Crystallographic analysis in the Scanning electron microscope: Electron backscatter diffraction.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Electron sources were made from individual multi-walled carbon nanotubes with closed caps and thoroughly cleaned surfaces. Nanotubes from both chemical vapor deposition growth and arc discharge growth were investigated. These emitters provide a highly stable emission current up to a threshold current of a few microamperes. At too large currents several processes take place such as splitting, breaking and cap closing. The emission process is field emission for a workfunction of 5 eV. The electron optical per-formance is highly beneficial for their use as high-brightness point sources in electron microscopes and advantageous with respect to state-of-the-art electron sources. The life-time is at least two years. We have tested the source successfully in a scanning electron microscope.
Electron transport variations in individual ZnS nanowires synthesized through a chemical vapor deposition process were in situ studied in transmission electron microscope under convergent electron-beam irradiation (EBI). It was found that the transport can dramatically be enhanced using proper irradiation conditions. The conductivity mechanism was revealed based on a detailed study of microstructure and composition evolutions under irradiation. EBI-induced Zn-rich domains' appearance and related O doping were mainly responsible for the conductivity improvements. First-principles theoretical calculations additionally indicated that the generation of midbands within a ZnS band gap might also contribute to the improved conductivity.
Not Available
Abstract not provided.
The ability of electron microscopes to analyze all the atoms in individual nanostructures is limited by lens aberrations. However, recent advances in aberration-correcting electron optics have led to greatly enhanced instrument performance and new techniques of electron microscopy. The development of an ultrastable electron microscope with aberration-correcting optics and a monochromated high-brightness source has significantly improved instrument resolution and contrast. In the present work, we report information transfer beyond 50 pm and show images of single gold atoms with a signal-to-noise ratio as large as 10. The instrument's new capabilities were exploited to detect a buried {Sigma}3 {l_brace}112{r_brace} grain boundary and observe the dynamic arrangements of single atoms and atom pairs with sub-angstrom resolution. These results mark an important step toward meeting the challenge of determining the three-dimensional atomic-scale structure of nanomaterials.
Laser delivery probes using multimode fiber optic delivery and bulk focusing optics have been constructed and used for performing materials processing experiments within scanning electron microscope/focused ion beam instruments. Controlling the current driving a 915-nm semiconductor diode laser module enables continuous or pulsed operation down to sub-microsecond durations, and with spot sizes on the order of 50 {mu}m diameter, achieving irradiances at a sample surface exceeding 1 MW/cm{sup 2}. Localized laser heating has been used to demonstrate laser chemical vapor deposition of Pt, surface melting of silicon, enhanced purity, and resistivity via laser annealing of Au deposits formed by electron beam induced deposition, and in situ secondary electron imaging of laser induced dewetting of Au metal films on SiO{sub x}.
Not Available
A new experimental framework for the characterization of defects in semiconductors is demonstrated. Through the direct, energy-resolved correlation of three analytical techniques spanning six orders of magnitude in spatial resolution, a critical mid-bandgap electronic trap level (E V + 0.56 eV) within Ag 0.2 Cu 0.8 In 1–x Ga x Se 2 is traced to its nanoscale physical location and chemical source. This is achieved through a stepwise, site-specific correlated characterization workflow consisting of device-scale (≈1 mm 2 ) deep level transient spectroscopy (DLTS) to survey the traps present, scanning probe–based DLTS (scanning-DLTS) for mesoscale-resolved (hundreds of nanometers) mapping of the target trap state’s spatial distribution, and scanning transmission electron microscope based electron energy-loss spectroscopy (STEM-EELS) and X-ray energy-dispersive spectroscopy for nanoscale energy-, structure, and chemical-resolved investigation of the defect source. Furthermore, this first demonstration of the direct observation of sub-bandgap defect levels via STEM-EELS, combined with the DLTS methods, provides strong evidence that the longsuspected Cu In/Ga substitutional defects are indeed the most likely source of the E V + 0.56 eV trap state and serves as a key example of this approach for the fundamental identification of defects within semiconductors, in general.
An electron optical system for observing Foucault images was constructed using a conventional transmission electron microscope without any special equipment for Lorentz microscopy. The objective lens was switched off and an electron beam was converged by a condenser optical system to the crossover on the selected area aperture plane. The selected area aperture was used as an objective aperture to select the deflected beam for Foucault mode, and the successive image-forming lenses were controlled for observation of the specimen images. The irradiation area on the specimen was controlled by selecting the appropriate diameter of the condenser aperture.
