Static Analysis of the Lumped Mass Cable Model Using a Shooting Algorithm

This paper focuses on a method to solve the static configuration for a lumped mass cable system. The method demonstrated here is intended to be used prior to performing a dynamics simulation of the cable. Conventional static analysis approaches resort to dynamics relaxation methods or root-finding algorithms (such as the Newton-Raphson method) to find the equilibrium profile. The alternative method demonstrated here is general enough for most cable configurations (slack or taut) and ranges of cable elasticity. The forces acting on the cable are attributable to elasticity, weight, buoyancy, and hydrodynamics. For the three-dimensional problem, the initial cable profile is obtained by solving three equations, regardless of the cable discretization resolution. This analysis discusses regions and circumstances under which failures in the method are encountered.

16 TIDAL AND WAVE POWER↗

Determining Remaining Useful Life of Aging Cables in Nuclear Power Plants – Interim Study FY13

The most important criterion for cable performance is its ability to withstand a design-basis accident. With nearly 1000 km of power, control, instrumentation, and other cables typically found in an NPP, it would be a significant undertaking to inspect all of the cables. Degradation of the cable jacket, electrical insulation, and other cable components is a key issue that is likely to affect the ability of the currently installed cables to operate safely and reliably for another 20 to 40 years beyond the initial operating life. The development of one or more nondestructive evaluation (NDE) techniques and supporting models that could assist in determining the remaining life expectancy of cables or their current degradation state would be of significant interest. The ability to nondestructively determine material and electrical properties of cable jackets and insulation without disturbing the cables or connections has been deemed essential. Currently, the only technique accepted by industry to measure cable elasticity (the gold standard for determining cable insulation degradation) is the indentation measurement. All other NDE techniques are used to find flaws in the cable and do not provide information to determine the current health or life expectancy. There is no single NDE technique that can satisfy all of the requirements needed for making a life-expectancy determination, but a wide range of methods have been evaluated for use in NPPs as part of a continuous evaluation program. The commonly used methods are indentation and visual inspection, but these are only suitable for easily accessible cables. Several NDE methodologies using electrical techniques are in use today for flaw detection but there are none that can predict the life of a cable. There are, however, several physical and chemical ptoperty changes in cable insulation as a result of thermal and radiation damage. In principle, these properties may be targets for advanced NDE methods to provide early warning of aging and degradation. Examples of such key indicators include changes in chemical structure, mechanical modulus, and dielectric permittivity. While some of these indicators are the basis of currently used technologies, there is a need to increase the volume of cable that may be inspected with a single measurement, and if possible, to develop techniques for in-situ inspection (i.e., while the cable is in operation). This is the focus of the present report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Solution and sensitivity analysis of nonlinear equations using a hypercomplex-variable Newton-Raphson method

Here, the classical Newton-Raphson (NR) method for solving nonlinear equations is enhanced in two ways through the use of hypercomplex variables and algebra. In particular, i) the Jacobian is computed in a highly accurate and automated way, and ii) the derivative of the solution to the nonlinear equations is computed with respect to any parameter contained within the system of equations. These advances provide two significant enhancements in that it is straightforward to provide an accurate Jacobian and to construct a reduced order model (ROM) of arbitrary order with respect to any parameter of the system. The ROM can then be used to approximate the solution for other parameter values without requiring additional solutions of the nonlinear equations. Several case studies are presented including 1D and 2D academic examples with fully functioning Python code provided. Additionally, a case of study of the catenary of an elastic cable subject to its own weight and a vertical point load. Derivatives up to 10th order were computed with respect to material, loading, and geometrical parameters. The derivatives were used to generate reduced order models of the cable deformation and reaction forces at its ends with respect to multiple input parameters. Results show that from a single hypercomplex evaluation of the cable under a single vertical point load, it is possible to generate an accurate reduced order model capable of predicting the cable deformation with 1.5 times the load in the opposite direction and with 3.5 times the load in the same direction without resolving the system of equations.

