Search NASA⌕ Search

SEARCH · Search NASA

Results for “ETR REACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Improving to the neutron fluence rate monitor measurement system at the Advanced Test Reactor [Poster]

The existing fluence monitor wire scanning system at the Advanced Test Reactor (ATR) was designed and installed for use in the Engineering Test Reactor (ETR) when it began operation in 1958. The wire scanner was operated in ETR for over 20 years until ATR began operation, when it was moved to the ATR west canal area in 1971 and subsequently moved to the west canal in 2006 where it presently resides. With a continued service life of 65 years the system is well beyond the typical design life of 20 years for these types of systems. The need to update the data acquisition and control system was identified, and the benefits of replacing the existing sodium iodide (NaI) detector with an electronically cooled high-purity germanium (HPGe) detector are discussed. The wirescanner system in the ATR canal is utilized after every reactor cycle by the ATR Radiation Measurements Laboratory (RML) to assess the activation of cobalt and nickel dosimeter wires during the cycle. These wires become activated through exposure to thermal and fast neutrons respectively during the irradiation cycle and are highly radioactive upon shutdown. It is for this reason that the wirescanner is used in the ATR canal rather than transporting the dosimeters to another facility. A scoping study was performed to develop a base-line design to ensure that existing capabilities could be replaced with a new system. The new hardware will enable automated measuring of several flux monitor holders without necessitating the removal of the flux wires. In this way, flux wire measurements will be performed with minimal dose to the technicians and will not be limited by canal operations as is presently the case. The new control and acquisition software will be based on commercially available and supported systems that have a wide user-base to provide long-term stability. An electronically cooled HPGe detector will be used to provide high-resolution gamma-ray measurements, an improvement from the low-resolution sodium-iodide detector that is presently deployed. The electronic cooler eliminates the need for liquid nitrogen to cool the detector head. A new collimator has been designed to house the new detector and allow for sufficient counting rates.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improving to the neutron fluence rate monitor measurement system at the Advanced Test Reactor

The existing fluence monitor wire scanning system at the Advanced Test Reactor (ATR) was designed and installed for use in the Engineering Test Reactor (ETR) when it began operation in 1958. The wire scanner was operated in ETR for over 20 years until ATR began operation, when it was moved to the ATR west canal area in 1971 and subsequently moved to the west canal in 2006 where it presently resides. With a continued service life of 65 years the system is well beyond the typical design life of 20 years for these types of systems. The need to update the data acquisition and control system was identified, and the benefits of replacing the existing sodium iodide (NaI) detector with an electronically cooled high-purity germanium (HPGe) detector are discussed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SCALE Code Validation for Prismatic High-Temperature Gas-Cooled Reactors

Using experimental data published in the International Handbook of Evaluated Reactor Physics Benchmark Experiments for the fresh cold core of the High Temperature Engineering Test Reactor, a comprehensive validation study has been carried out to assess the performance of the SCALE code system for analysis of High Temperature Gas-Cooled Reactor (HTGR) configurations. This paper describes part of the results of this effort. The studies performed included criticality evaluations for the full core and for the annular cores realized during the fuel loading, as well as calculations and comparisons for excess reactivity, shutdown margin, control rod worths, temperature coefficient of reactivity, and reaction rate distributions. Comparisons of the SCALE results with both the experimental values and MCNP-calculated values are presented. The comparisons show that the SCALE calculated results, obtained with both multigroup and continuous energy cross sections, are in reasonable agreement with the experimental data. The agreement with the MCNP predictions is, in general, very good.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preliminary consideration of CFETR ITER-like case diagnostic system

Chinese Fusion Engineering Test Reactor (CFETR) is a new superconducting tokamak device being designed in China, which aims at bridging the gap between ITER and DEMO, where DEMO is a tokamak demonstration fusion reactor. Two diagnostic cases, ITER-like case and towards DEMO case, have been considered for CFETR early and later operating phases, respectively. In this paper, some preliminary consideration of ITER-like case will be presented. Based on ITER diagnostic system, three versions of increased complexity and coverage of the ITER-like case diagnostic system have been developed with different goals and functions. Version A aims only machine protection and basic control. Both of version B and version C are mainly for machine protection, basic and advanced control, but version C has an increased level of redundancy necessary for improved measurements capability. The performance of these versions and needed R&D work are outlined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Remove Welding Residual Stress for CFETR Vacuum Vessel by Trailing Ultrasonic Impact Treatment

The China fusion engineering test reactor (CFETR) vacuum vessel is welded by narrow gap TIG (NG-TIG) welding, and the welding residual stress of the CFETR vacuum vessel can be redistributed by trailing welding ultrasonic impact treatment. In order to investigate the feasibility of the residual stress removing scheme, and to obtain the optimal trailing ultrasonic impact treatment technological parameters in the process of removing welding residual stress, a welding model that similar to vacuum vessel welding seam is established by using ABAQUS software, a NG-TIG welding heat source subroutine which is written in FORTRAN language used to simulate NG-TIG welding. According to the welding simulation results, a trailing welding ultrasonic impact treatment model is established, and the effects of the impact pin number, the impact method, the impact pin diameter and the impact frequency on welding residual stress are studied. The results show that the longitudinal residual stress in welding seam and its adjacent area and the lateral residual stress in the whole region have been obviously decreased by different trailing welding ultrasonic impact processes, and have made the tensile stress in the welding seam and its adjacent area has been changed into compressive stress, which can provide theoretical guidance and reference for actual production.

36 MATERIALS SCIENCE↗

The Advanced Test Reactor

The Advanced Test Reactor (ATR) is currently the highest-powered research reactor in the world with a maximum thermal power of 250 MW. The ATR began operation in 1967 to support fuels and materials irradiation testing programs in the United States and current plans (2019) are to operate the ATR for two more decades. Since 2007, the ATR has been designated a National Scientific User Facility (NSUF) to provide more access for non-government researchers to use the ATR for academic irradiation research. This article is a brief description of the ATR history, construction, and experiment configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