Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrical Port”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Modeled Electricity Demand Profiles for Electric Port Cargo Handling Equipment in the United States

Electric port cargo handling equipment (eCHE) hourly load datasets for the top 25 U.S. cargo airports (by tonnage), as described in Polemis et al. (2025). Please cite as: Polemis, Katerina, Andrew Kotz, Kara Podkaminer, and Brennan Borlaug. 2025. Hourly Load Profile Dataset for Electric Port Cargo Handling Equipment in the United States. Golden, CO: National Renewable Energy Laboratory. NREL/TP-5400-92141. https://www.nlr.gov/docs/fy25osti/92141.pdf

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hourly Load Profile Dataset for Electric Port Cargo Handling Equipment in the United States

Historically, ports have relied on fossil fuels, particularly diesel, as their primary energy source. Transitioning to electric cargo handling equipment (eCHE) offers a promising solution, as this relatively mature technology eliminates tailpipe emissions, reduces harmful airborne particulates, lowers noise pollution, and supports decarbonization. This study develops an initial estimation of hourly electricity demand for eCHE at the top 25 container ports (by tonnage) in the United States. These datasets, accessible at data.nrel.gov/submissions/281, provide valuable insights into the electricity demand patterns and potential grid impacts associated with widespread eCHE adoption, forming a foundation for future refinement based on stakeholder feedback.

33 ADVANCED PROPULSION SYSTEMS↗

Checking Plumbing Connections Electrically

Ports identified by Zener-diode voltages. Electronic verification circuits assist in assembly of multiple-line plumbing by helping to ensure proper lines joined to proper input and output ports. Zener diode and electronic jack added to each fixture. Zener breakdown voltage is different for each port. When fixture makes fluid connection, also makes electrical connection. Zener breakdown voltage identifies line, port, or valve to which fluid line connected.

Chappel, Jerry L.↗

Electrical Power System Sizing Within the Numerical Propulsion System Simulation

Electrified aircraft propulsion seeks to address ambitious goals in the commercial airline industry, including significant decreases in fuel burn, emissions, noise, and takeoff field length. In order to move these electrified propulsion concepts forward, analysis tools are needed that can model propulsion systems containing both gas turbine and power system components. This work presents the definition of an electric port, a set of electrical power systems tools, and simulation examples for the Numerical Propulsion System Simulation (NPSS) software. NPSS is the industry standard modeling and simulation package for aircraft propulsion systems, and the ability to design, size, integrate, and analyze electric power systems will enable industry efforts towards the development of electrified aircraft propulsion.

aircraft electrification↗

DOE Zero Energy Ready Home Case Study HIA 2020: United Way of Long Island, Net Positive All Electric Home, Port Jefferson Station, NY

Case study of a DOE 2020 Housing Innovation Award winning custom home in a mixed-humid climate that got a HERS -2 with PV, with 2,500 square feet, featuring a novel attic truss specifically designed to accommodate a ducted mini-split heat pump tucked into an insulated chase in the vented attic. The walls are constructed of 2x6 studs installed at 24 inches on center and incorporating advanced framing techniques to reduce the amount of lumber needed and to provide more room for insulation.

Building America, residential construction, home b↗

6-ft High-Power Electric Propulsion Test Port, EPL Tank 5 Installed

High-power electric propulsion is a critical component of NASA s proposed missions to the outer planets. Mission studies have shown that high-power, high-specific-impulse propulsion systems can deliver 2000 kg of scientific payload to Pluto with trip times on the order of 10 years. Of greater significance is the ability of these propulsion systems to place this science payload in orbit around the planet, rather than making the fast fly-bys associated with traditional chemical propulsion systems. Significant ground test programs are required to develop the new technologies needed for thrusters operating at power levels exceeding 20 kW, an order of magnitude above the state of the art.

Grisnik, Stanley P.↗

EMOS (Energy Management Optimization System) [SWR-21-46]

EMOS software performs a real-time hierarchal optimal control for energy systems like multi-port electric vehicles charging site with distributed energy resources (DERs) and energy storage systems (ESSs). It gathers information in real-time from electric vehicles, power grid, and DERs, solves a multi-objective energy management optimization problem, and output setpoint for chargers, ESS converters, DERs converters, and grid converters. The software incorporates a novel integration of two control tasks: a) An Energy Management Optimization (EMO), which is the brain of EMOS controller that gathers information in real-time from EVs [e.g., battery size, state-of-charge (SOC), desired SOC, and charge acceptance curve], grid (e.g., electricity price, allowed feeder capacity, ramp rate limit, and reactive power), and DERs (e.g., prediction for solar generation for PV systems). It solves a control optimization problem in real-time to find optimal setpoint for ESSs power dispatch, EVs charging rate, and grid inverters. The objectives are to (1) minimize the charging cost considering grid energy, demand charges, and battery energy, (2) minimize charging time to meet fast charging criterion, (3) keep high energy level on ESSs at the end of an operating period, while satisfying constraints related to grid, EVs, and power converters. b) Real-Time Energy Management System (RT-EMS) is a rule-based algorithm that has faster response than EMO. It receives optimal setpoint from EMO and actual measurements from the system and modify the setpoint to compensate for any fast disturbance in the system, until a new optimum solution is received. Fast disturbances may include vehicle connect/disconnect, unpredicted variation in DERs profiles, variation in grid voltage, errors in PV generation prediction, and others. In addition, RT-EMS regulates voltage at point of common coupling (PCC) by managing reactive power of grid converters.

