Search NASA⌕ Search

SEARCH · Search NASA

Results for “EXTINGUISHER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Enhancing and Extinguishing the Different Emission Features of 2D (EA(1-)(x)FA(x))(4)Pb3Br10 Perovskite Films

2D hybrid perovskites are attractive for optoelectronic devices. In thin films, the color of optical emission and the texture of crystalline domains are often difficult to control. Here, a method for extinguishing or enhancing different emission features is demonstrated for the family of 2D Ruddlesden-Popper perovskites (EA(1-)(x)FA(x))(4)Pb3Br10 (EA = ethylammonium, FA = formamidinium). When grown from aqueous hydrobromic acid, crystals of (EA(1-)(x)FA(x))(4)Pb3Br10 retain all the emission features of their parent compound, (EA)(4)Pb3Br10. Surprisingly, when grown from dimethylformamide (DMF), an emission feature, likely self-trapped exciton (STE), near 2.7 eV is missing. Extinction of this feature is correlated with DMF being incorporated between the 2D Pb-Br sheets, forming (EA(1-)(x)FA(x))(4)Pb3Br10 center dot(DMF)(y). Without FA, films grown from DMF form (EA)(4)Pb3Br10, retain little solvent, and have strong emission near 2.7 eV. Slowing the kinetics of film growth strengthens a different emission feature, likely a different type of STE, which is much broader and present in all compositions. Films of (EA(1-)(x)FA(x))(4)Pb3Br10 center dot(DMF)(y) have large, micron-sized domains and homogeneous orientation of the semiconducting sheets, resulting in low electronic disorder near the absorption edge. The ability to selectively strengthen or extinguish different emission features in films of (EA(1-)(x)FA(x))(4)Pb3Br10 center dot(DMF)(y) reveals a pathway to tune the emission color in these compounds.

2D halide perovskites↗

Fire Extinguisher Training for Fire Watch and Designated Workers, Course 9893

At Los Alamos National Laboratory (LANL), all workers must be aware of LANL fire protection policies and be trained on what to do in the event of a fire. This course, Fire Extinguisher Training for Fire Watch and Designated Workers (#9893), provides awareness-level and hands-on training for fire watch personnel and designated workers. Fire watch personnel and designated workers are appointed by line management and must receive both awareness-level training and hands-on training in the use of portable fire extinguishers to extinguish an incipient-stage fire. This training meets the requirements of the Occupational Safety and Health Administration (OSHA) Code of Federal Regulations (CFR) 29 CFR 1910.157, Portable Fire Extinguishers, and Procedure (P) 101-26, Welding, Cutting, and Other Spark-/Flame-Producing Operations.

99 GENERAL AND MISCELLANEOUS↗

Fire Extinguisher Designated Worker and Fire Watch: Self-Study Course 15672

At Los Alamos National Laboratory (LANL), all workers must be aware of LANL fire protection policies and be trained on what to do in the event of a fire. This course, Fire Extinguisher Training for Fire Watch and Designated Workers (#9893), provides awareness-level and hands-on training for fire watch personnel and designated workers. Fire watch personnel and designated workers are appointed by line management and must receive both awareness-level training and hands-on training in the use of portable fire extinguishers to extinguish an incipient-stage fire. This training meets the requirements of the Occupational Safety and Health Administration (OSHA) Code of Federal Regulations (CFR) 29 CFR 1910.157, Portable Fire Extinguishers, and Procedure (P) 101-26, Welding, Cutting, and Other Spark-/Flame-Producing Operations.

99 GENERAL AND MISCELLANEOUS↗

Incidental Reflector Comparison of Containerized Dry Fire Extinguishing Agents

This document addresses the incidental reflector reactivity worth of containerized fire extinguishing agents authorized for use in PF-4 at Los Alamos National Laboratory (LANL). The intent of the document is to analyze dry fire extinguishing agent that remains in a container and is not actively being used in a fire emergency. The incidental reflector reactivity worth is determined by comparison to various thicknesses of close fitting water reflection which is commonly used to bound incidental reflectors in criticality safety evaluations. The conclusion is that even in unlimited quantities, when containerized the authorized dry fire extinguishing agents are bound by 0.4 inches of close fitting water.

