Search NASA⌕ Search

SEARCH · Search NASA

Results for “EUROPEAN SYNCHROTRON RADIATION FACILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A new white beam x-ray microdiffraction setup on the BM32 beamline at the European Synchrotron Radiation Facility

A white beam microdiffraction setup has been developed on the bending magnet source BM32 at the European Synchrotron Radiation Facility. The instrument allows routine submicrometer beam diffraction to perform orientation and strain mapping of polycrystalline samples. The setup features large source to optics distances allowing large demagnification ratios and small beam sizes. The optics of the beamline is used for beam conditioning upstream a secondary source, suppressing any possible interference of beam conditioning on beam size and position. The setup has been designed for an easy and efficient operation with position control tools embedded on the sample stage, a high magnification large aperture optical microscope, and fast readout detectors. Switching from the white beam mode to the monochromatic mode is made easy by an automatic procedure and allows the determination of both the deviatoric and hydrostatic strain tensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stitching methods at the European Synchrotron Radiation Facility (ESRF)

X-ray mirror quality has continuously improved over the past 20 years and manufacturers are now able to provide long mirrors with slope errors below 0.2 μrad. Nevertheless, these mirrors are mounted on holders or even mechanical benders to adjust their curvature and their intrinsic quality must be preserved from any parasitic deformation such as twist. The most direct method of detecting these deformations is to measure the 3D topography of the optical surface. At the ESRF metrology laboratory, three different stitching systems are under development based on Fizeau sub-aperture measurements. The first one consists of measuring long flat mirrors, the second based on the relative angle determinable stitching interferometry (RADSI) method developed at SPring-8 is aimed primarily at the measurement of short mirrors with strong curvature down to a few meters, and the last, also based on the RADSI method, is dedicated to characterize longer mirrors with intermediate curvature. For each method we will describe the measurement setup and discuss first results obtained. Micro-stitching interferometry is also currently used at the ESRF metrology laboratory. The technique is suitable for measuring deeply curved aspherical profiles and will be illustrated with results from a Kirkpatrick-Baez mirror system for nano-focusing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Crystallization and preliminary X-ray diffraction analysis on the homing endonuclease I-Dmo-I in complex with its target DNA

I-Dmo-I is a well characterized homing endonuclease from the archaeon Desulfurococcus mobilis. The enzyme was cloned and overexpressed in Escherichia coli. Crystallization experiments of I-Dmo-I in complex with its DNA target in the presence of Ca{sup 2+} and Mg{sup 2+} yielded crystals that were suitable for X-ray diffraction analysis. Homing endonucleases are highly specific DNA-cleaving enzymes that recognize long stretches of base pairs. The availability of these enzymes has opened novel perspectives for genome engineering in a wide range of fields, including gene therapy, by taking advantage of the homologous gene-targeting enhancement induced by a double-strand break. I-Dmo-I is a well characterized homing endonuclease from the archaeon Desulfurococcus mobilis. The enzyme was cloned and overexpressed in Escherichia coli. Crystallization experiments of I-Dmo-I in complex with its DNA target in the presence of Ca{sup 2+} and Mg{sup 2+} yielded crystals that were suitable for X-ray diffraction analysis. The crystals belonged to the monoclinic space group P2{sub 1}, with unit-cell parameters a = 106.75, b = 70.18, c = 106.85 Å, α = γ = 90, β = 119.93°. The self-rotation function and the Matthews coefficient suggested the presence of three protein–DNA complexes per asymmetric unit. The crystals diffracted to a resolution limit of 2.6 Å using synchrotron radiation at the Swiss Light Source (SLS) and the European Synchrotron Radiation Facility (ESRF)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Extremely asymmetric diffraction as a method of determining magneto-optical constants for X-rays near absorption edges

The spectral dependence of the Bragg peak position under conditions of extremely asymmetric diffraction has been analyzed in the kinematical and dynamical approximations of the diffraction theory. Simulations have been performed for the L{sub 3} absorption edge of yttrium in a single-crystal YFe{sub 2} film; they have shown that the magneto-optical constants (or, equivalently, the dispersion corrections to the atomic scattering factor) for hard X-rays can be determined from this dependence. Comparison with the experimental data obtained for a Nb(4 nm)/YFe{sub 2}(40 nm〈110〉)/Fe(1.5 nm)/Nb(50 nm)/sapphire sample at the European Synchrotron Radiation Facility has been made.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

