Search NASASearch

SEARCH · Search NASA

Results for “Efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Data for Nitrogen Dynamics and Physiological N Use Efficiency in High-biomass Sorghum

Improving nitrogen (N) efficiency is essential for sustainable high-biomass sorghum ( Sorghum bicolor L. Moench ) production. This study evaluated leaf and stem N dynamics, canopy N remobilization, and physiological nitrogen use efficiency (pNUE) in two photoperiod-sensitive sorghum hybrids under two N rates (0 and 168 kg-N ha−1) across multiple environments in Texas and Illinois. Leaf N concentrations increased with plant height in the canopy with steeper gradients under low-N conditions, indicating enhanced N remobilization when N is limited. Stem tissue showed less variation in N concentration across canopy nodal positions, with within-plant differences ranging from 1.2 to 7.6 g kg−1, compared to 3.1 to 16.3 g kg−1 in leaves. While pNUE was generally higher under unfertilized conditions, it varied largely by site; however, genotypic differences were minimal within the given year. These results highlight the importance of integrating environmental and management factors into breeding and fertilization strategies to enhance N efficiency in high-biomass sorghum.

Nitrogen

Online multi-objective Bayesian optimization of injection efficiency and beam lifetime with skew quadrupoles at NSLS-II

At NSLS-II, the vertical emittance of electron beam is typically blown up to ~30 pm with a coupling wave to increase beam lifetime during user operation. As more and more insertion devices are added to the storage ring, injection efficiency to the ring drops noticeably in certain machine states, apparently due to degraded dynamic apertures. To help alleviate this issue, we have recently performed online multi-objective Bayesian optimization to increase injection efficiency while maintaining beam lifetime, by adjusting the strengths of 15 skew quadrupoles in non-dispersive sections. We report the results of this optimization effort.

Hidaka, Yoshiteru [Brookhaven]

Enhancing Building Resilience: Maintaining Energy Efficiency and Thermal Comfort During Power Outages in Cold Climates

The increasing frequency and intensity of extreme weather events, such as heatwaves and cold snaps, present significant challenges to building energy performance and occupant comfort. Highly correlated with climate events are widespread long duration power interruptions that may affect thousands of buildings and millions of customers. This study evaluates the impact of building energy performance and occupant thermal comfort in medium-sized office buildings in a cold climate region. Using energy models representing pre-1980 and 2019 vintages, simulations were conducted to assess energy performance under typical weather conditions and occupant thermal comfort during power interrupted extreme cold snap and heatwave climate events under both current 2020s and future 2050s weather conditions. The results show a projected 33% increase in cooling energy demand and a 19% reduction in heating energy by 2050. Findings reveal that older buildings are more susceptible to cold discomfort during cold snaps, while modern airtight buildings are more vulnerable to overheating during heatwaves. Various passive energy efficiency measures, such as improved infiltration control, thermal windows, solar-controlled windows, and cool envelopes, were evaluated for their ability to mitigate thermal discomforts. Solar controlled windows and weatherstripping contribute to reducing cold thermal discomfort by 21% during a power-interrupted cold snap. Solar-controlled windows were found to reduce hot thermal discomfort by 34% during a future power-interrupted heatwave. The study highlights the importance of targeted retrofitting strategies to enhance thermal resilience, especially during power outages, to ensure occupant safety and comfort during extreme climate events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Comparison of measured efficiencies of nine turbine designs with efficiencies predicted by two empirical methods

Empirical methods of Ainley and Kochendorfer and Nettles were used to predict performances of nine turbine designs. Measured and predicted performances were compared. Appropriate values of blade-loss parameter were determined for the method of Kochendorfer and Nettles. The measured design-point efficiencies were lower than predicted by as much as 0.09 (Ainley and 0.07 (Kochendorfer and Nettles). For the method of Kochendorfer and Nettles, appropriate values of blade-loss parameter ranged from 0.63 to 0.87 and the off-design performance was accurately predicted.

