Search NASA⌕ Search

SEARCH · Search NASA

Results for “Elastic Recoil Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluating the diffusion of Kr in UO 2 and ADOPT TM using time-of-flight elastic recoil detection analysis (ToF-erda)

A combination of 300 keV 84 Kr ion implantation and Time-of-Flight Elastic Recoil Detection Analysis is utilized to investigate the diffusion of Kr in UO 2 and ADOPT TM fuels. Composition depth-profiles on the nanometer scale were obtained, both for as-implanted samples and after annealing at 800°C for 1 hour. Observed drifts in the 84 Kr profiles could be associated with short-range diffusion mechanisms. The approach employed here provides the possibility to make direct comparisons with atomistic scale modelling data, and can be of service as a separate effect test in line with the Accelerated Fuel Qualification initiative.

ADOPT UO2↗

Nuclear Microprobe using Elastic Recoil Detection (ERD) for Hydrogen Profiling in High Temperature Protonic Conductors

The interaction between hydrogen and various high temperature protonic conductors (HTPC) has not been clearly understood due to poor densification and unreacted secondary phases. the melt-processing technique is used in producing fully dense simple SrCe(0.9)Y (0.10) O(3-delta) and complex Sr3Ca(1+x)Nb(2+x)O(9-delta) perovskites that can not be achieved by solid-state sintering. the possibilities of ion beam analysis have been investigated to quantify hydrogen distribution in HTPC perovskites subjected to water heat treatment. Nuclear microprobe technique is based on the interactions of a focused ion beam of MeV light ions (H-1, H-2, He-3, He-4,.) with the sample to be analyzed to determine local elemental concentrations at the cubic micrometer scale, the elastic recoil detection analysis technique (ERDA) has been carried out using He-4(+) microbeams and detecting the resulting recoil protons. Mappings of longitudinal sections of water treated SrCeO3 and Sr(Ca(1/3)Nb(2/3))O3 perovskites have been achieved, the water treatment strongly alters the surface of simple SrCe(0.9)Y(0.10)O(3-delta) perovskite. From Rutherford Back Scattering measurements (RBS), both Ce depletion and surface re-deposition is evidenced. the ERDA investigations on water treated Sr3Ca(1+x)Nb(2+x)O(9-delta) perovskite did not exhibit any spatial difference for the hydrogen incorporation from the surface to the centre. the amount of hydrogen incorporation for Sr3Ca(1+x)Nb(2+x)O(9-delta) was low and required further development of two less conventional techniques, ERDA in forward geometry and forward elastic diffusion H-1(p,p) H-1 with coincidence detection.

Berger, Pascal↗

Development of eXternal Nuclear Reaction Analysis (XNRA) Detection Technique for Quantifying Light Isotope Concentrations

The National Nuclear Security Administration’s Tritium Sustainment Program is responsible for the design, development, demonstration, testing, analysis, and characterization of tritium-producing burnable absorber rods (TPBARs) and their components used to produce tritium for the nation’s strategic stockpile. The FY19 call for proposals included the specific basic science research topic, “Demonstration and evaluation of advanced characterization methods, particularly for quantifying the concentration of light isotopes ( 1 H, 3 H, 3 He, and 4 He, 6 Li and 7 Li) in metal or ceramic matrices”. Last year the same language appeared in the call for proposals, and a project IWO-389859 was awarded to the Ion Beam Lab (IBL) at Sandia-NM which was successful using Elastic Recoil Detection, but in the future could have resulted in tritium contamination that jeopardized other equally important NNSA projects. An alternative approach using deuterium nuclear reaction analysis was proposed and funded in FY2019 which was also successful and eliminated any possibility of contaminating the Ion Beam Laboratory with tritium, and will be described in this report.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of the microstructure of yttrium hydride under proton irradiation