97 MATHEMATICS AND COMPUTING↗

New Technologies for Repairing Aging Cables in Nuclear Power Plants

The goal of this project is to demonstrate a proof-of-concept for a technique to repair aging cables that have been subjected to degradation associated with long-term thermal and radiation exposure in nuclear power plants. The physical degradation of the aging cables manifests itself primarily as cracking and increased brittleness of the polymeric electrical insulation. Therefore, the proposed cable-repair concept comprises development of techniques to impart a softening agent within the deteriorated polymer insulation jacket so as to regain the ability of the insulation to stretch without failing and possibly to heal existing cracks in the insulation. Our approach is to use commercially available ethylene-propylene rubber (EPR) as the relevant test material, demonstrate the adsorption of chemical treatments in the EPR and quantify changes in resulting physical and mechanical properties. EPR cable samples have been thermally treated in air to produce specimens corresponding to the full range of cable age-performance points from new (>350% elongation at break) to end-of-life (<50% elongation at break). The current focus is on two chemical treatments selected as candidates for restoring age-related cable elasticity loss: a rubber plasticizer and a reactive silane molecule. EPR specimens of 200, 150, 100, and 50% elongation at break have been soaked in the candidate chemical treatments and the kinetics of chemical uptake, measured by change in mass of the samples, has been determined. Mechanical properties as a function of aging and chemical treatment have been measured including ultimate tensile strength, tensile modulus at 50% strain, elongation at break, and storage modulus. Dimensional changes with treatment and changes in glass transition temperature were also investigated. These ongoing experiments are expected to provide insight into the physical-chemical nature of the effect of thermal degradation on EPR rejuvenation limits and to advance novel methods for restoring the ability of degraded EPR to be compliant and resist fracture. The results of this research reveal that absorption of chemical treatments can lower the glass transition temperature and modulus of EPR. Chemical treatments pursued thus far have proven ineffective at restoring EPR strength and elongation at break. Future work will combine the plasticizer modalities found to successfully increase the volume of the EPR, reduce EPR glass transition temperature and reduce EPR modulus with promising chemistries that will repair the damage of the polymer, potentially using the plasticizer as a host for the new chemistry.

36 MATERIALS SCIENCE↗

First Principles Model of Electric Cable Braid Penetration with Dielectrics

In this study, we report the formulation to account for dielectrics in a first principles multipole-based cable braid electromagnetic penetration model. To validate our first principles model, we consider a one-dimensional array of wires, which can be modeled analytically with a multipole-conformal mapping expansion for the wire charges; however, the first principles model can be readily applied to realistic cable geometries. We compare the elastance (i.e. the inverse of the capacitance) results from the first principles cable braid electromagnetic penetration model to those obtained using the analytical model. The results are found in good agreement up to a radius to half spacing ratio of 0.5-0.6, depending on the permittivity of the dielectric used, within the characteristics of many commercial cables. We observe that for typical relative permittivities encountered in braided cables, the transfer elastance values are essentially the same as those of free space; the self-elastance values are also approximated by the free space solution as long as the dielectric discontinuity is taken into account for the planar mode.

42 ENGINEERING↗

Coaxial printing method for directly writing stretchable cable as strain sensor

Through applying the liquid metal and elastomer as the core and shell materials, respectively, a coaxial printing method is being developed in this work for preparing a stretchable and conductive cable. When liquid metal alloy eutectic Gallium-Indium is embedded into the elastomer matrix under optimized control, the cable demonstrates well–posed extreme mechanic performance, under stretching for more than 350%. Under developed compression test, the fabricated cable also demonstrates the ability for recovering original properties due to the high flowability of the liquid metal and super elasticity of the elastomeric shell. The written cable presents high cycling reliability regarding its stretchability and conductivity, two properties which can be clearly predicted in theoretical calculation. This work can be further investigated as a strain sensor for monitoring motion status including frequency and amplitude of a curved object, with extensive applications in wearable devices, soft robots, electronic skins, and wireless communication.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Piston cylinder cell for high pressure ultrasonic pulse echo measurements

Ultrasonic techniques such as pulse echo, vibrating reed, or resonant ultrasound spectroscopy are powerful probes not only for studying elasticity but also for investigating electronic and magnetic properties. Here, we report on the design of a high pressure ultrasonic pulse echo apparatus, based on a piston cylinder cell, with a simplified electronic setup that operates with a single coaxial cable and requires sample lengths of mm only. The design allows simultaneous measurements of ultrasonic velocities and attenuation coefficients up to a pressure of 1.5 GPa. We illustrate the performance of the cell by probing the phase diagram of a single crystal of the ferromagnetic superconductor UGe{sub 2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multipole-Based Cable Braid Electromagnetic Penetration Model: Electric Penetration Case

