Search NASA⌕ Search

SEARCH · Search NASA

Results for “EV grid impacts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Analysis of Electrical Grid Capacity by Interconnection for Urban Air Mobility

A wide range of challenges must be overcome to conduct Urban Air Mobility (UAM)operations at scale with electric vertical take-off and landing aircraft as envisioned. This paper documents an analysis of one potential infrastructure challenge for UAM: available electrical grid power capacity. The success of UAM depends on the availability of electricity, which will be increasingly impacted by the proliferation of ground electric vehicles(EVs) over time. Under the best-case assumption that electricity can be transmitted and distributed as needed within each interconnection (i.e., electrical grid), it is estimated that the maximum number of UAM aircraft that can charge simultaneously in the continental United States will decrease by 20% from about 595 thousand in the year 2021 to about 475 thousand in the year 2050due to the projected increase in ground EVs.

electrical grid↗

Analysis of Electrical Grid Capacity by Interconnection for Urban Air Mobility

A wide range of challenges must be overcome to conduct Urban Air Mobility (UAM)operations at scale with electric vertical take-off and landing aircraft as envisioned. This paper documents an analysis of one potential infrastructure challenge for UAM: available electrical grid power capacity. The success of UAM depends on the availability of electricity, which will be increasingly impacted by the proliferation of ground electric vehicles(EVs) over time. Under the best-case assumption that electricity can be transmitted and distributed as needed within each interconnection (i.e., electrical grid), it is estimated that the maximum number of UAM aircraft that can charge simultaneously in the continental United States will decrease by 20% from about 595 thousand in the year 2021 to about 475 thousand in the year 2050due to the projected increase in ground EVs.

electrical grid↗

Analysis of Electrical Grid Capacity in Major U.S. Metropolitan Areas for Urban Air Mobility

A wide range of challenges must be overcome to conduct Urban Air Mobility (UAM) operations at scale with electric vertical takeoff and landing aircraft as envisioned. This paper documents an analysis of one potential infrastructure challenge for UAM: available electrical grid power capacity. The success of UAM depends on the availability of electricity, which will be increasingly impacted by the proliferation of ground electric vehicles (EVs) over time. Under the worst-case assumption that each U.S. Metropolitan Statistical Area (MSA) can only access and utilize the electricity generated by power plants within its boundaries, it is estimated that the maximum number of UAM aircraft that can charge simultaneously in the 25 most populous MSAs will decrease by about 61% from about 129,000 in the year 2021 to about 51,000 in the year 2050, due to the projected increase in ground EVs. Also, it is estimated that the number of these MSAs that may lack any available electrical grid power capacity for UAM operations will increase from zero MSAs in 2021 to eleven MSAs in 2050—including three MSAs that prospective UAM operators have announced as target markets (Los Angeles, Miami, and Orlando)—unless electricity demand for other purposes is reduced.

electrical grid↗

Analysis of Electrical Grid Capacity in Major U.S. Metropolitan Areas for Urban Air Mobility

A wide range of challenges must be overcome to conduct Urban Air Mobility (UAM) operations at scale with electric vertical takeoff and landing aircraft as envisioned. This paper documents an analysis of one potential infrastructure challenge for UAM: available electrical grid power capacity. The success of UAM depends on the availability of electricity, which will be increasingly impacted by the proliferation of ground electric vehicles (EVs) over time. Under the worst-case assumption that each U.S. Metropolitan Statistical Area (MSA) can only access and utilize the electricity generated by power plants within its boundaries, it is estimated that the maximum number of UAM aircraft that can charge simultaneously in the 25 most populous MSAs will decrease by about 61% from about 129,000 in the year 2021 to about 51,000 in the year 2050, due to the projected increase in ground EVs. Also, it is estimated that the number of these MSAs that may lack any available electrical grid power capacity for UAM operations will increase from zero MSAs in 2021 to eleven MSAs in 2050—including three MSAs that prospective UAM operators have announced as target markets (Los Angeles, Miami, and Orlando)—unless electricity demand for other purposes is reduced.

electrical grid↗

Tabulation of hybrid theory calculated e-N2 vibrational and rotational cross sections

Vibrational excitation cross sections of N2 by electron impact are tabulated. Integrated cross sections are given for transitions v yields v prime where o=or v=or 8 in the energy range 0.1 eV=or E=or 10 eV. The energy grid is chosen to be most dense in the resonance region (2 to 4 eV) so that the substructure is present in the numerical results. Coefficients in the angular distribution formula (differential scattering cross section) for transitions v=0 yields v prime = or 8 are also numerically given over the same grid of energies. Simultaneous rotation-vibration coefficients are also given for transitions v=o,j=o; 1 yields v prime=o, j=o,2,4; 1,3,5. All results are obtained from the hybrid theory.

Chandra, N.↗

Generating Hyperthermal Atomic Oxygen

Atomic oxygen diffused through silver desorbed by low-energy electron impact. Oxygen atoms diffuse through silver foil and emerge on high-vacuum side, aided by electron-stimulated desorption. Atomic-oxygen flux levels range up to 10 to the 12th power cm to the negative 2 power S to the negative 1 power, and kinetic energies range from 1 to 10 eV. O positive and O negative ions swept aside by charged cylindrical grids.

Outlaw, Ronald A.↗

Buffer Layer Effects on Tandem InGaAs TPV Devices

Single junction indium gallium arsenide (InGaAs) based TPV devices have demonstrated efficiencies in excess of 20% at radiator temperatures of 1058 C. Modeling suggests that efficiency improvements in single bandgap devices should continue although they will eventually plateau. One approach for extending efficiencies beyond the single bandgap limit is to follow the technique taken in the solar cell field, namely tandem TPV cells. Tandem photovoltaic devices are traditionally composed of cells of decreasing bandgap, connected electrically and optically in series. The incident light impinges upon the highest bandgap first. This device acts as a sieve, absorbing the high-energy photons, while allowing the remainder to pass through to the underlying cell(s), and so on. Tandem devices reduce the energy lost to overexcitation as well as reducing the current density (Jsc). Reduced Jsc results in lower resistive losses and enables the use of thinner and lower doped lateral current conducting layers as well as a higher pitch grid design. Fabricating TPV tandem devices utilizing InGaAs for all of the component cells in a two cell tandem necessitates the inclusion of a buffer layer in-between the high bandgap device (In0.53 Ga0.47As - 0.74eV) and the low bandgap device (In0.66Ga0.34As - 0.63eV) to accommodate the approximately 1% lattice strain generated due to the change in InGaAs composition. To incorporate only a single buffer layer structure, we have investigated the use of the indium phosphide (InP) substrate as a superstrate. Thus the high-bandgap, lattice- matched device is deposited first, followed by the buffer structure and the low-bandgap cell. The near perfect transparency of the high bandgap (1.35eV) iron-doped InP permits the device to be oriented such that the light enters through the substrate. In this paper we examine the impact of the buffer layer on the underlying lattice-matched InGaAs device. 0.74eV InGaAs devices were produced in a variety of configurations both with and without buffer layers. All structures were characterized by reciprocal space x-ray diffraction to determine epilayer composition and residual strain. Electrical characterization of the devices was performed to examine the effect of the buffer on the device performance. The effect of the buffer structure depends upon where it is positioned. When near the emitter region, a 2.6x increase in dark current was measured, whereas no change in dark current was observed when it was near the base region.

Wilt, David M.↗