Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electric variables”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Electrically Variable or Programmable Nonvolatile Capacitors

Electrically variable or programmable capacitors based on the unique properties of thin perovskite films are undergoing development. These capacitors show promise of overcoming two important deficiencies of prior electrically programmable capacitors: Unlike in the case of varactors, it is not necessary to supply power continuously to make these capacitors retain their capacitance values. Hence, these capacitors may prove useful as components of nonvolatile analog and digital electronic memories. Unlike in the case of ferroelectric capacitors, it is possible to measure the capacitance values of these capacitors without changing the values. In other words, whereas readout of ferroelectric capacitors is destructive, readout of these capacitors can be nondestructive. A capacitor of this type is a simple two terminal device. It includes a thin film of a suitable perovskite as the dielectric layer, sandwiched between two metal or metal oxide electrodes (for example, see Figure 1). The utility of this device as a variable capacitor is based on a phenomenon, known as electrical-pulse-induced capacitance (EPIC), that is observed in thin perovskite films and especially in those thin perovskite films that exhibit the colossal magnetoresistive (CMR) effect. In EPIC, the application of one or more electrical pulses that exceed a threshold magnitude (typically somewhat less than 1 V) gives rise to a nonvolatile change in capacitance. The change in capacitance depends on the magnitude duration, polarity, and number of pulses. It is not necessary to apply a magnetic field or to cool the device below (or heat it above) room temperature to obtain EPIC. Examples of suitable CMR perovskites include Pr(1-x)Ca(x)MnO3, La(1-x)S-r(x)MnO3,and Nb(1-x)Ca(x)MnO3. Figure 2 is a block diagram showing an EPIC capacitor connected to a circuit that can vary the capacitance, measure the capacitance, and/or measure the resistance of the capacitor.

Shangqing, Liu↗

Progressing Analysis of Variable Electric Rates (PAVER) Study

The Progressing Analysis of Variable Electric Rates (PAVER) study analyzed the impact of a range of time-varying electric rates on the performance of a regional electric grid and the resulting costs for participating and non-participating customers. This analysis leveraged and extended the work of PNNL’s Distribution System Operator with Transactive (DSO+T) study. Five different rate designs were included: a flat volumetric energy charge, a typical Time of Use (TOU) rate, a dynamic energy (DE) rate (based on wholesale locational marginal prices), a dynamic energy and capacity (DE+C) rate, and, finally, a Block and Swing (B&S) rate that billed customers based on their average load profile at constant pricing, but used the DE+C dynamic price for load deviations from their average profile. These rates were analyzed in a large-scale co-simulation of an entire regional grid with a customer population representative of the current state. A large fraction (80%) of residential and commercial customers were assumed to participate in these time-varying rates with automatically controlled HVAC, water heaters, electric vehicles, and batteries. This study assumed no industrial sector participation. The DE and DE+C rates saw system peak loads reduced by 6-7%, while the large participation in the TOU rate case saw a significant rebound effect and a resulting peak load increase of >5%. The impacts to the annual and peak system demand impacted system wholesale prices and the overall grid operating costs. This cost structure determined the revenue needed to be collected from customers by each rate design. Participating customers on the DE and DE+C rates (located in one of the modeled DSOs) saw reductions in average annual electricity bills of 11-17% with average increases in monthly bill variation of no more than 13%. At such high participation levels, TOU customers saw 10% higher average annual bills (due to system-wide rebound effects) and average increased monthly bill variation of 16%. Residential owners of large flexible loads (such as electric vehicles) saw larger bill savings (17-20%) when on a fully dynamic rate. The presence of on-site generation (such as rooftop solar) did not appear to appreciably change customer outcomes. Customers on the Block and Swing rate did see 6% lower monthly bill variation (as intended) than the flat rate case, but at the expense of appreciable bill savings, which were only 3%, comparable to the savings seen by non-participants. Given this finding we recommend that additional research be conducted into how best various bill protection mechanisms can balance minimizing customer bill variation with providing financial incentives commensurate with the flexibility customers provide. We also recommend that customer outcomes be explored across a range of regions using current actual customer and system cost data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electrically Variable Resistive Memory Devices

