Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electromagnetic pulse (EMP)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Literature Review of Electromagnetic Pulse (EMP) and Geomagnetic Disturbance (GMD) Effects on Oil and Gas Pipeline Systems

This document summarizes the findings of a review of published literature regarding the potential impacts of electromagnetic pulse (EMP) and geomagnetic disturbance (GMD) phenomena on oil and gas pipeline systems. The impacts of telluric currents on pipelines and their associated cathodic protection systems has been well studied. The existing literature describes implications for corrosion protection system design and monitoring to mitigate these impacts. Effects of an EMP on pipelines is not a thoroughly explored subject. Most directly related articles only present theoretical models and approaches rather than specific analyses and in-field testing. Literature on SCADA components and EMP is similarly sparse and the existing articles show a variety of impacts to control system components that range from upset and damage to no effect. The limited research and the range of observed impacts for the research that has been published suggests the need for additional work on GMD and EMP and natural gas SCADA components.

02 PETROLEUM↗

Effects of EMP Testing on Residential DC/AC Microinverters

Electromagnetic pulse (EMP) coupling into electronic devices can be destructive to components potentially causing device malfunction or failure. A large electromagnetic field generated from the EMP can induce large voltages and currents in components. As such, the effects of EMP on different devices needs to be understood to elucidate the effect of EMP on potentially vulnerable systems. This report presents test results for small-scale residential DC to AC solar panel microinverters that were subjected to high voltage impulses and currents. The impulses were intended to emulate an EMP coupling event to the AC and DC sides of the microinverter. State-of-health measurements were conducted to characterize device performance before and after each test.

42 ENGINEERING↗

Immunity Study: Port Impedance Measurement of PMU and PCI testing under EMP

With the increased requirements of real-time grid monitoring, disturbance location, and situation awareness, Phasor Measurement Units (PMUs) have become more critical for the Wide Area Measurement System (WAMS). However, the vulnerability of PMUs has not been well studied, especially under electromagnetic pulse (EMP) scenarios. The stable operation of the power system will be affected directly once EMP damages them. Therefore, studying their immunity to EMP events is urgent and necessary. In this paper, the effective impedance measurement scheme and pulsed current injection (PCI) testing are proposed for the port impedance measurement and immunity levels of PMUs. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then, the circuit of the pulsed current generator is set to generate a damping sinusoid, and the double exponential wave is applied to the port. Finally, using measured impedance as a generator load, the voltage and current responses of different ports are calculated in the PCI testing simulation. In conclusion, results reveal the characteristics of port impedance, waveforms of voltage and current, and distribution of accumulative energy. The relation between port impedance and the waveforms is discussed.

42 ENGINEERING↗

Modeling, testing, and mitigation of electromagnetic pulse on PV systems

Electromagnetic Pulse (EMP) poses a significant threat to the normal operation of power systems, especially with the increasing penetration of renewable energy. Without adequate protection, EMP can severely damage equipment or result in circuit breakdowns or short circuits. Solar photovoltaic (PV) facilities are particularly susceptible to EMP since PV systems are outdoors and exposed to EMP radiation. To assess and mitigate this threat, this paper summarizes various models and tests used to study the effects of EMP on PV systems, assesses the nature of the threat, and identifies measures to mitigate it. The paper provides a comprehensive review by categorizing analytical methods based on their pros and cons, introducing and describing EMP-related events, and providing a taxonomy of analytical methods for studying EMP. This paper compares the processes of modeling, testing, and mitigating EMP at both the component and system levels of PV systems. Furthermore, it also presents a case study that reveals the vulnerability of solar inverters to EMP using the pulse current injection method. Finally, the paper discusses some of the remaining challenges that should be considered in future solar PV system design and deployment.

14 SOLAR ENERGY↗

Lightning driven EMP in the upper atmosphere

Large lightning discharges can drive electromagnetic pulses (EMP) that cause breakdown of the neutral atmosphere between 80 and 95 km leading to order of magnitude increases in the plasma density. The increase in the plasma density leads to increased reflection and absorption, and limits the pulse strength that propagates higher into the ionosphere.

Rowland, H. L.↗

Impact Analysis of High-Altitude Electromagnetic Pulse Coupling Effects on Power Grid Protection Relays

Protection relays are important equipment used for protection, control, and metering functions in the power grid. These relays are used to protect critical and difficult-to-replace equipment, like generators, transformers, and capacitor banks. Once the protection devices are disturbed or damaged, a high risk of power generation interruption occurs. Therefore, it is important and necessary to study the relay’s immunity to electromagnetic pulse (EMP) events. As a preliminary step toward empirical experimentation on actual equipment, this manuscript outlines an economical and efficient methodology for evaluating the impact of an EMP. An impedance measurement strategy was employed to model the equipment, setting the stage for subsequent immunity analyses. These analyses included the pulse current injection (PCI) method, which utilized an injecting probe to introduce the transient, and frequency domain electromagnetic (FEKO) simulation, which integrated electromagnetic coupling effects into the transient simulation. The impedance measurement and simulation results in this paper provide a reliable basis for gauging equipment performance in the face of HEMP threats. The results obtained using the PCI and FEKO simulations demonstrated the performance of different port responses under a high-altitude EMP, indicating the requirement for some protection to ensure the reliable operation of relays.