In this paper, we investigate the electric penetration case of the first principles multipole-based cable braid electromagnetic penetration model reported in the Progress in Electromagnetics Research B 66, 63–89 (2016). We first analyze the case of a 1-D array of wires: this is a problem which is interesting on its own, and we report its modeling based on a multipole-conformal mapping expansion and extension by means of Laplace solutions in bipolar coordinates. We then compare the elastance (inverse of capacitance) results from our first principles cable braid electromagnetic penetration model to that obtained using the multipole-conformal mapping bipolar solution. These results are found in a good agreement up to a radius to half spacing ratio of 0.6, demonstrating a robustness needed for many commercial cables. We then analyze realistic cable implementations without dielectrics and compare the results from our first principles braid electromagnetic penetration model to the semiempirical results reported by Kley in the IEEE Transactions on Electromagnetic Compatibility 35, 1–9 (1993). Finally, although we find results on the same order of magnitude of Kley's results, the full dependence on the actual cable geometry is accounted for only in our proposed multipole model which, in addition, enables us to treat perturbations from those commercial cables measured.

42 ENGINEERING↗

Distributed fiber optic strain sensing of bending deformation of a well mockup in the laboratory

Well integrity is critical to the safety and success of subsurface energy exploration and management, as leakage of fluids from subsurface reservoirs is often induced by compromised wells. This study investigates bending deformation of a mockup of an oil/gas well that is subjected to loads expected in deviated wells under reservoir compaction and assesses the feasibility of utilizing distributed fiber optic strain sensing to monitor the deformation. Here, a well mockup, which consists of outer and inner steel pipes with a cemented annulus, is tested under three-point bending loading and its strain and curvature development is monitored by Brillouin optical time domain reflectometry/analysis (BOTDR/A) as well as optical frequency domain reflectometry (OFDR). The primary objective of this research is to assess the strain sensing performance of newly fabricated fiber optic cables and to identify key cable characteristics which could improve the quality of distributed strain measurements with BOTDR/A. Results show that the tight-buffered cable is best suited for strain sensing as its maximum errors in the strain measurement were -36% and -24% against conventional sensors at the maximum elastic and plastic bending loads, respectively, whereas those of the non-tight-buffered cable were -45% and -71%, respectively. Similar trends were obtained in the bending curvature measurement. The detailed design of the tight-buffered cable is presented to elucidate key characteristics of such a cable, which will facilitate accurate distributed strain sensing in oil and gas wells.

42 ENGINEERING↗

Implementation and Verification of Cable Bending Stiffness in MoorDyn

The relatively large motions experienced by floating wind turbines and wave energy converters pose a challenge for power cables, whose internal components provide significant bending resistance and are sensitive to deformation. The behavior and associated design considerations of power cables in these highly dynamic applications make coupled analysis relevant for design. Bending stiffness capabilities have recently been added to the lumped-mass mooring dynamics model MoorDyn to enable simulation of dynamic power cables. MoorDyn is a common modeling choice for floating wind energy simulation (often coupled with OpenFAST) and floating wave energy converter simulation (often coupled with WEC-Sim) but the model’s previous line elasticity formulation only considered axial stiffness. To properly capture the dynamics of power cables, a bending stiffness model has been added that approximates cable curvature based on the difference in tangent vectors of adjacent elements. The resulting bending moment is realized by applying forces on adjacent nodes, enabling cable modeling while leaving the underlying lumped-mass formulation unchanged. In this paper, the new bending stiffness implementation is verified in static conditions against analytical solutions and then in a dynamic power cable scenario in comparison with the commercial simulator OrcaFlex. The dynamic scenario uses prescribed motions and includes wave loadings on the cable. Results indicate correct implementation of bending stiffness and show close agreement with OrcaFlex.

