At least 19 records

Electrolyzers in focus: advances in CO 2 electrolyzer designs

Electrochemical CO 2 reduction (ECR) remains a viable method to reintegrate anthropogenic CO 2 into current energy infrastructures through its conversion into commodity chemicals. To facilitate the integration of ECR, electrochemical devices called electrolyzers must be implemented to overcome the inherent limitations that exist in current ECR experiments, namely kinetics and mass transport. In this review, we outline the current and advancing designs in ECR electrolyzers, with a focus on the following five electrochemical devices: membrane electrode assemblies (MEA), flow cell (FC), rotating disk electrode (RDE), rotating ring-disk electrode (RRDE), and rotating cylinder electrode (RCE). We highlight the tunable components of each electrolyzer with a forward outlook on the optimization and relevance of electrolyzer designs in upcoming ECR applications.

CO2 reduction↗

Performance and Durability of Pure-Water-Fed Anion Exchange Membrane Electrolyzers Using Baseline Materials and Operation

Water electrolysis powered by renewable electricity produces green hydrogen and oxygen gas, which can be used for energy, fertilizer, and industrial applications and thus displace fossil fuels. Pure-water anion-exchange-membrane (AEM) electrolyzers in principle offer the advantages of commercialized proton-exchange-membrane systems (high current density, low cross over, output gas compression, etc.) while enabling the use of less-expensive steel components and nonprecious metal catalysts. AEM electrolyzer research and development, however, has been limited by the lack of broadly accessible materials that provide consistent cell performance, making it difficult to compare results across studies. Further, even when the same materials are used, different pretreatments and electrochemical analysis techniques can produce different results. Here, we report an AEM electrolyzer comprising commercially available catalysts, membrane, ionomer, and gas-diffusion layers operating near 1.9 V at 1 A cm –2 in pure water. After the initial break in, the performance degraded by 0.67 mV h –1 at 0.5 A cm –2 at 55 °C. We detail the key preparation, assembly, and operation techniques employed and show further performance improvements using advanced materials as a proof-of-concept for future AEM-electrolyzer development. Here, the data thus provide an easily reproducible and comparatively high-performance baseline that can be used by other laboratories to calibrate the performance of improved cell components, nonprecious metal oxygen evolution, and hydrogen evolution catalysts and learn how to mitigate degradation pathways.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrolyzer energy dominates separation costs in state-of-the-art CO 2 electrolyzers: Implications for single-pass CO 2 utilization

In low-temperature CO 2 electrolysis, a fundamental trade-off exists between maximizing electrolyzer performance and minimizing downstream CO 2 recovery. Here, by coupling a down-the-gas-channel electrolyzer model with a techno-economic analysis, we find that the optimal single-pass CO 2 conversion for ethylene production is typically low—on the order of 5%–10%—although larger optima are found if the H 2 faradic efficiency is very low. Similarly, strategies for eliminating carbonate crossover require more energy than downstream gas separation if they increase the cell potential by ~0.2 V; however, when CAPEX are accounted for, this “break-even” voltage increases to ~ 0.4 to 0.8 V for electricity prices varying from 6c/kWh to 1.5c/kWh. These findings are a consequence of the low energy requirements of industrial gas separation relative to electrochemical CO 2 reduction. Under most circumstances, maintaining near-optimal electrolyzer performance is more important than reducing or eliminating downstream gas separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Reference Electrodes in Anion-Exchange-Membrane Electrolyzers: Impact of Stainless-Steel Gas-Diffusion Layers and Internal Mechanical Pressure

Alkaline-membrane electrolyzers operating in pure water might provide scalable low-cost H 2 production but currently lag in performance and durability compared to commercial technologies. Typically, membrane–electrode assemblies (MEAs) are optimized in electrolyzers by changing one parameter at a time and assessing the resulting system performance via two-electrode polarization and impedance measurements. These approaches are limited in their ability to assign performance changes and durability to specific electrodes or processes. We integrate a reference electrode with the MEA to separate anode and cathode responses in both polarization and impedance measurements. Here we illustrate the power of the approach by showing how the fiber diameter of stainless-steel gas-diffusion layers (GDLs) affects performance solely at the anode, while changing the thickness of the cathode GDL simultaneously affects the performance of the anode and cathode due to changes in internal pressure from mechanical compression. This finding was obscured in conventional two-electrode measurements. The work thus guides both high-performance alkaline-membrane water-electrolyzer development and illustrates a useful strategy to study structure–activity relationships in the MEA.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Increasing the Electrolyte Salinity to Improve the Performance of Anion Exchange Membrane Water Electrolyzers

