Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrochemical impedance spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Probing the chemistry of nickel/metal hydride battery cells using electrochemical impedance spectroscopy

Electrochemical Impedance Spectroscopy (EIS) is a valuable tool for investigating the chemical and physical processes occurring at electrode surfaces. It offers information about electron transfer at interfaces, kinetics of reactions, and diffusion characteristics of the bulk phase between the electrodes. For battery cells, this technique offers another advantage in that it can be done without taking the battery apart. This non-destructive analysis technique can thus be used to gain a better understanding of the processes occurring within a battery cell. This also raises the possibility of improvements in battery design and identification or prediction of battery characteristics useful in industry and aerospace applications. EIS as a technique is powerful and capable of yielding significant information about the cell, but it also requires that the many parameters under investigation can be resolved. This implies an understanding of the processes occurring in a battery cell. Many battery types were surveyed in this work, but the main emphasis was on nickel/metal hydride batteries.

Isaac, Bryan J.↗

Characterization of Molybdate Conversion Coatings for Aluminum Alloys by Electrochemical Impedance Spectroscopy

Electrochemical impedance spectroscopy (EIS) was used to investigate the corrosion inhibiting properties of newly developed proprietary molybdate conversion coatings on aluminum alloy 2024-T3 under immersion in aerated 5% (w/w) NaCl. Corrosion potential and EIS measurements were gathered for six formulations of the coating at several immersion times for two weeks. Nyquist as well as Bode plots of the data were obtained. The conversion-coated alloy panels showed an increase in the corrosion potential during the first 24 hours of immersion that later subsided and approached a steady value. Corrosion potential measurements indicated that formulations A, D, and F exhibit a protective effect on aluminum 2024-T3. The EIS spectra of the conversion-coated alloy were characterized by an impedance that is higher than the impedance of the bare alloy at all the immersion times. The low frequency impedance, Z(sub lf) (determined from the value at 0.05 Hz) for the conversion-coated alloy was higher at all the immersion times than that of the bare panel. This indicates improvement of corrosion resistance with addition of the molybdate conversion coating. Scanning electron microscopy (SEM) revealed the presence of cracks in the coating and the presence of cubic crystals believed to be calcium carbonate. Energy dispersive spectroscopy (EDS) of the test panels revealed the presence of high levels of aluminum, oxygen, and calcium but did not detect the presence of molybdenum on the test panels. X-ray photoelectron spectroscopy (XPS) indicated the presence of less than 0.01 atomic percent molybdenum on the surface of the coating.

Calle, Luz Marina↗

Detecting onset of lithium plating during fast charging of Li-ion batteries using operando electrochemical impedance spectroscopy

Electrochemical plating of Li metal on the graphite electrode is the key limitation behind slow charging times of Li-ion batteries (LIBs) in electric vehicles (EVs). Currently, electrochemical methods to detect the onset of Li plating while a battery is fast charging are sparse. In this study, we use operando electrochemical impedance spectroscopy to reliably detect the onset of Li plating on graphite electrodes in three-electrode LIBs. An increase in the graphite solid-electrolyte interface (SEI) resistance indicates that Li plating has occurred. By cross-validating with a highly sensitive ex situ chemical titration, we determine that this technique can detect very small amounts of plated Li (<0.6% of the graphite electrode's capacity). We also offer physical explanations for the observed impedance behavior. Finally, we show that this technique can be applied to standard two-electrode LIB systems, making the method an important step toward safely implementing fast charging protocols for LIBs in EVs.