FLOW-TURBINES

Toward a second generation fuel efficient supersonic cruise aircraft structural design for efficiency

The unique challenge of this concept to the structural designer is discussed. The potential of the application of advanced structural design concepts and new titanium fabrication processes is emphasized. Highlighted are the results of a detailed structural analysis, including weight and flutter, showing successful use of the ATLAS structural design and analysis system. It is concluded that blending of the structure may not have an adverse impact on structural efficiency, weight, and manufacturing complexity.

Hoy, J. R.

Data for An Orphan Gene BOOSTER Enhances Photosynthetic Efficiency and Plant Productivity

Seeds of Col-0 wild type, sig6 T-DNA mutants (CS877785, ABRC), PRL-1-OE, and sig6 T-DNA mutants transfected with PRL-1 (sig6::PRL-1) were planted in 1/2 MS media. Seedlings growth including chlorophyll development defects were investigated across the genotypes. Four-days-old-post-light exposure seedlings were harvested and performed RNAseq analysis with four biological replicates.

Biomass Analytics

Additively Reinforced Thermoformable PETG Composite Sheets for Improved Structural Efficiency

Thermoforming of short-fiber reinforced thermoplastic sheets offers a viable pathway for producing lightweight composite components; however, inherent anisotropy in fiber-reinforced sheets can limit structural performance under multidirectional loading. In this work, short carbon fiber, glass fiber, and hybrid fiber–reinforced PETG sheets were evaluated as candidate feedstock materials for thermoforming, with flexural and tensile testing performed both along the primary fiber direction and in the off-axis orientation to establish baseline stiffness, strength, and anisotropy. As expected, short carbon fiber PETG exhibited the highest stiffness and strength in the primary fiber direction, while all systems showed reduced performance in the off-axis direction. This off-axis performance reduction provides clear justification for the use of additive reinforcement when such thermoformed sheets are intended for structural applications. The intended manufacturing sequence involves thermoforming the reinforced sheet first, followed by the application of additively manufactured lattice reinforcement; therefore, the reinforcement strategy does not impose limitations on sheet formability during thermoforming. Post-forming lattice reinforcement significantly reduced load-normalized displacement by approximately 95–99% relative to non-reinforced sheets and improved weight-normalized stiffness by ~70%. These findings demonstrate that geometry-driven additive reinforcement can effectively compensate for off-axis property reductions in thermoformed PETG composites, enabling enhanced multidirectional structural performance without compromising manufacturability.

Talabi, Isaac [ORNL] (ORCID:0000000340215594)

Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology

Refrigerator technology has advanced significantly over the last couple of decades. Today’s refrigerators use only about 25% of the energy that was required to power models built in 1975. Even as they continually improve efficiency to meet standards, refrigerators have increased in size by almost 20%, added energy-consuming features such as through-the-door ice, and provide more benefits than ever before. However, a few challenges and technology gaps are preventing further improvement of the demand responsiveness and efficiency of the refrigerators. One of the major technology gaps in existing refrigerators is their outdated de-icing process. When the evaporator generates frost, an old-fashioned resistive heating element melts the ice. Most refrigerators have a timed defrost cycle, rather than an active system that could monitor the state of the frost. In these systems, not only is the precious electricity used at its least efficient form of conversion (direct conversion of electricity to heat), but also all the latent heat associated with the ice is wasted during the melting process. On top of that, the refrigerator needs to work harder to pull the temperature down after defrosting, and, last but not least, the food quality is severely impacted by the temperature swings during the defrost cycle. According to a study, the EU alone wastes 89 million tons of food in the supply chain every year. Any temperature swing during defrosting (about 6F according to Emerson for low-temperature cases) can negatively impact the shelf life of meat and other products for multiple days. All these issues can happen during the peak demand time of the electric grid. Unlike the conventional systems, the proposed novel advanced micro-vibrational deicing process uses no heat for defrosting. Instead, it uses the micro vibrations generated by a piezoelectric or vibration-generating module to mechanically break ice from the heat exchanger almost instantaneously. The project titled “Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology, performed by Ultrasonic Technology Solutions, LLC (UTS) of Knoxville, TN, in collaboration with Emerson (now Copeland), represents the final phase of a multi-year effort funded under the U.S. Department of Energy’s Building Technologies Office (BTO) BENEFIT FOA 2020. Initiated on October 1, 2021, and completed after a nine-month no-cost extension ending September 30, 2025, this project aimed to develop and validate a novel micro-vibrational mechanical defrosting system, achieving more than 25% improvement in defrosting energy efficiency over conventional baseline defrosting technologies. Over sixteen quarters, the project advanced from fundamental ice-mechanical characterization and prototype development to full-scale system integration and validation. Initial efforts established project management infrastructure and characterized ice adhesion properties, followed by the design and fabrication of early aluminum-based prototypes for resonance frequency testing. Subsequent quarters saw rapid technical progression, including the identification of optimal piezoelectric and motor-based vibration mechanisms, the demonstration of effective de-icing over 6x6-inch aluminum surfaces. The team achieved its Go/No-Go milestone by exceeding the 25% energy-efficiency improvement target—reaching up to 3,340% under optimized conditions—and later confirmed that motor-driven systems offered superior performance and energy efficiency compared to piezoelectric alternatives. Continued refinement led to the development of amplifier systems on printed circuit boards, improved control and instrumentation hardware, and integration into full-scale heat exchanger (HX) prototypes at both UTS and Copeland facilities. Multiple vibration-mounting studies and frost-growth experiments guided mechanical optimization and noise-mitigation strategies, achieving a 17.5 dB reduction in sound pressure level and verifying robust mechanical performance. Advanced analyses, including modal and harmonic simulations, established a quantitative understanding of vibrational behavior and de-icing efficiency across >1000 cm² systems. The final project phase successfully demonstrated scalable integration within reach-in and chest freezer prototypes, confirmed >25% efficiency improvements in large-area systems, and completed a comprehensive business model and scale-up strategy identifying electric defrost systems as the primary beachhead market. The culmination of this DOE-supported effort establishes micro-vibrational defrosting as a viable, high-efficiency, low-noise, and demand-flexible de-icing technology, paving the way for commercial deployment and broader application in next-generation refrigeration systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Opportunities to Expand Building Efficiency Programming at Community Colleges

According to the most recent U.S. Energy and Employment Report, more than 2.3 million workers in the United States are involved in activities that reduce energy usage in buildings. This workforce supports energy efficiency from the design of buildings and their systems through the manufacturing and trade of components and supplies involved in these systems to the installation, repair, and maintenance of these systems. Less than 10% of the workers in key building efficiency occupations have a bachelor’s or higher degree, compared to ~40% of the general workforce. Thus, the community college system is a key stakeholder in training and educating a large portion of the building efficiency workforce. Despite this, the literature review conducted for this report found almost no research focused on better understanding and supporting the role of community colleges as they train this workforce at scale. This report seeks to understand how and to what extent building efficiency and advanced building technology concepts are being addressed in community colleges as well as potential pathways for schools to consider to better prepare students to enter the building efficiency industry. The first section presents information from a literature review and data analysis to provide background on the building efficiency workforce, the types of building efficiency training and education available from community colleges, and the barriers and challenges that exist in the workforce. The second section offers a series of case studies that illustrate the various ways that building efficiency content can be addressed at community colleges. The final section provides an overview of the opportunities available to community colleges as well as considerations for schools that want to increase building efficiency programming.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

A Tool to Incorporate Non-Energy Impacts in Energy Efficiency Investment Decision Making for Firms

