Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electric variables”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Progressing Analysis of Variable Electric Rates (PAVER) Study

The Progressing Analysis of Variable Electric Rates (PAVER) study analyzed the impact of a range of time-varying electric rates on the performance of a regional electric grid and the resulting costs for participating and non-participating customers. This analysis leveraged and extended the work of PNNL’s Distribution System Operator with Transactive (DSO+T) study. Five different rate designs were included: a flat volumetric energy charge, a typical Time of Use (TOU) rate, a dynamic energy (DE) rate (based on wholesale locational marginal prices), a dynamic energy and capacity (DE+C) rate, and, finally, a Block and Swing (B&S) rate that billed customers based on their average load profile at constant pricing, but used the DE+C dynamic price for load deviations from their average profile. These rates were analyzed in a large-scale co-simulation of an entire regional grid with a customer population representative of the current state. A large fraction (80%) of residential and commercial customers were assumed to participate in these time-varying rates with automatically controlled HVAC, water heaters, electric vehicles, and batteries. This study assumed no industrial sector participation. The DE and DE+C rates saw system peak loads reduced by 6-7%, while the large participation in the TOU rate case saw a significant rebound effect and a resulting peak load increase of >5%. The impacts to the annual and peak system demand impacted system wholesale prices and the overall grid operating costs. This cost structure determined the revenue needed to be collected from customers by each rate design. Participating customers on the DE and DE+C rates (located in one of the modeled DSOs) saw reductions in average annual electricity bills of 11-17% with average increases in monthly bill variation of no more than 13%. At such high participation levels, TOU customers saw 10% higher average annual bills (due to system-wide rebound effects) and average increased monthly bill variation of 16%. Residential owners of large flexible loads (such as electric vehicles) saw larger bill savings (17-20%) when on a fully dynamic rate. The presence of on-site generation (such as rooftop solar) did not appear to appreciably change customer outcomes. Customers on the Block and Swing rate did see 6% lower monthly bill variation (as intended) than the flat rate case, but at the expense of appreciable bill savings, which were only 3%, comparable to the savings seen by non-participants. Given this finding we recommend that additional research be conducted into how best various bill protection mechanisms can balance minimizing customer bill variation with providing financial incentives commensurate with the flexibility customers provide. We also recommend that customer outcomes be explored across a range of regions using current actual customer and system cost data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Heat Storage Options for Sodium, Salt and Helium Cooled Reactors to Enable Variable Electricity to the Grid and Heat to Industry with Base-Load Reactor Operations

Electricity markets are changing rapidly because of (1) the addition of wind and solar and (2) the goal of a low-carbon electricity grid. These changes result in times of high electricity prices and very low or negative electricity prices. California has seen its first month where more than 20% of the time (mid-day) the wholesale price of electricity was zero or negative. This creates large incentives for coupling heat storage to advanced reactors to enable variable electricity and industrial-heat output (to maximize revenue) while the reactor operates at base load (minimize cost). Recent studies have examined coupling various types of heat storage to Rankine and Brayton power cycles. However, there has been little examination of heat-storage options between (1) the reactor and (2) the power-conversion system or industrial customer. Heat-storage systems can be incorporated into sodium , helium-, and salt-cooled reactors. Salt-cooled reactors include the fluoride-salt-cooled high-temperature reactor (FHR) with its solid fuel and clean coolant and the molten salt reactor (MSR) with its fuel dissolved in the salt. For sodium and salt reactors, it is assumed that a heat-storage system would be in the secondary loop between the reactor and power cycle. For helium-cooled reactors, heat storage can be in the primary or secondary loop. This report is a first look at the rational and the heat storage options for deploying gigawatt-watt hour heat-storage systems with GenIV reactors. Economics and safety are the primary selection criteria. The leading heat-storage candidate for sodium-cooled systems (a low-pressure secondary system with small temperature drop across the reactor core) is sodium coolant stored in large steel tanks, with the coolant transferring heat in channels. The design minimizes sodium volume in the storage and, thus, the risks and costs associated with sodium. For helium systems (high-pressure with large temperature drop across the core), the leading heat storage options are (1) varying the temperature of the reactor core, (2) steel or alumina firebrick in a secondary pressure vessel and (3) nitrate or hot-rock/firebrick at atmospheric pressure. For salt systems (low pressure, high temperatures, and small temperature drop across the reactor core) the leading heat-storage systems are secondary salts. In each case, options are identified and questions to be addressed are identified. In some cases there is a strong coupling between the heat-storage technology and the power cycle. The leading sodium heat-storage technology may imply changes in the power cycle. High-temperature salt systems couple efficiency to Brayton power cycles that may create large incentives for the heat storage to remain within the power cycle rather than in any intermediate heat transfer loop.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Islanding Detection of Distributed Generation Using Electrical Variables in Space Vector Domain