25 ENERGY STORAGE↗

The deep-DRT: A deep neural network approach to deconvolve the distribution of relaxation times from multidimensional electrochemical impedance spectroscopy data

Electrochemical impedance spectroscopy (EIS) is an experimental technique ubiquitously used to study electrochemical systems. However, conventional EIS data interpretation through physical and equivalent circuit models is challenging because physical models are problem-specific, and equivalent circuits are often just lumped-element analogs lacking physical meaning. The distribution of relaxation times (DRT) has emerged as a complementary approach to resolve these issues. One drawback of conventional DRT deconvolution is that the EIS data is understood to be (only) a function of frequency (i.e. 1D data) and deconvolved accordingly. This work proposes a novel deconvolution method based on deep neural networks (DNNs), allowing the analysis of multidimensional EIS spectra to bridge data dependency on both frequencies and experimental conditions. Two particularly appealing traits of the deep-DRT method developed in this article are that neither regularization nor specific spacing on the state variables defining the experiment are required. Finally, leveraging DNN to examine complex EIS spectra and their dependence on experimental conditions, this work opens a new research direction in the area of EIS analysis and DRT deconvolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Broad Applicability of Electrochemical Impedance Spectroscopy to the Measurement of Oxygen Nonstoichiometry in Mixed Ion and Electron Conductors

Oxygen non-stoichiometry is a fundamental feature of mixed ion and electron conductors (MIECs). In this work a general electrochemical method for determining non-stoichiometry in thin film MIECs, via measurement of the chemical capacitance, is demonstrated using ceria and ceria-zirconia (Ce 0.8 Zr 0.2 O 2-δ ) as representative materials. A.C. impedance data are collected from both materials at high temperature (750-900 °C) under reducing conditions with oxygen partial pressure (pO 2 ) in the range 10-13 to 10-20 atm. Additional measurements of ceria-zirconia films are made under relatively oxidizing conditions with pO 2 in the range 0.2 to 10 -4 atm and temperatures of 800-900 °C. Under reducing conditions, the impedance spectra are described by a simple circuit in which a resistor is in series with a resistor and capacitor in parallel, and thickness dependent measurements are used to resolve the capacitance into interfacial and chemical terms. Under more oxidizing conditions, the impedance spectra (of Ce 0.8 Zr 0.2 O 2-δ ) reveal an additional diffusional feature, which enables determination of the ionic resistance of the film in addition to the capacitance, and hence the transport properties. A generalized mathematical formalism is presented for recovering the non-stoichiometry from the chemical capacitance, without recourse to defect chemical models. The ceria non-stoichiometry values are in good agreement with literature values determined by thermogravimetric measurements but display considerably less scatter and are collected on considerably shorter timescales. Here, the thermodynamic analysis of Ce 0.8 Zr 0.2 O 2-δ corroborates earlier findings that introduction of Zr into ceria enhances its reducibility.

08 HYDROGEN↗

Towards robust autonomous impedance spectroscopy analysis: A calibrated hierarchical Bayesian approach for electrochemical impedance spectroscopy (EIS) inversion

Distribution-based analyses, such as the distribution of relaxation times (DRT) and the distribution of diffusion times (DDT), present model-free alternatives to equivalent circuit modeling for analysis of electrochemical impedance spectroscopy (EIS) data. However, reconstructing such distributions from noisy impedance data is an ill-posed problem that must be solved with specialized inversion algorithms, requiring careful control and tuning. Furthermore, most inversion algorithms developed to date can only solve problems of limited complexity. Herein, we present a new hierarchical Bayesian method for EIS inversion, leveraging efficient algorithms for optimization and Hamiltonian Monte Carlo (HMC) sampling to solve models of arbitrary complexity. We overcome the challenge of ad-hoc parameter tuning by encoding intrinsic characteristics of the DRT and DDT into flexible prior distributions and “pre-calibrating” the model to simulated data. This approach is versatile, highly robust to noise, and provides quantitative estimates of both the error structure of the data and the uncertainty in the recovered distributions. The model is validated with simulated data to demonstrate accurate recovery of the DRT and the DDT. The method also shows promise for simultaneous recovery of multiple distributions, raising the intriguing possibility of semi-autonomous EIS analysis and ad-hoc model construction. Finally, the practical utility of the method is illustrated with experimental data. Throughout, we draw comparisons to several recently published EIS inversion methodologies.

