Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrodynamic Modal Shakers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Challenges and Considerations When Using Hydraulic Modal Shaking in Large-Scale Modal Testing

As test articles become dimensionally larger, more complex, and massive in weight, combined with the need to excite them to higher than traditional levels in order to identify their nonlinear characteristics, modal shakers that can generate significantly higher force levels, have longer stroke lengths, and possess higher velocity limits are required. While large scale modal tests may be performed with electrodynamic modal shakers, hydraulic modal shakers become attractive since they can generate higher force levels at lower unit cost with a smaller spatial footprint. While test engineers familiar with electrodynamic modal shakers are familiar with the challenges of displacement and velocity limits and the relatively mild shaker nonlinear distortion due to amplifier gains and shaker flexure structural geometric nonlinearities, they probably are not as familiar with the unique set of challenges hydraulic modal shakers present. These unique challenges include significant nonlinear distortion in the shaker force, issues with the setup of the hydraulic power supply and the associated hydraulic hosing, velocity limits as they relate to potentially damaging the hydraulic actuator piston, and safety issues with operating high-pressure hydraulic systems. This paper addresses these unique challenges to help the test engineer to better utilize hydraulic modal shakers on large-scale modal tests.

Distortion↗

Challenges and Considerations When Using Hydraulic Modal Shaking in Large-Scale Modal Testing IMAC-XL

As test articles become dimensionally larger, more complex, and massive in weight, combined with the need to excite them to higher than traditional levels in order to identify their nonlinear characteristics, modal shakers that can generate significantly higher force levels, have longer stroke lengths, and possess higher velocity limits are required. While large scale modal tests may be performed with electrodynamic modal shakers, hydraulic modal shakers become attractive since they can generate higher force levels at lower unit cost with a smaller spatial footprint. While test engineers familiar with electrodynamic modal shakers are familiar with the challenges of displacement and velocity limits and the relatively mild shaker nonlinear distortion due to amplifier gains and shaker flexure structural geometric nonlinearities, they probably are not as familiar with the unique set of challenges hydraulic modal shakers present. These unique challenges include significant nonlinear distortion in the shaker force, issues with the setup of the hydraulic power supply and the associated hydraulic hosing, velocity limits as they relate to potentially damaging the hydraulic actuator piston, and safety issues with operating high-pressure hydraulic systems. This paper addresses these unique challenges to help the test engineer to better utilize hydraulic modal shakers on large-scale modal tests.

Distortion↗

Combined Qualification Vibration Testing and Fixed Base Modal Testing Utilizing a Fixed Based Correction Method

Vibration testing spaceflight hardware is a vital, but time consuming and expensive endeavor. Traditionally modal tests are performed at the component, subassembly, or system level, preferably free-free with mass loaded interfaces or fixed base on a seismic mass to identify the fundamental structural dynamic (modal) characteristics. Vibration tests are then traditionally performed on single-axis slip tables at qualification levels that envelope the maximum predicted flight environment plus 3 dB and workmanship in order to verify the spaceflight hardware can survive its flight environment. These two tests currently require two significantly different test setups, facilities, and ultimately reconfiguration of the spaceflight hardware. The vision of this research is to show how traditional fixed-base modal testing can be accomplished using vibration qualification testing facilities, which not only streamlines testing and reduces test costs, but also opens up the possibility of performing modal testing to untraditionally high excitation levels that provide for test-correlated finite element models to be more representative of the spaceflight hardware's response in a flight environment. This paper documents the first steps towards this vision, which is the comparison of modal parameters identified from a traditional fixed-based modal test performed on a modal floor and those obtained by utilizing a fixed based correction method with a large single-axis electrodynamic shaker driving a slip table supplemented with additional small portable shakers driving on the slip table and test article. To show robustness of this approach, the test article chosen is a simple linear weldment, whose mass, size, and modal parameters couple well with the dynamics of the shaker/slip table. This paper will show that all dynamics due to the shaker/slip table were successfully removed resulting in true fixed-base modal parameters, including modal damping, being successfully extracted from a traditional style base-shake vibration test setup.

