Search NASA⌕ Search

SEARCH · Search NASA

Results for “EXHAUST SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Tests of a High Temperature Sample Conditioner for the Waste Treatment Plant LV-S2, LV S3, HV S3A and HV-S3B Exhaust Systems

Tests were performed to evaluate a sample conditioning unit for stack monitoring at Hanford Tank Waste Treatment and Immobilization Plant (WTP) exhaust stacks with elevated air temperatures. The LV-S2, LV-S3, HV-S3A and HV-S3B exhaust stacks are expected to have elevated air temperature and dew point. At these emission points, exhaust temperatures are too high to deliver the air sample directly to the required stack monitoring equipment. As a result, a sample conditioning system is considered to cool and dry the air prior to its delivery to the stack monitoring system. The method proposed for the sample conditioning is a dilution system that will introduce cooler, dry air to the air sample stream. This method of sample conditioning is meant to reduce the sample temperature while avoiding condensation of moisture in the sample stream. An additional constraint is that the ANSI/HPS N13.1-1999 standard states that at least 50% of the 10 µm aerodynamic diameter (AD) particles present in the stack free stream must be delivered to the sample collector. In other words, depositional loss of particles should be limited to 50% in the sampling, transport, and conditioning systems. Based on estimates of particle penetration through the LV-S3 sampling system, the diluter should perform with about 80% penetration or better to ensure that the total sampling system passes the 50% or greater penetration criterion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Passive and no-loss weather cap for protection of wind induced downdraft in sensitive exhaust systems

The invention provides a device for removing heat from a building, the device having: a first tubular member defining a first cavity; a second tubular member defining a second cavity, whereby said second tubular member resides within the first cavity and is coaxial to the first tubular member; and a double conic body coaxially residing in the first cavity and coaxially positioned with the second tubular member.Also provided is a method for removing heat from a building, the method having the steps of: directing heat-containing exhaust emanating from a flue, defining a first diameter, to a passageway received by the flue, whereby the passageway defines a longitudinal axis and a periphery circumscribing the axis; forming the directed exhaust into a slipstream, wherein the slipstream generally travels along the longitudinal axis; and routing precipitation entering the passageway to the periphery.

Lisowski, Darius D.↗

Passive and no-loss weather cap for protection of wind induced downdraft in sensitive exhaust system

The invention provides a device for removing heat from a building, the device having: a first tubular member defining a first cavity; a second tubular member defining a second cavity, whereby said second tubular member resides within the first cavity and is coaxial to the first tubular member; a double conic body coaxially residing in the first cavity and coaxially positioned with the second tubular member; and a flange dimensioned to extend over at least a portion of the periphery of the existing flue so as to aid in supporting the device on the flue.

Lisowski, Darius D.↗

Diagnostic methods for a high efficiency exhaust aftertreatment system

A method includes acquiring nitrogen oxide (NOx) data indicative of a first amount of NOx in an exhaust flow exiting an engine and a second amount of NOx in the exhaust flow exiting an exhaust aftertreatment system coupled to the engine where the exhaust aftertreatment system including a selective catalytic reduction (SCR) system including a SCR catalyst; determining a NOx conversion efficiency fault is present within the exhaust aftertreatment system based on the first amount of NOx and the second amount of NOx; monitoring an actual amount of NOx in the exhaust flow downstream of the SCR catalyst; determining an expected amount of NOx downstream of the SCR catalyst; and determining the SCR catalyst is responsible for the NOx conversion efficiency fault in response to the actual amount of NOx differing from the expected amount of NOx by more than a threshold amount.

Gupta, Aniket↗

Diagnostic methods for a high efficiency exhaust aftertreatment system

A method includes interpreting NOx data indicative of an amount of NOx exiting an engine and an amount of NOx exiting an exhaust aftertreatment system coupled to the engine, determining a NOx conversion efficiency fault is present based on the amount of NOx exiting the engine and the amount of NOx exiting the exhaust aftertreatment system, and determining at least one of a selective catalytic reduction (SCR) catalyst of the exhaust aftertreatment system and a diesel particulate filter having a coating of a SCR reaction catalyst (DPF-SCR) of the exhaust aftertreatment system are responsible for the NOx conversion efficiency fault based on at least one of a reductant slip amount and a NOx conversion value across at least one of the SCR catalyst and the DPF-SCR.