36 MATERIALS SCIENCE↗

Ultralight and fire-extinguishing current collectors for high-energy and high-safety lithium-ion batteries

Inactive components and safety hazards are two critical challenges in realizing high-energy lithium-ion batteries. Metal foil current collectors with high density are typically an integrated part of lithium-ion batteries yet deliver no capacity. Meanwhile, high-energy batteries can entail increased fire safety issues. Here we report a composite current collector design that simultaneously minimizes the ‘dead weight’ within the cell and improves fire safety. An ultralight polyimide-based current collector (9 μm thick, specific mass 1.54 mg cm-2) is prepared by sandwiching a polyimide embedded with triphenyl phosphate flame retardant between two superthin Cu layers (~500 nm). Compared to lithium-ion batteries assembled with the thinnest commercial metal foil current collectors (~6 µm), batteries equipped with our composite current collectors can realize a 16-26% improvement in specific energy and rapidly self-extinguish fires under extreme conditions such as short circuits and thermal runaway.

25 ENERGY STORAGE↗

How Much Attenuation Extinguishes mm-Wave Vertically Pointing Radar Return Signals?

Vertically pointing radars (VPRs) operating at millimeter wavelengths measure the power return from raindrops enabling precipitation retrievals as a function of height. However, as the rain rate increases, there are combinations of rain rate and rain path length that produce sufficient attenuation to prevent the radar from detecting raindrops all the way through rain shafts. This study explores the question: Which rain rate and path length combinations completely extinguish radar return signals for VPRs operating between 3 and 200 GHz? An important step in these simulations is converting attenuated radar reflectivity factor into radar received signal-to-noise ratio (SNR) in order to determine the range where the SNR drops below the receiver detection threshold. Configuring the simulations to mimic a U.S. Department of Energy Atmospheric Radiation Mission (ARM) W-band (95 GHz) radar deployed in Brazil, the simulation results indicate that a W-band radar could observe raindrops above 3.5 km only when the rain rate was less than approximately 4 mm h -1 . The deployed W-band radar measurements confirm the simulation results with maximum observed heights ranging between 3 and 4.5 km when a surface disdrometer measured 4 mm h -1 rain rate (based on 25-to-75 percentiles from over 25,000 W-band radar profiles). In summary, this study contributes to our understanding of how rain and atmospheric gas attenuation impacts the performance of millimeter-wave VPRs and will help with the design and configuration of multi-frequency VPRs deployed in future field campaigns.

54 ENVIRONMENTAL SCIENCES↗

UKIRT MICROLENSING SURVEYS AS A PATHFINDER FOR WFIRST: THE DETECTION OF FIVE HIGHLY EXTINGUISHED LOW-|b| EVENTS

Optical microlensing surveys are restricted from detecting events near the Galactic plane and center, where the event rate is thought to be the highest due to the high optical extinction of these fields. In the near-infrared (NIR), however, the lower extinction leads to a corresponding increase in event detections and is a primary driver for the wavelength coverage of the WFIRST microlensing survey. During the 2015 and 2016 bulge observing seasons, we conducted NIR microlensing surveys with UKIRT in conjunction with and in support of the Spitzer and Kepler microlensing campaigns. Here, we report on five highly extinguished (A{sub H}=0.81--1.97), low-Galactic latitude (−0.98⩽b⩽−0.36) microlensing events discovered from our 2016 survey. Four of them were monitored with an hourly cadence by optical surveys but were not reported as discoveries, likely due to the high extinction. Our UKIRT surveys and suggested future NIR surveys enable the first measurement of the microlensing event rate in the NIR. This wavelength regime overlaps with the bandpass of the filter in which the WFIRST microlensing survey will conduct its highest-cadence observations, making this event rate derivation critically important for optimizing its yield.

