Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrocardiography/methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Real-Time 12-Lead High-Frequency QRS Electrocardiography for Enhanced Detection of Myocardial Ischemia and Coronary Artery Disease

Several studies have shown that diminution of the high-frequency (HF; 150-250 Hz) components present within the central portion of the QRS complex of an electrocardiogram (ECG) is a more sensitive indicator for the presence of myocardial ischemia than are changes in the ST segments of the conventional low-frequency ECG. However, until now, no device has been capable of displaying, in real time on a beat-to-beat basis, changes in these HF QRS ECG components in a continuously monitored patient. Although several software programs have been designed to acquire the HF components over the entire QRS interval, such programs have involved laborious off-line calculations and postprocessing, limiting their clinical utility. We describe a personal computer-based ECG software program developed recently at the National Aeronautics and Space Administration (NASA) that acquires, analyzes, and displays HF QRS components in each of the 12 conventional ECG leads in real time. The system also updates these signals and their related derived parameters in real time on a beat-to-beat basis for any chosen monitoring period and simultaneously displays the diagnostic information from the conventional (low-frequency) 12-lead ECG. The real-time NASA HF QRS ECG software is being evaluated currently in multiple clinical settings in North America. We describe its potential usefulness in the diagnosis of myocardial ischemia and coronary artery disease.

Software↗

Usefulness of microvolt T-wave alternans for prediction of ventricular tachyarrhythmic events in patients with dilated cardiomyopathy: results from a prospective observational study

OBJECTIVES: This study was designed to evaluate the ability of microvolt-level T-wave alternans (MTWA) to identify prospectively patients with idiopathic dilated cardiomyopathy (DCM) at risk of ventricular tachyarrhythmic events and to compare its predictive accuracy with that of conventional risk stratifiers. BACKGROUND: Patients with DCM are at increased risk of sudden death from ventricular tachyarrhythmias. At present, there are no established methods of assessing this risk. METHODS: A total of 137 patients with DCM underwent risk stratification through assessment of MTWA, left ventricular ejection fraction, baroreflex sensitivity (BRS), heart rate variability, presence of nonsustained ventricular tachycardia (VT), signal-averaged electrocardiogram, and presence of intraventricular conduction defect. The study end point was either sudden death, resuscitated ventricular fibrillation, or documented hemodynamically unstable VT. RESULTS: During an average follow-up of 14 +/- 6 months, MTWA and BRS were significant univariate predictors of ventricular tachyarrhythmic events (p < 0.035 and p < 0.015, respectively). Multivariate Cox regression analysis revealed that only MTWA was a significant predictor. CONCLUSIONS: Microvolt-level T-wave alternans is a powerful independent predictor of ventricular tachyarrhythmic events in patients with DCM.

Evaluation Studies↗

Complex patterns of abnormal heartbeats

Individuals having frequent abnormal heartbeats interspersed with normal heartbeats may be at an increased risk of sudden cardiac death. However, mechanistic understanding of such cardiac arrhythmias is limited. We present a visual and qualitative method to display statistical properties of abnormal heartbeats. We introduce dynamical "heartprints" which reveal characteristic patterns in long clinical records encompassing approximately 10(5) heartbeats and may provide information about underlying mechanisms. We test if these dynamics can be reproduced by model simulations in which abnormal heartbeats are generated (i) randomly, (ii) at a fixed time interval following a preceding normal heartbeat, or (iii) by an independent oscillator that may or may not interact with the normal heartbeat. We compare the results of these three models and test their limitations to comprehensively simulate the statistical features of selected clinical records. This work introduces methods that can be used to test mathematical models of arrhythmogenesis and to develop a new understanding of underlying electrophysiologic mechanisms of cardiac arrhythmia.

Non-NASA Center↗

Variability in surface ECG morphology: signal or noise?

Using data collected from canine models of acute myocardial ischemia, we investigated two issues of major relevance to electrocardiographic signal averaging: ECG epoch alignment, and the spectral characteristics of the beat-to-beat variability in ECG morphology. With initial digitization rates of 1 kHz, an iterative a posteriori matched filtering alignment scheme, and linear interpolation, we demonstrated that there is sufficient information in the body surface ECG to merit alignment to a precision of 0.1 msecs. Applying this technique to align QRS complexes and atrial pacing artifacts independently, we demonstrated that the conduction delay from atrial stimulus to ventricular activation may be so variable as to preclude using atrial pacing as an alignment mechanism, and that this variability in conduction time be modulated at the frequency of respiration and at a much lower frequency (0.02-0.03Hz). Using a multidimensional spectral technique, we investigated the beat-to-beat variability in ECG morphology, demonstrating that the frequency spectrum of ECG morphological variation reveals a readily discernable modulation at the frequency of respiration. In addition, this technique detects a subtle beat-to-beat alternation in surface ECG morphology which accompanies transient coronary artery occlusion. We conclude that physiologically important information may be stored in the variability in the surface electrocardiogram, and that this information is lost by conventional averaging techniques.