50 EE - Wind and Water Power Program - Water (EE-4↗

Implementation and Verification of Cable Bending Stiffness in MoorDyn: Preprint

Cable bending stiffness capabilities have been added to MoorDyn to enable modeling of dynamic power cables. The relatively large motions experienced by floating wind turbines and wave energy converters pose a challenge for power cables, whose internal components provide significant bending resistance and are sensitive to deformation. The behavior and associated design considerations of power cables in these highly dynamic applications make coupled analysis relevant for design. MoorDyn is a lumped-mass mooring dynamics model that is used for floating wind energy simulation (often coupled with OpenFAST) and floating wave energy converter simulation (often coupled with WEC-Sim). Its existing line elasticity formulation considers axial stiffness only. To properly capture the dynamics of power cables, a cable bending stiffness model has been added that approximates cable curvature based on the difference in tangent vectors of adjacent line elements. The resulting bending moment is realized by applying forces on adjacent nodes, leaving the underlying lumped-mass formulation unchanged. The bending stiffness implementation is verified in static conditions against analytical solutions and then in a dynamic power cable scenario in comparison with OrcaFlex. The dynamic scenario uses prescribed motions and includes wave loadings on the cable. Results indicate correct implementation of bending stiffness and show close agreement with OrcaFlex.

50 EE - Wind and Water Power Program - Water (EE-4↗

Experimental Investigation of Low-Frequency Distributed Acoustic Strain-Rate Responses to Propagating Fractures

Summary Low-frequency distributed acoustic sensing (LF-DAS) responds to strain changes due to far-field fracture propagation. To better understand the LF-DAS response to fracture propagation, we performed laboratory-scale hydraulic fracture experiments with embedded optical strain sensors. The objectives of this research are to generate hydraulic fractures of known geometry, measure the strain response along the embedded fiber-optic cable comparable to LF-DAS measurements, and use the results to inform the interpretation of field-derived LF-DAS data. The experiments were conducted in unconfined transparent cubic blocks with a dimension of 8 in. on each side. The block was made of transparent epoxy to visualize the fracture propagation. Fiber-optic sensing cables were embedded in the block at different distances to the source of injection. We injected dyed water through an injection tubing to generate a transverse, radial fracture along an initial flaw. An optical interrogator recorded the response of offset fiber Bragg grating (FBG) strain sensors normal to the plane of the fracture. The strain data were visualized on a waterfall plot, akin to visualizations of field-derived LF-DAS data. Dimensional analysis was used to scale the laboratory results to field conditions. We compared the evolution of the strain response at the fiber-optic cable, injection pressure, and rate with known fracture geometry. The measured strains were compared with Sneddon’s (1946) linear elastic solution for a penny-shaped crack and found to follow this behavior. The generated radial fractures in transparent media can be modeled with Sneddon’s linear elastic radial fracture model and a Mode I critical stress intensity factor. The LF-DAS characteristic response of a narrowing region of extension surrounded by compression was exhibited as a fracture that approached and intersected the fiber-optic cable. The experimentally derived strain and strain-rate waterfall plots with known fracture geometry, injection rate, and pressure response provide insight in understanding LF-DAS responses in the field. Furthermore, we developed a method to estimate fracture geometry evolution from the fiber-optic strain data and validated the method against the experimental data.

Engineering↗

Engineering Considerations for Remote Refabrication of EBR-II Fuel Elements

The development of remote controlled methods for manufacturing EBR-II fuel elements was influenced by many interacting factors. Radiation levels within the process cell have been predicted to range from 10 3 to 10 7 rad per hour. Radiation damage to organic lubricant, electrical insulations, elastic seals, and protective coatings precludes the use of many standard machine components. Heat generated in the fuel by absorbed radiation makes forced cooling necessary in many operations. Oxygen must be exluded from all operations where the fuel is exposed. Equipment must be designed for remote maintenance and component replacement within the limitation of available manipulators. The EBR-II fuel consisted of fissium alloy pins sodium bonded in stainless steel tubes. Precision casting was chosen as the basis for refabricating the fuel pins. Remote controlled equipment was developed to cast, assemble, and inspect the EBR-II fuel elements. Radiation resistant, plug-in machine components were developed to give reasonable life expectancy and to allow remote maintenance and replacement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Introduction of Nonlinear Properties Into Hierachical Models of Nb3Sn Strands

The development of computational models representing Rutherford cable formation and deformation is necessary to investigate the strain state in the superconducting filaments in Nb{sub 3}Sn magnets. The wide variety of length scales within accelerator magnets suggests usage of a hierarchical structure within the model. As part of an ongoing investigation at LBNL, a three-dimensional simplified nonlinear multiscale model is developed as a way to extend previous linear elastic versions. The inclusion of plasticity models into the problem formulation allows an improved representation of strand behavior compared to the linear elastic model. This formulation is applied to a single Nb{sub 3}Sn strand to find its effective properties as well as the strain state in the conductor under loading.