Nonvolatile electronic memory devices that store data in the form of electrical- resistance values, and memory circuits based on such devices, have been invented. These devices and circuits exploit an electrically-variable-resistance phenomenon that occurs in thin films of certain oxides that exhibit the colossal magnetoresistive (CMR) effect. It is worth emphasizing that, as stated in the immediately preceding article, these devices function at room temperature and do not depend on externally applied magnetic fields. A device of this type is basically a thin film resistor: it consists of a thin film of a CMR material located between, and in contact with, two electrical conductors. The application of a short-duration, low-voltage current pulse via the terminals changes the electrical resistance of the film. The amount of the change in resistance depends on the size of the pulse. The direction of change (increase or decrease of resistance) depends on the polarity of the pulse. Hence, a datum can be written (or a prior datum overwritten) in the memory device by applying a pulse of size and polarity tailored to set the resistance at a value that represents a specific numerical value. To read the datum, one applies a smaller pulse - one that is large enough to enable accurate measurement of resistance, but small enough so as not to change the resistance. In writing, the resistance can be set to any value within the dynamic range of the CMR film. Typically, the value would be one of several discrete resistance values that represent logic levels or digits. Because the number of levels can exceed 2, a memory device of this type is not limited to binary data. Like other memory devices, devices of this type can be incorporated into a memory integrated circuit by laying them out on a substrate in rows and columns, along with row and column conductors for electrically addressing them individually or collectively.

Liu, Shangqing↗

Intense, variable electric fields at ionospheric altitudes in the high latitude regions as observed by DE-2

Intense, variable electric fields have been observed by DE-2 using the double probe technique at ionospheric altitudes in high latitude regions. Measurements are made of both components of the electric field in the orbit plane (90 deg geographic inclination) at a rate of 16 samples/sec (0.5 km spatial resolution). Small scale, spike-like variations with amplitudes of over 100 mV/m are frequently seen in the polar cusp region and, to a lesser degree, also in the nightside auroral oval. Magnitudes up to 240 mV/m have been observed. These variations often occur over scale lengths of a few km or less. The fine structure in the cusp is consistent with the concept of limited regions of direct access within a larger overall region. It would appear that the intense electric fields which are observed at higher altitudes in the magnetosphere may penetrate to lower altitudes more extensively than indicated by previous measurements.

Maynard, N. C.↗

Islanding Detection of Distributed Generation Using Electrical Variables in Space Vector Domain

This paper presents a new approach for islanding detection in distribution systems incorporating synchronous generator-based distributed generations. The proposed method first utilizes the dynamic equations of three electrical variables under islanding situations. The variables are: change of frequency; rate of change of frequency; and rotor angle deviation. Second, transformation of these variables is conducted in the space vector domain, which gives rise to three parameters, namely, semi-major axis, semi-minor axis, and inclination angle. Finally, exploiting these parameters, a decision boundary is established to classify grid events resulting in the formation of an island or not. The proposed method is comprehensively investigated under different operating conditions, which include excess/deficit of reactive/active power imbalance scenarios in the formed island containing different load-types (constant impedance, constant power, and constant current) with varying quality factor. A large variety of islanding and non-islanding events are generated using a practical distribution network simulated in real time on OPAL-RT digital simulation platform under the aforementioned operating conditions. A detailed evaluation of the proposed approach is conducted and it demonstrates the effectiveness of the method.

F-measure↗

Grid-responsive hydrogen production: Capital utilization and current density vs. efficiency in variable electricity markets

To achieve low-cost hydrogen production from water electrolyzers, grid tied electrolysis may need to operate dynamically to minimize the cost of supplying energy to the electrolyzer stack and produce hydrogen during low-cost hours and turn off/down during high-cost hours. Operating systems in this way can decrease capital utilization (capacity factor) and electricity costs. This strategy would shift the dominant cost drivers away from electricity (and thus efficiency) to the capital costs of the system, due to the underutilized capital when operating at low-capacity factors. Increasing the operational current density of the system could, in effect, reduce the capital cost of the system while producing hydrogen at a lower efficiency on a per unit energy basis. In the variable electricity cost profiles analyzed in this paper, increasing the current density for liquid alkaline from 0.5 A/cm2 to 1.5 Ac/m2 and proton exchange membrane electrolyzers from 2 A/cm2 to 4 A/cm2 resulted in substantial reductions in the levelized cost of hydrogen. Additionally, as capacity factors and electricity costs decrease, the optimal operating current density of the electrolyzer systems analyzed increases. These findings suggest R&D efforts should focus on increasing the operational current densities, reducing the turn down ratios, and understanding the durability implications of those strategies on low-temperature liquid alkaline and proton exchange membrane electrolyzers.