Mohamed, Ahmed↗

My vehicle is a data mine

In this talk we explore how analysis of vehicle data provides information of individual vehicle behaviors, information of other vehicles in the flow of traffic, and insights into the behavior of drivers. Over the last two decades traditional passenger vehicles have been transformed from integrated two-port electrical nodes to cyber-physical systems of communicating computational nodes whose individual state and control variables are shared on a standard controller area network (CAN) bus. As driver assistance systems have crept into vehicles as safety features, driver behaviors can be observed through analysis of the data streams on the CAN bus as these new nodes communicate with one another. The properties of these data streams, as well as architectures and approaches to gather the data, are important to consider when drawing conclusions on the relevance of the data in making decisions at varying levels of the information hierarchy. We will demonstrate several technical challenges associated with these data collection processes, as well as preliminary results that demonstrate application relevance of the data to behavior, traffic, and systems domains.

42 ENGINEERING↗

A Novel Photonic Clock and Carrier Recovery Device

As data communication rates climb toward ten Gb/s, clock recovery and synchronization become more difficult, if not impossible, using conventional electronic circuits. We present in this article experimental results of a high speed clock and carrier recovery using a novel device called a photonic oscillator that we recently developed in our laboratory. This device is capable of recovering clock signals up to 70 GHz. To recover the clock, the incoming data is injected into the photonic oscillator either through the optical injection port or the electrical injection port. The free running photonic oscillator is tuned to oscillate at a nominal frequency equal to the clock frequency of the incoming data. With the injection of the data, the photonic oscillator will be quickly locked to clock frequency of the data stream while rejecting other frequency components associated with the data. Consequently, the output of the locked photonic oscillator is a continuous periodical wave synchronized with the incoming data or simply the recovered clock. We have demonstrated a clock to spur ratio of more than 60 dB of the recovered clock using this technique. Similar to the clock recovery, the photonic oscillator can be used to recover a high frequency carrier degraded by noise and an improvement of about 50 dB in signal-to-noise ratio was demonstrated. The photonic oscillator has both electrical and optical inputs and outputs and can be directly interfaced with a photonic system without signal conversion. In addition to clock and carrier recovery, the photonic oscillator can also be used for (1) stable high frequency clock signal generation, (2) frequency multiplication, (3) square wave and comb frequency generation, and (4) photonic phase locked loop.

Yao, X. Steve↗

Hardening communication ports for survival in electrical overstress environments

Greater attention is being focused on the protection of data I/O ports since both experience and lab tests have shown that components at these locations are extremely vulnerable to electrical overstress (EOS) in the form of transient voltages. Lightning and electrostatic discharge (ESD) are the major contributors to these failures; however, these losses can be prevented. Hardening against transient voltages at both the board level and system level has a proven record of improving reliability by orders of magnitude. The EOS threats, typical failure modes, and transient voltage mitigation techniques are reviewed. Case histories are also reviewed.

Clark, O. Melville↗

Device having hybrid hydraulic-electric architecture

A device having a hybrid hydraulic-electric architecture includes a hydraulic pump/motor having first and second ports, and an electric motor. The device is configured to connect to two or more pressure rails, each pressure rail containing hydraulic fluid at a different pressure than the other pressure rails. A flow of hydraulic fluid from one of the pressure rails is driven through the hydraulic pump/motor, and a pressure difference exists between the first and second ports. The electric motor is configured to control a flow rate of the flow of hydraulic fluid and/or the pressure difference.

Li, Perry Yan-Ho↗

Electrical Characterization of Hughes HCMP 1852D and RCA CDP1852D 8-bit, CMOS, I/O Ports

Twenty-five Hughes HCMP 1852D and 25 RCA CDP1852D 8-bit, CMOS, I/O port microcircuits underwent electrical characterization tests. All electrical measurements were performed on a Tektronix S-3260 Test System. Before electrical testing, the devices were subjected to a 168-hour burn-in at 125 C with the inputs biased at 10V. Four of the Hughes parts became inoperable during testing. They exhibited functional failures and out-of-range parametric measurements after a few runs of the test program.