43 PARTICLE ACCELERATORS↗

Quantifying Properties for a Mechanistic, Predictive Understanding of Aqueous Impact on Aging of Medium and Low Voltage AC and DC Cabling in Nuclear Power Plants

To address the gap in knowledge in understanding degradation in relevant service conditions, this project aimed to develop a mechanistic, predictive model of medium and low voltage cable failure based on the primary environmental degradation parameters of aqueous immersion time, temperature, and the oxidation extent. To do so, we took a two-fold approach toward evaluating degradation as related to the aqueous condition. First, we evaluated the chemical, mechanical, and electrical properties of polymers that comprise the cabling insulation under varied aqueous conditions at different temperatures. Secondly, we evaluated the performance of insulation materials under similar accelerated aging conditions in addition to the dielectric breakdown of the cabling under submersion conditions. Thermal oxidation and immersion of LDPE thin films were done using a Parr vessel and the extent of oxidation was monitored using the carbonyl index from ATR-FTIR spectrum, a ratio quantifying the carbonyl functionality produced on the LDPE film surface. Increasing the temperature, oxidation time, and oxygen pressure increased the water-vapor permeability and the carbonyl content. Thermogravimetric analysis of the films confirmed that there is indeed an initial weight loss of the smaller molecular weight molecules and volatiles. At higher temperatures, there is a secondary mass loss. Up to 70°C, the mass loss curves were similar until 80°C, when the aged films decreased at a much greater rate with respect to increasing temperature. This was seen in the 10, 50, 90% weight loss temperatures. The mechanical properties of sheet PP and HDPE as well as injection molded LDPE, HDPE, HDPP dog bones were plotted with respect to the time spent in the Parr vessel during thermal oxidation. For the sheet PP and HDPE, the UTS and the modulus of elasticity decreased while the elongation increased. The injection-molded LDPE, HDPE, and HDPP dog bones experienced a similar trend where the changes in the properties were within experimental uncertainty. This analysis of LDPE in dry and immersive oxygen-rich environments is an important baseline for future experiments looking at other degradation mechanisms. A predictive aging model for low-density polyethylene insulative cable housings was developed. This model revealed a combination of physical and chemical processes which lead to an increase in permeability and a decrease in strength of the insulator. In creating this predictive model, a gap of knowledge in the literature was revealed in two areas: understanding how the crystallinity of a polymer changes with time and visualizing the predicted pores formed through the insulator which leads to failure. Developing and using an adapted ATR-FTIR method, crystallinity was monitored and compared to bulk crystallinity found via DSC. Inhomogeneity in crystallinity changes were observed but the FTIR method but was found to be less reliable. Pore visualization was found utilizing electrical impedance spectroscopy saturated aged polyethylene films with synthesized citrate-capped gold nanoparticles, and chloroauric acid precursor. results indicate a decreasing impedance of the polyethylene films caused by the transport of ions through the film. SEM imaging was then performed for elemental analysis of the films and counter electrodes for the presence of ions. Chloride and gold ions were detected; however, no nanoparticles were found. This gives an estimated pore size of at least 0.3 nm through the aged film. Cyclic submergence of polyethylene and polypropylene in aqueous solutions of copper sulfate and Harrison’s solution were examined. It was discovered that aging in these mixed conditions and at 90°C did cause a small, yet significant increase to tensile strength for both unaged polyethylene and polypropylene. The PE and PP in cycled and submerged conditions did not have tensile strengths significantly different from dry-aged after 16 weeks. For both solutions, it was determined that capacitance increases with both water tree depth and cable temperature and is relatively independent of changing water tree AR. As for resistance, there is no apparent change between depth percentages of 10 and 80 for both solutions. This is because the water tree has not yet entered the conductor and thus there is no shorting current flowing through the tree yet. Between 80 and 100% water tree depth, it is observed that for both solutions there is a rapid decrease in resistance because the tree is now impacting the conductor shield and allowing shorting current to flow through it. The relationship between resistance and temperature was found to be inversed. As temperature increases, resistance decreases for both water tree solutions with distilled water having the most apparent difference across the range of temperatures simulated. With regards to water tree AR, resistance was found to be relatively independent at depth percentages of 10, 50, and 70, but there was some relationship at 100% depth for both solutions. At this depth, as water tree AR increased, resistance was found to also increase. Through the examination of voltage and electric field distribution plots, it was confirmed for EPR cables that increasing water tree depth leads to increasing distortion. The increase in shorting current at 100% depth for aqueous copper sulfate compared to distilled water was also visualized. Lastly, the relationship between shorting current and temperature for narrow water trees was visualized and validated using the distribution plots. This study has led to a better understanding of the effect of cable temperature, water tree solution, and geometry of the tree region on cable degradation. Furthermore, this study has documented simulation results of water tree degradation in EPR MV cables, which had been previously lacking in information. Future work in this area will add frequency into the mix and examine what effect it has on the rate of cable degradation as a result of water treeing. To compliment the work being carried by UMD on different polymer chemistries, harvested medium voltage (MV) cables were selected for accelerated aging study at ORNL. These medium voltage cables are representative of the vintages and materials that are currently in use at existing nuclear power plants (NPPs). These cables were immersed in water at 90°C and energized for a period of two years at elevated voltage. Partial discharge was measured during this period of time to track potential degradation. Unfortunately, due to the absence of failure, the extent of integration between the UMD techniques and the harvested MV insulation was limited. However, based on the findings and from the UMD research in the previous sections on polyethylene and polypropylene, follow-on characterization for harvested MV cable insulation should focus on sample preparation to take advantage of the UMD techniques to better understand mechanistic degradation in MV cable insulations. This would include: 1.) Utilization of solutions and impedance measurement insulation to track permeability in harvested and accelerated aging insulation samples, 2.) Adaptation of gold nanoparticle synthesis for electrical impedance spectroscopy with supporting SEM characterization to study pore formation in harvested and accelerated aged insulation samples, & 3.) ATR-FTIR crystallinity with multiple temperature dependent harvested MV cable insulation under different air and submerged accelerated aging. In addition, low voltage dielectric spectroscopy and high voltage dissipation factor, tan δ, could be implemented as a condition monitoring tool for harvested MV cable insulation in submerged environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Feasibility of source-free DAS logging for next-generation borehole imaging

