Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrodes, Implanted”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Altered Regional Homogeneity and Functional Connectivity during Microlesion Period after Deep Brain Stimulation in Parkinson’s Disease

Background. Patients with Parkinson’s disease (PD) undergoing deep brain electrode implantation experience a temporary improvement in motor symptoms before the electrical stimulation begins. We usually call this the microlesion effect (MLE), but the mechanism behind it is not clear. Purpose. This study aimed to assess the alterations in brain functions at the regional and whole-brain levels, using regional homogeneity (ReHo) and functional connectivity (FC), during the postoperative microlesion period after deep brain stimulation (DBS) in PD patients. Method. Resting-state functional MRI data were collected from 27 PD patients before and after the first day of DBS and 12 healthy controls (HCs) in this study. The ReHo in combination with FC analysis was used to investigate the alterations of regional brain activity in all the subjects. Results. There were increased ReHo in the basal ganglia-thalamocortical circuit (left supplementary motor area and bilateral paracentral lobule), whereas decreased ReHo in the default mode network (DMN) (left angular gyrus, bilateral precuneus), prefrontal cortex (bilateral middle frontal gyrus), and the cerebello-thalamocortical (CTC) circuit (Cerebellum_crus2/1_L) after DBS. In addition, we also found abnormal FC in the lingual gyrus, cerebellum, and DMN. Conclusion. Microlesion of the thalamus caused by electrode implantation can alter the activity of the basal ganglia-thalamocortical circuit, prefrontal cortex, DMN, and CTC circuit and induce abnormal FC in the lingual gyrus, cerebellum, prefrontal cortex, and DMN among PD patients. The findings of this study contribute to the understanding of the mechanism of MLE.

Luo, Bei↗

Enhancements to Lab-on-a-Fish Technology: Final Report for I3T Project 81245

PNNL has engaged in discussions with several organizations regarding potential future collaborations. PNNL has developed the Lab-on-a-Fish prototypes and produced video instructions for an organization conducting research on shark eggs. Several organizations have expressed interest in using the Lab-on-a-Fish for their studies. We’ve also updated two versions of the Lab-on-a-Fish to expand its applications to a wider range of animal studies and accelerate its commercialization. The new design of the Lab-on-a-Fish, which incorporates PCB-based electrodes, has demonstrated the ability to capture clear ECG signals without the need for additional needle-shaped electrodes. This innovation eliminates the need for implanting electrodes beneath the fish's skin at specific locations, which is required with the current version of Lab-on-a-Fish. This change significantly simplifies the manufacturing and implantation process. For the Lab-on-a-Fish design that uses an optical pulse oximeter, the measurement results were primarily influenced by respiratory activity rather than heart rate. This occurred because the oximeter was placed beneath the operculum. Further research and development are needed to explore more suitable locations and methods for accurate pulse oximeter measurements.

59 BASIC BIOLOGICAL SCIENCES↗

Neural interface methods and apparatus to provide artificial sensory capabilities to a subject

Embodiments of neural interfaces according to the present invention comprise sensor modules for sensing environmental attributes beyond the natural sensory capability of a subject, and communicating the attributes wirelessly to an external (ex-vivo) portable module attached to the subject. The ex-vivo module encodes and communicates the attributes via a transcutaneous inductively coupled link to an internal (in-vivo) module implanted within the subject. The in-vivo module converts the attribute information into electrical neural stimuli that are delivered to a peripheral nerve bundle within the subject, via an implanted electrode. Methods and apparatus according to the invention incorporate implantable batteries to power the in-vivo module allowing for transcutaneous bidirectional communication of low voltage (e.g. on the order of 5 volts) encoded signals as stimuli commands and neural responses, in a robust, low-error rate, communication channel with minimal effects to the subjects' skin.