This paper presents a new approach for islanding detection in distribution systems incorporating synchronous generator-based distributed generations. The proposed method first utilizes the dynamic equations of three electrical variables under islanding situations. The variables are: change of frequency; rate of change of frequency; and rotor angle deviation. Second, transformation of these variables is conducted in the space vector domain, which gives rise to three parameters, namely, semi-major axis, semi-minor axis, and inclination angle. Finally, exploiting these parameters, a decision boundary is established to classify grid events resulting in the formation of an island or not. The proposed method is comprehensively investigated under different operating conditions, which include excess/deficit of reactive/active power imbalance scenarios in the formed island containing different load-types (constant impedance, constant power, and constant current) with varying quality factor. A large variety of islanding and non-islanding events are generated using a practical distribution network simulated in real time on OPAL-RT digital simulation platform under the aforementioned operating conditions. A detailed evaluation of the proposed approach is conducted and it demonstrates the effectiveness of the method.

F-measure↗

Grid-responsive hydrogen production: Capital utilization and current density vs. efficiency in variable electricity markets

To achieve low-cost hydrogen production from water electrolyzers, grid tied electrolysis may need to operate dynamically to minimize the cost of supplying energy to the electrolyzer stack and produce hydrogen during low-cost hours and turn off/down during high-cost hours. Operating systems in this way can decrease capital utilization (capacity factor) and electricity costs. This strategy would shift the dominant cost drivers away from electricity (and thus efficiency) to the capital costs of the system, due to the underutilized capital when operating at low-capacity factors. Increasing the operational current density of the system could, in effect, reduce the capital cost of the system while producing hydrogen at a lower efficiency on a per unit energy basis. In the variable electricity cost profiles analyzed in this paper, increasing the current density for liquid alkaline from 0.5 A/cm2 to 1.5 Ac/m2 and proton exchange membrane electrolyzers from 2 A/cm2 to 4 A/cm2 resulted in substantial reductions in the levelized cost of hydrogen. Additionally, as capacity factors and electricity costs decrease, the optimal operating current density of the electrolyzer systems analyzed increases. These findings suggest R&D efforts should focus on increasing the operational current densities, reducing the turn down ratios, and understanding the durability implications of those strategies on low-temperature liquid alkaline and proton exchange membrane electrolyzers.

08 HYDROGEN↗

Heat Storage Coupled to Generation IV Reactors for Variable Electricity from Base-load Reactors: Workshop Proceedings. Changing markets, technology, nuclear-renewables integration and synergisms with solar thermal power systems

Electricity markets are changing because of (1) the addition of wind and solar that creates volatile electricity prices including times of zero-priced electricity and (2) the goal of a low-carbon world that requires replacing fossil fuels that provide (a) energy, (b) stored energy, and (c) dispatchable energy. Wind and solar provide energy but not the other two other energy functions that are provided fossil fuels. Nuclear energy with heat storage can provide all three functions and thus replace fossil fuels.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Impacts of long-term temperature change and variability on electricity investments

Long-term temperature change and variability are expected to have significant impacts on future electric capacity and investments. This study improves upon past studies by accounting for hourly and monthly dynamics of electricity use, long-term socioeconomic drivers, and interactions of the electric sector with rest of the economy for a comprehensive analysis of temperature change impacts on cooling and heating services and their corresponding impact on electric capacity and investments. Using the United States as an example, here we show that under a scenario consistent with a socioeconomic pathway 2 (SSP2) and representative concentration pathway 8.5 (RCP 8.5), mean temperature changes drive increases in annual electricity demands by 0.5-8% across states in 2100. But more importantly, peak temperature changes drive increases in capital investments by 3-22%. Moreover, temperature-induced capital investments are highly sensitive to both long-term socioeconomic assumptions and spatial heterogeneity of fuel prices and capital stock characteristics, which underscores the importance of a comprehensive approach to inform long-term electric sector planning.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analysis of Correlation between Cold Weather Meteorological Variables and Electricity Outages

The significance of the impact of weather on the electric grid has grown as climate change continues to increase the frequency and intensity of extreme weather events. In recent years (2021-2022) in particular, extreme winter weather has affected the grid in locations in the US rarely exposed to extreme low temperatures, snow and icing conditions. Here we analyze the correlation between cold weather meteorological variables and electricity outages during two large winter storm events, Uri (February 2021) and Landon (February 2022) using Random Forest machine learning and Pearson’s correlation coefficient. Our geographical focus across the two storms is the state of Texas. Extrapolation of the method to winter weather impacts over other years and additional locations is proposed.

