Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrostatic voltmeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Voltage mapping and local defects identification in solar cells using non-contact method

Electroluminescence, infrared imaging, and current–voltage curve techniques are used to detect and map underperforming cells in a photovoltaic module or the modules in a photovoltaic string. In this work, we present a non-contact electrostatic voltmeter technique to detect and map the underperforming spots in a cell and the cells in a module. This non-contact technique directly maps the charged surface voltage (671mV) of the superstrate glass, and it had an 11-mV difference with the voltmeter values (660mV). Another data set of voltage values obtained by electroluminescence images conversion into a voltage map showed a difference of 7mV with the non-contact voltmeter values. Further, the direct voltage values obtained at various good and poor-performing spots of the cells using this technique are 3.69V and 3.79V and are validated using the voltage values obtained in electroluminescence analysis and the difference in voltage obtained by the two techniques is determined to be less than 2%. In this work, we combine the strengths of two complementary techniques of the electrostatic voltmeter (strength: quantitative) and electroluminescence (strength: spatial mapping) to obtain a quantitative spatial mapping of defects. Furthermore, this work is extendable to detect the poor-performing modules in solar PV power plants.

14 SOLAR ENERGY↗

Use of non-contact voltmeter to quantify potential induced degradation in CdTe modules

Potential induced degradation (PID) is a significant reliability issue for photovoltaic modules in the field. Conventionally, to detect the PID-affected modules, all the modules in a string are individually disconnected and measured using I-V (current–voltage) tracers. It is extremely time-consuming, expensive and unsafe (if the module connectors are field aged) approach. In our approach, we aim detecting the PID-affected modules quickly, inexpensively and safely without disconnecting individual modules in the string. In this study, contactless electrostatic voltmeter’s (ESV) strength was explored to detect the PID-affected cadmium telluride (CdTe) modules in a string. These contactless measurements on high-voltage PV strings could make this technique unique and preferable to detect PID-affected modules in a string compared to the I-V curve method. In this work, a CdTe module was stressed for PID using the Aluminum (Al) foil method in a walk-in environmental chamber, which resulted in a reduction of module's peak current (I max ), peak voltage (Vmax), and fill factor (FF), and hence power (Pmax). Outdoor light I-V, EL, and ESV measurements were performed pre- and post-PID to determine the effectiveness of the non-contact ESV technique. Further, the ESV technique successfully detected the change in V max , and hence Pmax, compared to the pre-and post-PID conditions. A difference of less than 2% was observed in the results of the non-contact and non-interruptive method compared to the conventionally used interruptive voltmeter or I-V tracer method. This technique and the test results demonstrate a significant promise to identify poor-performing modules in PV string without disconnection of individual modules in the string.

14 SOLAR ENERGY↗

Charge Deposition/Neutralization and Dust Removal via Plasma Interactions

Electrically charged and chemically reactive lunar dust can cause serious problems to spacecraft, surface equipment, and astronaut health, so understanding its interaction with and transport through the lunar plasma environment is important to dust mitigation efforts. We explore the charging of granular material in the natural environment of the Moon, recreate those conditions in the laboratory under high vacuum, and examine dust transport and charge neutralization for application in future lunar missions. Phenomena such as charge deposition via electron and ion beams, photoionization through ultraviolet light exposure, neutralization of charge through impingement by an ionized compressed gas, and tribocharging during dust liberation from surfaces will be presented. Surface materials of interest such as floating/grounded conductors and orthofabric for spacesuits are the preliminary focus of this effort. An electrometer is used to characterize currents interacting with the surfaces in the case of the electron/ion/UV source exposure, an electrostatic voltmeter is used to measure the potential on the surfaces without inadvertently discharging them, and a charge plate monitor is used to verify the efficiency of discharging the surfaces via ionized gas impingement. After setup of the initial charge conditions on the surfaces, a quick burst of high-pressure gas is used to overcome adhesion forces and initially dislodge the dust from the surfaces, followed by a low flow of gas that is ionized via application of a strong electric field. The gas is released in a high vacuum environment so as the pressure drops from the initial compressed state through to the vacuum state, the mean free path reaches a point where ionization can occur before all the gas disperses into the vacuum. This ionized gas can then neutralize both the dust and the surface to ensure minimal resettling. Several parameters such as gas composition, electrode geometry, high voltage waveform shape/polarity, and pulse timing have been explored and will be presented here.

