Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electric power reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The Challenge Posed by Geomagnetic Activity to Electric Power Reliability: Evidence from England and Wales

This paper addresses whether geomagnetic activity challenged the reliability of the electric power system during part of the declining phase of solar cycle 23. Operations by National Grid in England and Wales are examined over the period of 11 March 2003 through 31 March 2005. This paper examines the relationship between measures of geomagnetic activity and a metric of challenged electric power reliability known as the net imbalance volume (NIV). Measured in megawatt hours, NIV represents the sum of all energy deployments initiated by the system operator to balance the electric power system. The relationship between geomagnetic activity and NIV is assessed using a multivariate econometric model. The model was estimated using half-hour settlement data over the period of 11 March 2003 through 31 December 2004. The results indicate that geomagnetic activity had a demonstrable effect on NIV over the sample period. Based on the parameter estimates, out-of-sample predictions of NIV were generated for each half hour over the period of 1 January to 31 March 2005. Consistent with the existence of a causal relationship between geomagnetic activity and the electricity market imbalance, the root-mean-square error of the out-of-sample predictions of NIV is smaller; that is, the predictions are more accurate, when the statistically significant estimated effects of geomagnetic activity are included as drivers in the predictions.

Forbes, Kevin F.↗

Did Geomagnetic Activity Challenge Electric Power Reliability During Solar Cycle 23? Evidence from the PJM Regional Transmission Organization in North America

During solar cycle 22, a very intense geomagnetic storm on 13 March 1989 contributed to the collapse of the Hydro-Quebec power system in Canada. This event clearly demonstrated that geomagnetic storms have the potential to lead to blackouts. This paper addresses whether geomagnetic activity challenged power system reliability during solar cycle 23. Operations by PJM Interconnection, LLC (hereafter PJM), a regional transmission organization in North America, are examined over the period 1 April 2002 through 30 April 2004. During this time PJM coordinated the movement of wholesale electricity in all or parts of Delaware, Maryland, New Jersey, Ohio, Pennsylvania, Virginia, West Virginia, and the District of Columbia in the United States. We examine the relationship between a proxy of geomagnetically induced currents (GICs) and a metric of challenged reliability. In this study, GICs are proxied using magnetometer data from a geomagnetic observatory located just outside the PJM control area. The metric of challenged reliability is the incidence of out-of-economic-merit order dispatching due to adverse reactive power conditions. The statistical methods employed make it possible to disentangle the effects of GICs on power system operations from purely terrestrial factors. The results of the analysis indicate that geomagnetic activity can significantly increase the likelihood that the system operator will dispatch generating units based on system stability considerations rather than economic merit.

storms↗

LBNL CRADA (FP00009949) with the American Public Power Association: Electricity Reliability Metrics, Analysis, and Planning (Final Technical Report)

LBNL and APPA (the team) jointly examined the extent to which differences in distribution feeder characteristics are correlated with differences in their reliability performance when exposed to three different types of natural hazards (wildlife, weather, and vegetation). The team employed data-driven approaches to quantify the relationships between various measures of feeder reliability and a suite of feeder characteristics individually and jointly via a statistically-based clustering method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Explained: Fundamentals of Power Grid Reliability and Clean Electricity

Maintaining reliability of the bulk power system, which supplies and transmits electricity, is a critical priority for electric grid planners, operators, and regulators. As we move toward a cleaner electricity system with more technologies like wind, solar, and battery storage, the way in which we plan for and achieve reliability will change. This fact sheet provides additional technical background to the topics covered in three other reliability explainers on how we measure, enforce, and plan for reliable systems with more clean electricity.

POWER TRANSMISSION AND DISTRIBUTION↗

Tandem concentrator solar cells with 30 percent (AMO) power conversion efficiency

Very high efficiency concentrator solar panels are envisioned as economical and reliable electrical power subsystems for space based platforms of the future. GaAs concentrator cells with very high efficiencies and good sub-bandgap transmissions can be fabricated on standard wafers. GaSb booster cell development is progressing very well; performance characteristics are still improving dramatically. Consistent GaAs/GaSb stacked cell AMO efficiencies greater than 30 percent are expected.