X-ray fluorescence studies for the elemental composition and molecular organization of protein films on the surface of the liquid subphase

This paper reports on the results of the investigation of protein films that are based on alkaline phosphatase and glucose oxidase enzymes and formed on the surface of the liquid subphase. The experimental studies have been performed using total external reflection X-ray fluorescence spectrometry at the European Synchrotron Radiation Facility (Grenoble, France). The self-organization processes that occur in protein systems on the surface of the liquid subphase under the conditions where the protein molecules retain their mobility have been investigated using X-ray fluorescence measurements for the first time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measuring The Source Brilliance at An Undulator Beamline

Third-generation X-ray synchrotrons like the European Synchrotron Radiation Facility (ESRF) are optimized to produce intense undulator radiation. Insertion devices, such as undulators, ensure the highest possible brilliance--the key parameter for the success of e.g. coherent scattering, which is one of the main techniques employed at ESRF's TROIKA beamline. Nowadays, the constant efforts to reduce the emittance and improve the stability of the electron beam allow using small-gap insertion devices and increase the brilliance. Obviously, it is important to have an experimental technique for evaluating the performance of the undulator source. Here we present a method based on measuring the diffuse scattering from a light amorphous material by a photon counting detector. The measured spectral intensities show a very good agreement with the simulated spectra, demonstrating the high brilliance (above 10{sup 20} ph/s/0.1%bw/mrad{sup 2}/mm{sup 2}) achieved at modern facilities.

43 PARTICLE ACCELERATORS↗

ISPyB for BioSAXS, the gateway to user autonomy in solution scattering experiments

The ISPyB information-management system for crystallography has been adapted to include data from small-angle X-ray scattering of macromolecules in solution experiments. Logging experiments with the laboratory-information management system ISPyB (Information System for Protein crystallography Beamlines) enhances the automation of small-angle X-ray scattering of biological macromolecules in solution (BioSAXS) experiments. The ISPyB interface provides immediate user-oriented online feedback and enables data cross-checking and downstream analysis. To optimize data quality and completeness, ISPyBB (ISPyB for BioSAXS) makes it simple for users to compare the results from new measurements with previous acquisitions from the same day or earlier experiments in order to maximize the ability to collect all data required in a single synchrotron visit. The graphical user interface (GUI) of ISPyBB has been designed to guide users in the preparation of an experiment. The input of sample information and the ability to outline the experimental aims in advance provides feedback on the number of measurements required, calculation of expected sample volumes and time needed to collect the data: all of this information aids the users to better prepare for their trip to the synchrotron. A prototype version of the ISPyBB database is now available at the European Synchrotron Radiation Facility (ESRF) beamline BM29 and is already greatly appreciated by academic users and industrial clients. It will soon be available at the PETRA III beamline P12 and the Diamond Light Source beamlines I22 and B21.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Automated data collection based on RoboDiff at the ESRF beamline MASSIF-1

The European Synchrotron Radiation Facility has a long standing history in the automation of experiments in Macromolecular Crystallography. MASSIF-1 (Massively Automated Sample Screening and evaluation Integrated Facility), a beamline constructed as part of the ESRF Upgrade Phase I program, has been open to the external user community since July 2014 and offers a unique completely automated data collection service to both academic and industrial structural biologists.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative comparison of direct phase retrieval algorithms in in-line phase tomography