Characterizing and monitoring geologic formations around a borehole are crucial for energy and environmental applications. However, conventional wireline sonic logging usually cannot be used in high-temperature environments nor is the tool feasible for long-term monitoring. We introduce and evaluate the feasibility of a source-free distributed-acoustic-sensing (DAS) logging method based on borehole DAS ambient noise. Our new logging method provides a next-generation borehole imaging tool. The tool is source free because it uses ever-present ambient noises as sources and does not need a borehole sonic source that cannot be easily re-inserted into a borehole after well completion for time-lapse monitoring. The receivers of our source-free DAS logging tool are fiber optic cables cemented behind casing, enabling logging in harsh, high-temperature environments, and eliminating the receiver repeatability issue of conventional wireline sonic logging for time-lapse monitoring. We analyze a borehole DAS ambient noise dataset to obtain root-mean-squares (RMS) amplitudes and use these amplitudes to infer subsurface elastic properties. We find that the ambient noise RMS amplitudes correlate well with anomalies in conventional logging data. The source-free DAS logging tool can advance our ability to characterize and monitor subsurface geologic formations in an efficient and cost-effective manner, particularly in high-temperature environments such as geothermal reservoirs. Further validation of the source-free DAS logging method using other borehole DAS ambient noise data would enable the new logging tool for wider applications.

58 GEOSCIENCES↗

Thermal-mechanical properties of epoxy-impregnated Bi-2212/Ag composite

In this study, knowledge of the thermal-mechanical properties of epoxy/superconductor/insulation composite is important for designing, fabricating, and operating epoxy impregnated high field superconducting magnets near their ultimate potentials. We report measurements of the modulus of elasticity, Poisson's ratio, and the coefficient of thermal contraction of epoxy-impregnated composite made from the state-of-the-art powder-in-tube multifilamentary Ag/Bi 2 Sr 2 CaCu 2 O x round wire at room temperature and cryogenic temperatures. Stress-strain curves of samples made from single-strand and Rutherford cables were tested under both monotonic and cyclic compressive loads, with single strands insulated using a thin TiO 2 insulation coating and the Rutherford cable insulated with a braided ceramic sleeve.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