42 ENGINEERING↗

EMP-Resilient Electric Grid Transformer Analysis

The response of a high - voltage (HV) transformer to fast rise time voltages, such as that from a electromagnetic pulse (EMP) can result in interruption of power distribution and possibly system failure. To help identify these potential occurrences, it is necessary to develop a transformer model that not only captures the input/output response of the transformer but also the internal behavior. The model constructed should cover the frequency band of interest while capturing the internal physical and electrical characteristics. This broad-band, high-fidelity model would enable the prediction of unwanted effects through simulation. A proposed modeling scheme for a HV transformer is described in Part 1 of this report. Part 2 of this report details assessments of internal voltage and electrical field holdoff testing of transformer insulation dielectric breakdown, including comparison of low frequency (DC/60 Hz) holdoff to rise times characteristic of lightning (1 s) and EMP E1 transients (10 - 30 ns). This initial project is a path toward establishing electrical grid transformer failure criteria for EMP voltage transients. We developed modeling methods and measured breakdown electrical field statistical distributions for direct current, 60 Hz, lightning and EMP characteristic voltage rise times. Methods of nanosecond-scale capacitive discharge unit high voltage source development, suggestions for derating of 60 Hz insulation maximum electrical fields for EMP nanosecond pulse voltage withstand rating, and potential methods for increasing transformer resilience to such fast rise time pulses are described.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spatial decay of electromagnetic waves from hypervelocity impact plasmas

Due to the high kinetic energy of impactors in space, hypervelocity impacts on spacecraft can ablate spacecraft material and produce plasmas. These plasmas have been observed in ground-based experiments to produce electromagnetic pulses (EMPs) and are suspected to be a cause of spacecraft anomalies. The initial EMP that is produced after plasma formation is replicated using a 2D electromagnetic plasma simulation, consisting of a discontinuous Galerkin, particle-in-cell (DG-PIC) framework. The spontaneous formation of EMPs from an initial quasineutral plasma is consistent with previous works and show behavior similar to that of waves emitted by antennas. The EMP emits from the plasma with a frequency less than the plasma frequency associated with the point of maximum density, showing the importance of the density gradient, and the far-field region of the “plasma antenna” is estimated. From the proportionality between plasma frequency and EMP frequency, there is a direct correlation between plasma density and radiation. Finally, as the plasma density decreases, the EMP frequency decreases, which suggests that several observable phenomena, such as optical flashes, radio frequency emission, and microwave emission, all result from the same plasma-related mechanism within a single hypervelocity impact.

42 ENGINEERING↗

Assessing the vulnerability of solar inverters to EMPs: Port testing, PCI modeling, and protection strategies

Renewable energy sources are becoming an ever-larger contributor to the power grid. These renewable energy sources depend upon the power electronic devices, specifically inverters, being essential for connecting Photovoltaic (PV) generation to the grid. However, the Electromagnetic Pulses (EMPs) caused by the high-altitude nuclear explosions can generate fast broad-band pulses with nanosecond rise time, potentially causing damage or destruction to electronic components. To assess the vulnerability of PV inverters to high-altitude EMPs, the port testing and Pulsed Current Injection (PCI) modeling schemes are proposed based on the port impedance analysis. Wide-band frequency measurements are achieved by fusing impedance results from three vector network analyzers. Then, a PCI model is used to simulate the induced response to EMP, with two typical immunity levels of EC5 and EC8 tested. Here, the experiment successfully excites the induced voltage and current under EMP, where the voltage and current can reach 1500V/40A and 8000V/150Aunder EC5 andEC8, respectively. The port vulnerability analysis results demonstrate that only some ports can survive under EC5. To defend against the impact of EMP, three protection strategies are discussed.