36 MATERIALS SCIENCE↗

Electrochemical Impedance Spectroscopy of Conductive Polymer Coatings

Electrochemical impedance spectroscopy (EIS) was used to investigate the corrosion protection performance of twenty nine proprietary conductive polymer coatings for cold rolled steel under immersion in 3.55 percent NaCl. Corrosion potential as well as Bode plots of the data were obtained for each coating after one hour immersion, All coatings, with the exception of one, have a corrosion potential that is higher in the positive direction than the corrosion potential of bare steel under the same conditions. Group A consisted of twenty one coatings with Bode plots indicative of the capacitive behavior characteristic of barrier coatings. An equivalent circuit consisting of a capacitor in series with a resistor simulated the experimental EIS data for these coatings very well. Group B consisted of eight coatings that exhibited EIS spectra showing an inflection point which indicates that two time constants are present. This may be caused by an electrochemical process taking place which could be indicitive of coating failing. These coatings have a lower impedance that those in Group A.

Calle, Luz Marina↗

Electrochemical Impedance Spectroscopy Of Metal Alloys

Report describes use of electrochemical impedance spectroscopy (EIS) to investigate resistances of 19 alloys to corrosion under conditions similar to those of corrosive, chloride-laden seaside environment of Space Transportation System launch site. Alloys investigated: Hastelloy C-4, C-22, C-276, and B-2; Inconel(R) 600, 625, and 825; Inco(R) G-3; Monel 400; Zirconium 702; Stainless Steel 304L, 304LN, 316L, 317L, and 904L; 20Cb-3; 7Mo+N; ES2205; and Ferralium 255. Results suggest electrochemical impedance spectroscopy used to predict corrosion performances of metal alloys.

Macdowell, L. G.↗

A mathematical approach to survey electrochemical impedance spectroscopy for aging in lithium-ion batteries

Electrochemical impedance spectroscopy (EIS) is a valuable technique to detect the health status and aging phenomena in lithium-ion batteries (LiB). Equivalent circuit modeling (ECM) is conventionally used when interpreting EIS data and gaining physical insights into the aging mechanisms. However, performing ECM is resource intensive and expert-level of knowledge is usually required to select suitable models and fitting parameters. This article presents a quick and user-friendly data analysis algorithm as an alternative to ECM by mathematically fitting geometric features in Nyquist plots and obtaining the growth trends of the features. The evolving trends in the Nyquist plots, such as chord lengths of the arcs and interception points, are consistent with the growth of resistance components obtained using ECM with R 2 values from 0.67 to 0.99, and therefore can be used as indicators of battery aging. Our results show that the quick-fitting approach is suitable for analyzing a series of EIS data acquired during battery cycling and identifying the underlying aging mechanisms.

Chen, Bor-Rong↗

Evaluation of inorganic zinc-rich primers using Electrochemical Impedance Spectroscopy (EIS)

This investigation explores the use of Electrochemical Impedance Spectroscopy (EIS) in combination with beach exposure as a short term method for analyzing the performance of twenty-one zinc-rich primers. The twenty-one zinc-rich primers were: Carboline CZ-11, Ameron Devoe-Marine Catha-Coat 304, Briner V-65, Ameron D-21-9, Sherwin Williams Zinc Clad II, Carboline CZ-D7, Ameron D-4, Dupont Ganicin 347WB, Porter TQ-4374H, Inorganic Coatings IC-531, Subox Galvanox IV, Southern Coatings Chemtec 600, Glidden Glidzinc 5530, Byco SP-101, Tnemec 90E-75, Devoe Catha-Coat 302H, Glidden Glidzinc 5536, Koppers 701, Ameron D-21-5, Coronado 935-152, and Subox Galvanoz V. Data were also collected on galvanized steel for comparison purposes. A library of Bode magnitude plots was generated for each coating including curves for the initial time and after each week of atmospheric exposure as Beach Corrosion Test Site near the Space Shuttle launch pad at the Kennedy Space Center for up to three weeks. An examination of the variation of the Bode magnitude plots with atmospheric exposure revealed no clearly identifiable trend at this point that could distinguish between the good and the poor coatings. The test will be continued by including EIS measurements after six months and one year of atmospheric exposure.