Direct operation of anion exchange membrane water electrolyzers (AEMWEs) with near-neutral pH feeds avoids the use of highly alkaline and corrosive solutions. However, using neutral pH solutions currently faces fundamental operational challenges that diminish performance and reduce long-term stability due to poor solution conductivity and low hydroxide ion concentration. Here, we showed that amending near-neutral pH solutions with low concentrations of alkali metal salts in a dry-cathode configuration substantially improved performance and stability. Adding NaClO 4 (10 mM) to the anolyte reduced the operating voltage by 0.19 to 2.58 V at 500 mA/cm 2 compared to non-saline solutions (2.77 V). However, further increases in the feed salt concentration (100 mM NaClO 4 ) reduced performance (2.64 V) due to a greater co-ion diffusion through the anion exchange membrane. Electrolyzer performance was further improved by utilizing salts with high conductivity such as KNO 3 . Using a saline anolyte reduced ohmic resistance, resulting in smaller applied voltage and energy consumption for hydrogen generation, while the combined effect of the membrane charge and the electric field direction in the dry-cathode feed configuration minimized ion crossover. Thus, increasing the salinity of near-neutral pH solutions represents a cost-effective strategy to improve the performance of AEMWE compared to ultrapure electrolytes, minimizing risks and costs associated with recirculating highly alkaline solutions.

anion exchange membrane water electrolyzer↗

Electrochemical Conversion of CO 2 to Methyl Formate in a Flow Electrolyzer with Mixed Propylene Carbonate/Methanol Catholyte

Despite the promise of electrochemical carbon dioxide reduction as a technology for the production of clean fuels and decarbonization of the chemical industry, research has mostly focused on aqueous systems with a relatively limited set of products that have been achieved via electrosynthesis. Increasingly, CO 2 electroreduction in nonaqueous solvents is being pursued to develop new avenues for expanding the suite of products that can be made with high selectivity. CO 2 reduction in alcohols coupled with in situ esterification to produce esters is one such route that utilizes nonaqueous electrolyte. To be practical, such electrochemical syntheses need to be translated to a high-performance reactor such as a flow electrolyzer. However, many organic solvents, such as alcohols, wet and flood porous electrodes, thus impeding reactor performance. In this work, methanol was mixed with propylene carbonate as a catholyte for a gas-fed CO 2 flow electrolyzer that avoided cathode flooding. Simultaneously, a dual aqueous anolyte was used for water oxidation as a scalable and sustainable anodic half-reaction. The performance effect of methanol concentration, catholyte acidity, CO 2 flow rate, and dilute water in the catholyte were investigated. With 10 vol % methanol in 90 vol % propylene carbonate, 63% faradaic efficiency for methyl formate ester product was sustained without cathode flooding. However, improvements are still needed to lower the cell resistance and further increase the operating current density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of Sr-Containing Secondary Phases on Oxide Conductivity in Solid-Oxide Electrolyzer Cells

Solid-oxide electrolyzer cells (SOECs) based on a yttria-stabilized zirconia (YSZ) oxide electrolyte produce hydrogen from water with the assistance of excess thermal energy; however, Sr diffusion within the Gd-doped CeO 2 (GDC) barrier layer during processing or operation can lead to the formation of unwanted secondary phases such as SrO and SrZrO 3 . Here, to establish and compare the degree of impact of these phases on SOEC performance, we conduct first-principles calculations to study their bulk oxide conductivities and compare them to that of the YSZ electrolyte. We find that SrO has a low conductivity arising from the poor mobility and low concentration of mobile oxygen vacancies, and its presence in SOECs should therefore be avoided. SrZrO 3 also has a lower oxide conductivity than YSZ; however, this discrepancy is primarily due to lower vacancy concentrations rather than low mobility. We find that sufficient levels of Y-doping on the Zr site can increase oxygen vacancy concentrations in SrZrO 3 to achieve an oxide ionic conductivity on par with that of YSZ, thereby mitigating any potential deleterious effect on transport performance. Energy-dispersive X-ray spectroscopy confirms that Y is the most common minority element present in SrZrO 3 forming near the GDC–YSZ interface, alleviating concerns regarding the impact of SrZrO 3 on device performance. These results from our combined computational–experimental analysis can inform future engineering strategies designed to limit the detrimental effects of Sr-induced secondary phase formation on SOEC performance.