42 ENGINEERING↗

Evaluation of FTWC Vent System

A monitored exhaust system has been designed for use in venting the Flanged Tritium Waste Containers (FTWCs) at LANL. This system will provide controlled exhaust and emissions monitoring for the FTWCs, and also provide general area exhaust around the venting operations to measure any emissions which may bypass the primary vent system. A full description of the process and need for the system is described in the Pre-Construction Application for this project. This document describes the commissioning testing performed on the FTWC vent system to prepare it for use. The system has been tested and shown to meet ANSI standard requirements and is fully suitable for use.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WIPP Safety Significant Confinement Ventilation System (SSCVS) HEPA Filtration System - 20165

Construction and major equipment fabrication are underway for a new ventilation exhaust system at the Waste Isolation Pilot Plant (WIPP). The new system will provide continuous High Efficiency Particulate Air (HEPA) filtration of the exhaust from the WIPP underground while meeting the ventilation demands for expanded waste emplacement and mining operations over the next 40 years. The integrated system design provides for reducing the salt, clay and diesel particulates from the exhaust airflow from the mine, prior to full filtration using Nuclear Safety Significant HEPA filters. The SSCVS design and equipment provides for continuous HEPA filtration over a wide range of operating and environmental conditions. The new exhaust system connects to the existing underground exhaust shaft, and the exhaust air flows from the underground through Salt Reduction Units (SRUs) to protect the final filter banks from excessive moisture and rapid salt/dust buildup. Each of the six (6) SRUs consists of a demister to remove entrained moisture, a dry salt remover unit to filter approximately 90% of the entrained salt/dust, and an automated water treatment system to periodically clean the demisters and to remove salt from the SRU filters. At the maximum expected exhaust flowrate of 540,000 Cubic Feet per Minute (CFM) / 255 Cubic Meters per Second (m{sup 3}/s), five (5) salt removal units will be in operation with one unit in standby or maintenance. An in-line variable frequency drive booster fan will offset pressure losses through each SRU and reduce the relative humidity of the air exiting the SRUs. In the event of a high radiation alarm from the underground Continuous Air Monitors (CAMs), the SRUs will be automatically bypassed, which places the SRS and building outside of the Safety Significant confinement boundary. From the SRUs, the exhaust is directed to the HEPA filter banks located in the New Filter Building. The exhaust system is designed to provide continuous HEPA filtration prior to release to the exhaust stack. There are 22 HEPA filter banks rated at 27,000 CFM / 12.75 m{sup 3}/s each. Each filter bank has two stages of pre-filters and two stages of HEPA filters. The filtered air from each of the 22 filter banks discharges into a common concrete plenum, which is maintained under a negative pressure by the main exhaust fans. Six 1,000 HP variable frequency drive exhaust fans are provided on the south side of the plenum. At the maximum expected exhaust flow of 540,000 CFM, four exhaust fans and twenty filter banks will be in operation. The fans discharge vertically to a separate concrete exhaust plenum. The filtered exhaust is routed from the exhaust plenum to a 125-foot-tall exhaust stack via a 13-foot diameter duct. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WIPP Safety Significant Confinement Ventilation System (SSCVS) Quality Assurance Program - 20237

