Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrochemical impedance spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Detecting onset of lithium plating during fast charging of Li-ion batteries using operando electrochemical impedance spectroscopy

Electrochemical plating of Li metal on the graphite electrode is the key limitation behind slow charging times of Li-ion batteries (LIBs) in electric vehicles (EVs). Currently, electrochemical methods to detect the onset of Li plating while a battery is fast charging are sparse. In this study, we use operando electrochemical impedance spectroscopy to reliably detect the onset of Li plating on graphite electrodes in three-electrode LIBs. An increase in the graphite solid-electrolyte interface (SEI) resistance indicates that Li plating has occurred. By cross-validating with a highly sensitive ex situ chemical titration, we determine that this technique can detect very small amounts of plated Li (<0.6% of the graphite electrode's capacity). We also offer physical explanations for the observed impedance behavior. Finally, we show that this technique can be applied to standard two-electrode LIB systems, making the method an important step toward safely implementing fast charging protocols for LIBs in EVs.

25 ENERGY STORAGE↗

The deep-DRT: A deep neural network approach to deconvolve the distribution of relaxation times from multidimensional electrochemical impedance spectroscopy data

Electrochemical impedance spectroscopy (EIS) is an experimental technique ubiquitously used to study electrochemical systems. However, conventional EIS data interpretation through physical and equivalent circuit models is challenging because physical models are problem-specific, and equivalent circuits are often just lumped-element analogs lacking physical meaning. The distribution of relaxation times (DRT) has emerged as a complementary approach to resolve these issues. One drawback of conventional DRT deconvolution is that the EIS data is understood to be (only) a function of frequency (i.e. 1D data) and deconvolved accordingly. This work proposes a novel deconvolution method based on deep neural networks (DNNs), allowing the analysis of multidimensional EIS spectra to bridge data dependency on both frequencies and experimental conditions. Two particularly appealing traits of the deep-DRT method developed in this article are that neither regularization nor specific spacing on the state variables defining the experiment are required. Finally, leveraging DNN to examine complex EIS spectra and their dependence on experimental conditions, this work opens a new research direction in the area of EIS analysis and DRT deconvolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Broad Applicability of Electrochemical Impedance Spectroscopy to the Measurement of Oxygen Nonstoichiometry in Mixed Ion and Electron Conductors

Oxygen non-stoichiometry is a fundamental feature of mixed ion and electron conductors (MIECs). In this work a general electrochemical method for determining non-stoichiometry in thin film MIECs, via measurement of the chemical capacitance, is demonstrated using ceria and ceria-zirconia (Ce 0.8 Zr 0.2 O 2-δ ) as representative materials. A.C. impedance data are collected from both materials at high temperature (750-900 °C) under reducing conditions with oxygen partial pressure (pO 2 ) in the range 10-13 to 10-20 atm. Additional measurements of ceria-zirconia films are made under relatively oxidizing conditions with pO 2 in the range 0.2 to 10 -4 atm and temperatures of 800-900 °C. Under reducing conditions, the impedance spectra are described by a simple circuit in which a resistor is in series with a resistor and capacitor in parallel, and thickness dependent measurements are used to resolve the capacitance into interfacial and chemical terms. Under more oxidizing conditions, the impedance spectra (of Ce 0.8 Zr 0.2 O 2-δ ) reveal an additional diffusional feature, which enables determination of the ionic resistance of the film in addition to the capacitance, and hence the transport properties. A generalized mathematical formalism is presented for recovering the non-stoichiometry from the chemical capacitance, without recourse to defect chemical models. The ceria non-stoichiometry values are in good agreement with literature values determined by thermogravimetric measurements but display considerably less scatter and are collected on considerably shorter timescales. Here, the thermodynamic analysis of Ce 0.8 Zr 0.2 O 2-δ corroborates earlier findings that introduction of Zr into ceria enhances its reducibility.