Energy efficiency is a key demand-side strategy for sustainability, recently identified by the United States Department of Energy as a pillar of industrial decarbonization. The increased focus on decarbonization and the requirement for efficiency to enable electrification, another decarbonization pillar, due to the spark spread between natural gas and electricity prices, make energy efficiency increasingly relevant. Still, industries face challenges in adopting energy efficiency measures. Researchers have long found a gap in adoption of even those measures with a profitable net present value, attributed to lack of strategic value among other barriers (see for rigorous exploration and taxonomy). One solution to facilitate energy efficiency projects is the inclusion of non-energy impacts, as this has been shown to double potential deployment of such projects at system level. Energy efficiency can provide valuable benefits outside of simple operating cost reductions, from decreased pollution to enhanced productivity. The inclusion of these benefits in decision making assessments faces hurdles due to inconsistency of ancillary benefits across projects, difficulties in quantifying impacts and the need for additional measurement to quantify them. The decision-making tools to support this have been designed primarily for the European context. We begin with a stakeholder engagement process to better characterize the U.S. decision making process surrounding adoption of energy efficiency investments. Characterization of non-energy impacts has developed substantially over recent decades. Cagno et al. provided a framework for studying the applicability of these impacts to energy efficiency projects, listing 120 key performance indicators focused mainly on reductions of costs/harms. Other researchers have included impacts on the strategic and revenue side that can be merged into this framework as well. We seek a tractable set of impacts that can be included in a decision-making tool in the US, and as such are well suited to US industry, management and decision making processes. We also seek to understand how to best quantify or characterize these impacts. This work will demonstrate the results of a survey conducted among US manufacturing industry decision makers to assess the decision making landscape of stakeholders as well as the most relevant performance indicators for energy efficiency projects.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION,

An experimental and numerical investigation of HD diesel engine DOC efficiency in oxidizing NO to NO 2

Reducing pollutant emissions from heavy-duty (HD) diesel engines is critical due to their significant environmental impact, particularly concerning NOx emissions. Understanding and optimizing modern diesel oxidation catalyst (DOC) and selective catalytic reduction (SCR) performance is essential for improving exhaust aftertreatment (EAT) system efficiency to meet stringent emissions regulations. The oxidation of nitric oxide (NO) to nitrogen dioxide (NO 2 ) in DOC plays a key role in improving SCR efficiency in reducing NO x . This study investigates the DOC performance in oxidizing NO to NO2 and its impact on the SCR efficiency of a 2021 MY Navistar E39 HD diesel engine. The influence of engine speed, load, exhaust gas temperature, and composition on DOC efficiency is experimentally investigated. The relationships between DOC inlet temperature, oxygen availability and NO 2 /NO x ratio at the DOC inlet are examined to better understand their effects on the overall DOC efficiency. The results indicate that DOC NO oxidation efficiency is highly dependent on exhaust temperature, with optimal oxidation occurring within a specific temperature range (275-350°C). Below this threshold, the chemical reactions are kinetically limited, while at higher temperatures, thermodynamic constraints reduce the efficiency of DOC in oxidizing NO to NO 2 . The experimental data further reveal that the NO 2 /NO x ratio peaks at medium loads before declining at higher loads due to reduced residence time and mass transfer effects. Additionally, the SCR NO x conversion efficiency is significantly influenced by the NO 2 /NO x ratio, achieving peak performance when the NO 2 /NO x ratio approaches 0.5. A DOC chemistry model was developed and validated against the experimental data to predict DOC oxidation behavior under various operating conditions. The findings of this study provide insights into the interdependencies between DOC and SCR performance, contributing to the optimization of SCR systems for optimized NOx reduction.

33 ADVANCED PROPULSION SYSTEMS

High efficiency RF sources developments

Calabazas Creek Research, Inc. (CCR) and its collaborators are developing high efficiency RF sources operating from a few hundred MHz to C-Band and power levels from tens to hundreds of kilowatts with the goal of providing MW-relevant sources. The efficiencies approach or exceed 80% with projected costs as low as $0.50/ Watt. Sources under development include magnetrons with phase and amplitude control, single and multi-beam klystrons, multi-beam power grid tubes, and multiple beam IOTs. A magnetron system achieved more than 80% efficiency with fast amplitude control using modulation of the phase locking signal. This would be a low cost, high efficiency RF source for superconducting accelerators. An L-Band, single beam klystron was built with simulated efficiency of 80%. The klystron has yet to be tested to confirm the simulation results. CCR is currently developing a multi-beam klystron to produce more than 200 kW CW at 80% efficiency. Also in development is a multiple beam triode to produce 200 kW CW from 300 MHz to approximately 1 GHz. Not only does the simulated efficiency exceed 75%, but it would be the lowest cost RF source in this frequency range. Finally, CCR recently concluded research for a multiple beam IOT at 700 MHz using third harmonic drive to boost efficiency toward 85%. Successful development and transition to production of these sources will significantly alter the cost/performance landscape for RF power generation.