42 ENGINEERING↗

20 kV Gallium Nitride pn Diode Electro-Magnetic Pulse Arrestor for Grid Reliability (Final Scientific/Technical Report)

This project developed vertical Gallium Nitride (GaN) pn diodes under two main thrusts: (1) A focus on relatively higher-voltage devices for use as fast EMP arrestors to protect the electric grid; and (2) A focus on a Foundry effort to establish the manufacturability of relatively lower voltage devices. For the first thrust, the aim was to develop devices that go into avalanche breakdown to clamp the voltage across sensitive grid equipment subject to voltage transients induced by electromagnetic pulses (EMPs). Devices with breakdown voltages exceeding 6.5 kV were achieved, and breakdown times shorter than 1 ns were demonstrated, which is sufficiently fast to protect against the fast component of an EMP-induced signal. Key challenges included the epitaxial growth of thick (50 µm or more), low-doped (low 10 15 cm -3 range) GaN layers comprising the drift regions of the diodes, as well as the design and fabrication of edge termination structures (step-etched junction termination extensions) to prevent premature breakdown. Midway through the project, an additional emphasis was put on large-area, high-current devices, and forward currents of approximately 400 A were achieved in composite devices towards the end of the project. Experimental and theoretical studies of impact ionization and avalanche ruggedness were also conducted. For the second thrust (the Foundry), the focus was primarily on 1.2-kV-class devices, although towards the end of the project outstanding results on 3.3-kV class devices were also achieved. The aim of the Foundry was to develop a high-yield, reliable, and economic vertical GaN pn diode process. The Foundry conducted characterization of incoming epitaxial material and correlated this information with the yield and performance of fully processed devices. Wafer maps of diode characteristics such as forward and reverse current as well as capacitance-voltage curves were measured using auto-probing. Several mask sets comprising different-area devices as well as multiple edge termination designs (implanted junction termination extensions, guard rings, and combinations thereof) were studied, and machine-learning-based approaches were utilized to analyze the data. Packaging and reliability efforts were also undertaken for the Foundry diodes, which are necessary for a viable commercial process.

20KV↗

20 kV Gallium Nitride pn Diode Electro-Magnetic Pulse Arrestor for Grid Reliability (Final Report)

This project developed vertical Gallium Nitride (GaN) pn diodes under two main thrusts: (1) A focus on relatively higher-voltage devices for use as fast EMP arrestors to protect the electric grid; and (2) A focus on a Foundry effort to establish the manufacturability of relatively lower-voltage devices. For the first thrust, the aim was to develop devices that go into avalanche breakdown to clamp the voltage across sensitive grid equipment subject to voltage transients induced by electromagnetic pulses (EMPs). Devices with breakdown voltages exceeding 6.5 kV were achieved, and breakdown times shorter than 1 ns were demonstrated, which is sufficiently fast to protect against the fast component of an EMP-induced signal. Key challenges included the epitaxial growth of thick (50 um or more), low-doped (low 10 15 cm -3 range) GaN layers comprising the drift regions of the diodes, as well as the design and fabrication of edge termination structures (step-etched junction termination extensions) to prevent premature breakdown. Midway through the project, an additional emphasis was put on large-area, high-current devices, and forward currents of approximately 400 A were achieved in composite devices towards the end of the project. Experimental and theoretical studies of impact ionization and avalanche ruggedness were also conducted. For the second thrust (the Foundry), the focus was primarily on 1.2-kV-class devices, although towards the end of the project outstanding results on 3.3-kV-class devices were also achieved. The aim of the Foundry was to develop a high-yield, reliable, and economic vertical GaN pn diode process. The Foundry conducted characterization of incoming epitaxial material and correlated this information with the yield and performance of fully processed devices. Wafer maps of diode characteristics such as forward and reverse current as well as capacitance-voltage curves were measured using auto-probing. Several mask sets comprising different-area devices as well as multiple edge termination designs (implanted junction termination extensions, guard rings, and combinations thereof) were studied, and machine-learning-based approaches were utilized to analyze the data. Packaging and reliability efforts were also undertaken for the Foundry diodes, which are necessary for a viable commercial process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Vulnerability Studies Under EMP: Impedance and PCI Testing of the Grid Control Devices

Control devices such as inverters and generator controllers are critical for the stable operation of the power grid, especially for power stability control and power dispatch. However, the Electromagnetic Pulse (EMP) is a potential threat to electronic devices in modern power grids, therefore decreasing the power grid resilience and bringing unrecoverable damages to the devices. To reveal the impact mechanism of the EMP, impedance and Pulse Current Injection (PCI) testing is established to study the vulnerability of the grid control devices. The impedance of the grid control devices is accurately measured using impedance analyzers with different frequency ranges. Then the voltage and current responses are tested based on the PCI testing. The vulnerability experiments based on two grid control devices are carried out. And the comparison results reveal that most ports would be damaged under EC8, and some ports can survive under EC5 according to the calculated PCI response and cumulative energy. The results can provide a reference for the future design of control devices and the strategic resilience of power grids.