08 HYDROGEN↗

Towards robust autonomous impedance spectroscopy analysis: A calibrated hierarchical Bayesian approach for electrochemical impedance spectroscopy (EIS) inversion

Distribution-based analyses, such as the distribution of relaxation times (DRT) and the distribution of diffusion times (DDT), present model-free alternatives to equivalent circuit modeling for analysis of electrochemical impedance spectroscopy (EIS) data. However, reconstructing such distributions from noisy impedance data is an ill-posed problem that must be solved with specialized inversion algorithms, requiring careful control and tuning. Furthermore, most inversion algorithms developed to date can only solve problems of limited complexity. Herein, we present a new hierarchical Bayesian method for EIS inversion, leveraging efficient algorithms for optimization and Hamiltonian Monte Carlo (HMC) sampling to solve models of arbitrary complexity. We overcome the challenge of ad-hoc parameter tuning by encoding intrinsic characteristics of the DRT and DDT into flexible prior distributions and “pre-calibrating” the model to simulated data. This approach is versatile, highly robust to noise, and provides quantitative estimates of both the error structure of the data and the uncertainty in the recovered distributions. The model is validated with simulated data to demonstrate accurate recovery of the DRT and the DDT. The method also shows promise for simultaneous recovery of multiple distributions, raising the intriguing possibility of semi-autonomous EIS analysis and ad-hoc model construction. Finally, the practical utility of the method is illustrated with experimental data. Throughout, we draw comparisons to several recently published EIS inversion methodologies.

36 MATERIALS SCIENCE↗

A mathematical approach to survey electrochemical impedance spectroscopy for aging in lithium-ion batteries

Electrochemical impedance spectroscopy (EIS) is a valuable technique to detect the health status and aging phenomena in lithium-ion batteries (LiB). Equivalent circuit modeling (ECM) is conventionally used when interpreting EIS data and gaining physical insights into the aging mechanisms. However, performing ECM is resource intensive and expert-level of knowledge is usually required to select suitable models and fitting parameters. This article presents a quick and user-friendly data analysis algorithm as an alternative to ECM by mathematically fitting geometric features in Nyquist plots and obtaining the growth trends of the features. The evolving trends in the Nyquist plots, such as chord lengths of the arcs and interception points, are consistent with the growth of resistance components obtained using ECM with R 2 values from 0.67 to 0.99, and therefore can be used as indicators of battery aging. Our results show that the quick-fitting approach is suitable for analyzing a series of EIS data acquired during battery cycling and identifying the underlying aging mechanisms.

Chen, Bor-Rong↗

Mitigating Electrochemical Impedance Spectroscopy Artifacts in PEMWE Reference Electrode Measurements

This study investigates strategies to improve the quality of electrochemical impedance spectroscopy (EIS) measurements using reference electrodes (RE) in proton exchange membrane water electrolyzers (PEMWE). We demonstrate that adding a low impedance wire in parallel to the RE significantly enhances signal accuracy, especially at high frequencies. Additionally, we identify electrical pad heaters as a source of measurement noise. EIS measurements fulfilling Kramers–Kronig validity criteria were only achieved in their absence. These insights advance the diagnostic capabilities of REs in water electrolyzers and support more reliable, spatially resolved analysis of electrochemical losses within the cell.

08 HYDROGEN↗

Probing transport energies and defect states in organic semiconductors using energy resolved electrochemical impedance spectroscopy

Abstract Determining the relative energies of transport states in organic semiconductors is critical to understanding the properties of electronic devices and in designing device stacks. Futhermore, defect states are also highly important and can greatly impact material properties and device performance. Recently, energy‐resolved electrochemical impedance spectroscopy (ER‐EIS) is developed to probe both the ionization energy (IE) and electron affinity (EA) as well as sub‐bandgap defect states in organic semiconductors. Herein, ER‐EIS is compared to cyclic voltammetry (CV) and photoemission spectroscopies for extracting IE and EA values, and to photothermal deflection spectroscopy (PDS) for probing defect states in both polymer and molecular organic semiconductors. The results show that ER‐EIS determined IE and EA are in better agreement with photoemission spectroscopy measurements as compared to CV for both polymer and molecular materials. Furthermore, the defect states detected by ER‐EIS agree with sub‐bandgap features detected by PDS. Surprisingly, ER‐EIS measurements of regiorandom and regioregular poly(3‐hexylthiophene) (P3HT) show clear defect bands that occur at significantly different energies. In regioregular P3HT the defect band is near the edge of the occupied states while it is near the edge of the unoccupied states in regiorandom P3HT.