08 HYDROGEN↗

Heat Storage Coupled to Generation IV Reactors for Variable Electricity from Base-load Reactors: Workshop Proceedings. Changing markets, technology, nuclear-renewables integration and synergisms with solar thermal power systems

Electricity markets are changing because of (1) the addition of wind and solar that creates volatile electricity prices including times of zero-priced electricity and (2) the goal of a low-carbon world that requires replacing fossil fuels that provide (a) energy, (b) stored energy, and (c) dispatchable energy. Wind and solar provide energy but not the other two other energy functions that are provided fossil fuels. Nuclear energy with heat storage can provide all three functions and thus replace fossil fuels.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Production of plasma with variable, radial electric fields

A device is described suitable for plasma wave experiments requiring relatively large, variable, radial electric fields perpendicular to a static magnetic field. By separately adjusting the potentials of two independent, coaxial discharge plasmas, the authors produced plasmas with a radial electric field E sub r less than approximately 5 V/cm.

Kustom, B.↗

Impacts of long-term temperature change and variability on electricity investments

Long-term temperature change and variability are expected to have significant impacts on future electric capacity and investments. This study improves upon past studies by accounting for hourly and monthly dynamics of electricity use, long-term socioeconomic drivers, and interactions of the electric sector with rest of the economy for a comprehensive analysis of temperature change impacts on cooling and heating services and their corresponding impact on electric capacity and investments. Using the United States as an example, here we show that under a scenario consistent with a socioeconomic pathway 2 (SSP2) and representative concentration pathway 8.5 (RCP 8.5), mean temperature changes drive increases in annual electricity demands by 0.5-8% across states in 2100. But more importantly, peak temperature changes drive increases in capital investments by 3-22%. Moreover, temperature-induced capital investments are highly sensitive to both long-term socioeconomic assumptions and spatial heterogeneity of fuel prices and capital stock characteristics, which underscores the importance of a comprehensive approach to inform long-term electric sector planning.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Differentially Variable Component Analysis (dVCA): Identifying Multiple Evoked Components using Trial-to-Trial Variability

Electric potentials and magnetic fields generated by ensembles of synchronously active neurons in response to external stimuli provide information essential to understanding the processes underlying cognitive and sensorimotor activity. Interpreting recordings of these potentials and fields is difficult as each detector records signals simultaneously generated by various regions throughout the brain. We introduce the differentially Variable Component Analysis (dVCA) algorithm, which relies on trial-to-trial variability in response amplitude and latency to identify multiple components. Using simulations we evaluate the importance of response variability to component identification, the robustness of dVCA to noise, and its ability to characterize single-trial data. Finally, we evaluate the technique using visually evoked field potentials recorded at incremental depths across the layers of cortical area VI, in an awake, behaving macaque monkey.

Knuth, Kevin H.↗

Analysis of Correlation between Cold Weather Meteorological Variables and Electricity Outages

The significance of the impact of weather on the electric grid has grown as climate change continues to increase the frequency and intensity of extreme weather events. In recent years (2021-2022) in particular, extreme winter weather has affected the grid in locations in the US rarely exposed to extreme low temperatures, snow and icing conditions. Here we analyze the correlation between cold weather meteorological variables and electricity outages during two large winter storm events, Uri (February 2021) and Landon (February 2022) using Random Forest machine learning and Pearson’s correlation coefficient. Our geographical focus across the two storms is the state of Texas. Extrapolation of the method to winter weather impacts over other years and additional locations is proposed.