Buerger, Stephen P.↗

Boron‐Doped Nano‐Crystalline Coated Carbon Fibers for Phasic Dopamine Sensing

Real time, chronic electrochemical detection of neurotransmitters will provide a positive step in the treatment and understanding of neurological disease. However, current electrodes using carbon fibers (CF) fail to perform chronically. While diamond-based coatings show promise in improving their longevity, achieving a uniform layer of such coatings on CFs is challenging, and the electrodes often lose sensitivity after coating. In this work, a complete and uniform boron-doped nanocrystalline material grown in a diamond reactor (B-NCD) was developed to coat CF microelectrodes for neurochemical sensing. The coating was characterized electrically, optically, mechanically, and chemically. The B-NCD coated CF electrodes were able to detect phasic dopamine at a sensitivity comparable to the most widely used alternatives (uncoated and PEDOT:Nafion coated CFs). During biofouling testing, the B-NCD coated CF electrodes demonstrated better stability than uncoated CFs and comparable performance to PEDOT:Nafion coated CFs. Moreover, B-NCD exhibited no signs of degradation during consecutive FSCV applications, while uncoated and PEDOT:Nafion coated CF electrodes degraded significantly over time. Furthermore, the B-NCD coating supported the survival and development of neurons and astrocytes in vitro, exhibited excellent adhesion and durability during mechanical bending testing, and enabled successful in vivo recording of phasic dopamine release in the rat brain. Overall, B-NCD coated CFs present as an ideal candidate for chronic, flexible neural implantable electrodes for long-term neurochemical monitoring.

carbon fiber↗

Electrophoretic Deposition of Platinum Nanoparticles using Ethanol-Water Mixtures Significantly Reduces Neural Electrode Impedance

We report platinum electrodes are critical components in many biomedical devices, an important example being implantable neural stimulation or recording electrodes. However, upon implantation, scar tissue forms around the electrode surface, causing unwanted deterioration of the electrical contact. We demonstrate that sub-monolayer coatings of platinum nanoparticles (PtNPs) applied to 3D neural electrodes by electrophoretic deposition (EPD) can enhance the electrode's active surface area and significantly lower its impedance. In this work we use ethanol-water mixtures as the EPD solvent, in contrast to our previous studies carried out in water. We show that EPD coating in 30 vol.% ethanol improves the device's electrochemical performance. Computational mesoscale multiparticle simulations were for the first time applied to PtNP-on-Pt EPD, revealing correlations between ethanol concentration, electrochemical properties, and coating homogeneity. Thereto, this optimum ethanol concentration (30 vol.%) balances two opposing trends: (i) the addition of ethanol reduces water splitting and gas bubble formation, which benefits surface coverage, and (ii) increased viscosity and reduced permittivity occur at high ethanol concentrations, which impair the coating quality and favoring clustering. A seven-fold increase in active surface area and significantly reduced in vitro impedance of the nano-modified neural stimulation electrode surfaces highlight the influence of ethanol-water mixtures in PtNP EPD.

36 MATERIALS SCIENCE↗

Sex Differences in Vagus Nerve Stimulation Effects on Rat Cardiovascular and Immune Systems

