Search NASA⌕ Search

SEARCH · Search NASA

Results for “ETDE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Improving Collision Induced Dissociation (CID), High Energy Collision Dissociation (HCD), and Electron Transfer Dissociation (ETD) Fourier Transform MS/MS Degradome-Peptidome Identifications Using High Accuracy Mass Information

Identification of peptides through analysis of peptide ion fragmentation mass spectra is key to proteomic/peptidomic studies. Advanced mass spectrometry has enabled measurement of peptide fragments with {approx}ppm mass error levels; however, mass accuracy has not been widely utilized in broad aspects of peptide identification. In this work we describe how peptide high-precision fragments measured with Fourier transform mass spectrometry can provide a powerful discriminative capability to distinguish true peptide 'hits' from possible incorrect peptides. For identification of peptides having multiple termini and carrying multiple charges, we show that the simple utilization of high-precision mass fragments information results in improved peptide analysis coverage and consistency, with coverage of >95% peptides identified totally from different spectral scoring and peptide statistic probability methods developed for moderate accuracy mass spectral peptide identification.

59 BASIC BIOLOGICAL SCIENCES↗

Effectiveness of CID, HCD, and ETD with FT MS/MS for Degradomic-Peptidomic Analysis: Comparison of Peptide Identification Methods

We report on use of an Orbitrap Velos mass spectrometer for comparison of fragmentation methods namely CID-, HCD-, and ETD for FT MS/MS analysis of human blood plasma peptidomic peptides. The peptidomic peptides were able to be identified from CID, HCD, and ETD spectra on specific confidence levels (e.g., 1% false discovery rate) with use of conventional SEQUEST database search software, and the number of identified peptides was increased by ~50% using accurate fragments (e.g., with mass tolerance of 0.05Da) in comparison with traditional moderate accuracy fragments (e.g., with 1 Da mass tolerance) for database search. However, the peptide datasets identified with such decoy search strategy were found to be varied by ~25% in the dataset size and ~20% in the dataset content with type of decoy database and precursor mass tolerances used for database search. CID was evaluated as the largest contributor to the identified peptide datasets, and HCD, and ETD provided ~20% and ~22% respectively additional peptides with accurate fragments for peptide identification, in contrast to ~25% and ~13% respectively with use of moderate accuracy fragments. When long (typically ≥7 amino acids) sequences were used for identification of peptides from the previously published UStags and de novo sequencing methods, HCD was evaluated as the largest contributor, and CID and ETD provided ~26% and ~8% respectively additional peptides from the UStags method and ~26% and ~6% respectively additional peptides from the de novo sequencing method. The peptide datasets identified with the UStags method were little influenced by the decoy database and mass tolerance and 98-99% peptide overlaps could be achieved between these datasets. CID, HCD, and ETD contributed their identifications of various charge state peptides in the m/z range highly overlapped and complementary implementation of CID, HCD, and ETD should be applied to maximize the number of peptides identified. Finally, the investigation presented in this work suggests that selection of fragmentation methods benefits significantly from a careful match with data analysis method applied for identification of peptides and the analysis throughput desired for various purposes of peptidomic-degradomic analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Electron Transfer Dissociation of All Ions at All Times, MS{sup ETD}, in a Quadrupole Time-of-Flight (Q-ToF) Mass Spectrometer

Data-independent mass spectral acquisition is particularly powerful when combined with ultra-performance liquid chromatography (LC) that provides excellent separation of most components present in a given sample. Data-independent analysis (DIA) consists of alternating full MS scans and scans with fragmentation of all ions within a selected m/z range, providing precursor masses and structure information, respectively. Fragmentation spectra are acquired either by sequential isolation and fragmentation of sliding m/z ranges or fragmenting all ions entering the MS instrument with no ion isolation, termed broadband DIA. Previously, broadband DIA has only been possible using collision induced dissociation (CID). Here, we report the use of electron transfer dissociation (ETD) as the fragmentation technique in broadband DIA instead of traditional collision induced dissociation (CID) during MS{sup E}. In this approach, which we refer to as MS{sup ETD}, we implement the inherent benefits provided by ETD, such as discrimination of leucine and isoleucine, in a DIA setup. The combination of DIA analysis and ETD fragmentation with supplemental CID energy provides a powerful platform to obtain information on all precursors and their sequence from a single experiment. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

What Hinders Electron Transfer Dissociation (ETD) of DNA Cations?