Winkel, James P.↗

Combined Qualification Vibration Testing and Fixed Base Modal Testing Utilizing a Fixed Based Correction Method

Vibration testing spaceflight hardware is a vital, but time consuming and expensive endeavor. Traditionally modal tests are performed at the component, subassembly, or system level, preferably free-free with mass loaded interfaces or fixed base on a seismic mass to identify the fundamental structural dynamic (modal) characteristics. Vibration tests are then traditionally performed on single-axis slip tables at qualification levels that envelope the maximum predicted flight environment and workmanship in order to verify the spaceflight hardware can survive its flight environment. These two tests currently require two significantly different test setups, facilities, and ultimately reconfiguration of the spaceflight hardware. The vision of this research is to show how traditional fixed-base modal testing can be accomplished using vibration qualification testing facilities, which not only streamlines testing and reduces test costs, but also opens up the possibility of performing modal testing to untraditionally high excitation levels that provide for test-correlated finite element models to be more representative of the spaceflight hardware's response in a flight environment. This paper documents the first steps towards this vision, which is the comparison of modal parameters identified from a traditional fixed-based modal test performed on a modal floor and those obtained by utilizing a fixed based correction method with a large single-axis electrodynamic shaker driving a slip table supplemented with additional small portable shakers driving on the slip table and test article. To show robustness of this approach, the test article chosen is a simple linear weldment, whose mass, size, and modal parameters couple well with the dynamics of the shaker/slip table. This paper will show that all dynamics due to the shaker/slip table were successfully removed resulting in true fixed-base modal parameters, including modal damping, being successfully extracted from a traditional style base-shake vibration test setup.

Base-Shake↗

Model Validation of an RSRM Transporter Through Full-scale Operational and Modal Testing

The Reusable Solid Rocket Motor (RSRM) segments, which are part of the current Space Shuttle system and will provide the first stage of the Ares launch vehicle, must be transported from their manufacturing facility in Promontory, Utah, to a railhead in Corinne, Utah. This approximately 25-mile trip on secondary paved roads is accomplished using a special transporter system which lifts and conveys each individual segment. ATK Launch Systems (ATK) has recently obtained a new set of these transporters from Scheuerle, a company in Germany. The transporter is a 96-wheel, dual tractor vehicle that supports the payload via a hydraulic suspension. Since this system is a different design than was previously used, computer modeling with validation via test is required to ensure that the environment to which the segment is exposed is not too severe for this space-critical hardware. Accurate prediction of the loads imparted to the rocket motor is essential in order to prevent damage to the segment. To develop and validate a finite element model capable of such accurate predictions, ATA Engineering, Inc., teamed with ATK to perform a modal survey of the transport system, including a forward RSRM segment. A set of electrodynamic shakers was placed around the transporter at locations capable of exciting the transporter vehicle dynamics. Forces from the shakers with varying phase combinations were applied using sinusoidal sweep excitation. The relative phase of the shaker forcing functions was adjusted to match the shape characteristics of each of several target modes, thereby customizing each sweep run for exciting a particular mode. The resulting frequency response functions (FRF) from this series of sine sweeps allowed identification of all target modes and other higher-order modes, allowing good comparison to the finite element model. Furthermore, the survey-derived modal frequencies were correlated with peak frequencies observed during road-going operating tests. This correlation enabled verification of the most significant modes contributing to real-world loading of the motor segment under transport. After traditional model updating, dynamic simulation of the transportation environment was compared to the measured operating data to provided further validation of the analysis model. KEYWORDS Validation, correlation, modal test, rocket motor, transporter

Brillhart, Ralph↗

Evaluation of mounting bolt loads for Space Shuttle Get Away Special (GAS) adapter beam

During the prototype vibration tests of the GAS adapter beam, significant impacting of the beam at its support points was observed. The cause of the impacting was traced to gaps under the mounting bolt heads. Because of the nonlinear nature of the response, it was difficult to evaluate the effects which Shuttle launch dynamics might have on the mounting bolt loads. A series of tests were conducted on an electrodynamic exciter in which the transient acceleration time histories, which had been measured during the Space Transportation System-1 (STS-1; Space Shuttle mission 1) launch, were simulated. The actual flight data had to be filtered and compensated so that it could be reproduced on the shaker without exceeding displacement and velocity limitations. Mounting bolt loads were measured directly by strain gages applied to the bolts. Various gap thicknesses and bolt torques were investigated. Although increased gap thickness resulted in greater accelerations due to impacting, the bolt loads were not significantly affected. This is attributed to the fact that impacting excited mostly higher frequency modes which do not have significant modal mass.

Talapatra, D. C.↗