Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrochemical analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Stamping Nanoparticles onto the Electrode for Rapid Electrochemical Analysis in Microfluidics

Electrochemical analysis is an efficient way to study various materials. However, nanoparticles are challenging due to the difficulty in fabricating a uniform electrode containing nanoparticles. We developed novel approaches to incorporate nanoparticles as a working electrode (WE) in a three-electrode microfluidic electrochemical cell. Specifically, conductive epoxy was used as a medium for direct application of nanoparticles onto the electrode surface. Three approaches in this work were illustrated, including sequence stamping, mix stamping, and droplet stamping. Shadow masking was used to form the conductive structure in the WE surface on a thin silicon nitride (SiN) membrane. Two types of nanomaterials, namely cerium oxide (CeO2) and graphite, were chosen as representative nanoparticles. The as-fabricated electrodes with attached particles were characterized using atomic force microscopy (AFM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). Electrochemical analysis was performed to verify the feasibility of these nanoparticles as electrodes. Nanomaterials can be quickly assessed for their electrochemical properties using these new electrode fabrication methods in a microfluidic cell, offering a passport for rapid nanomaterial electrochemical analysis in the future.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Microfluidic electrochemical device and process for chemical imaging and electrochemical analysis at the electrode-liquid interface in-situ

A microfluidic electrochemical device and process are detailed that provide chemical imaging and electrochemical analysis under vacuum at the surface of the electrode-sample or electrode-liquid interface in-situ. The electrochemical device allows investigation of various surface layers including diffuse layers at selected depths populated with, e.g., adsorbed molecules in which chemical transformation in electrolyte solutions occurs.

36 MATERIALS SCIENCE↗

Microfluidic electrochemical device and process for chemical imaging and electrochemical analysis at the electrode-liquid interface in-situ

A microfluidic electrochemical device and process are detailed that provide chemical imaging and electrochemical analysis under vacuum at the surface of the electrode-sample or electrode-liquid interface in-situ. The electrochemical device allows investigation of various surface layers including diffuse layers at selected depths populated with, e.g., adsorbed molecules in which chemical transformation in electrolyte solutions occurs.

42 ENGINEERING↗

New Techniques for Thermo-electrochemical Analysis of Lithium-ion Batteries for Space Applications

The overall goal of this study was achieved: Replicated the numerical assessment performed by Chen et. al. (2005). Displayed the ability of Thermal Desktop to be coupled with thermo-electrochemical analysis techniques. such that the local heat generated on the cells is a function of the model itself using logic blocks and arrays. Differences in the TD temperature vs. depth of discharge profiles and Chen's was most likely due to differences in two primary areas: Contact regions and conductance values. Differences in density and specific heat values. center dot The model results are highly dependent on the accuracy of the material properties with respect to the multiple layers of an individual cell.

Walker, William↗

Nanoelectrode array for electrochemical analysis

A nanoelectrode array comprises a plurality of nanoelectrodes wherein the geometric dimensions of the electrode controls the electrochemical response, and the current density is independent of time. By combining a massive array of nanoelectrodes in parallel, the current signal can be amplified while still retaining the beneficial geometric advantages of nanoelectrodes. Such nanoelectrode arrays can be used in a sensor system for rapid, non-contaminating field analysis. For example, an array of suitably functionalized nanoelectrodes can be incorporated into a small, integrated sensor system that can identify many species rapidly and simultaneously under field conditions in high-resistivity water, without the need for chemical addition to increase conductivity.

47 OTHER INSTRUMENTATION↗

Targeted synthesis, characterization, and electrochemical analysis of transition-metal-oxide catalysts for the oxygen evolution reaction

Hydrogen fuel can be produced through the electrochemical splitting of water, an energy-intensive process that requires the use of electrocatalysts to be more efficient. Whereas current precious-metal-based electrocatalysts might be costly on a larger scale, transition-metal-oxide catalysts are more earth abundant and have shown promising activity. Here, the development and improvement of highly active transition-metal-oxide electrocatalysts is thus an important area of study where different catalyst enhancement strategies are used to drive the field forward. Additionally, transition-metal-oxide catalysts come in various different structures with their own advantages; thus, this review is focused on investigating the continuing field of transition-metal-oxide electrocatalysts of different structures and innovative methods of improving activity. By the end, new and promising paths forward in this field will be highlighted, particularly in the development of rock-salt oxides for the water-splitting system.