Dumas, Melissa↗

Spatiotemporal Variability of Electric System Reliability Metrics

As urbanization continues to grow, urban density also rises, placing significant stress on critical infrastructure. Cities often face challenges in investing in new infrastructure or upgrading existing ones. One area of infrastructure that has come under strain is the electric grid, leading to prolonged power outages. According to data from the U.S. Energy Information Administration, the average duration of power outages has steadily doubled from 2013 to 2021, primarily due to extreme weather events. The IEEE has developed a series of reliability metrics to assess the reliability of the electric system. However, these metrics are only applied at the utility level, making it challenging to comprehend the variations in these indices at finer spatial resolutions and, consequently, evaluate reliability at the non-utility level. In this study, we leveraged electric outage data collected at 15-minute intervals at the county level to estimate electric system reliability over a six-year period using a novel data analysis approach. Our findings reveal a gradual decline in reliability in the U.S. Southwest compared to national averages. Furthermore, the duration of outages per customer per event has significantly decreased in large portions of California and Florida. These discoveries can be valuable for utility companies as they seek to pinpoint regional anomalies and plan for prioritized remediation efforts.

Singh, Nagendra↗

Low-cost crushed-rock heat storage with oil or salt heat transfer

The demand for variable electricity and heat is met by fossil-fuel power plants because the power plant capital costs and the cost of storing fossil fuels are low. A low-carbon economy requires replacement of the storage function of fossil fuels to provide variable heat and electricity as needed. The Crushed Rock Ultra-large Stored Heat (CRUSH) system is a new technology with the goal to provide heat storage at an incremental capital cost of $2–4/kWh at scales of 10 s to 100 s of GWhs that enables economic daily to multi-week storage. CRUSH can be coupled to nuclear power plants, concentrated solar power (CSP) plants and thermal energy batteries to provide variable electricity and heat on demand. Sensible heat is stored in crushed rock—the lowest-cost heat-storage material. Heat is transferred to and from the crushed rock using nitrate salt or heat-transfer oils but these fluids do not store heat. Heat from a nuclear reactor, CSP plant or conversion of low-price electricity into heat is used to heat the salt or oil. The hot fluid is poured over the crushed rock, trickles downward by gravity through the rock, heats the rock and is collected by the drain pans under the crushed rock. To recover heat cold salt or oil is poured over hot crushed rock, trickles down by gravity while being heated and is collected by the drain pans under the crushed rock. The system design and engineering trade-offs are described. The technology is in the early stages of development.

20 FOSSIL-FUELED POWER PLANTS↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improving Dynamic Wireless Charging System Performance For Electric Vehicles Through Variable Speed Limit Control Integration

Electric Vehicle (EV) charging has been a significant barrier to the widespread use of EVs. Traditional EV charging methods depend on cables, and there are concerns about safety, accessibility, convenience, and weather. A recent development, dynamic (or in-motion) wireless charging, enables EVs to charge wirelessly by incorporating charging infrastructure into roadways, allowing EVs to charge while moving. However, the energy transferred relies heavily on vehicle speed and time spent in the charging lane. This paper proposes an innovative solution that combines dynamic wire-less charging with Variable Speed Limit (VSL) control. This dynamic traffic control strategy adjusts speed limits based on real-time traffic, weather, and incidents. This integration of dynamic wireless charging and VSL has two potential benefits. First, it can motivate driver compliance with VSL through the incentive of charging. Second, it can promote smoother traffic flow and improve traffic safety by implementing lower speed limits at certain times. To verify these benefits, microscopic traffic simulations in SUMO were conducted under different EV penetration rates and VSL compliance rates. Simulation results reveal that the proposed approach can enhance dynamic wireless charging system performance while improving traffic flow and safety.