Dumas, Melissa↗

Multiple and variable speed electrical generator systems for large wind turbines

A cost effective method to achieve increased wind turbine generator energy conversion and other operational benefits through variable speed operation is presented. Earlier studies of multiple and variable speed generators in wind turbines were extended for evaluation in the context of a specific large sized conceptual design. System design and simulation have defined the costs and performance benefits which can be expected from both two speed and variable speed configurations.

Andersen, T. S.↗

Spatiotemporal Variability of Electric System Reliability Metrics

As urbanization continues to grow, urban density also rises, placing significant stress on critical infrastructure. Cities often face challenges in investing in new infrastructure or upgrading existing ones. One area of infrastructure that has come under strain is the electric grid, leading to prolonged power outages. According to data from the U.S. Energy Information Administration, the average duration of power outages has steadily doubled from 2013 to 2021, primarily due to extreme weather events. The IEEE has developed a series of reliability metrics to assess the reliability of the electric system. However, these metrics are only applied at the utility level, making it challenging to comprehend the variations in these indices at finer spatial resolutions and, consequently, evaluate reliability at the non-utility level. In this study, we leveraged electric outage data collected at 15-minute intervals at the county level to estimate electric system reliability over a six-year period using a novel data analysis approach. Our findings reveal a gradual decline in reliability in the U.S. Southwest compared to national averages. Furthermore, the duration of outages per customer per event has significantly decreased in large portions of California and Florida. These discoveries can be valuable for utility companies as they seek to pinpoint regional anomalies and plan for prioritized remediation efforts.

Singh, Nagendra↗

Low-cost crushed-rock heat storage with oil or salt heat transfer

The demand for variable electricity and heat is met by fossil-fuel power plants because the power plant capital costs and the cost of storing fossil fuels are low. A low-carbon economy requires replacement of the storage function of fossil fuels to provide variable heat and electricity as needed. The Crushed Rock Ultra-large Stored Heat (CRUSH) system is a new technology with the goal to provide heat storage at an incremental capital cost of $2–4/kWh at scales of 10 s to 100 s of GWhs that enables economic daily to multi-week storage. CRUSH can be coupled to nuclear power plants, concentrated solar power (CSP) plants and thermal energy batteries to provide variable electricity and heat on demand. Sensible heat is stored in crushed rock—the lowest-cost heat-storage material. Heat is transferred to and from the crushed rock using nitrate salt or heat-transfer oils but these fluids do not store heat. Heat from a nuclear reactor, CSP plant or conversion of low-price electricity into heat is used to heat the salt or oil. The hot fluid is poured over the crushed rock, trickles downward by gravity through the rock, heats the rock and is collected by the drain pans under the crushed rock. To recover heat cold salt or oil is poured over hot crushed rock, trickles down by gravity while being heated and is collected by the drain pans under the crushed rock. The system design and engineering trade-offs are described. The technology is in the early stages of development.

20 FOSSIL-FUELED POWER PLANTS↗

Efficiency arcjet thruster with controlled arc startup and steady state attachment

An improved efficiency arcjet thruster has a constrictor and electrically-conductive nozzle anode defining an arc chamber, and an electrically-conductive rod having a tip spaced upstream from the constrictor and defining a cathode spaced from the anode by a gap generally coextensive with the arc chamber. An electrical potential is applied to the anode and cathode to generate an electrical arc in the arc chamber from the cathode to anode. Catalytically decomposed hydrazine is supplied to the arc chamber with generation of the arc so as to produce thermal heating and expansion thereof through the nozzle. The constrictor can have a electrically insulative portion disposed between the cathode tip and the nozzle anode, and an electrically-conductive anode extension disposed along the insulative portion so as to define an auxiliary gap with the cathode tip substantially smaller than the gap defined between the cathode and nozzle anode for facilitating startup of arc generation. The constrictor can also include an electrically-conductive electrode with a variable electrical potential to vary the shape of the arc generated in the arc chamber. Also, the cathode is mounted for axial movement such that the gap between its tip and the nozzle anode can be varied to facilitate a generally nonerosive generation of the electrical arc at startup and reliable steady state operation. Further, the arc chamber can have a nonparallel subsonic-to-supersonic transition configuration, or alternatively solely a nonparallel supersonic configuration, for improved arc attachment.

Smith, William W.↗