors introduced by an incorrect setting of the Zeeman/magnetic field adjustment on the cesium beam frequency standard

The fine frequency setting of a cesium beam frequency standard is accomplished by adjusting the C field control with the appropriate Zeeman frequency applied to the harmonic generator. A novice operator in the field, even when using the correct Zeeman frequency input, may mistakenly set the C field to any one of seven major Beam I peaks (fingers) represented by the Ramsey curve. This can result in frequency offset errors of as much as 2.5 parts in ten to the tenth. The effects of maladjustment are demonstrated and suggestions are discussed on how to avoid the subtle traps associated with C field adjustments.

Kaufmann, D. C.↗

Cryogenic Pound Circuits for Cryogenic Sapphire Oscillators

Two modern cryogenic variants of the Pound circuit have been devised to increase the frequency stability of microwave oscillators that include cryogenic sapphire-filled cavity resonators. The original Pound circuit is a microwave frequency discriminator that provides feedback to stabilize a voltage-controlled microwave oscillator with respect to an associated cavity resonator. In the present cryogenic Pound circuits, the active microwave devices are implemented by use of state-of-the-art commercially available tunnel diodes that exhibit low flicker noise (required for high frequency stability) and function well at low temperatures and at frequencies up to several tens of gigahertz. While tunnel diodes are inherently operable as amplitude detectors and amplitude modulators, they cannot, by themselves, induce significant phase modulation. Therefore, each of the present cryogenic Pound circuits includes passive circuitry that transforms the AM into the required PM. Each circuit also contains an AM detector that is used to sample the microwave signal at the input terminal of the high-Q resonator for the purpose of verifying the desired AM null at this point. Finally, each circuit contains a Pound signal detector that puts out a signal, at the modulation frequency, having an amplitude proportional to the frequency error in the input signal. High frequency stability is obtained by processing this output signal into feedback to a voltage-controlled oscillator to continuously correct the frequency error in the input signal.

Dick, G. John↗

Modified LTR robust control for flexible structures

A procedure is developed for dealing with performance and robustness issues in the design of multi-input multi-output compensators for lightly damped flexible structures. The procedure is based upon representing errors in the plant design model as structured uncertainties, and applying a modified version of the Loop Transfer Recovery (LTR) design method. Real parameter errors, such as frequency errors, damping errors or modal displacement errors can be treated. The approach involves adjusting the cost function in the regulator problem and the process noise model in the estimator problem in a particular manner which reflects the assumed structure of the modeling errors. Numerical examples dealing with the control of a large flexible space antenna with uncertain frequencies demonstrate a considerable improvement over standard LTR methods. Convenient design parameters can be varied until a satisfactory compromise is achieved between performance and robustness.

Blelloch, P. A.↗

To Err is Normable: The Computation of Frequency-Domain Error Bounds from Time-Domain Data

This paper exploits the relationships among the time-domain and frequency-domain system norms to derive information useful for modeling and control design, given only the system step response data. A discussion of system and signal norms is included. The proposed procedures involve only simple numerical operations, such as the discrete approximation of derivatives and integrals, and the calculation of matrix singular values. The resulting frequency-domain and Hankel-operator norm approximations may be used to evaluate the accuracy of a given model, and to determine model corrections to decrease the modeling errors.

Hartley, Tom T.↗

Design Considerations of Polishing Lap for Computer-Controlled Cylindrical Polishing Process

This paper establishes a relationship between the polishing process parameters and the generation of mid spatial-frequency error. The consideration of the polishing lap design to optimize the process in order to keep residual errors to a minimum and optimization of the process (speeds, stroke, etc.) and to keep the residual mid spatial-frequency error to a minimum, is also presented.

Khan, Gufran S.↗

Radar error statistics for the space shuttle

Radar error statistics of C-band and S-band that are recommended for use with the groundtracking programs to process space shuttle tracking data are presented. The statistics are divided into two parts: bias error statistics, using the subscript B, and high frequency error statistics, using the subscript q. Bias errors may be slowly varying to constant. High frequency random errors (noise) are rapidly varying and may or may not be correlated from sample to sample. Bias errors were mainly due to hardware defects and to errors in correction for atmospheric refraction effects. High frequency noise was mainly due to hardware and due to atmospheric scintillation. Three types of atmospheric scintillation were identified: horizontal, vertical, and line of sight. This was the first time that horizontal and line of sight scintillations were identified.