Radical activation methods, such as electron transfer dissociation (ETD), produce structural information complementary to collision-induced dissociation. Herein, electron transfer dissociation of 3-fold protonated DNA hexamers was studied to gain insight into the fragmentation mechanism. The fragmentation patterns of a large set of DNA hexamers confirm cytosine as the primary target of electron transfer. The reported data reveal backbone cleavage by internal electron transfer from the nucleobase to the phosphate linker leading either to a•/w or d/z• ion pairs. This reaction pathway contrasts with previous findings on the dissociation processes after electron capture by DNA cations, suggesting multiple, parallel dissociation channels. However, all these channels merely result in partial fragmentation of the precursor ion because the charge-reduced DNA radical cations are quite stable. Two hypotheses are put forward to explain the low dissociation yield of DNA radical cations: it is either attributed to non-covalent interactions between complementary fragments or to the stabilization of the unpaired electron in stacked nucleobases. MS{sup 3} experiments suggest that the charge-reduced species is the intact oligonucleotide. Moreover, introducing abasic sites significantly increases the dissociation yield of DNA cations. Consequently, the stabilization of the unpaired electron by π–π-stacking provides an appropriate rationale for the high intensity of DNA radical cations after electron transfer. .

74 ATOMIC AND MOLECULAR PHYSICS↗

UV–Vis Photodissociation Action Spectroscopy on Thermo LTQ-XL ETD and Bruker amaZon Ion Trap Mass Spectrometers: a Practical Guide

We report automated procedures for multiple tandem mass spectra acquisition allowing UV–Vis photodissociation action spectroscopy measurements of ions and radicals. The procedures were developed for two commercial ion trap mass spectrometers and applied to collision-induced and electron–transfer dissociation tandem mass spectrometry modes of ion generation. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dosimetric characteristics and quality control tests for the collimator sectors of the Leksell Gamma Knife Perfexion{sup TM}

Purpose: The purpose of this study was to evaluate the dosimetric characteristics of each sector of the Leksell Gamma Knife Perfexion (LGK PFX) and to develop tests that can be done for the routine quality assurance checks of the sectors of the LGK PFX. Methods: The following tests were performed to evaluate the dosimetric characteristics of the sectors: (1) Flash-radiation dose for the 16 mm collimator, (2) transit-radiation dose for the 8 and 4 mm collimators, (3) sector leakage within the radiation cavity and, (4) sector output uniformity. In these tests, the Elekta ABS phantom was used. A micropoint ion-chamber Exradin A16 was placed at the center of the phantom for all measurements. Results: With the version 8.0 of the control software of the MCU in the LGK PFX, the average flash-radiation dose per sector for the 16 mm collimator was measured to be 0.423 {+-} 0.003 cGy, and the average transit-radiation dose per sector for the 8 and 4 mm collimators was measured to be 0.169 {+-} 0.0009 and 0.147 {+-} 0.020 cGy, respectively. The calibration dose rate on the day of measurements was 280.8 cGy/min. Here, the authors have introduced a new concept of ''equivalent-time-duration'' (ETD) to represent the time duration, during which the flash-radiation or the transit-radiation dose is delivered. The ETD is a quotient of the measured dose of the flash-radiation or the transit-radiation and the respective calibrated dose rate for the 16, 8, or 4 mm collimator. The ETD constancy is an indicator of the constancy of the sector movements. The average value of ETD per sector was measured to be 724 {+-} 6, 313 {+-} 2, and 311 {+-} 45 ms for the 16, 8, and 4 mm collimators, respectively. During monthly spot checks, the authors have been measuring the total ETD for the flash-radiation when all eight sectors are open with the 16 mm collimator. The average value of the total ETD of the last 40 consecutive months was measured to be 642 {+-} 10 ms. This number is a useful quality parameter for the LGK PFX, which can be used to establish the base-line performance of the collimators of the LGK PFX. The reader is alerted that with the newly introduced version 9.0 of the control software of the MCU in the LGK PFX, the flash-radiation and the transit-radiation doses have become practically zero due to the fact that the treatment time is now corrected to compensate for these radiation doses. The sector output uniformity for the 16, 8, and 4 mm collimators was determined to be 98.9%, 97.3%, and 96.6%, respectively. The total leakage radiation with in the radiation cavity from all sectors was measured to be 0.17% of the dose output for the 16 mm collimator. Conclusions: Our measurements show that the dosimetric characteristics of all sectors of the LGK PFX are satisfactory. The authors recommend that the sector performance of the LGK PFX be determined initially at the time of installation of the LGK PFX and thereafter, at least annually. Similarly, our recommendation is that the total flash-radiation dose for the 16 mm collimator and the corresponding ETD value be measured on a monthly basis. Should any change in the sector movement occur, it will be revealed by the sector performance and the measurement of ETD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined Pulsed-Q dissociation and electron transfer dissociation for identification and quantitation of iTRAQ–labeled phosphopeptides