NASA Discipline Cardiopulmonary↗

Signal averaging technique for noninvasive recording of late potentials in patients with coronary artery disease

An advanced non invasive signal averaging technique was used to detect late potentials in two groups of patients: Group A (24 patients) with coronary artery disease (CAD) and without sustained ventricular tachycardia (VT) and Group B (8 patients) with CAD and sustained VT. Recorded analog data were digitized and aligned using a cross correlation function with fast Fourier transform schema, averaged and band pass filtered between 60 and 200 Hz with a non-recursive digital filter. Averaged filtered waveforms were analyzed by computer program for 3 parameters: (1) filtered QRS (fQRS) duration (2) interval between the peak of the R wave peak and the end of fQRS (R-LP) (3) RMS value of last 40 msec of fQRS (RMS). Significant change was found between Groups A and B in fQRS (101 -/+ 13 msec vs 123 -/+ 15 msec; p < .0005) and in R-LP vs 52 -/+ 11 msec vs 71-/+18 msec, p <.002). We conclude that (1) the use of a cross correlation triggering method and non-recursive digital filter enables a reliable recording of late potentials from the body surface; (2) fQRS and R-LP durations are sensitive indicators of CAD patients susceptible to VT.

NASA Discipline Cardiopulmonary↗

Computer simulation of fibrillation threshold measurements and electrophysiologic testing procedures

A finite element model of cardiac conduction was used to simulate two experimental protocols: 1) fibrillation threshold measurements and 2) clinical electrophysiologic (EP) testing procedures. The model consisted of a cylindrical lattice whose properties were determined by four parameters: element length, conduction velocity, mean refractory period, and standard deviation of refractory periods. Different stimulation patterns were applied to the lattice under a given set of lattice parameter values and the response of the model was observed through a simulated electrocardiogram. The studies confirm that the model can account for observations made in experimental fibrillation threshold measurements and in clinical EP testing protocols.

NASA Discipline Cardiopulmonary↗

Clinical utility of T-wave alternans

Electrical alternans represents a variation in the morphology of electrocardiographic complexes on an every-other-beat basis in an ABABAB... pattern. Apparent electrical alternans associated with pericardial effusion results from rotation of the heart in the pericardial sac, and not true alternation in electrical conduction patterns. In contrast, true electrical alternans results from an alternation in electrical conduction patterns in the heart itself. Repolarization alternans is true electrical alternans associated with the ST segment and T wave of the electrocardiogram (ECG). Here we will focus on T-wave alternans (TWA) and its association with susceptibility to ventricular tachyarrhythmias. Electrical alternans was reported in the literature as early as 1909. Historically, electrical alternans has been regarded as a fairly rare electrocardiographic abnormality. Case reports of electrical alternans have been associated with a variety of disease states, including acute ischemia, Prinzmetal's angina, a variety of electrolyte abnormalities, and the long QT syndrome. Interestingly, patients born with the prolonged QT syndrome have a very high incidence of sudden cardiac death at an early age. Schwartz and Malliani showed that patients with the prolonged QT syndrome who do not demonstrate alternans at rest, may evidence alternans during stress such as emotional excitement. Thus, over the years electrical alternans has been associated anecdotally with conditions associated with an increased risk of ventricular arrhythmias. In 1948, Kalter reviewed the world literature on electrical alternans and found a total of 41 reported cases. In addition, he reviewed clinical ectrocardiograms from 6059 patients and found five new cases (incidence of less than 1 in 1000 patients). Interestingly, he found a very high mortality, 62%, associated with this condition. Despite the clinical associations reported in the literature, the consensus view of electrical alternans until recent years has been that alternans is an electrocardiographic curiosity rarely encountered in clinical practice which, when identified, does not have specific clinical significance.

Review, Tutorial↗

[Heart functions in monkeys during a 2-week antiorthostatic hypokinesia]

Dynamics of the left heart ventricular muscle contractility and compliance was studied in 4 monkeys in the head down position (antiorthostatic hypokinesia) with the body angle 10 during 2 weeks. Functional tests on a tilt table and under two conditions of centrifuge rotation were performed prior to and after the antiorthostatic hypokinesia. No changes in the left heart ventricular muscle contractility was found. However, the sensitivity level of the baroreflex control decreased. Compliance of the left heart myocardial fibre increased in the first hours and days of the antiorthostatic hypokinesia.

NASA Discipline Regulatory Physiology↗

Month-to-month and year-to-year reproducibility of high frequency QRS ECG signals

High frequency electrocardiography analyzing the entire QRS complex in the frequency range of 150 to 250 Hz may prove useful in the detection of coronary artery disease, yet the long-term stability of these waveforms has not been fully characterized. Therefore, we prospectively investigated the reproducibility of the root mean squared voltage, kurtosis, and the presence versus absence of reduced amplitude zones in signal averaged 12-lead high frequency QRS recordings acquired in the supine position one month apart in 16 subjects and one year apart in 27 subjects. Reproducibility of root mean squared voltage and kurtosis was excellent over these time intervals in the limb leads, and acceptable in the precordial leads using both the V-lead and CR-lead derivations. The relative error of root mean squared voltage was 12% month-to-month and 16% year-to-year in the serial recordings when averaged over all 12 leads. Reduced amplitude zones were also reproducible up to a rate of 87% and 81%, respectively, for the month-to-month and year-to-year recordings. We conclude that 12-lead high frequency QRS electrocardiograms are sufficiently reproducible for clinical use.

Coronary Disease/diagnosis↗