electrostatics↗

Amplitude-Stabilized Oscillator for a Capacitance-Probe Electrometer

A multichannel electrometer voltmeter that employs a mechanical resonator maintained in sustained amplitude-stabilized oscillation has been developed for the space-based measurement of an Internal Electrostatic Discharge Monitor (IESDM) sensor. The IESDM is new sensor technology targeted for integration into a Space Environmental Monitor (SEM) subsystem used for the characterization and monitoring of deep dielectric charging on spacecraft. Creating a stable oscillator from the mechanical resonator was achieved by employing magnetic induction for sensing the resonator s velocity, and forcing a current through a coil embedded in the resonator to produce a Lorentz actuation force that overcomes the resonator s dissipative losses. Control electronics employing an AGC loop provide conditions for stabilized, constant amplitude harmonic oscillation. The prototype resonator was composed of insulating FR4 printed-wireboard (PWB) material containing a flat, embedded, rectangular coil connected through flexure springs to a base PWB, and immersed in a magnetic field having two regions of opposite field direction generated by four neodymium block magnets. In addition to maintaining the mechanical movement needed for the electrometer s capacitor-probe transducer, this oscillator provides a reference signal for synchronous detection of the capacitor probe s output signal current so drift of oscillation frequency due to environmental effects is inconsequential.

Blaes, Brent R.↗

Capacitance Probe Resonator for Multichannel Electrometer

A multichannel electrometer voltmeter has been developed that employs a mechanical resonator with voltage-sensing capacitance-probe electrodes that enable high-impedance, high-voltage, radiation-hardened measurement of an Internal Electrostatic Discharge Monitor (IESDM) sensor. The IESDM is new sensor technology targeted for integration into a Space Environmental Monitor (SEM) subsystem used for the characterization and monitoring of deep dielectric charging on spacecraft. The resonator solution relies on a non-contact, voltage-sensing, sinusoidal-varying capacitor to achieve input impedances as high as 10 petaohms as determined by the resonator materials, geometries, cleanliness, and construction. The resonator is designed with one dominant mechanical degree of freedom, so it resonates as a simple harmonic oscillator and because of the linearity of the variable sense capacitor to displacement, generates a pure sinusoidal current signal for a fixed input voltage under measurement. This enables the use of an idealized phase-lock sensing scheme for optimal signal detection in the presence of noise.

Blaes, Brent R.↗

Self-Nulling Lock-in Detection Electronics for Capacitance Probe Electrometer

A multi-channel electrometer voltmeter that employs self-nulling lock-in detection electronics in conjunction with a mechanical resonator with noncontact voltage sensing electrodes has been developed for space-based measurement of an Internal Electrostatic Discharge Monitor (IESDM). The IESDM is new sensor technology targeted for integration into a Space Environmental Monitor (SEM) subsystem used for the characterization and monitoring of deep dielectric charging on spacecraft. Use of an AC-coupled lock-in amplifier with closed-loop sense-signal nulling via generation of an active guard-driving feedback voltage provides the resolution, accuracy, linearity and stability needed for long-term space-based measurement of the IESDM. This implementation relies on adjusting the feedback voltage to drive the sense current received from the resonator s variable-capacitance-probe voltage transducer to approximately zero, as limited by the signal-to-noise performance of the loop electronics. The magnitude of the sense current is proportional to the difference between the input voltage being measured and the feedback voltage, which matches the input voltage when the sense current is zero. High signal-to-noise-ratio (SNR) is achieved by synchronous detection of the sense signal using the correlated reference signal derived from the oscillator circuit that drives the mechanical resonator. The magnitude of the feedback voltage, while the loop is in a settled state with essentially zero sense current, is an accurate estimate of the input voltage being measured. This technique has many beneficial attributes including immunity to drift, high linearity, high SNR from synchronous detection of a single-frequency carrier selected to avoid potentially noisy 1/f low-frequency spectrum of the signal-chain electronics, and high accuracy provided through the benefits of a driven shield encasing the capacitance- probe transducer and guarded input triaxial lead-in. Measurements obtained from a 2- channel prototype electrometer have demonstrated good accuracy (|error| < 0.2 V) and high stability. Twenty-four-hour tests have been performed with virtually no drift. Additionally, 5,500 repeated one-second measurements of 100 V input were shown to be approximately normally distributed with a standard deviation of 140 mV.

Blaes, Brent R.↗

Measuring Electrostatic Discharge

Apparatus measures electrostatic-discharge properties of several materials at once. Allows samples charged either by friction or by exposure to corona. By testing several samples simultaneously, apparatus eliminates errors introduced by variations among test conditions. Samples spaced so they pass at intervals under either of two retractable arms. Samples are 2 inches wide along circular path. Arm tips and voltmeter probe are 6 inches from turntable center. Servocontrolled turntable speed constant within 0.1 percent.

Smith, William C.↗