Construction and major equipment fabrication are underway for a new ventilation exhaust system at the Waste Isolation Pilot Plant (WIPP). The new system will provide continuous HEPA filtration of the exhaust from the WIPP underground while meeting the ventilation demands for expanded waste emplacement and mining operations over the next 40 years. The SSCVS project has proceeded with the awarding of CD-3A for Long Lead Procurements followed by CD-2/3 approval for the construction of the facilities. The SSCVS project team made the decision to increase the quality oversight throughout the complete project per the Project Quality Assurance Plan (PQAP) such that it can ensure the final products meet applicable NQA-1 requirements and general quality requirements, and that the project will proceed to operations without significant delays due to post installation quality concerns. The PQAP was established prior to approval of the project at the CD-2/3 milestone. The SSCVS project has 2 major long lead procurements which commenced with the awarding of CD-3A. These procurements include the HEPA filter housing assemblies and the Exhaust Fans. There are 22 HEPA filter assemblies for the SSCVS, which are designated Safety Significant for pressure boundary confinement, per the approved PDSA. The exhaust fans also have Safety Significant components to maintain the pressure confinement boundary. NWP made the decision to install resident Quality Inspectors at the fabrication facilities to ensure the documentation for each fabricated unit meets all the QA requirements as defined in the respective contract documents. For the construction of the SSCVS Salt Reduction Building (SRB) and New Filter Building (NFB), dedicated, on-site quality inspectors have been utilized to ensure that all work being performed will comply with quality requirements and the Special Inspections as defined in IBC-2015. At each stage of inspection, hold points are placed into the work packages to ensure NWP QA personnel are present to inspect and verify the installations are in accordance with the design specifications, codes and standards. With this level of oversight, NWP anticipates that the level of quality related issues, as seen on multiple other DOE complex site projects, will be avoided and that the commissioning, start-up and hot operations will progress in a timely fashion, as all documentation will be in place and approved prior to initiation of these activities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Co-Optimization Scheme for Hybrid Electric Vehicles Powertrain and Exhaust Emission Control System Using Future Speed Prediction

Hybrid electric vehicles (HEVs) have been an effective solution for improved vehicle fuel efficiency and reduced emission pollution. In this paper, a co-optimization scheme is proposed to optimize fuel efficiency for HEVs. Here, the proposed optimization scheme uses obtainable future speed prediction as the basis to optimally tune control parameters for the existing powertrain control system. The ramp-up time of the catalyst temperature to reach its light-off level in the exhaust emission system is also considered as an additional optimization constraint to reduce emission. The Toyota Prius Hybrid Simulink model which is an integrated model for a powertrain and exhaust emission system is validated using real data from several real driving cycle scenarios. Then, to simplify the formulation of the proposed algorithm, the model for the optimization for powertrain and exhaust emission systems is represented by a set of equivalent neural network (NN) models learned using the data generated from the well-validated Toyota Prius Hybrid Simulink model. Using NN models, a co-optimization algorithm is established that provides an optimal tuning of some fuel-sensitive powertrain control parameters using future speed prediction, leading to a novel co-optimization algorithm, achieving on average a further 9.22% fuel savings for the Toyota Prius Hybrid Simulink model.

33 ADVANCED PROPULSION SYSTEMS↗

Protocol for Determining Actual Flow Rate in FTWC Duct Systems

This paper is intended to document the theory and methods to determine the actual flow rate in the exhaust system used to ventilate the Flanged Tritium Waste Containers based on realtime instrument readings. Section 1 provides introductory and background material; Section 2 details the various correction factors used to adjust flow readings for ambient air pressure and temperature and other operational parameters. Section 3 provides guidance on implementing this process during venting operations, and Section 4 provides supporting documentation and also a field checklist that can be used by personnel during venting. For Revision 1, a summary of editorial changes made to the paper was added as Section 4.4, as well as a section documenting peer review (Section 4.5).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Capture probe

A system for sampling a sample material includes a device for directing sample into a capture probe. A probe includes an outer probe housing having an open end. A liquid supply conduit has an outlet positioned to deliver liquid to the open end. An exhaust conduit removes liquid from the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust system can be in fluid connection with the liquid exhaust conduit for removing liquid from the liquid exhaust conduit at a second volumetric flow rate, which exceeds the first volumetric flow rate such that gas with sample is withdrawn with the liquid.