A well-known problem in x-ray microcomputed tomography is low sensitivity. Phase contrast imaging offers an increase of sensitivity of up to a factor of 10{sup 3} in the hard x-ray region, which makes it possible to image soft tissue and small density variations. If a sufficiently coherent x-ray beam, such as that obtained from a third generation synchrotron, is used, phase contrast can be obtained by simply moving the detector downstream of the imaged object. This setup is known as in-line or propagation based phase contrast imaging. A quantitative relationship exists between the phase shift induced by the object and the recorded intensity and inversion of this relationship is called phase retrieval. Since the phase shift is proportional to projections through the three-dimensional refractive index distribution in the object, once the phase is retrieved, the refractive index can be reconstructed by using the phase as input to a tomographic reconstruction algorithm. A comparison between four phase retrieval algorithms is presented. The algorithms are based on the transport of intensity equation (TIE), transport of intensity equation for weak absorption, the contrast transfer function (CTF), and a mixed approach between the CTF and TIE, respectively. The compared methods all rely on linearization of the relationship between phase shift and recorded intensity to yield fast phase retrieval algorithms. The phase retrieval algorithms are compared using both simulated and experimental data, acquired at the European Synchrotron Radiation Facility third generation synchrotron light source. The algorithms are evaluated in terms of two different reconstruction error metrics. While being slightly less computationally effective, the mixed approach shows the best performance in terms of the chosen criteria.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simultaneous dynamic electrical and structural measurements of functional materials

A new materials characterization system developed at the XMaS beamline, located at the European Synchrotron Radiation Facility in France, is presented. We show that this new capability allows to measure the atomic structural evolution (crystallography) of piezoelectric materials whilst simultaneously measuring the overall strain characteristics and electrical response to dynamically (ac) applied external stimuli.

36 MATERIALS SCIENCE↗

The simultaneous measurement of energy and linear polarization of the scattered radiation in resonant inelastic soft x-ray scattering

Resonant Inelastic X-ray Scattering (RIXS) in the soft x-ray range is an element-specific energy-loss spectroscopy used to probe the electronic and magnetic excitations in strongly correlated solids. In the recent years, RIXS has been progressing very quickly in terms of energy resolution and understanding of the experimental results, but the interpretation of spectra could further improve, sometimes decisively, from a full knowledge of the polarization of incident and scattered photons. Here we present the first implementation, in a high resolution soft-RIXS spectrometer used to analyze the scattered radiation, of a device allowing the measurement of the degree of linear polarization. The system, based on a graded W/B{sub 4}C multilayer mirror installed in proximity of the CCD detector, has been installed on the AXES spectrometer at the ESRF (European Synchrotron Radiation Facility); it has been fully characterized and it has been used for a demonstration experiment at the Cu L{sub 3} edge on a high-T{sub c} superconducting cuprate. The loss in efficiency suffered by the spectrometer equipped with this test facility was a factor 17.5. We propose also a more advanced version, suitable for a routine use on the next generation of RIXS spectrometers and with an overall efficiency up to 10%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a Ge-microstrip imaging detector and polarimeter

Using 98% linearly polarized radiation at the European Synchrotron Radiation Facility in Grenoble, the performance of a prototype two-dimensional microstrip Ge(i) detector for x-ray imaging and as a Compton polarimeter has been evaluated. Using the energy and position sensitivity of the detector, the ability to obtain a complete reconstruction of the Compton event has been demonstrated. The modulation coefficient of the polarimeter is in good agreement with the theoretical limit of a perfect detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional imaging of copper pillars using x-ray tomography within a scanning electron microscope: A simulation study based on synchrotron data

While microelectronic devices are frequently characterized with surface-sensitive techniques having nanometer resolution, interconnections used in 3D integration require 3D imaging with high penetration depth and deep sub-micrometer spatial resolution. X-ray tomography is well adapted to this situation. In this context, the purpose of this study is to assess a versatile and turn-key tomographic system allowing for 3D x-ray nanotomography of copper pillars. The tomography tool uses the thin electron beam of a scanning electron microscope (SEM) to provoke x-ray emission from specific metallic targets. Then, radiographs are recorded while the sample rotates in a conventional cone beam tomography scheme that ends up with 3D reconstructions of the pillar. Starting from copper pillars data, collected at the European Synchrotron Radiation Facility, we build a 3D numerical model of a copper pillar, paying particular attention to intermetallics. This model is then used to simulate physical radiographs of the pillar using the geometry of the SEM-hosted x-ray tomography system. Eventually, data are reconstructed and it is shown that the system makes it possible the quantification of 3D intermetallics volume in copper pillars. The paper also includes a prospective discussion about resolution issues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

APS/ESRF/SPring-8 2008 three-way meeting.