Avery, J. E.↗

Electric Grid Blackstart: Trends, Challenges, and Opportunities

This report studies the expected future state of the grid and recommends actions that can be taken to increase grid resiliency, improve system modeling, perform more extensive studies, enhance training activities, and perform industry outreach for the purpose of the blackstart capabilities of power systems. The report is a revised version of PNNL-29118.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reese Housing Power Project (Final Technical Report)

The Reese Housing Power Project is located on Tribal trust land in Colusa, CA and expands existing medium-voltage distribution to seven new households with the addition of medium-voltage cabling, step down transformers, smart meters, and street lighting for the new development. The Tribe utilized their existing Co-Generation power plant and micro grid to supply the new homes with highly reliable power with fewer interruptions and at a reduced rate compared with the local utility. The project gives the Tribe greater independence from traditional power sources and provides jobs for the community. The project reduces electric energy costs, increases Tribe self-reliance, and provides highly reliable electric power to seven tribal members’ homes. Construction of the project also provided jobs for the community.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Energy Resource (DER) Reliability for Backup Electric Power Systems

Hospitals, emergency services, military bases, ports, airports, industries, commercial facilities, and others rely on backup power systems to provide electricity for their critical loads during grid outages. The purpose of this report it to provide accurate reliability information on commonly deployed distributed energy resources (DERs) to improve quantitative estimates for the reliability of these backup power systems during a grid outage. A backup power system consists of DERs, an electric distribution system with its associated switches and other devices, and mechanisms to control and manage the flow of electricity. Too often, facilities and campuses fail to properly quantify the reliability of their backup power systems. DERs are assumed to be 100% reliable, with the only concern being the availability of fuel. Such assumptions can lead to gross errors in the backup system's reliability estimates, particularly for long-duration outages. This report provides a set of estimates for reliability of emergency diesel generators (EDGs), natural gas prime generators and combined heat and power (CHP) prime movers, solar photovoltaics (PV), wind turbines, and Li-ion battery energy storage systems (BESS). The estimates are derived from empirical data when available and supplemented by modeling results when needed. These reliability estimates are for the DERs ability to provide power during a grid outage, ranging from an hour to 2 weeks.

14 SOLAR ENERGY↗

Photovoltaic power modules for NASA's manned space station

The capability and the safety of manned spacecraft are largely dependent upon reliable electric power systems. Two similar space power systems able to survive the low Earth orbit environment, are being considered for NASA's Manned Space Station (SS), scheduled to begin operation in the mid 1990's. The Space Station Electric Power System (EPS) is composed of Photovoltaic (PV) Power Modules, Solar Dynamic (SD) Power Modules, and the Power Management and Distribution (PMAD) System. One EPS configuration will deliver 37.5 kW of PV based, utility grade, ac power to SS users. A second 75 kWe PV based EPS option is also being considered for SS deployment. The two EPS options utilize common modules and differ only in the total number of PV Power Modules used. Each PV Power Module supplies 18.75 kWe of ac power and incorporates its own energy storage and thermal control. The general requirements and the current preliminary design configuration of the Space Station PV Power Modules are examined.

Tatro, Charles A.↗

Photovoltaic power modules for NASA's manned Space Station

The capability and the safety of manned spacecraft are largely dependent upon reliable electric power systems. Two similar space power systems able to survive the low earth orbit environment, are being considered for NASA's Manned Space Station (SS), scheduled to begin operation in the mid 1990's. The Space Station Electric Power System (EPS) is composed of Photovoltaic (PV) Power Modules, Solar Dynamic (SD) Power Modules, and the Power Management and Distribution (PMAD) System. One EPS configuration will deliver 37.5 kW of PV based, utility grade, ac power to SS users. A second 75 kWe PV based EPS option is also being considered for SS deployment. The two EPS options utilize common modules and differ only in the total number of PV Power Modules used. Each PV Power Module supplies 18.75 kWe of ac power and incorporates its own energy storage and thermal control. The general requirements and the current preliminary design configuration of the Space Station PV Power Modules are examined.

Tatro, C. A.↗

Predicting the Reliability of Solar-Cell Interconnections

The reduction of life expectancy by thermal cycling calculated during design. Connections between solar cells critical parts of solarcell arrays generating electric power. Reliability affects life expectancy of modules, panels, and arrays. Used to predict stress-cycle lifetimes of such structures as arches, walkways, cylindrical ribbing of aircraft fuselages and submarine hulls, and pipeline expansion loops. Testing costs reduced by about 90 percent.

Mon, G. R.↗

Operational performance of the photovoltaic-powered grain mill and water pump at Tangaye, Upper Volta

The first two years of operation of a stand alone photovoltaic (PV) power system for the village of Tangaye, Upper Volta in West Africa are described. The purpose of the experiment was to demonstrate that PV systems could provide reliable electrical power for multiple use applications in remote areas where local technical expertise is limited. The 1.8 kW (peak) power system supplies 120-V (d.c.) electrical power to operate a grain mill, a water pump, and mill building lights for the village. The system was initially sized to pump a part of the village water requirements from an existing improved well, and to meet a portion of the village grain grinding requirements. The data, observations, experiences, and conclusions developed during the first two years of operation are discussed. Reports of tests of the mills used in the project are included.