79 ASTRONOMY AND ASTROPHYSICS↗

Mode-of-Action of Self-Extinguishing Polymer Blends Containing Organoclays

We have shown that the addition of nanoclays is an effective means for enhancing the flame retardant properties of polymer blends. Polymer blends are difficult to render flame retardant even with the addition of flame retardant agents due to dispersion and phase segregation during the heating process. We show that the addition of 5% functionalized Cloisite 20A clays in combination with 15% decabromodiphenyl ether and 4% antimony trioxide to a polystyrene/poly(methyl methacrylate) blend can render the compound flame resistant within the UL-94-V0 standard. Using a variety of micro-characterization methods, we show that the clays are concentrated at the interfaces between the polymers in this blend and completely suppress phase segregation. The flame retardant (FR) is absorbed onto the clay surfaces, and the exfoliation of the clays also distributes the FR agent uniformly within the matrix. TGA of the nanocomposite indicates that prior to the addition of clay, the dissociation times of the individual components varied by more than 20 C, which complicated the gas-phase kinetics. Addition of the clays causes all the components to have a single dissociation temperature, which enhanced the efficacy of the FR formula in the gas phase. Cone calorimetry also indicated that the clays decreased the heat release rate (HRR) and the mass loss rate (MLR), due to the formation of a robust char. In contrast, minimal charring occurred in blends containing just the FR. SEM examination of the chars showed that the clay platelets were curved and in some cases tightly folded into nanotube-like structures. These features were only apparent in blends, indicating that they might be associated with thermal gradients across the polymer phase interface. SEM and SAXS examinations of the nanocomposites after partial exposure to the flame indicated that the clays aggregated into ribbon-like structures, approximately microns in length, after the surfactant thermally decomposed. Thermal modeling indicated that these ribbons might partially explain the synergy due to better distribution of the heat and improve the mechanical properties of the melt at high temperatures, in a manner similar to the one reported for carbon nanotubes.

36 MATERIALS SCIENCE↗

Taking the Air Out of Respiratory Pandemics: An R&D Effort for Developing New, Far Less Disruptive and Frightening Protective Measures to Extinguish Airborne Pathogen Outbreaks

This short concept article discusses four specific ways to eradicate respiratory pandemics once and for all. These include: Protecting the nose, mouth, throat and lungs; New hygiene regimens; Clearing the air; and Biophysical interventions. Technical breakthoughs in all four of these areas would not only protect people from life-threatening pathogens, but also take the dread out of respiratory disease outbreaks.

59 BASIC BIOLOGICAL SCIENCES↗

System for multiple burns from a rocket motor

A system for multiple burns from a solid fuel rocket motor may extinguish rocket fuel after the rocket has been ignited. The motor may be extinguished via rapid decompression of the combustion chamber. The fuel may then be reignited by a suitable igniter, and the process of extinguishing and reigniting may be repeated, enabling multi-burn maneuvers. A decompressive extinguishing plug nozzle may extinguish solid rocket fuel after the rocket has been ignited and/or keep a rocket in a disarmed (zero thrust) state until the rocket is to be armed. The nozzle may include a plug that mostly impedes the opening of the nozzle and an outer cowl that is movable to rapidly decompress the combustion chamber. This rapid decompression extinguishes the solid rocket fuel. In some aspects, the fuel can be reignited and extinguished multiple times.

Dallmann, Nicholas↗

Reliability study of an emerging fire suppression system

Self-contained fire extinguishers are a robust, reliable and minimally invasive means of fire suppression for gloveboxes. Plutonium gloveboxes are known to present harsh environmental conditions for polymer materials, these include radiation damage and chemical exposure, both of which tend to degrade the lifetime of engineered polymer components. The primary component of interest in self-contained fire extinguishers is the nylon 6-6 machined tube that comprises the main body of the system.Thermo-mechanical modeling and characterization of nylon 6-6 for use in plutonium glovebox applications has been carried out. Data has been generated regarding property degradation leading to poor, or reduced, engineering performance of nylon 6-6 components. In this study, nylon 6-6 tensile specimens conforming to the casing of self-contained fire extinguisher systems have been exposed to hydrochloric, nitric, and sulfuric acids. This information was used to predict the performance of a load bearing engineering component comprised of nylon 6-6 and designed to operate in a consistent manner over a specified time period. The study provides a fundamental understanding of the engineering performance of the fire suppression system and the effects of environmental degradation due to acid exposure on engineering performance. Data generated help identify the limitations of self-contained fire extinguishers. No critical areas of concern for plutonium glovebox applications of nylon 6-6 have been identified when considering exposure to mineral acid.

