Search NASA⌕ Search

SEARCH · Search NASA

Results for “EV fires”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Electric Vehicle Fire Primer for Fleet Managers

The U.S. Department of Energy's Vehicle Technologies Office provides project assistance through Clean Cities, technical expertise, and funding to help stake-holders implement alternative fuels and electric vehicles (EVs). Fleet managers considering EVs can learn about the potential for EV fires and measures to help reduce fire risk.

ADVANCED PROPULSION SYSTEMS↗

Thermal Damage Potential of Electric Vehicles

The main objective is to assess the risk that electric vehicle (EV) battery fires pose regarding thermal damage to other vehicles involved in a crash and to compare EV and internal combustion engine vehicle (ICEV) fires. A literature review of experimental data and statistics are used to perform the assessment. The findings indicate: (1) the heat flux emitted from an EV and ICEV fire are similar due to cabin materials being the main contributor to heat flux, (2) for ICEVs involved in a crash with fuel tank leakage, the thermal damage is significantly more than from an EV fire for equivalent fire durations, (3) the thermal damage potential from ICEV pool fires is at least 5 times higher than EV fires, and (4) EV and ICEV crashes resulting in a fire is about 0.002% and 0.2%, respectively. Thus, EV battery fires have a lower risk than ICEV fires.

33 ADVANCED PROPULSION SYSTEMS↗

Navigating Common Electric Vehicle and Charging Infrastructure Concerns

Increasing knowledge about electric vehicles (EVs) can increase Tribal member comfort level with the technology, leading to increased EV adoption. This fact sheet lists common EV and charging infrastructure concerns and provides information to help address these hurdles during engagement with Tribal communities.

33 ADVANCED PROPULSION SYSTEMS↗

Defining the State of Safety (SOS) for Lithium-Ion Batteries in EVs: A Discussion

The demand for lithium-ion batteries (LIBs) is skyrocketing, driven by the rapid growth of electric vehicles (EVs) and grid energy storage. However, current LIBs rely on flammable electrolytes, making them susceptible to thermal runaway and fires. Despite ongoing research and development efforts to enhance safety, fire incidents in EVs and energy storage systems persist. As LIB deployment increases, so too does the risk of fires. Therefore, it's crucial to define a "State of Safety" for LIBs - encompassing both operational safety and post-incident safety, such as after a car accident. This concept can help stakeholder and first responders to effectively manage LIB fire risks.

25 ENERGY STORAGE↗

National Fire Protection Association Spurs the Safe Adoption of EVs Through Education and Outreach

As electric vehicles (EV) and their charging infrastructure steadily increase in popularity across the U.S., growing pains still exist, impeding their true potential for growth. The barriers include a general lack of knowledge around EV systems, range anxiety, electrical workplace safety practices, code compliance and inspection for charging stations, maintenance garages and workers, insurance concerns, and the potential risks associated with damaged lithium-ion batteries (fires, re-ignition, water immersion, and stranded energy).NFPA partnered with SMEs, training development organizations, and Clean City Coalitions to create a series of common online trainings for each EV ecosystem sector, educating communities on the realities of EV proliferation, myths, facts, statistics, codes, and basic information for each sector to become versed in EV knowledge. We also constructed a workshop program for the many EV stakeholders who should be involved in setting up a strategic, cohesive outlook for the participating towns and cities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Safe Response to Renewable Energy Hazards