14 SOLAR ENERGY↗

Electrochemical Impedance Spectroscopy and Cyclic Voltammetry Methods for Monitoring SmCl 3 Concentration in Molten Eutectic LiCl-KCl

Molten salt solutions consisting of eutectic LiCl-KCl and concentrations of samarium chloride (0.5 to 3.0 wt%) at 500 C were analyzed using both cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The CV technique gave the average diffusion coefficient for Sm 3+ over the concentration range. Equipped with Sm 3+ diffusion coefficient, the Randles-Sevcik equation predicted Sm 3+ concentration values that agree with the given experimental values. From CV measurements; the anodic, cathodic, and half-peak potentials were identified and subsequently used as a parameter to acquire EIS spectra. A six-element Voigt model was used to model the EIS data in terms of resistance-time constant pairs. The lowest resistances were observed at the half-peak potential with the associated resistance-time constant pairs characterizing the reversible reaction between Sm 3+ and Sm 2+ . By extrapolation, the Voigt model estimated the polarization resistance and established a polarization resistance-concentration relationship.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

HunStat2 – a simple and low-cost potentiostat with electrochemical impedance spectroscopy capability

We have developed a low-cost (30 USD), simple do-it-yourself (DIY) potentiostat with cyclic voltammetry (CV), open circuit potential (OCP) and electrochemical impedance spectroscopy (EIS) capability. The HunStat2 potentiostat is based on Analog Devices' AD5941 Analog Front End chip, which significantly simplifies the construction of potentiostats for both direct and alternating current (DC and AC, respectively) techniques. Interested readers are provided with circuit diagrams and a bill of materials to build the potentiostat on their own. In addition, control software is also provided free of charge. The software enables acquisition and visualization of data. In summary, HunStat2 introduces a simple and low-cost DIY potentiostat recommended for both analytical and educational purposes.

Vamos, Istvan [Lajos Petrik Vocational Chemistry S↗

Interpreting Ionic Conductivity for Polymer Electrolyte Fuel Cell Catalyst Layers with Electrochemical Impedance Spectroscopy and Transmission Line Modeling

A cathode catalyst layer containing optimally distributed ionomer is critical to reduce the platinum loading and increase its utilization in polymer electrolyte fuel cells. Here, electrochemical impedance spectroscopy (EIS) was used to measure effective ionic conductivity of pseudo catalyst layers (PCLs) at a relative humidity (RH) range of 50%-120%. These results are compared to previous work using the hydrogen pump (HP) method. EIS effective ionic conductivity results reported here are higher than those from the HP because in the HP set-up ionic pathways must be effectively connected through the PCL to be counted, whereas in the EIS measurement, ionomer segments that are in contact with the membrane but are not effectively connected all the way through the PCL can be detected. Double layer capacitances and effective ionic conductivities of Pt/C catalyst layers with various supports and ionomer to carbon (I/C) ratios were studied. High surface area carbon support resulted in a lower effective ionic conductivity compared to the graphitized carbon support due to worse ionomer dispersion. Effective ionic conductivities of Pt/C layers were compared to that of PCLs. On average, effective ionic conductivities of Pt/C layers were higher than PCLs because of possible carbon agglomeratio n within the PCLs.

25 ENERGY STORAGE↗

Instrument for spatially resolved, temperature-dependent electrochemical impedance spectroscopy of thin films under locally controlled atmosphere

We demonstrate an instrument for spatially resolved measurements (mapping) of electrochemical impedance under various temperatures and gas environments. Automated measurements are controlled by a custom LabVIEW program, which manages probe motion, sample motion, temperature ramps, and potentiostat functions. Sample and probe positioning is provided by stepper motors. Dry or hydrated atmospheres (air or nitrogen) are available. The configurable heater reaches temperatures up to 500 °C, although the temperature at the sample surface is moderated by the gas flow rate. The local gas environment is controlled by directing flow toward the sample via a glass enclosure that surrounds the gold wire probe. Software and hardware selection and design are discussed. Reproducibility and accuracy are quantified on a Ba(Zr,Y)O 3-δ proton-conducting electrolyte thin film synthesized by pulsed laser deposition. The mapping feature of the instrument is demonstrated on a compositionally graded array of electrocatalytically active Ba(Co,Fe,Zr,Y)O 3-δ thin film microelectrodes. The resulting data indicate that this method proficiently maps property trends in these materials, thus demonstrating the reliability and usefulness of this method for investigating electrochemically active thin films.