High moderation per unit volume solid moderator materials like yttrium hydride (YH x ) are necessary for compact nuclear microreactors. However, the phase stability and hydrogen transport processes of YH x under high-temperature irradiation are largely unknown. Proton irradiation was conducted on YH x at 300 °C and 580 °C to 0.2 dpa using 1 MeV or 2 MeV protons in a high-vacuum environment. The hydrogen concentration was determined before and after irradiation using elastic recoil detection analysis, and microstructural evolution was examined via post-irradiation scanning transmission electron microscopy and Raman spectroscopy. Dislocation loops and cavities were observed in all conditions; their distribution was correlated with the bombarding proton energy and ion irradiation temperature. This work revealed that hydrogen retention is proportional to the formation of traps for hydrogen gas atoms and identified pathways for hydrogen release. The relative contributions of bulk or fast diffusion paths, such as grain boundaries, delamination boundaries, and stacking faults are discussed; the primary mechanisms of hydrogen loss are likely based on diffusion, ruling out artefacts of the experimental design. In conclusion, the study suggests proton irradiation may be a strong surrogate to study hydrogen transport in hydride moderator materials under irradiation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hollow-cathode chemical vapor deposition of thick, low-stress diamond-like carbon films

A radio-frequency (RF), hollow-cathode plasma source with confining magnetic field is described for the chemical vapor deposition of thick ( > 10 µm), amorphous diamond-like carbon ablator films for inertial confinement fusion applications. Plasma is characterized by optical emission spectroscopy, while properties of the resultant films are measured by a combination of profilometry, Rutherford backscattering spectrometry, elastic recoil detection analysis, X-ray diffraction, Raman spectroscopy, and atomic force microscopy. The dependence of the deposition rate, film density, elemental composition, self-bias and residual stress is reported as a function of RF power. Higher density films were found when using Ar plasma, than N 2 or H 2 plasma. The coatings produced are x-ray amorphous, exhibit low compressive stress ( ~ 100 MPa), high density ( < 1.7 g/cm 3 ), hydrogen content of ~ 30 at.%, and a low average roughness of 0.75 nm. Finally, applications of these films as tunable-density ablators for inertial confinement fusion experiments are discussed.

36 MATERIALS SCIENCE↗

Multiscale Investigation of the Mechanisms Controlling the Corrosion of Borosilicate Glasses in Hyper-Alkaline Media

The overarching goal of the present multiscale investigation is to unearth the kinetics and mechanisms of corrosion of borosilicate glasses in hyper-alkaline (pH = 13) environments as a function of their chemical composition. Accordingly, a series of 3- to 6-component borosilicate glasses have been designed starting from Na 2 O–B 2 O 3 –SiO 2 ternary, wherein the compositional complexity has been added in a systematic tiered approach, finally resulting in the composition of the well-known international simple glass (ISG). Tetramethylammonium hydroxide (TMAH), one of the most widely used alkaline etchant in the glass and electronics industry, has been used as the corrosion media. A series of state-of-the-art characterization techniques including magic angle spinning nuclear magnetic resonance spectroscopy, X-ray photoelectron spectroscopy, inductively coupled plasma optical emission spectroscopy, elastic recoil detection analysis, and high-resolution transmission electron microscopy have been employed to unearth the compositional dependence of glass corrosion in hyper-alkaline environments. The glass compositions underwent congruent corrosion in the forward rate regime, whereas the controlling mechanism of corrosion in the residual rate regime depends on the presence/absence of Ca in the surrounding environment and can be explained on the basis of the dissolution–reprecipitation model. The dependence of corrosion kinetics and the chemistry of alteration products (in the residual rate regime) on the glass composition have been discussed. Here, the results presented in this contribution will ultimately supplement the scientific literature attempting to understand the fundamental science governing the aqueous corrosion of silicate-based glass chemistries and add to the growing database required to develop non-empirical predictive models for designing glasses with controlled dissolution rates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects of Surface Treatments on Secondary Electron Emission from CVD Diamond Films