08 HYDROGEN↗

Three-Electrode Study of Electrochemical Ionomer Degradation Relevant to Anion-Exchange-Membrane Water Electrolyzers

Among existing water electrolysis (WE) technologies, anion-exchange-membrane water electrolyzers (AEMWEs) show promise for low-cost operation enabled by the basic solid-polymer electrolyte used to conduct hydroxide ions. The basic environment within the electrolyzer, in principle, allows the use of non-platinum-group metal catalysts and less-expensive cell components compared to acidic-membrane systems. Nevertheless, AEMWEs are still underdeveloped, and the degradation and failure modes are not well understood. To improve performance and durability, supporting electrolytes such as KOH and K 2 CO 3 are often added to the water feed. The effect of the anion interactions with the ionomer membrane (particularly other than OH – ), however, remains poorly understood. We studied three commercial anion-exchange ionomers (Aemion, Sustainion, and PiperION) during oxygen evolution (OER) at oxidizing potentials in several supporting electrolytes and characterized their chemical stability with surface-sensitive techniques. We analyzed factors including the ionomer conductivity, redox potential, and pH tolerance to determine what governs ionomer stability during OER. Specifically, we discovered that the oxidation of Aemion at the electrode surface is favored in the presence of CO 3 2– /HCO 3 – anions perhaps due to the poor conductivity of that ionomer in the carbonate/bicarbonate form. Sustainion tends to lose its charge-carrying groups as a result of electrochemical degradation favored in basic electrolytes. PiperION seems to be similarly negatively affected by a pH drop and low carbonate/bicarbonate conductivity under the applied oxidizing potential. Furthermore, the insight into the interactions of the supporting electrolyte anions with the ionomer/membrane helps shed light on some of the degradation pathways possible inside of the AEMWE and enables the informed design of materials for water electrolysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thin Cation-Exchange Layers Enable High-Current-Density Bipolar Membrane Electrolyzers via Improved Water Transport

With suitable water dissociation (WD) catalysts, bipolar membranes (BPMs) can efficiently dissociate water into H + and OH – at the junction between anion- and cation-exchange layers (AEL and CEL, respectively). First, however, water must be transported through the AEL or CEL and thus against the outward flow of hydrated H + and OH – . This is a challenge intrinsic to the BPM architecture and limits operation to current densities typically less than ~0.5 A·cm –2 . Here we explore how water transport affects durability and performance in reference alkaline and acidic membrane electrolyzers, and we use the insight gained to design BPMs with improved water transport. We demonstrate a thin-CEL BPM (2-μm Nafion CEL|~200 nm TiO 2 |~200 nm NiO + ionomer|50 μm Sustainion AEL) which maintains a pH difference of ~14 units between the anode and cathode for current densities of up to 3.4 A·cm –2 with a total water electrolysis voltage of ~4 V and an estimated WD overpotential of ~1.5 V. Finally, such high-current-density operation is crucial for key emerging BPM applications, including in water and carbon-dioxide electrolyzers and in (regenerative) fuel cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ionomer Optimization for Water Uptake and Swelling in Anion Exchange Membrane Electrolyzer: Hydrogen Evolution Electrode

Green hydrogen produced through anion exchange membrane water electrolysis is a promising, low-cost chemical storage solution for intermittent renewable energy sources. Low-temperature electrolysis using anion exchange membranes (AEM) combines the benefits of established water electrolysis technologies based on alkaline electrolysis and proton exchange membrane electrolysis. The anion conductive ionomers (ACI) used in the AEM electrolyzer (AEMEL) electrodes has been investigated. The ACI serves two primary purposes: (i) facilitate hydroxide conduction between the catalyst and bulk electrolyte and (ii) bind the catalyst to the porous transport layer and membrane. High ion exchange capacity (IEC) ACIs are desired, however, high IEC can cause excessive water uptake (WU) and detrimental ACI swelling. Proper water management is a key factor in obtaining maximum performance in AEM-based devices. In this study, a series of poly(norbornene)-based ACIs were synthesized and deployed in hydrogen evolving AEMEL cathode electrodes. A balance between ionic conductivity, WU and ionomer swelling was achieved in the ACI by varying the IEC and degree of polymer cross-linking. It was found that higher IEC ACIs with light crosslinking are preferred in the HER electrode. Furthermore, such a configuration fine-tuned the WU and ionomer swelling to achieve optimum cell performance and reduce cell operating voltages.