47 OTHER INSTRUMENTATION↗

Characterizing pulse reverse-pulse uranium recovery in molten LiCl-KCl with intermittent electrochemical impedance spectroscopy

In this work, EIS was applied to characterize the temporal recovery of uranium from UCl 4 onto a tungsten electrode in molten LiCl-KCl salt between sets of pulse reverse-pulse (PRP) deposition steps. Impedance measurements were fitted to an equivalent circuit (EC) model of the electrode interface using Simplex optimization to calculate the double layer capacitance, charge transfer resistance, Warburg impedance, and CPE-restricted diffusion. Diffusion of uranium towards the electrode surface dominated the surface interactions for the first 80 cycles, followed by a transition to kinetic control for the remaining 520 cycles. A decrease in the Warburg impedance showed depletion of uranium from the bulk melt, which was confirmed to be a 52.5% reduction through ICP-OES. Reduction in the phasance from CPE-restricted diffusion suggested the formation of pores in the uranium deposits, which was confirmed through SEM characterization.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Electron and proton conductivity of Fe-N-C cathodes for PEM fuel cells: A model-based electrochemical impedance spectroscopy measurement

Impedance spectra of a PEM fuel cell with three Fe-N-C cathodes have been measured under the H 2 /N 2 testing regime. The spectra have been fitted using a recently developed physics-based impedance model, which takes into account finite proton ($σ_p$) and electron ($σ_e$) conductivity of the oxygen-free cathode catalyst layer. Fitting allowed to extract numerical data for $σ_p$, $σ_e$, the double layer capacitance, and the inductance of cables used for measuring impedance spectra. The values of σp and σe are close to what previously found for standard Pt/C electrodes, which is found for the first time using PGM-free catalysts. The method enables simultaneous measurement of reference proton and electron conductivity of PEMFC cathode.

25 ENERGY STORAGE↗

Improving Electronic Conductivity of Layered Oxides through the Formation of Two-Dimensional Heterointerface for Intercalation Batteries

Synthetic strategies for the improvement in electronic conductivities and electrochemical stabilities of transition metal oxide cathodes, which are limiting factors in the performance of commercial intercalation batteries, are required for next-generation, high-performance battery systems. Furthermore, the chemical preintercalation approach, consisting of a combined sequence of a sol–gel process, extended aging, and a hydrothermal treatment, is a versatile, wet synthesis technique that allows for the incorporation of a polar species between the layers of transition metal oxides. Here, formation of a layered 2D δ-C x V 2 O 5 · n H 2 O heterostructure occurs via chemical preintercalation of dopamine molecules between bilayers of vanadium oxide followed by the hydrothermal treatment of the precipitate, leading to carbonization of the organic molecules. The presence of carbon layers within the structure has been confirmed via a combined analysis of scanning electron microscopy, X-ray diffraction, thermogravimetric analysis, Raman spectroscopy, X-ray photoelectron spectroscopy, electrochemical impedance spectroscopy, four-probe conductivity measurements, and scanning transmission electron microscopy characterization. 2D δ-C x V 2 O 5 · n H 2 O heterostructure electrodes demonstrated significantly improved electrochemical performance, particularly at higher current densities, in Li-ion cells. The heterostructure electrodes exhibited 75% of the capacity retention when the current was changed from 20 mA g –1 (206 mAh g –1 ) to 300 mA g –1 (155 mAh g –1 ), while the reference δ-V 2 O 5 · n H 2 O electrodes exhibited only 10% capacity retention in the same experiment. Remarkably, 2D δ-C x V 2 O 5 · n H 2 O heterostructure electrodes demonstrated significantly improved capacity retention (94% after 30 cycles) for bilayered vanadium oxide electrodes in Li-ion cells during galvanostatic cycling at 20 mA g –1 . The improved electrochemical performance, in both extended cycling and rate capability studies, of the 2D δ-C x V 2 O 5 · n H 2 O heterostructure electrodes in the Li-ion system is ascribed to the intermittent formation of carbon layers within the bilayered structure, which leads to increased electronic conductivity and improved structural stability of the heterostructure compared to the reference δ-V 2 O 5 · n H 2 O electrodes.