42 ENGINEERING↗

Capture probe

A system and method for sampling a sample material includes a device for directing sample into a capture probe. The device for supplying sample material to the probe can be a device for radiating energy to the surface to eject sample from the sample material. A probe includes an outer probe housing having an open end. A liquid supply conduit has an outlet positioned to deliver liquid to the open end. An exhaust conduit removes liquid from the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust system can be in fluid connection with the liquid exhaust conduit for removing liquid from the liquid exhaust conduit at a second volumetric flow rate such that gas with sample is withdrawn with the liquid.

Kertesz, Vilmos↗

Capture probe

A system and method for sampling a sample material includes a device for directing sample into a capture probe. The device for supplying sample material to the probe can be a device for radiating energy to the sample material to eject sample from the sample material. A probe includes an outer probe housing having an open end. A liquid supply conduit has an outlet positioned to deliver liquid to the open end. An exhaust conduit removes liquid from the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust system can be in fluid connection with the liquid exhaust conduit for removing liquid from the liquid exhaust conduit at a second volumetric flow rate such that gas with sample is withdrawn with the liquid.

Kertesz, Vilmos↗

Open port sampling interface

A system for sampling a sample material includes a probe which can have an outer probe housing with an open end. A liquid supply conduit within the housing has an outlet positioned to deliver liquid to the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust conduit within the housing is provided for removing liquid from the open end of the housing. A liquid exhaust system can be provided for removing liquid from the liquid exhaust conduit at a second volumetric flow rate. A droplet dispenser can dispense drops of a sample or a sample-containing solvent into the open end of the housing. A sensor and a processor can be provided to monitor and maintain a liquid dome present at the open end.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Open port sampling interface

A system for sampling a sample material includes a probe which can have an outer probe housing with an open end. A liquid supply conduit within the housing has an outlet positioned to deliver liquid to the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust conduit within the housing is provided for removing liquid from the open end of the housing. A liquid exhaust system can be provided for removing liquid from the liquid exhaust conduit at a second volumetric flow rate. A droplet dispenser can dispense drops of a sample or a sample-containing solvent into the open end of the housing. A sensor and a processor can be provided to monitor and maintain a liquid dome present at the open end.

Van Berkel, Gary J.↗

Open port sampling interface

A system for sampling a sample material includes a probe which can have an outer probe housing with an open end. A liquid supply conduit within the housing has an outlet positioned to deliver liquid to the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust conduit within the housing is provided for removing liquid from the open end of the housing. A liquid exhaust system can be provided for removing liquid from the liquid exhaust conduit at a second volumetric flow rate. A droplet dispenser can dispense drops of a sample or a sample-containing solvent into the open end of the housing. A sensor and a processor can be provided to monitor and maintain a liquid dome present at the open end.

Van Berkel, Gary J.↗

Open port sampling interface

A system for sampling a sample material includes a probe which can have an outer probe housing with an open end. A liquid supply conduit within the housing has an outlet positioned to deliver liquid to the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust conduit within the housing is provided for removing liquid from the open end of the housing. A liquid exhaust system can be provided for removing liquid from the liquid exhaust conduit at a second volumetric flow rate. A droplet dispenser can dispense drops of a sample or a sample-containing solvent into the open end of the housing. A sensor and a processor can be provided to monitor and maintain a liquid dome present at the open end.

Van Berkel, Gary J.↗

Open port sampling interface

A system for sampling a sample material includes a probe which can have an outer probe housing with an open end. A liquid supply conduit within the housing has an outlet positioned to deliver liquid to the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust conduit within the housing is provided for removing liquid from the open end of the housing. A liquid exhaust system can be provided for removing liquid from the liquid exhaust conduit at a second volumetric flow rate. A droplet dispenser can dispense drops of a sample or a sample-containing solvent into the open end of the housing. A sensor and a processor can be provided to monitor and maintain a liquid dome present at the open end.

Van Berkel, Gary J.↗