Search NASA⌕ Search

SEARCH · Search NASA

Results for “EXTERNAL BEAM RADIATION THERAPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Impact of High-Dose-Rate and Low-Dose-Rate Brachytherapy Boost on Toxicity, Functional and Cancer Outcomes in Patients Receiving External Beam Radiation Therapy for Prostate Cancer: A National Population-Based Study

External beam radiation therapy (EBRT) with brachytherapy boost reduces cancer recurrence in patients with prostate cancer compared with EBRT monotherapy. However, randomized controlled trials or large-scale observational studies have not compared brachytherapy boost types directly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Summation Strategies for External Beam Radiation Therapy and Brachytherapy in Gynecologic Malignancy: A Review from the NRG Oncology and NCTN Medical Physics Subcommittees

Definitive, nonsurgical management of gynecologic malignancies involves external beam radiation therapy (EBRT) and/or brachytherapy (BT). Summation of the cumulative dose is critical to assess the total biologic effective dose to targets and organs at risk. Cumulative dose calculation from EBRT and BT can be performed with or without image registration (IR) and biologic dose summation. Among these dose summation strategies, linear addition of dose-volume histogram (DVH) parameters without IR is the global standard for composite dose reporting. This approach stems from an era without image guidance and simple external beam and brachytherapy treatment approaches. With technological advances, EBRT and high-dose-rate BT have evolved to allow for volume-based treatment planning and delivery. Modern conformal therapeutic radiation involves volumetric or intensity modulated EBRT, capable of simultaneously treating multiple targets at different specified dose levels. Therefore, given the complexity of modern radiation treatment, the linear addition of DVH parameters from EBRT and high-dose-rate BT is challenging to represent the combined dose distribution. Deformable image registration (DIR) between EBRT and image guided brachytherapy (IGBT) data sets may provide a more nuanced calculation of multimodal dose accumulation. However, DIR is still nascent in this regard, and needs further development for accuracy and efficiency for clinical use. Biologic dose summation can combine physical dose maps from EBRT and each IGBT fraction, thereby generating a composite DVH from the biologic effective dose. However, accurate radiobiologic parameters are tissue-dependent and not well characterized. A combination of voxel-based DIR and biologic weighted dose maps may be the best approximation of dose accumulation but remains invalidated. The purpose of this report is to review dose summation strategies for EBRT and BT, including conventional equivalent dose in 2-Gy fractions dose summation without image registration, physical dose summation using 3-dimensional rigid IR and DIR, and biologic dose summation. We also provide general clinical workflows for IGBT with a focus on cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Estimates of Alpha/Beta (α/β) Ratios for Individual Late Rectal Toxicity Endpoints: An Analysis of the CHHiP Trial

Changes in fraction size of external beam radiation therapy exert nonlinear effects on subsequent toxicity. Commonly described by the linear-quadratic model, fraction size sensitivity of normal tissues is expressed by the α/β ratio. We sought to study individual α/β ratios for different late rectal effects after prostate external beam radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Overcoming Barriers to Radiopharmaceutical Therapy (RPT): An Overview From the NRG-NCI Working Group on Dosimetry of Radiopharmaceutical Therapy

Radiopharmaceutical therapy (RPT) continues to demonstrate tremendous potential in improving the therapeutic gains in radiation therapy by specifically delivering radiation to tumors that can be well assessed in terms of dosimetry and imaging. Dosimetry in external beam radiation therapy is standard practice. This is not the case, however, in RPT. This NRG (acronym formed from the first letter of the 3 original groups: National Surgical Adjuvant Breast and Bowel Project, the Radiation Therapy Oncology Group, and the Gynecologic Oncology Group)-National Cancer Institute Working Group review describes some of the challenges to improving RPT. The main priorities for advancing the field include (1) developing and adopting best practice guidelines for incorporating patient-specific dosimetry for RPT that can be used at both large clinics with substantial resources and more modest clinics that have limited resources, (2) establishing and improving strategies for introducing new radiopharmaceuticals for clinical investigation, (3) developing approaches to address the radiophobia that is associated with the administration of radioactivity for cancer therapy, and (4) solving the financial and logistical issues of expertise and training in the developing field of RPT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Behavioral Determinants of Canadian Radiation Oncologists’ Use of Single Fraction Palliative Radiation Therapy for Uncomplicated Bone Metastases

A mainstay therapy for pain relief from uncomplicated bone metastases is external beam radiation therapy. Single fraction radiation therapy (SFRT) is more convenient and cost-effective, causes fewer acute side effects, and is equivalent to multiple fraction radiation therapy for pain relief. Despite these advantages, radiation oncologists seldom prescribe SFRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pain Response After Stereotactic Body Radiation Therapy Versus Conventional Radiation Therapy in Patients With Bone Metastases—A Phase 2 Randomized Controlled Trial Within a Prospective Cohort

Pain response after conventional external beam radiation therapy (cRT) in patients with painful bone metastases is observed in 60% to 70% of patients. The aim of the VERTICAL trial was to investigate whether stereotactic body radiation therapy (SBRT) improves pain response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Trends in Radiation Therapy for Bone Metastases, 2015 to 2017: Choosing Wisely in the Era of Complex Radiation

Guidelines recommend short-course (≤10 fractions) external-beam radiation therapy (EBRT) for bone metastases. Stereotactic body radiation therapy (SBRT) may also improve outcomes; however, routine use is not recommended outside clinical trials. We assessed national radiation therapy trends in complex techniques for bone metastases and associated expenditures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tumor Control Probability Modeling and Systematic Review of the Literature of Stereotactic Body Radiation Therapy for Prostate Cancer