Xu, Guanhao [ORNL] (ORCID:0000000214326357)↗

Liquid Alkaline Water Electrolyzers: Comparing Performance across Design, Operation, and End-of-Life Scenarios

Liquid alkaline water electrolysis (LAWE) is a demonstrated technology for hydrogen production, yet a comprehensive life cycle assessment (LCA) of their deployment is lacking. Research leading to improvements to the core component, the electrochemical stack, along with auxiliary system materials and dynamic operation of stacks from variable electricity supply offers new data that allows for detailed modeling and evaluation. Here, we present an LCA of two facility designs based on the current state-of-the-art stack and an advanced stack with zero-gap between electrodes, and capture dynamic electricity use from solar, wind, and hybrid sources and stack recycling strategies. We present life cycle impact factors characterizing the production of 1 kg of hydrogen across 12 environmental, human health, and resource impact categories (TRACI and ReCiPe) in the contiguous United States. As expected, the source of electricity will drive impacts (e.g., 83-94% of carbon intensity); however, we find that operating using wind electricity can lower hydrogen leakage and the overall carbon intensity (1.03 kgCO 2 e/kgH 2 ) relative to solar electricity (2.57 kgCO 2 e/kgH 2 ) at matched 1:1 capacity between LAWE and the electricity source. The deployment of the advanced design and stack recycling lowers impacts across all life cycle stages. We highlight opportunities to further reduce potential impacts, including the balance of plant materials and operation cycles associated with the use of variable wind and solar electricity that result in hydrogen leakage.

08 HYDROGEN↗

Baja California Sur Renewable Integration Study

The goal of the Baja California Sur Renewable Integration Study (BAJA-RIS) is to evaluate the potential impacts of increasing penetrations of wind and solar power on Baja California Sur's bulk power system operations. Studying the impact of wind and solar power on power system operations is interesting and challenging because of the variable and uncertain nature of wind and solar resources. Baja California Sur is a very interesting and relevant region to study renewable integration impacts because its power system is an electrical island; most of its electricity is generated by burning expensive imported fossil fuels (oil and diesel), making it the power system in Mexico with the highest electricity variable generation costs and the most polluting; its electricity consumption is expected to grow significantly; and it has significant renewable energy resource potential in terms of wind power and especially in terms of solar power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electricity Pricing aware Deep Reinforcement Learning based Intelligent HVAC Control

Recently, deep reinforcement learning (DRL) based intelligent control of Heating, Ventilation, and Air Conditioning (HVAC) has gained a lot of attention due to DRL's ability to optimally control HVAC for minimizing operational cost while maintaining resident's comfort. The success of such DRL-based techniques largely depends on the articulation of the problem in terms of states, actions, and reward function. Inclusion of the electricity pricing information in the problem formulation can play an important role in saving the cost of HVAC operation. However, less attention has been given in the literature on formulating well-crafted state features based on electricity pricing. In this work, we propose an approach for training the DRL model with a specific focus on feature engineering based on electricity pricing. During training, we generate random but sufficiently realistic electricity price signals so that the pre-trained DRL model is robust and adaptive to the dynamic and variable electricity prices. The validation results are encouraging and show the potential of ≈12%-15% savings in the one day cost of HVAC operation, proving the usefulness of including electricity pricing related features as state features.

Kurte, Kuldeep↗

Hydrogen Storage for Load-Following and Clean Power: Duct-firing of Hydrogen to Improve the Capacity Factor of NGCC Plants (Final Report, Phase I Conceptual Study)

The 12-month Feasibility study in Phase I study was completed and confirmed the system is feasible and the proposed system is an improvement over alternate low carbon dispatchable power options. Our demonstration will include 54 MWh of hydrogen storage. CO 2 capture inherent to the CHG process can capture 90% of the CO 2 (with upgrades to >98%) in a commercial system (~300 MWth) for sequestration or other uses. The hydrogen will be utilized in a duct burner in a Heat Recovery Steam Generator (HRSG) integrated with the existing Southern Company fossil asset. Here, the firing rate of the duct burner is varied to let the plant respond to fluctuations of electrical load. However, H 2 production is relatively constant by storing H 2 , and revenues are improved by arbitrage between use of low-cost off-peak variable electricity generation or use of stored H 2 under peak demand. The study enabled the fidelity of the concept to be improved and allowed identification of the requirements for the system. Defining the individual system and component requirements was performed via system requirements review with the whole team. These requirements were then incorporated into/iterated with our Heat & Mass Balance models and process flow diagrams were generated to reflect the overall system. This information was then used to complete the TEA and show economic feasibility. Our system generates power at 17.4% lower cost than other low carbon approaches for the H 2 generation, H 2 compression and storage, carbon sequestration, and HRSG added electricity production for a large-scale duct-fired system. Our team recommends completing the Phase II Pre-FEED study for the proposed system as the next step for the project and its tasks will achieve the overall objective and be ready to launch the FEED. The Pre-FEED tasks include updating the requirements, Concept of Operations, plant scope/process description, component modeling, system modeling, performance estimates, emission estimates, block flow diagrams, fluid/process conditions (PFD), utility usage, and facility sizing/definition. The approach will be to complete these updates in a greater level of detail for the selected site. The approach for developing the EIV is to use the updated results, including model outputs, for carbon dioxide and waste streams.