25 ENERGY STORAGE↗

Evaluation of electrochemical performance and redox activity of Fe in Ti doped layered P2-Na0.67Mn0.5Fe0.5O2 cathode for sodium ion batteries

Here, we report a wet synthesis-based titanium doping strategy to improve the structural stability and electrochemical performances, such as cycling stability and rate capability, of P2-type Na 0.67 Fe 0.5 Mn 0.5 O 2 layered oxide cathodes. Through Ti 4+ doping aimed at replacing some of the Mn and Fe atoms in the crystal structure, effective mitigation of the Jahn Teller distortion caused by active Mn 3+ before charging and Fe 4+ after charging was achieved. X-ray diffraction (XRD), Raman spectroscopy, Electrochemical Impedance Spectroscopy (EIS) and Mössbauer spectroscopy were used to investigate the effects of the Ti 4+ dopant before and after cycling. It was observed that Ti 4+ doping increased the Na layer thickness, minimized the lattice volume strain, showed better structural stability, minimally decreased Fe migration to the Na layer, and lowered charge transfer resistance in these P2-type cathodes. Overall, our reported synthesis methodology and electrochemical characterizations highlight the feasibility of Ti doping in sodium layered oxide P2-type cathodes.

25 ENERGY STORAGE↗

Rapid mapping of electrochemical processes in energy-conversion devices

Electrochemical impedance spectroscopy (EIS) is ubiquitously applied to identify physicochemical processes governing the performance of energy-conversion devices. However, deconvolution and interpretation of impedance phenomena are limited by measurement throughput and a dearth of scalable analysis methods. Here, we demonstrate an approach to quickly collect and coherently analyze large volumes of electrochemical data. In this study, we accelerate impedance characterization by combining rapid measurements in time and frequency domains, which are interpretably transformed using the distribution of relaxation times (DRT) and a new distribution of phasances (DOP) model. This method provides excellent agreement with EIS and decreases measurement time by an order of magnitude. High-throughput spectra are then distilled into detailed electrochemical maps. This approach is applied to a Li-ion battery and a protonic ceramic electrochemical cell as practical case studies, demonstrating how mapping can richly characterize physicochemical relationships that are difficult to decipher with conventional measurement and analysis methods.

25 ENERGY STORAGE↗

Watching Polarons Move in the Energy and Frequency Domains Using Color Impedance Spectroscopy

The hybrid electronic–ionic transport property of π-conjugated polymers enables new (opto)electrochemical device constructs for energy conversion and storage and biosensing applications. One major challenge is separating the energy and frequency dependence of Faradaic events–those involving charge transfer and the redox processes of the conjugated backbone–from the non-Faradaic components, such as ionic motion. Herein, we combine optical spectroscopy with electrochemical impedance spectroscopy (EIS) to resolve the frequency response of ionic–electronic coupling as a function of electrochemical doping potential. First, using EIS, we identify two different frequency regimes resulting in potential-dependent capacitive elements on the order of ~10 μF/cm 2 in a high-frequency regime and ~50–150 μF/cm 2 in a low-frequency regime. Given the larger magnitude and greater potential dependence, we posit that polaronic motion is more likely to occur at low frequencies (<1 kHz) and overlaps with ionic motion. The use of color impedance spectroscopy (CIS) enables observation of polaronic motion with frequency modulation. We observe that higher doping potentials show a greater motion of polarons above the DC-bias baseline concentration for onset in electrochemical doping, but all potentials considered demonstrate a critical frequency at which the polaronic motion is “frozen” (~40 Hz). Furthermore, this critical information obtained from CIS in highly dielectric environments offers a unique figure of merit for future studies on electronic–ionic coupling by which to compare across polymer/electrolyte interfaces, including the role of a charge-supporting electrolyte, a solvent, and alternative Faradaic processes (e.g., electrocatalysis).

36 MATERIALS SCIENCE↗