Calle, Luz M.↗

Evaluation of inorganic zinc-rich primers using Electrochemical Impedance Spectroscopy (EIS) in combination with atmospheric exposure

This investigation explored the use of Electrochemical Impedance Spectroscopy (EIS) in combination with atmospheric exposure as a short term method for analyzing the performance of twenty-one commercially available zinc-rich primers. The twenty-one zinc-rich primers were: Carboline CZ-11, Ameron Devoe-Marine Catha-Coat 304, Briner V-65, Ameron D-21-9, Sherwin Williams Zinc Clad II, Carboline CZ-D7, Ameron D-4, Dupont Ganicin 347WB, Porter TQ-4374H, Inorganic Coatings IC-531, Subox Galvanox IV, Southern Coatings Chemtec 600, GLidden Glidzinc 5530, Byco SP-101, Tnemec 90E-75, Devoe Catha-Coat 302H, Glidden Glidzinc 5536, Koppers 701, Ameron D-21-5, Coronado 935-152, and Subox Galvanox V. Data were also collected on galvanized steel for comparison purposes. A library of Bode magnitude plots was generated for each coating including curves for the initial time and after each week of atmospheric exposure at the Beach Corrosion Test site near the Space Shuttle launch pad at the Kennedy Space Center for up to four weeks. Subsequent measurements were collected after 8 weeks and after one year of atmospheric exposure. Analysis of the impedance data was performed with the purpose of identifying parameters that could be used to predict the long-term performance of zinc-rich primers. It has been shown that there is a correlation between the long-term performance of zinc-rich primers and several parameters obtained from EIS measurements in combination with atmospheric exposure. The equivalent circuit R2(R2C(R3W)) provided a satisfactory fit for the EIS data. The corrosion potential and the R2 resistance are parameters indicative of the galvanic mechanism of protection. The capacitance of the coating is related to the barrier mechanism of protection.

Calle, Luz M.↗

Mitigating Electrochemical Impedance Spectroscopy Artifacts in PEMWE Reference Electrode Measurements

This study investigates strategies to improve the quality of electrochemical impedance spectroscopy (EIS) measurements using reference electrodes (RE) in proton exchange membrane water electrolyzers (PEMWE). We demonstrate that adding a low impedance wire in parallel to the RE significantly enhances signal accuracy, especially at high frequencies. Additionally, we identify electrical pad heaters as a source of measurement noise. EIS measurements fulfilling Kramers–Kronig validity criteria were only achieved in their absence. These insights advance the diagnostic capabilities of REs in water electrolyzers and support more reliable, spatially resolved analysis of electrochemical losses within the cell.

08 HYDROGEN↗

The application of electrochemical impedance spectroscopy for characterizing the degradation of Ni(OH)2/NiOOH electrodes

The use of wide-band electrochemical impedance spectroscopy is described for characterizing the degradation of porous Ni(OH)2/NiOOH electrodes in concentrated KOH electrolyte solutions. The impedance spectra are interpreted in terms of a finite electrical transmission line and the changes in the components of the electrical analog are followed as a function of cycle number. The degradation of the capacity of rolled and bonded Ni(OH)2/NiOOH electrodes is caused by rupture of ohmic contacts within the active mass and by restructuring which results in a decrease in the number of active pores.