The International Association of Fire Fighters (IAFF) and Underwriters Laboratories, LLC (UL) in conjunction with UL Solutions initiated a joint project in 2022 under an agreement with the United States Department of Energy-Office of Energy Efficiency and Renewable Energy (DOE-EERE). This project focused on two separate and important initiatives related to energy efficiency in residential buildings. Initiative 1: Fire Performance on Energy Efficient Exterior Walls. Initiative 2: Firefighting Tactics in Residential Properties with Building Energy Storage Systems (BESS). The project’s first initiative addresses concerns surrounding new technologies with enhanced, energy-efficient exterior walls installed on residential properties. The concerns of fire rapidly traveling vertically up the exterior of these walls were examined. This addressed a growing concern from the first responder community that many times, the fires on the exterior of residential buildings have already evolved into an attic fire by the time of arrival – making it problematic to address the fire scenario. The test plan for Initiative 1 incorporated a modified version of an American Society for Testing and Materials (ASTM) test method, ASTM E2707, Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure, as the foundation of the research. The test method involved a wall structure intended to represent retrofit construction to evaluate how fire would spread vertically or laterally. The second aspect of the UL-IAFF Project focuses on the fire service response to Residential Battery Energy Storage System (RBESS) incidents. These simulation tests were constructed in the large-scale fire test facility at UL Solutions’ Northbrook, IL campus. A baseline test was conducted that involved a test structure with no batteries—shelving units populated with standardized commodities, representing a typical garage with cellulosic and plastic contents. Three additional tests have been conducted to generate data with the contribution of energy storage system (ESS) batteries to compare fire and explosion hazards against the baseline test. Through this work, fire service tactical considerations can be explored. From the data, the team can determine 1) the visual indicators of a residential fire that has involved an RBESS (or, potentially, other large batteries) and 2) the impact of fire service-initiated ventilation of the structure on the fire conditions and explosion risks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Large Local Currents in a Lithium-Ion Battery during Rest after Fast Charging

Increasing electric vehicle (EV) adoption requires lithium-ion batteries that can be charged quickly and safely. Some EV batteries have caught on fire despite being neither charged nor discharged. While the lithium that plates on graphite during fast charging affects battery safety, so do the internal ionic currents that can occur when the battery is at rest after charging. These currents are difficult to quantify; the external current that can readily be measured is zero. Here we study a graphite electrode at rest after 6C fast charging using operando X-ray microtomography. We quantify spatially resolved current density distributions that originate at plated lithium and end in underlithiated graphite particles. The average current densities decrease from 1.5 to 0.5 mA cm -2 in about 20 min after charging is stopped. Surprisingly, the range of the stripping current density is independent of time, with outliers above 20 mA cm -2 . In conclusion, the persistence of outliers provides a clue as to the origin of catastrophic failure in batteries at rest.

25 ENERGY STORAGE↗

Degradation and Accelerated Recovery of Surface Passivation in n+ Poly-Si/SiOx Passivating Contacts for TOPCon Solar Cells

We studied the surface degradation and recovery of fired poly-Si/SiOx passivating contacts during subsequent dark and illuminated annealing. We report on an industrially-viable path for accelerated recovery of surface passivation. The degradation is influenced by the type of doping in the poly-Si. Phosphorus doped n+ poly-Si/SiOx contacts show degradation followed by recovery, undoped poly-Si/SiOx contacts only show recovery during annealing. Boron doped p+ poly-Si/SiOx contacts show neither degradation nor improvement with annealing. Both degradation and recovery are thermally-activated processes and are completely reversible and cyclic in nature. The activation energy of degradation and recovery in dark for n+ poly-Si/SiOx contacts are 1.27 and 1.33 eV respectively. Dark annealing at elevated temperatures is effective for complete recovery but takes a long time (~30 min at 350 degrees C) due to higher activation energies. Annealing under 7.5 Suns of illumination lowers the activation energy for degradation and recovery to 0.88 and 0.90 eV, respectively. Using this data, we have developed an industrially viable post-firing treatment for accelerated recovery of TOPCon cells by annealing them at elevated temperatures and under intense illumination for a few minutes.

14 SOLAR ENERGY↗

NFPA Distributed Energy Resources Safety Training (DERST) For Emergency Responders