Lear, W. M.↗

Optical Testing of Diamond Machined, Aspheric Mirrors for Groundbased, Near-IR Astronomy

The Infrared Multi-Object Spectrometer (IRMOS) is a facility-class instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8-2.5 micron) spectrometer and operates at approximately 80 K. The 6061-T651 aluminum bench and mirrors constitute an athermal design. The instrument produces simultaneous spectra at low- to mid-resolving power (R=lambda/delta lambda= 300-3000) of approximately 100 objects in its 2.8 x 2.0 arcmin field. We describe ambient and cryogenic optical testing of the IRMOS mirrors across a broad range in spatial frequency (figure error, mid-frequency error, and microroughness). The mirrors include three rotationally symmetric, off-axis conic sections, one off-axis biconic, and several flat fold mirrors. The symmetric mirrors include convex and concave prolate and oblate ellipsoids. They range in aperture from 94x86 mm to 286x269 mm and in f-number from 0.9 to 2.4. The biconic mirror is concave and has a 94x76 mm aperture, R(sub x)=377 mm, k(sub x)=0.0778, R(sub y)=407 mm, and k(sub y)=0.1265 and is decentered by -2 mm in X and 227 mm in Y. All of the mirrors have an aspect ratio of approximately 6:1. The surface error fabrication tolerances are less than 10 nm RMS microroughness, 'best effort' for mid-frequency error, and less than 63.3 nm RMS figure error. Ambient temperature (approximately 293 K) testing is performed for each of the three surface error regimes, and figure testing is also performed at approximately 80 K. Operation of the ADE Phaseshift MicroXAM white light interferometer (micro-roughness) and the Bauer Model 200 profilometer (mid-frequency error) is described. Both the sag and conic values of the aspheric mirrors make these tests challenging. Figure testing is performed using a Zygo GPI interferometer, custom computer generated holograms (CGH), and optomechanical alignment fiducials. Cryogenic CGH null testing is discussed in detail. We discuss complications such as the change in prescription with temperature and thermal gradients. Correction for the effect of the dewar window is also covered. We discuss the error budget for the optical test and alignment procedure. Data reduction is accomplished using commercial optical design and data analysis software packages. Results from CGH testing at cryogenic temperatures are encouraging thus far.

Chambers, V. John↗

Signal Analysis Algorithms for Optimized Fitting of Nonresonant Laser Induced Thermal Acoustics Damped Sinusoids

This study seeks a numerical algorithm which optimizes frequency precision for the damped sinusoids generated by the nonresonant LITA technique. It compares computed frequencies, frequency errors, and fit errors obtained using five primary signal analysis methods. Using variations on different algorithms within each primary method, results from 73 fits are presented. Best results are obtained using an AutoRegressive method. Compared to previous results using Prony s method, single shot waveform frequencies are reduced approx.0.4% and frequency errors are reduced by a factor of approx.20 at 303K to approx. 0.1%. We explore the advantages of high waveform sample rates and potential for measurements in low density gases.

Balla, R. Jeffrey↗

Initial Findings in Full-Shell Active Optics

The realization of active full-shell x-ray optics will provide ground-breaking capability for future missions. Future X-ray missions, such as Lynx, require high angular-resolution, large effective area, and as wide a field of view(FOV) as possible. It is currently not possible to perform high-resolution imaging of both wide and narrow FOVs with a single X-ray telescope. In this paper, we discuss the use of actuators to switch the optical surface of full-shell x-ray optics between prescriptions optimized for narrow-field and wide-field viewing, as well as correct for low-spatial-frequency errors in the optics. Previously, a pathfinder was developed using finite-element modeling(FEM). Using a combination of the model’s influence functions, the capacity of active full-shell optics was shown to switch between prescriptions with 92% accuracy. Another benefit of the analytical pathfinder was its ability to correct low-spatial frequency errors, which comprise a large percentage of the MSFC full-shell x-ray optics root-mean-square (RMS) slope error. In order to verify the pathfinder, a surface-parallel actuator was bonded to a nickel-replicated coupon. After the actuator was bonded to the coupon, the slope of the surface was measured while the actuator was activated. The proof-of-concept demonstrator development, the influence function data, and the resulting implications on the analytical pathfinder are reported and discussed.

X-ray optics↗

Use of Density Functional Method to Study Molecular Vibrations

Use of a scale factor reduces the errors in computed vibrational frequencies (errors due to anharmonicities, basis set deficiencies, and approximate treatment of electron correlation). Additional errors come from modelling solids with small molecules. Nevertheless, we hope that the present calculations add to the understanding of surface IR measurements of the heat tiles.

Chong, Delano P.↗

Effect of DM Actuator Errors on the WFIRST/AFTA Coronagraph Contrast Performance

The WFIRST/AFTA 2.4 m space telescope currently under study includes a stellar coronagraph for the imaging and the spectral characterization of extrasolar planets. The coronagraph employs two sequential deformable mirrors (DMs) to compensate for phase and amplitude errors in creating dark holes. DMs are critical elements in high contrast coronagraphs, requiring precision and stability measured in picometers to enable detection of Earth-like exoplanets. Working with a low-order wavefront-sensor the DM that is conjugate to a pupil can also be used to correct low-order wavefront drift during a scientific observation. However, not all actuators in a DM have the same gain. When using such a DM in low-order wavefront sensing and control subsystem, the actuator gain errors introduce high-spatial frequency errors to the DM surface and thus worsen the contrast performance of the coronagraph. We have investigated the effects of actuator gain errors and the actuator command digitization errors on the contrast performance of the coronagraph through modeling and simulations, and will present our results in this paper.

adaptive optics↗