36 MATERIALS SCIENCE↗

Verification study of an emerging fire suppression system

Self-contained fire extinguishers are a robust, reliable and minimally invasive means of fire suppression for gloveboxes. Moreover, plutonium gloveboxes present harsh environmental conditions for polymer materials; these include radiation damage and chemical exposure, both of which tend to degrade the lifetime of engineered polymer components. Several studies have been conducted to determine the robustness of selfcontained fire extinguishers in plutonium gloveboxes in a nuclear facility, verification tests must be performed. These tests include activation and mass loss calorimeter tests. In addition, compatibility issues with chemical components of the self-contained fire extinguishers need to be addressed. Our study presents activation and mass loss calorimeter test results. After extensive studies, no critical areas of concern have been identified for the plutonium glovebox application of Fire Foe™, except for glovebox operations that use large quantities of bulk plutonium or uranium metal such as metal casting and pyro-chemistry operations.

42 ENGINEERING↗

Effect of NO on extinction and re-ignition of vortex-perturbed hydrogen flames

The catalytic effect of nitric oxide (NO) on the dynamics of extinction and re-ignition of a vortex-perturbed non-premixed hydrogen-air flame is studied in a counterflow burner. A diffusion flame is established with counterflowing streams of nitrogen-diluted hydrogen at ambient temperature and air heated to a range of temperatures that brackets the auto-ignition temperature. Localized extinction is induced by impulsively driving a fuel-side toroidal vortex into the steady flame, and the recovery of the extinguished region is monitored by planar laser-induced fluorescence (PLIF) of the hydroxyl radical (OH). The dynamics of flame recovery depend on the air temperature and fuel concentration, and four different recovery modes are identified. These modes involve combinations of edge-flame propagation and the expansion of an auto-ignition kernel that forms within the extinguished region. The addition of a small amount of NO significantly alters the re-ignition process by shifting the balance between chain-termination and chain-propagation reactions to enhance auto-ignition. The ignition enhancement by this catalytic effect causes a shift in the conditions that govern the recovery modes. In addition, the effects of NO concentration and vortex strength on the flame recovery are examined. Direct numerical simulations of the flame-vortex interaction with and without NO doping show how the small amount of OH produced by NO-catalyzed reactions has a significant impact on the development of an auto-ignition kernel. This joint experimental and numerical study provides detailed insight into the interaction between transient flows and ignition processes. (author)

08 HYDROGEN↗

Blowoff dynamics of bluff body stabilized turbulent premixed flames

This article concerns the flame dynamics of a bluff body stabilized turbulent premixed flame as it approaches lean blowoff. Time resolved chemiluminescence imaging along with simultaneous particle image velocimetry and OH planar laser-induced fluorescence were utilized in an axisymmetric bluff body stabilized, propane-air flame to determine the sequence of events leading to blowoff and provide a quantitative analysis of the experimental results. It was found that as lean blowoff is approached by reduction of equivalence ratio, flame speed decreases and the flame shape progressively changes from a conical to a columnar shape. For a stably burning conical flame away from blowoff, the flame front envelopes the shear layer vortices. Near blowoff, the columnar flame front and shear layer vortices overlap to induce high local stretch rates that exceed the extinction stretch rates instantaneously and in the mean, resulting in local flame extinction along the shear layers. Following shear layer extinction, fresh reactants can pass through the shear layers to react within the recirculation zone with all other parts of the flame extinguished. This flame kernel within the recirculation zone may survive for a few milliseconds and can reignite the shear layers such that the entire flame is reestablished for a short period. This extinction and reignition event can happen several times before final blowoff which occurs when the flame kernel fails to reignite the shear layers and ultimately leads to total flame extinguishment. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recurrent dynamics in an epidemic model due to stimulated bifurcation crossovers

Epidemics are known to persist in the form of recurrence cycles. Despite intervention efforts through vaccination and targeted social distancing, peaks of activity for infectious diseases like influenza reappear over time. Analysis of a stochastic model is here undertaken to explore a proposed cycle-generating mechanism – the bifurcation crossover. Time series from simulations of the model exhibit oscillations similar to the temporal signature of influenza activity. Power-spectral density indicates a resonant frequency, which corresponds to the annual seasonality of influenza in temperate zones. The study finds that intervention actions influence the extinguishability of epidemic activity. Asymptotic solution to a backward Kolmogorov equation corresponds to a mean extinction time that is a function of both intervention efficacy and population size. Intervention efficacy must be greater than a certain threshold to increase the chances of extinguishing the epidemic. Agreement of the model with several phenomenological features of epidemic cycles lends to it a tractability that may serve as early warning of imminent outbreaks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