The National Fire Protection Association, with support from the Department of Energy, executed a multi-year initiative to develop, enhance, and disseminate Distributed Energy Resources Safety Training (DERST) tools for U.S. emergency responders. As Distributed Energy Resources (DER)—such as solar photovoltaics, battery energy storage systems (ESS), electric vehicles (EVs), and associated infrastructure—become increasingly prevalent, the NFPA identified a critical need for up-to-date standardized, accessible, and effective safety training tailored for the fire service and related public safety professionals. The project delivered a comprehensive suite of educational resources to improve responders’ abilities to safely manage DER-related incidents. This included: • Revised Modular Training Courses: Updated classroom-based DER safety courses, now modular and accessible nationwide through fire academies and the North American Fire Training Directors (NAFTD) network. • Live Burn Testing & Research: A full-scale controlled burn of a DER-equipped residential structure provided real-world data and insights, forming the basis for updated best practices. • A Gamified Simulation Tool – Firefighters Incident Response Simulation Tool (FIRST): A first-of-its-kind, multiplayer, scenario-based simulation using the Unreal Engine 5.0 to train responders in a realistic virtual, multi-DER incident environment. • Field Familiarization Software Tools & Prop Guide: Digital DER field familiarization evolutions software guide and a prop development manual to support field-based DER training exercises, enhancing responders' hands-on familiarity with DER infrastructure and collaboration on virtual incident responses. • National Dissemination Strategy: Strategic partnerships with NAFTD, Vector Solutions, and others enabled wide-scale distribution, with over 5,000 departments accessing resources and 1,100+ departments adopting the simulator in the first seven months. Also provided a web portal for easy access to all training and simulation programs developed under this grant for the U.S. responder community. Key findings from the project—particularly from the burn test—led to paradigm shifts in fire response tactics. For example, traditional approaches to garage fires may be hazardous if DERs are present, due to explosive off gassing and thermal runaway risks. The new training emphasizes scene assessment, stand-off approaches, thermal imaging verification, and careful post-incident cooling of DER components to prevent reignition. This initiative has had a significant national impact, raising awareness, enhancing preparedness, and supporting safer DER incident response practices. Significant engagement from the media, public safety organizations, and PBS coverage has further amplified the reach and adoption of NFPA’s DER safety training, tools, and simulations.

14 SOLAR ENERGY↗

EV-EVSE Fault Study: An Analysis of Thermal Events Caused by Electrical Faults during DC Charging

This report outlines multiple avenues of analysis of electrical faults associated with electric vehicles (EVs) during charging, focusing specifically on the interactions between EVs and EV supply equipment (EVSE). Key concerns include the identification and mitigation of overtemperature events that can result in fires, which are commonly initiated by localized heating of connectors, wiring, or high-impedance fault current paths.

42 - ENGINEERING↗

Surface enhanced performance of La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3-δ cathodes by infiltration Pr-Ni-Mn-O progress

Herein the present study reports the enhancement of electrochemical oxygen reduction activity of porous La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3–δ (LSCF) cathodes by coating a thin film of Pr-Ni-Mn oxide (PNM5) using a multi-step infiltration process. XRD examination reveals that PNM5 mainly contains a multiphase mixture of Pr 6 O 11 , PrNiO 3 , MnO and NiO. SEM morphology shows a thin PNM5 film and small particles are formed on the surface of LSCF backbone particles. Impedance spectrum analysis indicates that PNM5 infiltrated LSCF exhibits dramatically reduced polarization resistance (R p ), reaching R p of 0.244 Ω cm 2 at 973 K, which is one-half of the baseline LSCF cathode. The activation energy of LSCF cathodes infiltrated with PNM5 is 1.45 eV, slightly lower than the baseline LSCF cathode (1.77 eV). Distribution of relaxation time (DRT) function analysis shows PNM5 infiltration layer significantly promotes the oxygen reduction reaction (ORR) of cathode surface. With the increase in firing temperature, the total resistance increases and R p changes from ion transport to oxygen reduction reaction. Degradation rate of the PNM5-infiltrated LSCF is also lower, 0.02168% vs 0.07093% for the baseline LSCF over a 200-h period. A single cell testing indicated that the peak power density of the PNM5-infiltrated cell was increased by 140.66%. Overall, PNM5 could be a potential catalyst for boosting the performance of a commercial LSCF cathode for solid oxide fuel cells (SOFC).

36 MATERIALS SCIENCE↗

Electric Vehicle Charging Data Falsification Attacks Utilizing Behavioral Models

A charging station (CS) and its associated electric vehicle supply equipment (EVSE) and charging electric vehicle (EV) interactions are potential targets for data falsification attacks since CSs are typically unmanned public facilities that are connected to the internet and EVs incorporate the vulnerable CAN bus network, which are both susceptible to remote attacks. The research question being addressed is how is the EV owner and CS negatively affected by CAN bus EV battery current sensor and battery temperature sensor data falsification attacks. Negative effects include economic losses from reduced life span of the battery, battery thermal runaway and fire (and potential loss of surrounding structure), and reduced utilization of the CS due to delayed departure time (longer charging times).