43 PARTICLE ACCELERATORS

Computational Analysis of Hydraulic Efficiency of Michigan DOT Covers J and K

Drainage structures are used in urban street and highway systems to capture stormwater runoff. These structures typically consist of catch basins fitted with grates, inlets, or combination grate/inlet configurations that collect runoff and convey it through buried drainage systems. They are strategically placed within curb-and-gutter systems to enhance public safety by efficiently removing water from roadways and thereby reducing the risk of hydroplaning. The performance of drainage structures is commonly evaluated in terms of hydraulic efficiency, defined as the percentage of flow captured by the basin relative to the total flow reaching the structure. Understanding the hydraulic performance of these structures allows designers to properly space inlets, resulting in cost-effective designs that also help ensure the safety of the traveling public. MDOT uses a variety of drainage structures for runoff capture, as documented in Michigan Department of Transportation (MDOT) Drainage Manual. Many of these structures incorporate sinusoidal-type grates that are not addressed in HEC-22. Because physical modeling of these structures has been limited, further analysis is needed to verify their capture efficiency. Under current MDOT practice, the capture efficiency of these grates is estimated by assuming performance similar to that of a comparably sized reticuline grate described in HEC22. The first phase of this effort, titled Computational Analysis of Hydraulic Efficiency of Michigan DOT Cover C, focused on evaluating the hydraulic performance of MDOT’s Cover C grate. Cover C was selected as the initial test candidate because its sinusoidal pattern is representative of other MDOT grates, while it is typically used in high-volume, higher-speed applications. A similar version, Cover CX, is used on interstate highways but does not include transverse bars for bicycle safety. The current second phase of the study expands this work to evaluate MDOT’s Covers J and K. These grates were selected for additional analysis to further assess the hydraulic performance of MDOT drainage structures that are not directly represented by grate configurations in HEC-22. The results of this phase will build on the findings from the Cover C analysis and support improved understanding of the capture efficiency of MDOT’s standard drainage grates. This report is intended to serve as a companion document to the earlier study, Computational Analysis of Hydraulic Efficiency of Michigan DOT Cover C [3]. The present work applies the same overall CFD-based evaluation approach to MDOT Covers J and K and compares the resulting performance trends with those previously identified for Cover C. In particular, both studies assess on-grade interception efficiency, sag-location hydraulic capacity, and the effects of partial obstruction relative to HEC-22-based design estimates.