08 HYDROGEN↗

Design and fabrication of a bending rotation fatigue test rig for in situ electrochemical analysis during fatigue testing of NiTi shape memory alloy wires

The current investigation proposes a novel method for simultaneous assessment of the electrochemical and structural fatigue properties of nickel-titanium shape memory alloy (NiTi SMA) wires. The design and layout of an in situ electrochemical cell in a custom-made bending rotation fatigue (BRF) test rig is presented. This newly designed test rig allows performing a wide spectrum of experiments for studying the influence of fatigue on corrosion and vice versa. This can be achieved by performing ex situ and/or in situ measurements. The versatility of the combined electrochemical/mechanical test rig is demonstrated by studying the electrochemical behavior of NiTi SMA wires in 0.9% NaCl electrolyte under load. The ex situ measurements allow addressing various issues, for example, the influence of pre-fatigue on the localized corrosion resistance, or the influence of hydrogen on fatigue life. Ex situ experiments showed that a pre-fatigued wire is more susceptible to localized corrosion. The synergetic effect can be concluded from the polarization studies and specifically from an in situ study of the open circuit potential (OCP) transients, which sensitively react to the elementary repassivation events related to the local failure of the oxide layer. It can also be used as an indicator for identifying the onset of the fatigue failure.

36 MATERIALS SCIENCE↗

Characterization and Electrochemical Analysis of Acidic Condensate-Induced Corrosion on Aluminized Coating on Steel in Residential Heaters

Condensing furnace residential heaters are starting to replace outdated and less efficient non-condensing units in homes across the US. However, the burning of natural gas in these new units produces acidic gases, which can form acid droplets (H 2 SO 4 , HNO 3 , H 2 CO 3 , etc.) that are corrosive to low-grade heat exchanger metallic materials. Type-1 aluminized steel has been used in industrial applications, such as marine, heating, and automobile parts, due to its resistance to oxidation at elevated temperature. Many components of the condensing furnaces, including heat exchangers, are made from type-1 aluminized steel. We investigated the interaction of type-1 aluminized steel substrates with two acidic condensate liquids by 500 h corrosion exposures as well as short-term electrochemical impedance measurements. SEM plan and cross-sectional view images revealed damage to the Al-Si rich layer and exposure of the steel substrate. The non-uniform damage in the Al-Si rich layer was likely attributed to a pitting corrosion mechanism and induced by high acidity of the condensate liquid. Electrochemical impedance measurements in an acidic condensate revealed lower corrosion resistance of the aluminized steel surface with a weld line, identifying welded sections as preferential corrosion initiation sites.

36 MATERIALS SCIENCE↗

Multiple oxidation states of uranium stabilized by an O , N , O -ligand

Elements of the 5f row maintain a wide variety of oxidation states that have been exploited in synthesis, catalysis, and separations. Herein, we describe the complexation of an O,N,O chelator, ExPh, with uranium in the (IV) and (VI) (uranyl) oxidation states. These two uranium complexes, U(IV)ExPh and UO 2 ExPh, respectively, were characterized in the solid state via single-crystal X-ray diffraction (SC-XRD) analysis. Electrochemical studies using cyclic voltammetry were employed to investigate the multiple redox events associated with the U(IV) complex. Spectro-electrochemical analysis of U(IV)ExPh provided spectroscopic evidence of a stable U(V) species. Chemical oxidation of U(IV)ExPh allowed isolation of the U(V) complex, U(V)ExPh. All three stable uranium complexes produced in this study were characterized via IR, UV-vis and NMR spectroscopies, and micro-spectrophotometry. On the other hand, efforts to reduce U(IV)ExPh to the corresponding U(III) species or produce this putative complex directly from ExPh failed to yield an isolable product. The stabilization of three formal oxidation states of uranium, coupled with previous lanthanide-row results, paves the way for studies of ExPh and its analogues in minor actinide chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Robust Interpretation of Electrochemical Impedance Spectra Using Numerical Complex Analysis

Electrochemical Impedance Spectroscopy (EIS) is a noninvasive technique widely used for understanding charge transfer and charge transport processes in electrochemical systems and devices. Standard approaches for the interpretation of EIS data involve starting with a hypothetical circuit model for the physical processes in the device based on experience/intuition and then fitting the EIS data to this circuit model. This work explores a mathematical approach for extracting key characteristic features from EIS data by relying on fundamental principles of complex analysis. These characteristic features can suggest the presence of inductors and constant phase elements (nonideal capacitors) from impedance data and enable us to answer questions about the identifiability and nonuniqueness of equivalent circuit models. In certain scenarios such as models with only resistors and capacitors, we are able to enumerate all possible families of circuit models. Finally, we apply the mathematical framework presented here to real-world electrochemical systems and highlight results using impedance measurements from a lithium-ion battery coin cell.