Background: Investigations into the benefits of vagus nerve stimulation (VNS) through pre-clinical and clinical research have led to promising findings for treating several disorders. Despite proven effectiveness of VNS on conditions such as epilepsy and depression, understanding of off-target effects and contributing factors such as sex differences can be beneficial to optimize therapy design. New Methods: In this article, we assessed longitudinal effects of VNS on cardiovascular and immune systems, and studied potential sex differences using a rat model of longterm VNS. Rats were implanted with cuff electrodes around the left cervical vagus nerve for VNS, and wireless physiological monitoring devices for continuous monitoring of cardiovascular system using electrocardiogram (ECG) signals. ECG morphology and heart rate variability (HRV) features were extracted to assess cardiovascular changes resulting from VNS in short-term and long-term timescales. We also assessed VNS effects on expression of inflammatory cytokines in blood during the course of the experiment. Statistical analysis was performed to compare results between Treatment and Sham groups, and between male and female animals from Treatment and Sham groups. Results: Considerable differences between male and female rats in cardiovascular effects of VNS were observed in multiple cardiovascular features. However, the effects seemed to be transient with approximately 1-h recovery after VNS. While short-term cardiovascular effects were mainly observed in male rats, females in general showed more significant long-term effects even after VNS stopped. We did not observe notable changes or sex differences in systemic cytokine levels resulting from VNS. Comparison With Existing Methods: Compared to existing methods, our study design incorporated wireless physiological monitoring and systemic blood cytokine level analysis, along with long-term VNS experiments in unanesthetized rats to study sex differences. Conclusion: The contribution of sex differences for long-term VNS off-target effects on cardiovascular and immune systems was assessed using awake behaving rats. Although VNS did not change the concentration of inflammatory biomarkers in systemic circulation for male and female rats, we observed significant differences in cardiovascular effects of VNS characterized using ECG morphology and HRV analyses.

59 BASIC BIOLOGICAL SCIENCES↗

A method to observe field-region oxide charge and inter-electrode isolation from CV-characteristics of n-on-p devices

Abstract N-on-psilicon sensors will be utilized in the Compact Muon Solenoid (CMS) detector's tracker and High Granularity Calorimeter (HGCAL) in the High Luminosity upgrade of the Large Hadron Collider (HL-LHC). Among their several advantages in terms of radiation hardness over the traditionalp-on-nsensors in the extreme radiation environment of the HL-LHC are electron collection instead of holes and overlapping maxima of weighting and electric fields at the charge-collecting electrodes. The disadvantage of the multi-channel SiO 2 -passivatedn-on-psensors is the generation of an inversion layer under the Si/SiO 2 -interface by a positive interface-oxide-charge (N ox ) that at high densities can compromise the position resolution by creating a conduction channel between the electrodes. This issue is typically addressed by including additional isolnts (p-stp,p-spray) between n + -electrodes. Focusing on the guard-ring regions ofn-on-psensors where no isolation implants are applied between the electrodes, a capacitance-voltage (CV) characterization study of both 6-inch wafer test diodes and 8-inch HGCAL prototype and pre-series sensors showed a distinct threshold voltage (V th,iso ) in theCV-characteristics of a biased n + -electrode when its enclosing guard-ring was left floating. When reproduced by simulations, the measuredV th,iso was found to contain information on the field-regionN ox and indicate the threshold where the two electrodes become electrically isolated by the influence of the reverse bias voltage. Together with previous studies on the inter-electrode isolation of irradiatedn-on-psensors, the results indicate that position sensitiven-on-psensors without isolation implants may be feasible in future HEP experiments.

Instruments & Instrumentation↗

Silicon strip defects and their impact on electrical performance of readout electronics

Abstract In preparation for the High Luminosity LHC (HL-LHC) runs, the ATLAS inner detector will be completely replaced with an all silicon Inner Tracker (ITk). Hybrid silicon pixel modules will be used for the innermost tracking layers, and silicon micro-strip detectors will be used the outer layers of the tracker. During the production of the detector, the sensors, readout electronics, and other components will undergo a series of quality control (QC) and quality assurance tests. Defects in the fabrication of the sensors will be flagged early in the manufacturer's and ATLAS QC tests. A study of the influence of sensor defects was performed to assess the characteristics of these defects in completed modules, and whether any defect posed a risk to the operation of the front-end readout electronics. All defects were found to have no impact on the performance of the front-end readout electronics for healthy amplifier channels, and defects that short the coupling between the strip implant and the metal readout electrode were only noticeable for strip leakage currents in excess of 250 nA, beyond the end-of-life currents expected for most sensors at the HL-LHC.