Martz, J. E.↗

Ultra-Fast Resonant DC Breaker

This project’s focus was to create an ultra-fast resonant hybrid dc circuit breaker for medium voltage electric systems. Medium voltage DC systems offer higher efficiency, additional resiliency, more controllability, and greater flexibility over comparable AC systems. Although technically, medium voltage DC systems are more attractive than their AC counterparts, no solution exists for the protection of medium voltage DC systems, and thus one cannot build a reliable MVDC system. This research will fill the technology gap, providing a MVDC protection solution, allowing mass adoption and proliferation of MVDC systems. MVDC systems will allow greater integration of renewable energy sources, higher efficiency of transmission and distribution, reduced losses in transmission lines, reduce carbon emissions, and higher electric power reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The impact of market design and clean energy incentives on strategic generation investments and resource adequacy in low-carbon electricity markets

Well-designed electricity markets play a crucial role in maintaining reliable electric power systems, which are critical in modern society. Here, this study examines the impact of different electricity market designs and clean energy incentive schemes on supporting renewable energy integration and achieving clean energy goals. To this end, we utilize a game-theoretical generation expansion planning model where generation companies make investment and retirement decisions to maximize their expected profit. The model is structured as an equilibrium problem with equilibrium constraints (EPEC) and solved using a diagonalization approach combined with progressive hedging. We analyze three types of electricity market designs: an energy-only market, a capacity market, and a clean energy market, and consider a wide range of market parameters resulting in 14 total scenarios. Wind and solar capacity comprise the majority of new investments in all considered scenarios, but the resultant system planning reserve margin (PRM) can differ significantly depending on market parameters. We also find that profit-driven investments lead to lower PRMs than a traditional system cost minimization approach. These individual scenario results further demonstrate how different market designs and clean energy incentive schemes may influence investor decision-making and impact resource adequacy throughout the clean energy transition.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimizing Hydride Stability in U-ZrH x Nuclear Fuel: The “Goldilocks Radius”

Nuclear-powered microreactors show great promise for opening new nuclear energy markets due to the flexibility offered by their rapid/streamlined in-factory fabrication, transportability, and self-regulating nature. The economic benefits of any commercialized nuclear reactor, however, rely on the system’s ability to produce large amounts of heat and efficiently convert that heat into electrical power reliably for long periods of time. Uranium-zirconium hydride (U-ZrH x ) is currently being considered for compact reactor designs because it is a well-known nuclear fuel system that is self-moderating, but this fuel, which has historically been used for research reactors, has not been optimized for commercial power production. Here, this paper analyzes the hydride stability of standard 304 stainless steel–clad U-ZrH x fuel under commercially relevant conditions. Fuel element design parameters, including physical dimensions, as-fabricated hydrogen content, burnup, peak fuel temperature, temperature gradient, operational fuel cycle duration, and volumetric heat generation rate, are discussed with a focus on hydrogen distribution and phase stability within the fuel element. Hydride stability declines more rapidly as the coolant temperature, burnup, and fuel cycle duration increase. Using a fuel-cladding gap material with heat transfer properties superior to air, such as helium or sodium, is essential to prolonging fuel hydride stability. The fuel’s physical dimensions are also important. At very small fuel diameters, the H/Zr ratio in the fuel meat decreases too rapidly due to the hydrogen content’s dependence on fuel meat volume. Conversely, the fuel meat temperature and temperature gradient exacerbate hydrogen loss at very large fuel diameters. We find that the most important parameter to consider when optimizing the hydride stability of U-ZrH x fuel is the relationship between the fuel meat radius and the power density in the fuel. A simple equation is empirically determined that relates the “Goldilocks radius,” that is, the fuel radius for which the H/Zr ratio is most stable, to the power density in the fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FLC Award: QED: Quantum Ensured Defense of the Smart Electric Grid

A reliable electric power supply is crucial for modern day life as well as national security, economic productivity, and life-and-death essentials. During the COVID pandemic, internet and cell communications became a “must-have” for government and business operations, education, and communicating COVID testing for vaccine information. Loss of electric power quickly leads to human health and national security emergencies. When a major winter storm hit Texas in mid-February 2021, the system was overwhelmed and over 4M people lost power. Although this crisis arose from an unprecedented weather event - not a cyberattack - it serves as a vivid illustration of the impact power disruption can have on our American way of life. The recent cyberattack on the Colonial Oil Pipeline also provides a stark reminder that infrastructure supporting our daily lives has vulnerabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