Dose escalation improves localized prostate cancer disease control, and moderately hypofractionated external beam radiation is noninferior to conventional fractionation. The evolving treatment approach of ultrahypofractionation with stereotactic body radiation therapy (SBRT) allows possible further biological dose escalation (biologically equivalent dose [BED]) and shortened treatment time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo simulation of shielding designs for a cabinet form factor preclinical MV–energy photon FLASH radiotherapy system

Purpose: A preclinical MV-energy photon FLASH radiotherapy system is being designed at Stanford and SLAC National Accelerator Laboratory. Because of the higher energy and dose rate compared to conventional kV-energy photon laboratory-scale irradiators, adequate shielding in a stand-alone cabinet form factor is more challenging to achieve. We present a Monte Carlo simulation of multilayered shielding for a compact self-shielding system without the need for a radiation therapy vault. Methods: A multilayered shielding approach using multiple alternating layers of high-Z and low-Z materials is applied to the self-shielded cabinet to effectively mitigate the secondary radiation produced and to allow the device to be housed in a Controlled Radiation Area outside of a radiation vault. The multilayered shielding approach takes advantage of the properties of high-Z and low-Z radiation shielding materials such as density, cross-section, atomic number of the shielding elements, and products of radiation interactions within each layer. The Monte Carlo radiation transport code, FLUKA, is used to simulate the total effective dose produced by the operation. Results: The multilayered shielding designs proposed and simulated produced effective dose rates significantly lower than monolayer designs with the same total material thickness at the regulatory boundary; this is accomplished through the manipulation of the locations where secondary radiation is produced and reactions due to material properties such as neutron back reflection in hydrogen. Borated polyethylene at 5 wt% significantly increased the shielding performance as compared to regular polyethylene, with the magnitude of the reduction depending upon the order of the shielding material. Conclusions: The multilayered shielding provides a path for shielding preclinical FLASH systems that deliver MV-energy bremsstrahlung photons. Furthermore, this approach promises to be more efficient with respect to the shielding material mass and space claim as compared to shielded vaults typically required for clinical radiation therapy with MV photons.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nanoparticles for targeted cancer radiotherapy

Radiotherapy, where ionizing radiation is locally delivered either through an external beam or by surgically implanting radionuclide-based seeds in the tumor, is one of the gold standard treatments for cancer. Due to the non-selective nature of radiation, healthy tissue surrounding the cancerous region is usually affected by the treatment. Hence, new strategies, including targeted alpha therapy, are being studied to improve the selectivity of the treatment and minimize side effects. Several challenges, however, limit the current development of targeted radiotherapy, such as the functionalization of the therapeutic agent with targeting vectors and controlling the release of recoiling daughters. Nanoparticles offer unique opportunities as drug delivery vehicles, since they are biocompatible, enhance the cellular uptake of drugs, and are easily functionalized with targeting molecules. In this review, we examine how nanoparticles can be used for targeted radiotherapy, either as sensitizers of external beams or as delivery vehicles for therapeutic radionuclides. Further, we describe the clinical relevance of different types of nanoparticles, followed by an analysis of how these nanoconstructs can solve some of the main limitations of conventional radiotherapy. Finally, we critically discuss the current situation of nanoparticle-based radiotherapy in clinical settings and challenges that need to be overcome in the future for further development of the field.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel Bremsstrahlung Converter Designs for Ultra High Dose Rate Radiotherapy Systems

Ultra-high dose rates (UHDR) have been shown to improve the therapeutic index in the treatment of cancer using external beam radiotherapy in many preclinical settings by inducing the so-called “FLASH” effect [1]; however, the underlying biological and physical mechanism(s) are still unknown. Recent work has been to expand the energy range of photons used in UHDR studies from keV photons generated in synchrotron to photons less than 8 MeV produced by accelerated electrons undergoing the bremsstrahlung interaction [2]. This work is a part of the FLASH-Experimental X-ray small Animal Conformal Therapy (FLASH-EXACT) project is aimed at producing a preclinical system that induces the FLASH effect with photons >10 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗

Shielding Analysis of a Preclinical Bremsstrahlung X-ray FLASH Radiotherapy System within a Clinical Radiation Therapy Vault

A preclinical radiotherapy system producing FLASH dose rates with 12 MV bremsstrahlung x rays is being developed at Stanford University and SLAC National Accelerator Laboratory. Because of the high expected workload of 6,800 Gy w –1 at the isocenter, an efficient shielding methodology is needed to protect operators and the public while the preclinical system is operated in a radiation therapy vault designed for 6 MV x rays. Here, in this study, an analysis is performed to assess the shielding of the local treatment head and radiation vault using the Monte Carlo code FLUKA and the empirical methodology given in the National Council on Radiation Protection and Measurements Report 151. Two different treatment head shielding designs were created to compare single-layer and multilayer shielding methodologies using high-Z and low-Z materials. The multilayered shielding methodology produced designs with a 17% reduction in neutron fluence leaking from the treatment head compared to the single layered design of the same size, resulting in a decreased effective dose to operators and the public. The conservative assumptions used in the empirical methods can lead to over-shielding when treatment heads use polyethylene or multilayered shielding. High-Z/Low-Z multilayered shielding optimized via Monte Carlo is shown to be effective in the case of treatment head shielding and provide more effective shielding design for external beam radiotherapy systems that use 12 MV bremsstrahlung photons. Modifications to empirical methods used in the assessment of MV radiotherapy systems may be warranted to capture the effects of polyethylene in treatment head shielding.

61 RADIATION PROTECTION AND DOSIMETRY↗