Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrochemistry & Conductivity Analyzer (MECA)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Atmospheric Condensation in the Mars Phoenix TECP and MET Data

A new calibration function for the humidity sensor in the Thermal and Electrical Conductivity Probe (TECP), a component of the Microscopy, Electrochemistry, and Conductivity Analyzer (MECA) on the Phoenix Mars mission has been developed. The data is now cast in terms of Frost Point (T(sub f)) and some flight data, taken when the atmosphere is independently known to be saturated, is included in the calibration data set. Combined with data from the Meteorology Mast air temperature sensors, a very sensitive detection of atmospheric saturation becomes possible (Figure 1).

Microscopy↗

The Thermal Electrical Conductivity Probe (TECP) for Phoenix

The Thermal and Electrical Conductivity Probe (TECP) is a component of the Microscopy, Electrochemistry, and Conductivity Analyzer (MECA) payload on the Phoenix Lander. TECP will measure the temperature, thermal conductivity and volumetric heat capacity of the regolith. It will also detect and quantify the population of mobile H2O molecules in the regolith, if any, throughout the polar summer, by measuring the electrical conductivity of the regolith, as well as the dielectric permittivity. In the vapor phase, TECP is capable of measuring the atmospheric H2O vapor abundance, as well as augment the wind velocity measurements from the meteorology instrumentation. TECP is mounted near the end of the 2.3 m Robotic Arm, and can be placed either in the regolith material or held aloft in the atmosphere. This paper describes the development and calibration of the TECP. In addition, substantial characterization of the instrument has been conducted to identify behavioral characteristics that might affect landed surface operations. The greatest potential issue identified in characterization tests is the extraordinary sensitivity of the TECP to placement. Small gaps alter the contact between the TECP and regolith, complicating data interpretation. Testing with the Phoenix Robotic Arm identified mitigation techniques that will be implemented during flight. A flight model of the instrument was also field tested in the Antarctic Dry Valleys during the 2007-2008 International Polar year. 2

Zent, Aaron P.↗

Phoenix Telemetry Processor

Phxtelemproc is a C/C++ based telemetry processing program that processes SFDU telemetry packets from the Telemetry Data System (TDS). It generates Experiment Data Records (EDRs) for several instruments including surface stereo imager (SSI); robotic arm camera (RAC); robotic arm (RA); microscopy, electrochemistry, and conductivity analyzer (MECA); and the optical microscope (OM). It processes both uncompressed and compressed telemetry, and incorporates unique subroutines for the following compression algorithms: JPEG Arithmetic, JPEG Huffman, Rice, LUT3, RA, and SX4. This program was in the critical path for the daily command cycle of the Phoenix mission. The products generated by this program were part of the RA commanding process, as well as the SSI, RAC, OM, and MECA image and science analysis process. Its output products were used to advance science of the near polar regions of Mars, and were used to prove that water is found in abundance there. Phxtelemproc is part of the MIPL (Multi-mission Image Processing Laboratory) system. This software produced Level 1 products used to analyze images returned by in situ spacecraft. It ultimately assisted in operations, planning, commanding, science, and outreach.

Stanboli, Alice↗

Oxychlorine Species on Mars: The Gale Crater Story

Comparing data from the Alpha- Particle X-Ray Spectrometer (APXS) and the Sample Analysis at Mars (SAM) instruments on MSL reveals a strong linear correlation between chlorine and oxygen, further demonstrating the presence of oxychlorine species in Gale Crater and, very likely, globally on Mars. Perchlorate was first discovered on Mars by the Microscopy, Electrochemistry, and Conductivity Analyzer (MECA) instrument on the Phoenix lander in 2008. Current hypotheses suggest that the formation of oxychlorine species such as perchlorate or chlorate is a global process and that these species should be globally distributed on Mars [e.g. 2-4]. To date, the SAM and Chemistry and Mineralogy (CheMin) instruments on MSL have analyzed one scooped sample of aeolian material (Rocknest [RN]), and four drilled samples (John Klein [JK], Cumberland [CB], Windjana [WJ], and Confidence Hills [CH]). The APXS instrument has also investigated the same or very similar samples. Although not definitively identified, oxychlorine species have been proposed to explain releases of O2, HCl, and chlorinated hydrocarbon species detected by evolved gas analysis (EGA) with the SAM instrument. We report a strong linear correlation between wt. % Cl detected by APXS and moles O2 detected by SAM during pyrolysis, indicating the presence of oxychlorine species in Gale Crater.