Qiu, Wei↗

Immunity Study: Port Impedance Measurement of PMU and PCI testing under EMP

Phasor Measurement Units (PMUs) are critical for the Wide Area Measurement System (WAMS), especially for real-time grid monitoring, disturbance location, and situation awareness. Once they are damaged, the stable operation of the power system will be affected directly and greatly. Therefore, it is urgent and necessary to study their immunity to electromagnetic pulse (EMP) events. In this paper, an effective impedance measurement scheme is proposed for port impedance measurement of PMU. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then circuit of pulsed current generator is established to generate damping sinusoid and double exponential wave applied to the port. Finally, by using measured impedance as a load of the generator, the voltage and current responses of different ports are calculated in the pulsed current injection (PCI) testing simulation. Results show that common-mode impedance is large and differential mode impedance is small. The critical condition will appear in the common mode for voltage and differential mode for current.

Zhang, Liang↗

Generation and regulation of electromagnetic pulses induced by hybrid laser pulses interacting with solid targets

In inertial confinement fusion, electromagnetic pulses (EMPs) can be produced during high-power laser interacting with solid targets, which are intimately related to laser intensity and laser energy. In this study, EMPs generated by hybrid laser pulses coupling with targets are recorded and analyzed. The results indicate that a single picosecond laser gives birth to the most intense EMPs, but they are remarkably suppressed when a nanosecond laser-shooting target is triggered before the picosecond and femtosecond laser. One possible hypothesis is proposed based on x-rays inducing pre-ablation that generates pre-plasma at the surfaces of the picosecond target and femtosecond target, leading to a sharp drop both in the energy and number of the emitting hot electrons and protons. Here, the findings will deepen our understanding of the mechanism of EMPs' generation and will also open a new avenue to regulate EMPs by hybrid laser pulses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects on Structure’s Electromagnetic Shielding Effectiveness Considering Penetrating Cables Coupling Energy from HEMP Event

The threat of weaponized electromagnetic pulse (EMP) is a serious factor in defining power system resilience. Without adequate knowledge regarding the interaction between EMP and power system infrastructure, system personnel may be unable to plan for and operate during an EMP event and major blackouts could occur. This work studies the interaction between EMP and structures, specifically analyzing the shielding effectiveness of buildings emulating power generation facilities. The main focus is to determine how penetrating cables affect the structure’s shielding effectiveness. Several cable parameters including height above ground, radius, termination configuration, and length are analyzed via computational electromagnetic simulations. Results demonstrated penetrating cables can significantly diminish a structure’s shielding effectiveness, especially the electric field. Length of cable is the most influential parameter.

Mignardot, David↗

Suppression and enhancement of electromagnetic pulses from laser–target interactions by strong magnetic fields

Laser–target interactions generate intense electromagnetic pulses (EMPs) that can interfere with measurements and damage equipment. In this paper we show that applying a magnetic field to nanosecond pulse laser–target interactions decreases the magnitude of EMPs. We demonstrate this effect in two experiments with different geometries (spherical versus planar), laser intensities ( ∼10 13 versus ∼10 15 W/cm 2 ) and applied field strength (12 versus 0.1 T) that both observed suppression of EMPs in approximately the 1 GHz band (by factors of 0.65× and 0.32×, respectively). We then observe the opposite effect at high intensities with a picosecond pulse: for planar experiments with laser intensities of approximately 10 19 W/cm 2 and magnetic fields of 6–10 T, the magnitude of EMPs is increased by a factor of 1.75×. These results provide a benchmark for models of EMP generation, but suggest that magnetic fields are not a viable solution for mitigating EMPs in the high-intensity laser facilities where they are most damaging.

electromagnetic pulse↗

Particle‐In‐Cell Simulations of Starfish Prime

The Starfish Prime high altitude nuclear test created a transient diamagnetic cavity in the Earth's magnetic field above Johnston Island and launched an electromagnetic pulse (EMP) that was detected around the globe. For this work, we use the ion‐kinetic particle‐in‐cell code Topanga to simulate diamagnetic cavity evolution and the E3 EMP signal for Starfish Prime out to over a minute of physical time. The simulation domain has a longitudinal and latitudinal extent of 60° X 60° and a vertical extent of 2,000 km from the surface of the Earth. We compare our simulated results to magnetometer measurements taken in space and on the ground, finding good agreement in both cases. The diamagnetic cavity in the simulation forms in about a second, while the associated debris flux tube takes approximately 30 s to decay. The debris flux tube undergoes significant motion during this timeframe, rising upward. The measured E3 EMP signal on the ground consists of several components, all of which are present in our simulations. We discuss the physical origin of these components in relation to E3a (blast) and E3b (heave).

Belyaev, Mikhail A. [Lawrence Livermore National L↗