Stokes, R. L.↗

Concepts to Automate Fluid Transfer Capability of Low Impact Docking System (LIDS)

The capability to transfer mass between spacecraft is necessary for many mission scenarios. Docking and berthing operations have enabled fluid, electrical, crew and equipment transfers to some degree on all manned space operations since the Gemini program. The Apollo program performed some sophisticated docking maneuvers to land men on the moon and return them safely to Earth. These programs primarily transferred crew, equipment, and pressurized atmosphere between docked spacecraft. The International Space Station (ISS) U.S. modules are connected by Common Berthing Mechanism (CBM) portals. They provide many feed-through ports for electrical, and fluid transfer between modules, as well as a large diameter crew and equipment tunnel. Fluid and electrical jumpers are manually installed after the CBM sealing surfaces have been securely mated to maintain the pressurized cabin environment. CBM berthing and subsequent fluid transfer capability requires a lengthy manual process involving an active interface that mates with a passive half. The Androgynous Peripheral Attach System (MAS) a Russian technology that docked the Russian Zarya module to Unity, or Node 1, is a more complex system that also is capable of fuel transfer, enabling refueling of the Russian re-boost engines on ISS. For several years, a Low Impact Docking System (LIDS) has been under development at Johnson Space Center (JSC). This docking technology has a requirement to be androgynous in order to allow the fabrication of a single configuration that can dock with all other LIDS units. It is desired to make electrical and fluid coupling mating an automated process to enable routine docking and undocking operations to support future exploration missions. It is envisioned that modular design and vehicle assembly will require an efficient LIDS for fuel, electrical, crew, and equipment transfer. Marshall Space Flight Center (MSFC) has joined the LIDS development effort and plans to employ fluid transfer concepts and technology from previous development programs, such as the Automated Fluid Interface System (AFIS) and the Ohital Fluid Transfer System (OFTS) that were developed and tested by MSFC. Orbital Expressderived robotic satellite servicing technology is scheduled to fly soon to demonstrate fluid transfer technology developed for the Air Force. This paper will compare known technology against possible fluid transfer requirements for LIDS to develop design strategies for automated fluid transfer.

Miernik, Janie H.↗

Use of SX Series Devices and IEEE 1149.1 JTAG Circuitry

This report summarizes the use of SX series devices and their JTAG 1149.1 circuitry. 'JTAG' circuitry was originally designed to standardize testing of boards via a simple control port interface electrically without having to use devices such as a bed of nails tester. JTAG is also used for other functions such as executing built-in-test sequences, identifying devices, or, through custom instructions, other functions designed in by the chip designer. The JTAG circuitry is designed for test only; it has no functional use in the integrated circuit during normal operations. The JTAG circuitry and the mode of the device is controlled by a circuit block known as the 'TAP controller,' which is a sixteen-state state machine along with various registers. The controller is normally in an operational state known as TEST-LOGIC-RESET. In this state, the device is held in a fully functional, operating mode. However, a Single Event Upset (SEU) may remove the TAP controller from this state, causing a loss of control of the integrated circuit, unless certain precautions are taken, such as grounding the optional JTAG TRST signal.

Katz, Richard B.↗

Use of SX Series Devices and IEEE 1149.1 JTAG Circuitry

This report summarizes the use of SX series devices and their JTAG 1149.1 circuitry. 'JTAG' circuitry was originally designed to standardize testing of boards via a simple control port interface electrically without having to use devices such as a bed of nails tester. JTAG is also used for other functions such as executing built-in-test sequences, identifying devices, or, through custom instructions, other functions designed in by the chip designer. The JTAG circuitry is designed for test only; it has no functional use in the integrated circuit during normal operations. The JTAG circuitry and the mode of the device is controlled by a circuit block known as the 'TAP controller,' which is a sixteen-state state machine along with various registers. The controller is normally in an operational state known as TEST-LOGIC-RESET. In this state, the device is held in a fully functional, operational mode. However, a Single Event Upset (SEU) may remove the TAP controller from this state, causing a loss of control of the integrated circuit, unless certain precautions are taken, such as grounding the optional JTAG TRST signal.

Katz, Richard B.↗

GIS Supported Optimal Site Selection for Coastal Structure Integrated Wave Energy Converters: Preprint

There is an urgent need for adaptative engineering towards more resilient coastal communities, and Coastal Structure Integrated Wave Energy Converters (CSI-WECs) are a promising solution. CSI-WECs are wave energy converters (WECs) that are built into coastal protection structures, such as breakwaters. These devices provide the dual benefits of coastal protection and local energy production, and unlike other WECs, maximizing energy production is not always the main objective. CSI-WECs are located near the shore, where the wave resource is lower, thus site selection for these devices differs from the typical offshore WECs. Other attributes of a site that may be more important than wave power include existing coastal structures, port proximity, electric transmission line proximity, and location of disadvantaged communities. Geospatial information systems (GIS) interfaces can be used to easily visualize geospatial data that represents these difference kinds of criteria important for the determination of optimal marine energy sites. Multi-Criteria Decision Analysis (MCDA) is a geospatial analysis method that allows for the evaluation of multiple, usually overlapping, criteria. This project applies GIS-based MCDA methods to two distinct case studies in Puerto Rico and California for CSI-WEC site selection. The two study sites contrast in terms of wave resource, coastal hazards, and local energy needs. This research demonstrates the utility of applying an MCDA framework within GIS to facilitate efficient site selection for devices with unique characteristics in different use cases.

coastal protection↗