To foster scientific collaborations among the Advanced Photon Source (APS), the European Synchrotron Radiation Facility (ESRF), and the Super Photon Ring-8 GeV (SPring-8), the three facilities meet on a regular basis to hold technical discussions on accelerator and beamline topics and management and operational issues of common interest. The 2008 Three-Way Meeting (3WM) was held on March 18-19 at the APS with more than 20 representatives from each facility. Satellite workshops were also held on the topics of X-ray Optics, Nanoscience with X-rays, User Services, and Accelerator R&D. The 3WM and satellite workshops served as platforms for presentations and discussions of new and exciting developments at the three synchrotron sources.

43 PARTICLE ACCELERATORS↗

BioSAXS Sample Changer: a robotic sample changer for rapid and reliable high-throughput X-ray solution scattering experiments

A robotic sample changer for solution X-ray scattering experiments optimized for speed and to use the minimum amount of material has been developed. This system is now in routine use at three high-brilliance European synchrotron sites, each capable of several hundred measurements per day. Small-angle X-ray scattering (SAXS) of macromolecules in solution is in increasing demand by an ever more diverse research community, both academic and industrial. To better serve user needs, and to allow automated and high-throughput operation, a sample changer (BioSAXS Sample Changer) that is able to perform unattended measurements of up to several hundred samples per day has been developed. The Sample Changer is able to handle and expose sample volumes of down to 5 µl with a measurement/cleaning cycle of under 1 min. The samples are stored in standard 96-well plates and the data are collected in a vacuum-mounted capillary with automated positioning of the solution in the X-ray beam. Fast and efficient capillary cleaning avoids cross-contamination and ensures reproducibility of the measurements. Independent temperature control for the well storage and for the measurement capillary allows the samples to be kept cool while still collecting data at physiological temperatures. The Sample Changer has been installed at three major third-generation synchrotrons: on the BM29 beamline at the European Synchrotron Radiation Facility (ESRF), the P12 beamline at the PETRA-III synchrotron (EMBL@PETRA-III) and the I22/B21 beamlines at Diamond Light Source, with the latter being the first commercial unit supplied by Bruker ASC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of multilayer-reflected beam profiles and their coherence properties using beamlines ID19 (ESRF) and 32-ID (APS)

The use of multilayer mirrors is an interesting alternative for reflective X-ray monochromatization with respect to reflection from crystal optics. The increased photon flux density due to the multilayers' larger bandwidth is of crucial importance for, e.g, full-field X-ray imaging applications. Drawbacks are the introduced modifications of the reflected beam profile as well as a certain loss of coherence, summarized as wavefront degradation. Our recent work has shown that the modification of the beam profile can vary with, e.g., the material composition of the coating applied. In order to verify our findings, a beamline round-robin has been initiated, comparing the wavefront profiles after reflection by selected multilayers at beamlines 32-ID (Advanced Photon Source) and ID19 (European Synchrotron Radiation Facility) with our initial results acquired at BM05 (ESRF) [1].

43 PARTICLE ACCELERATORS↗

Synchrotron Radiation in Analysis of Structural Transformations Under Friction Conditions of Carbon Steel

The paper presents results of the structural transformations in the surface of carbon steel specimens during the first tens of cycles of the friction loading with a hard-alloy indenter. The widespread type AISI 1020 carbon steel is used in the experiments which are carried out on the Microfocus Beamline ID13 of the European Synchrotron Radiation Facility. The experimental setup is designed to record the diffraction patterns during the friction. It is shown that at the initial stage of friction, the diffraction maxima significantly broaden due to the defect accumulation in the crystal lattice and, as a consequence, the growth in elastic micro-distortions and the size reduction of the coherent scattering areas. A serious increase is observed in the intensity of reflection from planes of {110} family due to the formation of the respective texture in the surface layers of steel specimens. A non-destructive method is used to detect the diffraction patterns both for non-moving and moving specimens.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