charge transfer↗

Investigating the Influence of Ni, ZrO 2 , and Y 2 O 3 from SOFC Anodes on Siloxane Deposition

Siloxanes, as a type of impurity in biogas, can poison the Ni-YSZ anode of SOFCs. However, the influence of individual components of the anode, such as Ni, ZrO 2 , and Y 2 O 3 , on the siloxane deposition process has not been investigated extensively. In this study, Ni, ZrO 2 , and Y 2 O 3 pellets were exposed to H 2 + N 2 + H 2 O + D4 (octamethylcyclotetrasiloxane, 2.5 ppmv) and H 2 + N 2 + D4 (2.5 ppmv siloxane) gas mixtures at 750 °C to investigate their affinity and tolerance for siloxane degradation. Surface morphology analysis and electrochemical analysis including electrochemical impedance spectroscopy (EIS), related distribution of relaxation times (DRT) analysis and equivalent circuit modeling with complex nonlinear least square (CNLS) fitting were conducted. Here, a microstructure parameter—tortuosity factor to porosity ratio $\tau /\varepsilon $ calculated by diffusion polarization resistance was utilized for siloxane deposition evaluation. After comparing pellets surface morphology changes before and after experiments and $\tau /\varepsilon $ change following the contamination, Ni is considered as a major factor in siloxane deposition reactions in Ni-YSZ anode.

25 ENERGY STORAGE↗

Analysis of geometric and electrochemical characteristics of lithium cobalt oxide electrode with different packing densities

In order to investigate geometric and electrochemical characteristics of Li ion battery electrode with different packing densities, lithium cobalt oxide (LiCoO 2 ) cathode electrodes were fabricated from a 94:3:3 (wt%) mixture of LiCoO 2 , polymeric binder, and super-P carbon black and calendered to different densities. A synchrotron X-ray nano-computed tomography system with a spatial resolution of 58.2 nm at the Advanced Photon Source of the Argonne National Laboratory was employed to obtain three dimensional morphology data of the electrodes. The morphology data were then quantitatively analyzed to characterize their geometric properties, such as porosity, tortuosity, specific surface area, and pore size distribution. The geometric and electrochemical analysis reveal that high packing density electrodes have smaller average pore size and narrower pore size distribution, which improves the electrical contact between carbon-binder matrix and LiCoO 2 particles. The better contact improves the capacity and rate capability by reducing the possibility of electrically isolated LiCoO 2 particles and increasing the electrochemically active area. The results show that increase of packing density results in higher tortuosity, but electrochemically active area is more crucial to cell performance than tortuosity at up to 3.6 g/cm 3 packing density and 4 C rate.

25 ENERGY STORAGE↗

A Perspective on Traditional and Data Driven Electrochemical Modeling and Analysis

To understand the behavior of electrochemical systems, we need to reduce the dimensionality of the measured current-voltage-time (I-V-t) data by fitting models, thus enabling us to analyze and compare the governing physics. Traditionally, the process for this is an 'expert first' approach: defining the model and its explicit assumptions based on inductive reasoning or empirical observation, fitting small portions of the I-V-t data where assumptions are most valid or carefully designing experiments to enforce key assumptions, and then interpreting the model parameters. However, modern data-driven methods enable a new paradigm: a 'data first' approach, where the latent behaviors governing the system's measured response are identified directly using machine-learning models that optimize both model structure and parameters from the I-V-t data, guaranteeing that the learned model explains as much of the observed system response as possible. After model identification, the model can then be interrogated by an expert to connect observed behaviors with underlying physics. This talk will review several different types of electrochemical analysis (electrochemical impedance, differential voltage-capacity, electrochemical kinetics) and compare the traditional and data-driven methods for analyzing the data.

42 ENGINEERING↗

Advancing electrochemical impedance analysis through innovations in the distribution of relaxation times method

Electrochemical impedance spectroscopy (EIS) is a key tool across various scientific disciplines, including energy sciences, chemistry, and biology, enabling the analysis of electrochemical systems. However, conventional methods for interpreting EIS data are often complex and model dependent. The distribution of relaxation times (DRT) offers a non-parametric approach that simplifies the interpretation process by providing a timescale interpretation of EIS data. This article provides a comprehensive review of current methods for DRT inversion. Additionally, a survey of practitioners highlights key challenges in the field. Here, the findings underscore the need for standardized DRT analysis and benchmarks, as well as the development of automated analysis tools. These advancements would improve the usability and interpretability of EIS data. Ultimately, implementing these improvements could not only propel the field forward but also expand the application of DRT in scientific research by making it accessible to a broader range of researchers, including those without specialized expertise in programming or statistics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