Instruments & Instrumentation↗

Silicon pinhole strip defects and their impact on ATLAS Inner Tracker HV current measurement

In preparation for the High-Luminsity LHC (HL-LHC) [1], the ATLAS detector will undergo major detector upgrades, including the replacement of the current Inner Detector with the new all-silicon Inner Tracker (ITk) [2]. The ITk consists of a pixel detector close to the beamline surrounded by a large-area strip detector. During detector production, the electrical properties of silicon sensors and readout electronics must be characterized through a series of quality control (QC) and quality assurance tests. These tests ensure any defect is captured at the earliest possible stage. One such defect, callled a pinhole, occurs when the strip implant and the metal readout electrode are shorted through the intermediary dielectric layer. Notably, the introduction of pinholes during module assembly and pinhole effects on completed modules, especially on leakage current measurement circuitry, have never been studied. In this paper, we investigate the effect of such connections on the sensor leakage current measurements of completed modules and introduce new ways to locate pinholed strips. Here, with minor modifications to testing procedures, such defects are shown not to impede module testing or performance.

FOS: Physical sciences↗

Modeling of surface-state induced inter-electrode isolation of n -on- p devices in mixed-field and γ -irradiation environments

Position sensitive n-on-p silicon sensors will be utilized in the tracker and in the High Granularity Calorimeter (HGCAL) of the Compact Muon Solenoid (CMS) experiment at High Luminosity Large Hadron Collider (HL-LHC). The detrimental effect of the radiation-induced accumulation of positive net oxide charge on position resolution in n-on-p sensors has typically been countered by the application of isolation implants like p-stop or p-spray between n + -electrodes. In addition to the positively charged layer inside the oxide and close to the Si/SiO 2 -interface, surface damage introduced by ionizing radiation in SiO 2 -passivated silicon particle detectors includes the accumulation of trapped-oxide-charge and interface traps. A previous study of either n/γ (mixed field)- or γ-irradiated Metal-Oxide-Semiconductor (MOS) capacitors showed evidence of substantially higher introduction rates of acceptor- and donor-type deep interface traps (N it,acc/don ) in mixed-field environment. Here, in this work, an inter-pad and -strip resistance (or resistivity (ρ int )) simulation study of n-on-p sensors with and without p-stop isolation implants was conducted for both irradiation types. Higher levels of ρint showed correlation to higher densities of deep N it,acc/don , with the inter-pad isolation performance of the mixed-field irradiated sensors becoming independent of the presence of p-stop implant between the n + - electrodes up to about 100 kGy. The low introduction rates of deep N it,acc/don in γ-irradiated sensors resulted in high sensitivity of ρ int to the presence and peak doping of p-stop above the lowest dose of about 7 kGy in the study. As a consequence of the advantageous influence of radiation-induced accumulation of deep N it on the inter-electrode isolation, position sensitive n-on-p sensors without isolation implants may be considered for future HEP-experiments where the radiation is largely due to hadrons.

Akchurin, N. [Texas Tech Univ., Lubbock, TX (Unite↗

Influence of substrate composition on size and chemical state of ion beam synthesised Co nanoparticles – Towards fabrication of electrodes for energy devices

A one-step approach to synthesize ultrafine transition metal particles (size < 5 nm) in carbon substrates is highly desirable for fabricating electrodes for energy devices. Herein, cobalt ion implantation into amorphous carbon films (a:C) and hydrogenated amorphous carbon films (a:CH) was explored, with the aim of synthesizing ultrafine metallic cobalt nanoparticles at room temperature. Co ions of 30 keV energy were implanted into the carbon films to achieve a Co areal density of 1.0 ± 0.1 × 10 17 atoms cm -2 . Rutherford backscattering measurements revealed that hydrogenated amorphous carbon films gave a broader Co depth distribution compared to the amorphous carbon films. Further, cross-sectional TEM analysis revealed that hydrogenated carbon films suppressed metallic Co nanoparticle aggregation, leading to the creation of ultrafine Co nanoparticles (size < 5 nm). Co L-edge X-ray absorption spectroscopy measurements confirmed the formation of predominantly metallic Co nanoparticles by ion implantation. Results conclusively demonstrate that the presence of hydrogen (~ 28 at%) in the carbon matrix facilitates the synthesis of ultrafine metallic Co nanoparticles during Co ion implantation.