Secondary electron emission (SEE) properties of polycrystalline diamond films grown by chemical vapor deposition (CVD) were measured. The total secondary yield (sigma) from as-grown samples was observed to be as high as 20 at room temperature and 48 while heating at 700 K in vacuum. Electron-beam-activated, alkali-terminated diamond films have shown stable values of sigma as high as 60 when coated with CsI and similarly high values when coated with other alkali halides. Diamond coated with BaF2 had a stable sigma of 6, but no enhancement of the SEE properties was observed with coatings of Ti or Au. Hydrogen was identified to give rise to this effect in as-grown films. However, electron beam exposure led to a reduction in sigma values as low as 2. Exposure to a molecular hydrogen environment restored sigma to its original value after degradation, and enabled stable secondary emission during electron beam exposure. Atomic hydrogen and hydrogen plasma treatments were performed on diamond/Mo samples in an attempt to increase the near-surface hydrogen concentration which might lead to increased stability in the secondary emission. Raman scattering analysis, scanning electron microscopy, and Auger electron spectroscopy (AES) confirmed that hydrogen plasma and atomic hydrogen treatments improved the quality of the CVD diamond significantly. Elastic recoil detection (ERD) showed that heating as-grown diamond targets to 7OO K, which was correlated with an increase in sigma, removed contaminants from the surface but did not drive hydrogen from the diamond bulk. ERD showed that the hydrogen plasma treatment produced an increase in the hydrogen concentration in the near-surface region which did not decrease while heating in vacuum at 700 K, but no improvement in the SEE properties was observed.

Mearini, G. T.↗

Passive Low-Energy Nuclear-Recoil Detection with Color Centers

Crystal-damage events such as tracks and point defects have been used to record and detect radiation for a long time and recently they have been proposed as a means for dark-matter detection. Color centers can be read out optically and we propose a scheme based on selective plane illumination microscopy for micrometer-scale imaging of large volumes corresponding to kilogram mass detectors. This class of detectors would be passive and would operate at room temperature and we call this the passive low-energy optical color-center nuclear-recoil (PALEOCCENE) detection method. We apply these concepts to the detection of reactor neutrinos using coherent elastic neutrino nucleus scattering (CE ν NS). Crystal-damage formation energies are intrinsically on the order of 25 eV, resulting in similarly low nuclear-recoil thresholds. Furthermore, this would enable the observation of reactor-neutrino CE ν NS with detectors as small as 10 g. Additionally, a competitive search for spin-dependent dark-matter scattering down to a dark-matter mass of 0.3 GeV could be possible. Passive crystal detectors might also be attractive for nuclear-nonproliferation safeguards if used to monitor reactor power and to put limits on plutonium production. The passive nature and small footprint of the proposed detectors implies that these might fit well within accepted reactor-safeguards operations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Control of the Plasma-Material Interface for Long Pulse Optimization in EAST and KSTAR

This project's major goal was to understand and control the plasma-material interface to improve long pulse discharge and performance in the EAST and KSTAR devices, emphasizing the unique strengths of each machine. In particular, MIT has developed implanted depth markers to diagnose the net erosion of high-Z materials. The goals included the characterization and utilization of these markers in various high-Z materials of interest, including TZM, tungsten, and refractory metal base high entropy alloys.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Benchmarking of a Proton Recoil Neutron Detector

A neutron spectroscopy detector was designed for analysis of neutrons produced by Lawrence Livermore National Laboratory's neutron imaging project. The detector was built and benchmarked at Lawrence Berkeley National Laboratory's Deuteron-Breakup Neutron Facility. Similar to a proton-recoil telescope, the setup detects protons elastically scattered from neutrons incident on a thin sheet of polyethylene. A silicon charged-particle detector several centimeters away detects the protons in a small angular range, such that the energies of the incident neutrons can be reconstructed from the energy of the detected proton and the scattering angle. A quick benchmarking experiment demonstrated that large backgrounds would be a significant challenge, and that additional measures must be taken to reduce these backgrounds. A Geant4 model of the detector was used to predict the sources of these backgrounds and how best to reduce them.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of Ionization Produced by 254 eVnr Nuclear Recoils in Germanium