42 ENGINEERING

High Efficiency Centrifugal Compressor for Rotorcraft Applications

The report "High Efficiency Centrifugal Compressor for Rotorcraft Applications" documents the work conducted at UTRC under the NRA Contract NNC08CB03C, with cost share 2/3 NASA, and 1/3 UTRC, that has been extended to 4.5 years. The purpose of this effort was to identify key technical barriers to advancing the state-of-the-art of small centrifugal compressor stages; to delineate the measurements required to provide insight into the flow physics of the technical barriers; to design, fabricate, install, and test a state-of-the-art research compressor that is representative of the rear stage of an axial-centrifugal aero-engine; and to acquire detailed aerodynamic performance and research quality data to clarify flow physics and to establish detailed data sets for future application. The design activity centered on meeting the goal set outlined in the NASA solicitation-the design target was to increase efficiency at higher work factor, while also reducing the maximum diameter of the stage. To fit within the existing Small Engine Components Test Facility at NASA Glenn Research Center (GRC) and to facilitate component re-use, certain key design parameters were fixed by UTRC, including impeller tip diameter, impeller rotational speed, and impeller inlet hub and shroud radii. This report describes the design effort of the High Efficiency Centrifugal Compressor stage (HECC) and delineation of measurements, fabrication of the compressor, and the initial tests that were performed. A new High-Efficiency Centrifugal Compressor stage with a very challenging reduction in radius ratio was successfully designed, fabricated and installed at GRC. The testing was successful, with no mechanical problems and the running clearances were achieved without impeller rubs. Overall, measured pressure ratio of 4.68, work factor of 0.81, and at design exit corrected flow rate of 3 lbm/s met the target requirements. Polytropic efficiency of 85.5 percent and stall margin of 7.5 percent were measured at design flow rate and speed. The measured efficiency and stall margin were lower than pre-test CFD predictions by 2.4 percentage points (pt) and 4.5 pt, respectively. Initial impressions from the experimental data indicated that the loss in the efficiency and stall margin can be attributed to a design shortfall in the impeller. However, detailed investigation of experimental data and post-test CFD simulations of higher fidelity than pre-test CFD, and in particular the unsteady CFD simulations and the assessment with a wider range of turbulence models, have indicated that the loss in efficiency is most likely due to the impact of unfavorable unsteady impeller/diffuser interactions induced by diffuser vanes, an impeller/diffuser corrected flow-rate mismatch (and associated incidence levels), and, potentially, flow separation in the radial-to-axial bend. An experimental program with a vaneless diffuser is recommended to evaluate this observation. A subsequent redesign of the diffuser (and the radial-to-axial bend) is also recommended. The diffuser needs to be redesigned to eliminate the mismatching of the impeller and the diffuser, targeting a slightly higher flow capacity. Furthermore, diffuser vanes need to be adjusted to align the incidence angles, to optimize the splitter vane location (both radially and circumferentially), and to minimize the unsteady interactions with the impeller. The radial-to-axial bend needs to be redesigned to eliminate, or at least minimize, the flow separation at the inner wall, and its impact on the flow in the diffuser upstream. Lessons were also learned in terms of CFD methodology and the importance of unsteady CFD simulations for centrifugal compressors was highlighted. Inconsistencies in the implementation of a widely used two-equation turbulence model were identified and corrections are recommended. It was also observed that unsteady simulations for centrifugal compressors require significantly longer integration times than what is current practice in industry.

Gorazd Medic

Efficiency droop contributors in InGaN green light emitting diodes

Here, efficiency droop contributors (i.e., inherent Auger–Meitner recombination, polarization-induced effects, thermal effects, and light extraction) in InGaN green light emitting diodes (LEDs) are decoupled and quantified. First, a modified ABC model is developed, and external quantum efficiency measurements are taken under constant and pulsed currents (⁠ EQE Constant and EQE Pulsed ⁠, respectively). The LED internal quantum efficiency with and without thermal effects (⁠ IQE$^{ABC}_{Constant}$ and IQE$^{ABC}_{Pulsed}$⁠, respectively) is extracted using the modified model. Then, using Raman spectroscopy, the LED junction temperature is extracted. Finally, using the optical-electrical model (OEM), the polarization- and temperature-independent LED internal quantum efficiency (⁠ IQE OEM ) is calculated from the modified ABC model and the extracted junction temperature. By comparing external (⁠ EQE Constant ⁠) and the three internal quantum efficiencies (⁠ IQE$^{ABC}_{Constant}$, IQE$^{ABC}_{Pulsed}$⁠, and IQE OEM ), the impacts of inherent Auger–Meitner recombination, polarization-induced effects, thermal effects, and light extraction on the efficiency droop are decoupled and quantified. It is found that inherent Auger–Meitner recombination-induced droop is approximately 49% of the total efficiency droop in commercial green LEDs, while polarization-induced effects contribute about 35%, and thermal droop accounts for nearly 16%. Lastly, these findings suggest, to quash the green gap, it is critical to search for materials and device designs with low inherent Auger–Meitner coefficients and polarization fields, respectively.

42 ENGINEERING