Multiplex isobaric tags for relative and absolute quantification (iTRAQ) enable high-throughput quantification of peptides via reporter ion signals in the low mass range of tandem mass spectra. A challenging but highly promising application is to analyze iTRAQ-labeled peptides using a sensitive linear ion trap mass spectrometer (LTQ-MS) and pulsed Q dissociation (PQD), a form of ion trap collision activated dissociation (CAD) designed to allow detection of low mass-to-charge fragment ions. Electron dissociation transfer (ETD), on the other hand, is complementary to PQD and is especially useful for sequencing peptides containing post-translational modifications (PTMs). Here, we developed an integrated workflow for robust and accurate quantitative identification of iTRAQ labeled phosphopeptides that integrates the PQD and ETD fragmentation methods together with PQD optimization, data management and bioinformatics tools. Analysis of the phosphoproteome of human fibroblast cells demonstrated that this hybrid mode is superior to either PQD or ETD alone for phosphopeptide identification and quantitation. The combined PQD/ETD approach can qualitatively identify additional phosphopeptides than ETD alone and PQD information can provide better quantitation of ETD identified iTRAQ-labeled phosphopeptides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Localized Exponential Time Differencing Method for Shallow Water Equations: Algorithms and Numerical Study

Here, we explore the performance of the exponential time differencing (ETD) method applied to the rotating shallow water equations. Comparing with explicit time stepping of the same order accuracy in time, the ETD algorithms could reduce the computational time in many cases by allowing the use of large time step sizes while still maintaining numerical stability. To accelerate the ETD simulations, we propose a localized approach that synthesizes the ETD method and overlapping domain decomposition. By dividing the original problem into many subdomain problems of smaller sizes and solving them locally, the proposed approach could speed up the calculation of matrix exponential vector products. Several standard test cases for shallow water equations of one or multiple layers are considered. The results show great potential of the localized ETD method for high-performance computing because each subdomain problem can be naturally solved in parallel at every time step.

58 GEOSCIENCES↗

Front-End Electron Transfer Dissociation Coupled to a 21 Tesla FT-ICR Mass Spectrometer for Intact Protein Sequence Analysis

High resolution mass spectrometry is a key technology for in-depth protein characterization. High-field Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) enables high-level interrogation of intact proteins in the most detail to date. However, an appropriate complement of fragmentation technologies must be paired with FTMS to provide comprehensive sequence coverage, as well as characterization of sequence variants, and post-translational modifications. Here we describe the integration of front-end electron transfer dissociation (FETD) with a custom-built 21 tesla FT-ICR mass spectrometer, which yields unprecedented sequence coverage for proteins ranging from 2.8 to 29 kDa, without the need for extensive spectral averaging (e.g., ~60% sequence coverage for apo-myoglobin with four averaged acquisitions). The system is equipped with a multipole storage device separate from the ETD reaction device, which allows accumulation of multiple ETD fragment ion fills. Consequently, an optimally large product ion population is accumulated prior to transfer to the ICR cell for mass analysis, which improves mass spectral signal-to-noise ratio, dynamic range, and scan rate. We find a linear relationship between protein molecular weight and minimum number of ETD reaction fills to achieve optimum sequence coverage, thereby enabling more efficient use of instrument data acquisition time. Finally, real-time scaling of the number of ETD reactions fills during method-based acquisition is shown, and the implications for LC-MS/MS top-down analysis are discussed. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parallel exponential time differencing methods for geophysical flow simulations

Two ocean models are considered for geophysical flow simulations: the multilayer shallow water equations and the multilayer primitive equations. For the former, we investigate the parallel performance of exponential time differencing (ETD) methods, including exponential Rosenbrock–Euler, ETD2wave, and B-ETD2wave. For the latter, we take advantage of the splitting of barotropic and baroclinic modes and propose a new two-level method in which an ETD method is applied to solve the fast barotropic mode. Furthermore, these methods could improve the computational efficiency of numerical simulations because ETD methods allow for much larger time step sizes than traditional explicit time-stepping techniques that are commonly used in existing computational ocean models. Several standard benchmark tests for ocean modeling are performed and comparison of the numerical results demonstrates a great potential of applying the parallel ETD methods for simulating real-world geophysical flows.