25 ENERGY STORAGE↗

Role of Electric Vehicles in the U.S. Power Sector Transition: A System-Level Perspective

After over a century of petroleum dominance many anticipate that electrification could disrupt the transportation energy landscape. At the same time, the electric power systems are undergoing profound changes: variable renewables are displacing conventional generation sources; distributed generation is disrupting utility business models; energy storage and other new technologies are emerging; and the traditional system based on the premise that generation is dispatched to match an inelastic demand is evolving to create a system with greater participation in power system planning and operations from traditionally passive consumers. In this context, it is important to understand how transportation electrification will impact electricity demand and in turn electricity supply, including changes in the load shapes that characterize the system and the opportunity to leverage flexible electric vehicle (EV) charging to better integrate demand and supply. Assessing the impacts of electrification on the energy system requires an understanding of how it might impact the amount and shape of electricity consumption, and how this electricity can be supplied. In particular, increased adoption of electric vehicles introduces a new source of demand altogether, potentially very flexible. Moreover, electrification could shift the consumption of natural gas between sectors, thereby affecting the economics for natural gas-fired generation relative to other electricity generation options. Several factors will impact the evolution of the power system under a widespread electrified future, which, in turn, could have far-reaching effects on future energy costs and emissions.

47 OTHER INSTRUMENTATION↗

Fire Protection Engineering Technical Report for Electric Vehicles and Lithium-Ion Batteries

This fire protection engineering technical report discusses and presents the properties, data, and safety of select lithium-ion batteries. Lithium-ion batteries have increased in usage and a fire scenario analysis must be created for each situation where they may be introduced in buildings to determine the risk associated if a battery failure were to occur.

25 ENERGY STORAGE↗

Degradation and Accelerated Recovery of Surface Passivation in n+, p+, and Intrinsic Poly-Si/SiOx Passivating Contacts for Silicon Solar Cells

We report on the degradation and recovery of surface passivation of fired poly-Si/SiOx passivating contacts with hydrogen containing Al2O3 during annealing in the dark and under illumination. Upon firing to a peak temperature of 670 degrees C, the iVoc for symmetric test structures with n+, p+, and intrinsic poly-Si/SiOx contacts decreases due to a loss of surface passivation. Upon further annealing over the temperature range of 200-350 degrees C in the dark, depending on the type of doping, the surface passivation either shows further degradation followed by recovery, or direct recovery to the initial iVoc. Annealing at higher temperatures and/or higher illumination intensities accelerates the kinetics for both degradation and recovery processes. We show that the degradation and recovery processes are thermally activated and proceed identically in subsequent firing and annealing steps showing their cyclic nature. We present a series reaction model to explain the kinetics of degradation and recovery processes for n+ and intrinsic poly-Si/SiOx contacts. By fitting the model's rate expressions to the data, the determined effective activation energy barriers for degradation and recovery for n+ poly-Si/SiOx contacts in the dark are 1.24 and 1.51 eV, which are lowered under 7.5 Suns illumination to 0.76 and 1.15 eV, respectively.

14 SOLAR ENERGY↗

Battery Energy Storage Systems: A Review of Energy Management Systems and Health Metrics

With increasing concerns about climate change, there is a transition from high-carbon-emitting fuels to green energy resources in various applications including household, commercial, transportation, and electric grid applications. Even though renewable energy resources are receiving traction for being carbon-neutral, their availability is intermittent. To address this issue to achieve extensive application, the integration of energy storage systems in conjunction with these resources is becoming a recommended practice. Additionally, in the transportation sector, the increased demand for EVs requires the development of energy storage systems that can deliver energy for rigorous driving cycles, with lithium-ion-based batteries emerging as the superior choice for energy storage due to their high power and energy densities, length of their life cycle, low self-discharge rates, and reasonable cost. As a result, battery energy storage systems (BESSs) are becoming a primary energy storage system. The high-performance demand on these BESS can have severe negative effects on their internal operations such as heating and catching on fire when operating in overcharge or undercharge states. Reduced efficiency and poor charge storage result in the battery operating at higher temperatures. To mitigate early battery degradation, battery management systems (BMSs) have been devised to enhance battery life and ensure normal operation under safe operating conditions. Some BMSs are capable of determining precise state estimations to ensure safe battery operation and reduce hazards. Precise estimation of battery health is computed by evaluating several metrics and is a central factor in effective battery management systems. In this scenario, the accurate estimation of the health indicators (HIs) of the battery becomes even more important within the framework of a BMS. This paper provides a comprehensive review and discussion of battery management systems and different health indicators for BESSs, with suitable classification based on key characteristics.