36 MATERIALS SCIENCE↗

High-Voltage CMOS Active Pixel Sensor

The high-voltage CMOS (HVCMOS) sensors are a novel type of CMOS active pixel sensors for ionizing particles that can be implemented in CMOS processes with deep n-well option. The pixel contains one sensor electrode formed with a deep n-well implanted in a p-type substrate. CMOS pixel electronics, embedded in shallow wells, are placed inside the deep n-well. By biasing the substrate with a high negative voltage and by the use of a lowly doped substrate, a depleted region depth of at least 30 µm can be achieved. The electrons generated by a particle are collected by drift, which induces fast detectable signals. This publication presents a 4.2-cm 2 large HVCMOS pixel sensor implemented in a commercial 180-nm process on a lowly doped substrate and its characterization.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

System and method for all optical electrode interface for bioengineering application

The present disclosure relates to an electro-optical modulator system having a source laser which generates an input optical signal. The input optical signal is received by an electro-optical module. The electro-optical module is implantable into an anatomy and includes a plurality of pixels. Each pixel has associated therewith an electrode and an optical modulator subsystem. The electrode receives electrical signals from the anatomy. The optical modulator subsystem receives the input optical signal and modulates the input optical signal to generate modulated optical output signals in relation to the received electrical signals. A detector subsystem may be used to receive and collect the modulated optical output signals.

Patra, Susant K.↗

A study on sub-bandgap photoexcitation in nitrogen- and boron-doped diamond with interdigitated device structure

Diamond is an ultrawide-bandgap semiconductor suitable for high power devices that require high current carrying capacity, high blocking voltages, and smaller form factors. We investigated various diamond structures for extrinsic photoconductive semiconductor switches, including an insulating high-pressure high-temperature type Ib (highly nitrogen-doped) substrate, a chemical vapor deposited (CVD) type IIa (unintentionally doped) substrate, a CVD grown semiconducting boron-doped epilayer on a type IIa substrate, and boron-implanted type Ib and IIa substrates. Using these samples, we fabricated and characterized planar interdigitated photoconductive switches with 30 μm, electrode gaps. 532 and 1064 nm Nd:YAG laser pulses with energies up to 3.5 mJ/pulse were used to trigger the switches. Photoresponses were measured at bias voltages ranging from 10 to 100 V, corresponding to electric fields of 3.3–33 kV/cm. In this field range, the type Ib device exhibited the highest average on/off-state current ratio, on the order of 10 11 , when triggered with 0.8 mJ/pulse, 532 nm laser pulses. However, only the CVD grown boron-doped epilayer and boron implanted IIa devices showed decent sensitivity to 1064 nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-Density, Actively Multiplexed µECoG Array on Reinforced Silicone Substrate

Simultaneous interrogation of electrical signals from wide areas of the brain is vital for neuroscience research and can aid in understanding the mechanisms of brain function and treatments for neurological disorders. There emerges a demand for development of devices with highly conformal interfaces that can span large cortical regions, have sufficient spatial resolution, and chronic recording capability while keeping a small implantation footprint. In this work, we have designed 61 channel and 48 channel high-density, cortical, micro-electrocorticographic electrode arrays with 400 µm pitch on an ultra-soft but durable substrate. We have also developed a custom multiplexing integrated circuit (IC), methods for packaging the IC in a water-tight liquid crystal polymer casing, and a micro-bonding method for attaching the electronics package to the electrode array. With the integrated multiplexer, the number of external wire connections can be reduced to 16 wires, thereby diminishing the invasive footprint of the device. Both the electrode array and IC were tested in vivo in a rat model to demonstrate the ability to sense finely-localized electrophysiological signals.

Rachinskiy, Iakov↗