08 HYDROGEN↗

Water-Fed Hydroxide Exchange Membrane Electrolyzer Enabled by a Fluoride-Incorporated Nickel–Iron Oxyhydroxide Oxygen Evolution Electrode

Here, we have developed a dissolved oxygen and galvanic corrosion method to synthesize vertically aligned fluoride-incorporated nickel–iron oxyhydroxide nanosheet arrays on a compressed Ni foam as an efficient self-supported oxygen evolution electrode. It is integrated with poly(aryl piperidinium) hydroxide exchange membrane and ionomers with high ion exchange capacity into a hydroxide exchange membrane electrolyzer fed with pure water, which achieves a performance of 1020 mA cm –2 at 1.8 V and prevents the detachment of catalysts during continuous operation (>160 h at 200 mA cm –2 ). Furthermore, this work provides a potential pathway for massively producing low-cost hydrogen using intermittent renewable energy sources.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Operating Strategies for Dispatchable PEM Electrolyzers that Enable Low-Cost Hydrogen Production

Hydrogen is a pathway to enabling decarbonization across multiple economic sectors that cannot be directly decarbonized with electricity including heat for industrial operations, medium- and heavy-duty transportation applications, long-duration energy storage, and as a feedstock for chemical synthesis. Producing hydrogen at low costs and carbon footprint is likely essential to economically decarbonize these otherwise "hard to decarbonize" sectors. Low-temperature polymer electrolyte membrane (PEM) electrolysis produces hydrogen from water and electricity and is a rapidly developing pathway towards making hydrogen at the scales required for decarbonization applications. The levelized cost of electrolytic hydrogen is dependent on the capital cost, efficiency, and durability of the electrolyzer system as well as the price of electricity supplied to the electrolyzer and the annual utilization of the electrolyzer (capacity factor). Electricity price and capacity factor depend on the source of energy that the system uses and impact other economic factors. Electricity price and capacity factor and the connections between other aspects of hydrogen production via PEM electrolyzers are the focus of this work. PEM electrolyzers have conventionally been operated at high capacity factors using electricity purchased from utilities with a constant price throughout the year. To achieve lower effective electricity prices, recent work has investigated opportunities for electrolyzers to purchase electricity in wholesale markets, where the cost of electricity varies hourly. This option can lead to lower electricity costs when the electrolyzer is a controllable load that ramps up and down rapidly and turns on and off frequently. This configuration and operating strategy capitalizes on times of low wholesale electricity prices and results in lower hydrogen levelized costs than constant operation due to reduced electricity costs even though the reduced capacity factor increases the cost of recovering the capital investment. Cycling on and off frequently also has implications for electrolyzer durability. An electrolyzer configuration where it is directly connected to renewable generation such as wind or solar, only running when the generator is producing energy, has similar implications on operating strategy, hydrogen levelized cost, capacity factor, and durability. This work provides insight into the relationships between dispatchable electrolyzer operating strategies and the cost of producing hydrogen from these systems, outlining strategies and opportunities to minimize production costs while minimizing operations that are likely to negatively impact system durability and efficiency. We find strategies that minimize electrolyzer cycling and the resulting durability impacts while increasing the hydrogen levelized cost only slightly above the minimum. We also find opportunities for batteries to minimize the number of cycles in systems directly connected to renewable generation. These findings outline key opportunities for future electrolyzer deployments and the synergistic benefits between electrolyzers and increased deployment of renewable energy generation like wind and solar. They also inform research and development that is reducing electrolyzer capital cost while managing durability impacts.

electricity markets↗

Manufacturing Cost Analysis for PEM Electrolyzers and Perspectives for Future Cost Reduction