Mirror electron microscope (MEM) observation has been conducted for a 4-{mu}m-thick n-doped 4H-SiC epitaxial layer. If the sample is simultaneously illuminated with ultraviolet (UV) light of a slightly greater energy than the bandgap energy of 4H-SiC, in-grown stacking faults (IGSFs) can be clearly observed in MEM images. These observations were performed non-destructively, as almost all irradiated electrons returned without impinging the sample surface due to the negative voltage applied to the sample. High spatial resolution observation via MEM showed that multiple IGSFs were stacked up. The phenomenon in which the contrast of the IGSFs vanished in the absence of UV illumination and under UV illumination with a lower energy than the bandgap energy revealed that the origin of the contrast was the negative charging of IGSFs trapping electrons excited by UV light.
Electron microscopy and defect analysis are a cornerstone of materials science, as they offer detailed insights on the microstructure and performance of a wide range of materials and material systems. Building a robust and flexible platform for automated defect recognition and classification in electron microscopy will result in the completion of analysis orders of magnitude faster after images are recorded, or even online during image acquisition. Automated analysis has the potential to be significantly more efficient, accurate, and repeatable than human analysis, and it can scale with the increasingly important methods of automated data generation. Herein, an automated recognition tool is developed based on a computer vison–based approach; it sequentially applies a cascade object detector, convolutional neural network, and local image analysis methods. We demonstrate that the automated tool performs as well as or better than manual human detection in terms of recall and precision and achieves quantitative image/defect analysis metrics close to the human average. The proposed approach works for images of varying contrast, brightness, and magnification. Furthermore, these promising results suggest that this and similar approaches are worth exploring for detecting multiple defect types and have the potential to locate, classify, and measure quantitative features for a range of defect types, materials, and electron microscopic techniques.
Explore the source record for details and available documents.
Here, this article describes the establishment, over a period of 10 years or so, of a multi-user, institution-wide facility for the characterization of materials and devices at the nanoscale. Emphasis is placed on the type of equipment that we have found to be most useful for our users, and the business strategy that maintains its operations. A central component of our facility is an aberration-corrected environmental transmission electron microscope and its application is summarized in the studies of plasmon energies of silver nanoparticles, the band gap of PbS quantum dots, atomic site occupancy near grain boundaries in yttria stabilized zirconia, the lithiation of silicon nanoparticles, in situ observations on carbon nanotube oxidation and the electron tomography of varicella zoster virus nucleocapsids.
In-situ tensile tests have been performed in a dual beam focused ion beam and scanning electron microscope on as-grown and prestrained single-crystal molybdenum-alloy (Mo-alloy) fibers. The fibers had approximately square cross sections with submicron edge lengths and gauge lengths in the range of 9–41 μm. In contrast to previously observed yield strengths near the theoretical strength of 10 GPa in compression tests of ~1–3-μm long pillars made from similar Mo-alloy single crystals, a wide scatter of yield strengths between 1 and 10 GPa was observed in the as-grown fibers tested in tension. Deformation was dominated by inhomogeneous plastic events, sometimes including the formation of Lüders bands. In contrast, highly prestrained fibers exhibited stable plastic flow, significantly lower yield strengths of ~1 GPa, and stress–strain behavior very similar to that in compression. A simple, statistical model incorporating the measured dislocation densities is developed to explain why the tension and compression results for the as-grown fibers are different.
The scanning electron microscope is becoming a popular tool to perform tasks that require positioning, manipulation, characterization, and assembly of micro-components. However, some of these applications require a higher level of performance with respect to dynamics and precision of positioning. One limiting factor is the presence of unidentified noises and disturbances. This work aims to study the influence of mechanical disturbances generated by the environment and by the microscope, identifying how these can affect elements in the vacuum chamber. To achieve this objective, a dedicated setup, including a high-resolution vibrometer, was built inside the microscope. This work led to the identification and quantification of main disturbances and noise sources acting on a scanning electron microscope. Furthermore, the effects of external acoustic excitations were analysed. Potential applications of these results include noise compensation and real-time control for high accuracy tasks.
In-situ (scanning) transmission electron microscopy (S/TEM) is being developed for numerous applications in the study of nucleation and growth under electrochemical driving forces. For this type of experiment, one of the key parameters is to identify when nucleation initiates. Typically the process of identifying the moment that crystals begin to form is a manual process requiring the user to perform an observation and respond accordingly (adjust focus, magnification, translate the stage etc.). However, as the speed of the cameras being used to perform these observations increases, the ability of a user to “catch” the important initial stage of nucleation decreases (there is more information that is available in the first few milliseconds of the process). Here we show that video shot boundary detection (SBD) can automatically detect frames where a change in the image occurs. We show that this method can be applied to quickly and accurately identify points of change during crystal growth. This technique allows for automated segmentation of a digital stream for further analysis and the assignment of arbitrary time stamps for the initiation of processes that are independent of the user’s ability to observe and react.