Ionization produced by low-energy nuclear recoils is among the primary direct signatures of dark matter interactions. Despite the urgency of dark matter detection and the recent measurements of coherent elastic neutrino-nucleus scattering, detector response to nuclear recoils is not well characterized in the keVnr and sub-keVnr regime across a variety of materials. We have re-performed a measurement of the ionization produced by monoenergetic 254 eVnr nuclear recoils in Ge with improved digital electronics and additional systematic studies. Our results indicate an ionization yield of 64 +/- 8 eVee corresponding to a quenching factor of 25 +/- 3%, greater than the 14% predicted by the Lindhard model. This ionization enhancement could greatly improve the sensitivity of high-purity Ge detectors in dark matter detection and measurement of neutrinos via coherent scattering.

Kavner, Alexander R.↗

Constraints on directionality effect of nuclear recoils in a liquid argon time projection chamber

The direct search for dark matter in the form of weakly interacting massive particles (WIMP) is performed by detecting nuclear recoils produced in a target material from the WIMP elastic scattering. The experimental identification of the direction of the WIMP-induced nuclear recoils is a crucial asset in this field, as it enables unmistakable modulation signatures for dark matter. The Recoil Directionality (ReD) experiment was designed to probe for such directional sensitivity in argon dual-phase time projection chambers (TPC), that are widely considered for current and future direct dark matter searches. The TPC of ReD was irradiated with neutrons at the INFN Laboratori Nazionali del Sud. Data were taken with nuclear recoils of known directions and kinetic energy of 72 keV, which is within the range of interest for WIMP-induced signals in argon. The direction-dependent liquid argon charge recombination model by Cataudella et al. was adopted and a likelihood statistical analysis was performed, which gave no indications of significant dependence of the detector response to the recoil direction. The aspect ratio R of the initial ionization cloud is $R < 1.072$ with 90 % confidence level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutrino constraints on inelastic dark matter captured in the Sun

Abstract The flux of neutrinos from annihilation of gravitationally captured dark matter in the Sun has significant constraints from direct-detection experiments. However, these constraints are relaxed for inelastic dark matter as inelastic dark matter interactions generate less energetic nuclear recoils compared to elastic dark matter interactions. In this paper, we explore the possibility for large volume underground neutrino experiments to detect the neutrino flux from captured inelastic dark matter in the Sun. The neutrino spectrum has two components: a mono-energetic “spike” from pion and kaon decays at rest and a broad-spectrum “shoulder” from prompt primary meson decays. We focus on detecting the shoulder neutrinos from annihilation of hadrophilic inelastic dark matter with masses in the range 4–100 GeV and the mass splittings in up to 300 keV. We determine the event selection criterion for DUNE to identify GeV-scale muon neutrinos and anti-neutrinos originating from hadrophilic dark matter annihilation in the Sun, and forecast the sensitivity from contained events. We also map the current bounds from Super-Kamiokande and IceCube on elastic dark matter, as well as the projected limits from Hyper-Kamiokande, to the parameter space of inelastic dark matter. We find that there is a region of parameter space that these neutrino experiments are more sensitive to than the direct-detection experiments. For dark matter annihilation to heavy-quarks, the projected sensitivity of DUNE is weaker than current (future) Super (Hyper) Kamiokande experiments. However, for the light-quark channel, only the spike is observable and DUNE will be the most sensitive experiment.

Astronomy & Astrophysics↗

Experimental Investigation and Monte Carlo Simulation of Quasielastic Electron Scattering From Helium-3 Clusters in Helium-4

Experiment E04-018 was conducted in Hall A of the Jefferson National Laboratory (JLab) from November 2006 through July 2007. The experiment used the two superconducting, high-resolution magnetic spectrometers of Hall A to detect scattered electrons and recoil nuclei. One goal of this experiment was to provide accurate data on the elastic charge form factor of 4He to high momentum transfers (up to Q2 = 77 fm?2). The purpose of this thesis is to analyze and simulate a very unique and unexpected class of data from this experiment. The work performed involved the analysis of electron scattering data with the 4He target of the JLab E04-018 experiment and Monte Carlo simulation studies of elastic and quasielastic electron scattering from the 4He and 3He few-body nuclear systems. The results of this experiment and the simulations provide insights into the existence of A = 3 clustering in 4He, and possibly in heavier nuclei.