Archer, P. D., Jr.↗

The Phoenix Mars Lander Robotic Arm

The Phoenix Mars Lander Robotic Arm (RA) has operated for over 150 sols since the Lander touched down on the north polar region of Mars on May 25, 2008. During its mission it has dug numerous trenches in the Martian regolith, acquired samples of Martian dry and icy soil, and delivered them to the Thermal Evolved Gas Analyzer (TEGA) and the Microscopy, Electrochemistry, and Conductivity Analyzer (MECA). The RA inserted the Thermal and Electrical Conductivity Probe (TECP) into the Martian regolith and positioned it at various heights above the surface for relative humidity measurements. The RA was used to point the Robotic Arm Camera to take images of the surface, trenches, samples within the scoop, and other objects of scientific interest within its workspace. Data from the RA sensors during trenching, scraping, and trench cave-in experiments have been used to infer mechanical properties of the Martian soil. This paper describes the design and operations of the RA as a critical component of the Phoenix Mars Lander necessary to achieve the scientific goals of the mission.

Bonitz, Robert↗

LIRA: Probing the Lunar Surface for Resources.

The thermal, compositional and electrical properties of the lunar regolith, such as the triboelectric properties of lunar dust, the volatile content and the thermophysical properties of the polar regolith are essential to understand from a scientific perspective as well as for resource extraction and hazard mitigation. Understanding these properties specifically requires in situ measurement, as these properties are inherent in the ambient environment. With the Lunar In situ Regolith Analyzer (LIRA) we will combine mature surface sensor technologies from previous spacecraft missions (TECP) with new sensors (ClO4- ) and battery capability to achieve a compact in situ analysis package. The surface instrument suite is adapted for lunar conditions from a sensor developed as part of the Microscopy, Electrochemistry, and Conductivity Analyzer (MECA) instrument on the 2007 Mars Phoenix mission, as well as supplemental sensors. • The Thermal and Electrical Conductivity Probe (TECP), flown on MECA/Phoenix, which measures heat capacity, thermal conductivity, electrical resistance, and electrical permittivity between needles inserted into the soil. The TECP also measured atmospheric humidity, a capability that will be retained to search for subsurface H2O ice. The Mars TECP weighed 100-gram and by definition was at TRL 9. The lunar version (LIRA) is TRL 4. • The Perchlorate (ClO4) sensor is based on the fluorescence property of perchlorate (Mg, Fe, Na). We added a light source to excite the perchlorate (ClO4) and a photo diode to collect the emission wavelength. A sun-shade over the photo diode blocks out the ambient light during day light hours. The unifying goal of LIRA is to deliver a complete, integrated experiment suite that investigates properties that must be measured in situ, and provides the capability to power the suite at night or in PSRs, as well as a means to simulate aspects of the diurnal transition by delivering an optical pulse to the surface with intensity comparable to sunlight. We describe the scientific context of LIRA, touching on the electrical state of the near-surface environment, the thermal properties of the undisturbed regolith, and the distribution, geochemistry, and mobility of water. We also address the exploration implications of the work, examining hazards and resources in the context of strategic knowledge gaps (SKGs).

Heather Smith↗

MECA TECP Testing and Experimentation

MECA (the Microscopy, Electrochemistry, Conductivity Analyzer) is an instrument on the Phoenix 2007 mission to Mars designed to investigate the properties of high-latitude Martian soils. One of the MECA components, TECP (the Thermal and Electrical Conductivity Probe) is in an advanced stage of hardware development but requires testing and characterization. Two separate experiments are examined to attempt to answer open questions regarding the operation of the TECP. The humidity sensor tests showed a number of important details about the operation and design of the humidity sensor integrated on the TECP. The second experiment focused on the details of how the TECP contacts the soil it is inserted into and provided important answers to questions regarding the viability of this method of characterizing soils.

Tollerud, Erik J.↗