03 NATURAL GAS↗

Network Optimization of the Electrosynthesis of Chemicals from CO2

Carbon dioxide electroreduction (ECO2R) is gaining attention due to its capacity to mitigate CO2 emissions while using electricity that would otherwise be curtailed. Its foreseeable industrial implementation requires of holistic methods to assess the technological and economic performance of ECO2R processes and integrate them in current chemical supply chains and power systems. Here, we combine techno-economic assessment and mathematical programming to find the optimal paths to electroreduce CO2 into valuable chemicals under variable electricity prices. The proposed approach is tested with a case study addressing the CO2 capture from flue gas or direct air and its electricity-powered reduction into carbon monoxide, formic acid or multi-carbon compounds. The results obtained demonstrate the ability of the framework to build ECO2R networks and provide operation profiles that respond to fluctuating electricity prices.

carbon dioxide↗

Simulink Model of a New Energy EVG-005 5kW Hydropower Turbine

Simulink model for a New Energy 5kW hydropower turbine. ADCP data ("ds_streamwise_7_13.nc") and DC voltage, DC current, and rotor rotation observed from the New Energy EVG-005 Current Energy Converter (CEC) ("electrical_7_13_10ohms.nc") were collected at the Tanana River Test Site (TRTS) near Nenana Alaska. - Data was collected on July 13th, 2023 with a constant 10 ohms resistance applied with a DC load bank. - Simulink model is meant to resemble the electrical setup at the TRTS. - Model is initialized by running the "NewEnergy_2023_10hz.m" Matlab script. Then the Simulink model ("New_Energy_Model_PMSM.slx") can be run. - Results are processed with the "NewEnergy_2023_processing.m" Matlab code. The Matlab results are also saved in the "New_Energy_7_13_model_validation_results.mat" Matlab file. This can be directly loaded into the Matlab Workspace using the "Load()" command. - The timetable variables "electrical_model_downsampled" is the model results and the "electrical_limited" is the experimental data from the TRTS.

16 TIDAL AND WAVE POWER↗

Design and Operation of a Sensible Heat Peaking Unit for Small Modular Reactors

Approximately 19% of the electricity produced in the United States comes from nuclear power plants. Traditionally, nuclear power plants, as well as larger coal-fired plants, operate in a baseload manner at or near steady-state for prolonged periods of time. Smaller, more maneuverable plants, such as gas-fired plants, are dispatched to match electricity supply and demand above the capacity of the baseload plants. However, air quality concerns and CO2 emission standards has made the burning of fossil fuels less desirable, despite the current low cost of natural gas. Wind and solar photovoltaic (PV) power generation are attractive options due to their lack of carbon footprint and falling capital costs. Yet, these renewable energy sources suffer from inherent intermittency. This inherent intermittency can strain electric grids, forcing carbon-based and nuclear sources of energy to operate in a load follow mode. For nuclear reactors, load follow operation can be undesirable due to the associated thermal and mechanical stresses placed on the fuel and other reactor components. Various methods of Thermal Energy Storage (TES) can be coupled to nuclear (or renewable) power sources to help absorb grid variability caused by daily load demand changes and renewable intermittency. Our previous research has shown that coupling a sensible heat TES system to a Small Modular Reactor (SMR) allows the reactor to run at effectively nominal full power during periods of variable electric demand by bypassing steam to the TES system during periods of excess capacity. In this study we demonstrate that this stored thermal energy can be recovered, allowing the TES system to act as a peaking unit during periods of high electric demand, or used to produce steam for ancillary applications such as desalination. For both applications the reactor is capable of operating continuously at approximately 100% power.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