Alahmade, Walaa↗

Scintillating Bubble Chambers for Rare Event Searches

The Scintillating Bubble Chamber (SBC) collaboration is developing liquid-noble bubble chambers to detect sub-keV nuclear recoils, allowing the search for low-mass (GeV-scale) dark matter and coherent elastic neutrino-nucleus scattering from low-energy (MeV-scale) neutrinos. The scintillating bubble chamber detectors benefit from the energy reconstruction that the scintillation signal gives in addition to the superior electron-recoil insensitivity that bubble chambers naturally provide. The high level of superheat achievable in noble liquids while being electron-recoil insensitive allows for lower nuclear recoil thresholds than in existing freon-based bubble chambers, potentially reaching the 100 eV threshold desired for reactor CEvNS measurements. To validate this lower threshold, the SBC collaboration is constructing two 10 kg detectors that are functionally identical. The SBC-LAr10, which is being commissioned at Fermilab, is intended for engineering and calibration research and has additional possibilities in assessing coherent elastic neutrino-nucleus scattering in argon. SBC-SNOLAB, the second detector for a low-background dark matter search, will be run at SNOLAB underground.

Pyda, Daniel [Unlisted, US]↗

Properties of states near 𝐸 𝑥 = 6 MeV in 18 Ne through 17 F +𝑝 scattering

The rate of energy production in the hot-CNO cycle and breakout to the rapid-proton capture process in Type I X-ray bursts is strongly related to the 14 O⁡(𝛼,𝑝)⁢ 17 F reaction rate. The properties of states in 18 Ne near 𝐸 𝑥 = 6.1–6.3 MeV are important for understanding the 14 O⁡(𝛼,𝑝)⁢ 17 F reaction rate. In order to study 18 Ne resonances around this energy region, the RESOLUT radioactive-ion beam facility at Florida State University was used to perform 17 F⁡(𝑝,𝑝)⁢ 17 F elastic scattering on a polypropylene target under inverse kinematics. Scattered protons were detected in a silicon-strip detector array while recoiling 17 F ions were detected in coincidence in a gas ionization detector. An 𝑅-matrix analysis of measured cross sections was conducted along with a reanalysis of data from previous 17 F +𝑝 measurements. All the data analyzed are well described by a consistent set of parameters with a 1 − assignment for a state at 6.14(1) MeV. A second comparable solution is also found with a 3 − assignment for the 6.14(1) MeV state. There is no conclusive evidence supporting one of the two solutions over the other. The rates of the 14 O⁡(𝛼,p)⁢ 17 F reaction that are determined from the two solutions differ by up to an order of magnitude.

6 ≤ A ≤ 19↗

Measuring recoiling nucleons from the nucleus with the future Electron Ion Collider

Short range correlated nucleon-nucleon (NN) pairs are an important part of the nuclear ground state. They are typically studied by scattering an electron from one nucleon in the pair and detecting its spectator correlated partner (spectator-nucleon tagging). The Electron Ion Collider (EIC)should be able to detect these nucleons, since they are boosted to high momentum in the lab frame by the momentum of the ion beam. To determine the feasibility of these studies with the planned EIC detector configuration, we have simulated quasi-elastic scattering for two electron and ion beam energy configurations: 5 GeV electrons and 41 GeV/A ions, and 10 GeV electrons and 110 GeV/A ions. We show that the knocked-out and recoiling nucleons can be detected over a wide range of initial nucleon momenta. We also show that these measurements can achieve much larger momentum transfers than current fixed target experiments. By detecting both low and high initial-momentum nucleons,the EIC will provide the data that should allow scientists to definitively show if the EMC effect and short-range correlation are connected, and to improve our understanding of color transparency

Hauenstein, F. (ORCID:0000000212652212)↗