Macdonald, Digby D.↗

Corrosion Behavior of Stainless Steels in Neutral and Acidified Sodium Chloride Solutions by Electrochemical Impedance Spectroscopy

The objective of this work was to evaluate the corrosion performance of three alloys by Electrochemical Impedance Spectroscopy (EIS) and to compare the results with those obtained during a two-year atmospheric exposure study.' Three alloys: AL6XN (UNS N08367), 254SM0 (UNS S32154), and 304L (UNS S30403) were included in the study. 304L was included as a control. The alloys were tested in three electrolyte solutions which consisted of neutral 3.55% NaC1, 3.55% NaC1 in 0.lN HC1, and 3.55% NaC1 in 1.ON HC1. These conditions were expected to be less severe, similar, and more severe respectively than the conditions at NASA's Kennedy Space Center launch pads.

Calle, L. M.↗

Probing transport energies and defect states in organic semiconductors using energy resolved electrochemical impedance spectroscopy

Abstract Determining the relative energies of transport states in organic semiconductors is critical to understanding the properties of electronic devices and in designing device stacks. Futhermore, defect states are also highly important and can greatly impact material properties and device performance. Recently, energy‐resolved electrochemical impedance spectroscopy (ER‐EIS) is developed to probe both the ionization energy (IE) and electron affinity (EA) as well as sub‐bandgap defect states in organic semiconductors. Herein, ER‐EIS is compared to cyclic voltammetry (CV) and photoemission spectroscopies for extracting IE and EA values, and to photothermal deflection spectroscopy (PDS) for probing defect states in both polymer and molecular organic semiconductors. The results show that ER‐EIS determined IE and EA are in better agreement with photoemission spectroscopy measurements as compared to CV for both polymer and molecular materials. Furthermore, the defect states detected by ER‐EIS agree with sub‐bandgap features detected by PDS. Surprisingly, ER‐EIS measurements of regiorandom and regioregular poly(3‐hexylthiophene) (P3HT) show clear defect bands that occur at significantly different energies. In regioregular P3HT the defect band is near the edge of the occupied states while it is near the edge of the unoccupied states in regiorandom P3HT.

14 SOLAR ENERGY↗

Electrochemical Impedance Spectroscopy and Cyclic Voltammetry Methods for Monitoring SmCl 3 Concentration in Molten Eutectic LiCl-KCl

Molten salt solutions consisting of eutectic LiCl-KCl and concentrations of samarium chloride (0.5 to 3.0 wt%) at 500 C were analyzed using both cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The CV technique gave the average diffusion coefficient for Sm 3+ over the concentration range. Equipped with Sm 3+ diffusion coefficient, the Randles-Sevcik equation predicted Sm 3+ concentration values that agree with the given experimental values. From CV measurements; the anodic, cathodic, and half-peak potentials were identified and subsequently used as a parameter to acquire EIS spectra. A six-element Voigt model was used to model the EIS data in terms of resistance-time constant pairs. The lowest resistances were observed at the half-peak potential with the associated resistance-time constant pairs characterizing the reversible reaction between Sm 3+ and Sm 2+ . By extrapolation, the Voigt model estimated the polarization resistance and established a polarization resistance-concentration relationship.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

HunStat2 – a simple and low-cost potentiostat with electrochemical impedance spectroscopy capability

We have developed a low-cost (30 USD), simple do-it-yourself (DIY) potentiostat with cyclic voltammetry (CV), open circuit potential (OCP) and electrochemical impedance spectroscopy (EIS) capability. The HunStat2 potentiostat is based on Analog Devices' AD5941 Analog Front End chip, which significantly simplifies the construction of potentiostats for both direct and alternating current (DC and AC, respectively) techniques. Interested readers are provided with circuit diagrams and a bill of materials to build the potentiostat on their own. In addition, control software is also provided free of charge. The software enables acquisition and visualization of data. In summary, HunStat2 introduces a simple and low-cost DIY potentiostat recommended for both analytical and educational purposes.

Vamos, Istvan [Lajos Petrik Vocational Chemistry S↗