54 ENVIRONMENTAL SCIENCES↗

Overlapping localized exponential time differencing methods for diffusion problems

The localized exponential time differencing (ETD) based on overlapping domain decomposition has been recently introduced for extreme-scale phase field simulations of coarsening dynamics, which displays excellent parallel scalability in supercomputers. This paper serves as the first step toward building a solid mathematical foundation for this approach. We study the overlapping localized ETD schemes for a model time-dependent diffusion equation discretized in space by the standard central difference. Two methods are proposed and analyzed for solving the fully discrete localized ETD systems: the first one is based on Schwarz iteration applied at each time step and involves solving stationary problems in the subdomains at each iteration, while the second one is based on the Schwarz waveform relaxation algorithm in which time-dependent subdomain problems are solved at each iteration. The convergences of the associated iterative solutions to the corresponding fully discrete localized ETD solution and to the exact semidiscrete solution are rigorously proved. Finally, numerical experiments are also carried out to confirm theoretical results and to compare the performance of the two methods.

58 GEOSCIENCES↗

Analysis of Non-Enzymatically Glycated Peptides: Neutral-Loss Triggered MS3 Versus Multi-Stage Activation Tandem Mass Spectrometry

Non-enzymatic glycation of tissue proteins has important implications in the development of complications of diabetes mellitus. While electron transfer dissociation (ETD) has been shown to outperform collision-induced dissociation (CID) in sequencing glycated peptides by tandem mass spectrometry, ETD instrumentation is not yet available in all laboratories. In this study, we evaluated different advanced CID techniques (i.e., neutral-loss triggered MS3 and multi-stage activation) during LC-MSn analyses of Amadori-modified peptides enriched from human serum glycated in vitro. During neutral-loss triggered MS3 experiments, MS3 scans triggered by neutral-losses of 3 H2O or 3 H2O + HCHO produced similar results in terms of glycated peptide identifications. However, neutral losses of 3 H2O resulted in significantly more glycated peptide identifications during multi-stage activation experiments. Overall, the multi-stage activation approach produced more glycated peptide identifications, while the neutral-loss triggered MS3 approach resulted in much higher specificity. Both techniques offer a viable alternative to ETD for identifying glycated peptides when that method is unavailable.

59 BASIC BIOLOGICAL SCIENCES↗

Optimizing Travel Time to Outpatient Interventional Radiology Procedures in a Multi-Site Hospital System Using a Google Maps Application

The purpose of this study is to determine whether a custom Google Maps application can optimize site selection when scheduling outpatient interventional radiology (IR) procedures within a multi-site hospital system. The Google Maps for Business Application Programming Interface (API) was used to develop an internal web application that uses real-time traffic data to determine estimated travel time (ETT; minutes) and estimated travel distance (ETD; miles) from a patient’s home to each a nearby IR facility in our hospital system. Hypothetical patient home addresses based on the 33 cities comprising our institution’s catchment area were used to determine the optimal IR site for hypothetical patients traveling from each city based on real-time traffic conditions. For 10/33 (30%) cities, there was discordance between the optimal IR site based on ETT and the optimal IR site based on ETD at non-rush hour time or rush hour time. By choosing to travel to an IR site based on ETT rather than ETD, patients from discordant cities were predicted to save an average of 7.29 min during non-rush hour (p = 0.03), and 28.80 min during rush hour (p < 0.001). Using a custom Google Maps application to schedule outpatients for IR procedures can effectively reduce patient travel time when more than one location providing IR procedures is available within the same hospital system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nonoverlapping Localized Exponential Time Differencing Methods for Diffusion Problems

In this paper, we propose nonoverlapping localized exponential time differencing (ETD) methods for diffusion problems. The model time-dependent diffusion equation is first reformulated on subdomains based on the nonoverlapping domain decomposition, in which Neumann boundary conditions are imposed on the interfaces for the subdomain problems and Dirichlet type conditions are enforced to form a space-time interface problem. After spatial discretization by standard central finite differences and temporal integration with the first or second order ETD methods, the fully discrete interface problem is obtained. Such an interface problem is then solved iteratively either at each time step or over the whole time interval: the former involves the solution of stationary problems in each subdomain at each iteration while the latter involves the solution of time-dependent subdomain problems at each iteration. For both approaches, we prove that localized ETD solutions conserve mass exactly and converge in time to the exact space semidiscrete solution. Numerical experiments in two dimensions are also presented to illustrate the performance of the proposed methods.

Mass conservation↗