Nazaralizadeh, Solmaz (ORCID:0009000737004039)↗

Detecting Short Circuits: Post Accident Electric Vehicle Battery Safety Check

Fast and accurate detection of soft short circuits (SCs) in the battery packs of damaged electric vehicles is needed by first responders and mechanics to mitigate the potential risk from battery fires that may occur hours, days, or weeks after an accident. Here, this paper presents an SC-detection algorithm for potentially damaged lithium-ion batteries that works quickly and without a priori knowledge of the battery-pack chemistry, capacity, state of charge, or state of health. The proposed universal SC-detection algorithm is designed to be implemented on an inexpensive handheld device that can connect to and monitor the voltages of all cells in a pack. Transient filtering and linear-quadratic state observation provide estimates of normalized SC current for every cell in the pack. Cells with SC-current estimates outside a sigma-based threshold are detected. Simulations, experiments, and electric vehicle (EV) crash data are used to verify the speed, sensitivity, and accuracy of the method, demonstrating 96% accurate detection of 0.0027 C SCs in under 1 h for 5S cell groups in the lab and no false positives for crashed Volkswagen, Chevrolet, and Tesla vehicles without SCs.

25 - ENERGY STORAGE↗

Demand Response in Residential Energy Code: Technical Brief

As buildings account for over 75% of U.S. electricity use, effectively managing their loads can greatly facilitate the transition towards a clean, reliable grid. Grid-interactive efficient buildings (GEBs) combine efficiency and demand flexibility with smart technologies and communication to provide occupant comfort and productivity while serving the grid as a distributed energy resource (DER). In turn, GEBs can play a key role in ensuring access to an affordable, reliable, sustainable, and modern U.S. electric power system. Their national adoption could provide $\$$100-200 billion in U.S. electric power system cost savings over the next two decades. The associated reduction in CO 2 emissions is estimated at 6% per year by 2030 (DOE 2021). Building codes represent standard design practice in the construction industry and continually evolve to include advanced technologies and innovative practices. Historically, national model energy codes establish minimum efficiency requirements for new construction (ICC 2020). Expanding codes to support GEB capabilities is a pivotal step towards realizing demand flexibility in support of a clean grid by addressing capabilities to improve interoperability between smart building systems, the grid, and renewable energy resources. Realizing GEBs requires buildings with automated demand response (DR) capabilities that enable standardized communication with or control of, subject to explicit consumer consent, energy smart appliances or home energy management systems. This is achieved through direct or indirect (i.e., via an aggregator) communication between appliances and the electric grid. Energy codes can also support DR communication standardization and advance the deployment of building-integrated DERs such as energy storage, generation, and electric vehicles (EVs). Incorporating automated DR capabilities in energy codes provides many benefits to the consumers. Specifically, it aligns building electric load demand with intermittent renewable energy source availability, decreases peak load on the electric grid, allows buildings to respond to utility price signals, supports electrical network reliability and market growth of products and processes aligned with clean economic growth. The incorporation of DR into the model residential energy codes was considered for both the 2021 and 2024 International Energy Conservation Code (IECC) code development cycles. The approved DR measures in the 2021 cycle were removed in response to appeals (ICC 2020). Updated language was presented for consideration again for the 2024 IECC, where it was negotiated and again approved, and again removed in response to appeals (ICC 2024). This resulted in many sections, including sections on demand responsive controls, being moved to the credits options or an appendix as a voluntary application. This technical brief updates the proposed DR components such that they can be considered by states and local governments for direct incorporation into their codes, as well as for future IECC energy code development. The proposal refinements are intended to support consistency in approach and provide a degree of certainty for building owners, designers, contractors, manufacturers, and building and fire safety professionals. The scope of this technical brief includes three strategies for DR in residential buildings: 1) smart thermostats with demand-responsive control, 2) electric water heating incorporating demand-responsive controls and communication and 3) grid Integrated solar and energy storage systems.

2021 IECC↗