Electrolyzer capital costs strongly influence the total levelized cost of hydrogen production and have implications for hydrogen deployment. Current electrolyzer costs are high, and large cost reductions may be needed to achieve competitive hydrogen costs and targets. Understanding pathways for cost reduction via R&D and deployment is a critical research area for informed energy planning and enabling hydrogen use. This work presents bottom-up cost estimates of polymer electrolyte membrane (PEM) electrolyzer systems tied to design specifications and discusses perspectives for cost reduction opportunities based on ongoing research. We use a detailed manufacturing and process model for a 1 MW PEM electrolyzer stack and balance of plant (BOP) for rigorous cost estimation. This allows for robust estimates of component and manufacturing costs and examination of key cost contributors. Stack costs are dominated by material costs such as iridium and platinum catalysts, especially at high manufacturing rates; power electronics and hydrogen purification equipment are the largest contributors to BOP cost. At higher manufacturing rates, better equipment utilization could reduce stack costs significantly, and we estimate that experience and bulk purchasing will allow for cost reductions to some BOP components. Still, many well-established BOP technologies and stack material costs are less likely to see significant cost reductions at high manufacturing rates. As such, manufacturing scale is limited in how much it can reduce electrolyzer costs, and additional advances for cost reduction may be needed to achieve cost targets. It will likely take many combined strategies to achieve significant cost reductions for electrolyzers and enable low-cost hydrogen production. We can use our manufacturing cost model to quantify potential cost reductions from the considerations described above and demonstrate pathways to lower cost electrolyzers. This allows for better understanding of cost reduction strategies and enables more informed research, development, and deployment for electrolyzers.

cost↗

Performance and long-term stability of CO 2 conversion to formic acid using a three-compartment electrolyzer design

The electrochemical reduction of CO 2 to formate and formic acid has attracted a great amount of academic and commercial interest over the past five years. A number of experimental studies have generated data on the Faradaic performance and stability of various candidate catalyst materials in producing formate or formic acid. However, most of the data has been conducted at low current densities and over short time periods, typically hours to days. There is a critical need in providing long-term catalyst stability as well as electrolyzer-based operating data, which are needed for the commercial scale-up and operation of this technology, especially at high current densities. In this paper, the electrochemical CO 2 conversion to pure formic acid was conducted using a three-compartment design electrolyzer, demonstrating electrolyzer catalyst and performance stability for over 1000 h at current densities up to 200 mA cm -2 . Depending on the operation conditions, the electrolyzer directly produced a 6.03 to 12.92 wt% (1.3 to 2.8 M) formic acid product at Faradaic efficiencies ranging between 73.0 to 91.3%. Data on electrolyzer performance, including formic acid product generation rate, energy efficiency, and energy consumption are reported at three different current densities, 100, 200, and 250 mA cm -2 . Finally, a long term 1000 h electrolyzer stability run at 200 mA cm -2 is presented, providing information on the operating conditions required in obtaining stable electrolyzer performance. All the data will be extremely useful in the commercial scale-up of this technology.

10 SYNTHETIC FUELS↗

A simple convertible electrolyzer in membraneless and membrane-based modes for understanding water splitting mechanism

State-of-the-art membrane-based electrolyzers such as proton exchange membrane electrolyzer cells, are costly, susceptible to degradation, and time-consuming for electrode evaluation and triple-phase boundary electrochemical reaction studies. Here, a simple convertible electrolyzer in membraneless and membrane-based modes is proposed. For the first time, this enables comprehensive investigations of water splitting with pure water, acidic and alkaline electrolytes in one cell. With the simple electrolyzer and high-speed visualization system, the influences of flow rate, electrolytes, concentration, and Nafion membrane on the oxygen evolution reactions (OERs), hydrogen evolution reactions (HERs) and electrolyzer performance are comprehensively investigated. Visualization results reveal that water splitting only occurred at the edge between the electrode and the Nafion membrane in pure water. However, they occurred on the whole electrode surface in alkaline and acidic electrolytes, indicating easily tunable reaction sites with the convertible electrolyzer. This demonstrates the feasibility of using the simple convertible electrolyzer for understanding the water splitting mechanism. The relation between electrolyte thickness and resistances with different electrolytes is also quantified. This research provides an insight for optimizing electrochemical devices while delivering an inexpensive and fast way for electrode evaluations and electrochemical reaction studies.

25 ENERGY STORAGE↗