Search NASA⌕ Search

SEARCH · Search NASA

Results for “Emission Tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Accuracy of Tau Positron Emission Tomography as a Prognostic Marker in Preclinical and Prodromal Alzheimer Disease: A Head-to-Head Comparison Against Amyloid Positron Emission Tomography and Magnetic Resonance Imaging

Importance: Tau positron emission tomography (PET) tracers have proven useful for the differential diagnosis of dementia, but their utility for predicting cognitive change is unclear. Objective: To examine the prognostic accuracy of baseline fluorine 18 ( 18 F)-flortaucipir and [18F]RO948 (tau) PET in individuals across the Alzheimer disease (AD) clinical spectrum and to perform a head-to-head comparison against established magnetic resonance imaging (MRI) and amyloid PET markers. Design, setting, and participants: This prognostic study collected data from 8 cohorts in South Korea, Sweden, and the US from June 1, 2014, to February 28, 2021, with a mean (SD) follow-up of 1.9 (0.8) years. A total of 1431 participants were recruited from memory clinics, clinical trials, or cohort studies; 673 were cognitively unimpaired (CU group; 253 [37.6%] positive for amyloid-β [Aβ]), 443 had mild cognitive impairment (MCI group; 271 [61.2%] positive for Aβ), and 315 had a clinical diagnosis of AD dementia (315 [100%] positive for Aβ). Exposures: [ 18 F]Flortaucipir PET in the discovery cohort (n = 1135) or [ 18 F]RO948 PET in the replication cohort (n = 296), T1-weighted MRI (n = 1431), and amyloid PET (n = 1329) at baseline and repeated Mini-Mental State Examination (MMSE) evaluation. Main outcomes and measures: Baseline [ 18 F]flortaucipir/[ 18 F]RO948 PET retention within a temporal region of interest, MRI-based AD-signature cortical thickness, and amyloid PET Centiloids were used to predict changes in MMSE using linear mixed-effects models adjusted for age, sex, education, and cohort. Mediation/interaction analyses tested whether associations between baseline tau PET and cognitive change were mediated by baseline MRI measures and whether age, sex, and APOE genotype modified these associations. Results: Among 1431 participants, the mean (SD) age was 71.2 (8.8) years; 751 (52.5%) were male. Findings for [ 18 F]flortaucipir PET predicted longitudinal changes in MMSE, and effect sizes were stronger than for AD-signature cortical thickness and amyloid PET across all participants (R 2 , 0.35 [tau PET] vs 0.24 [MRI] vs 0.17 [amyloid PET]; P < .001, bootstrapped for difference) in the Aβ-positive MCI group (R2, 0.25 [tau PET] vs 0.15 [MRI] vs 0.07 [amyloid PET]; P < .001, bootstrapped for difference) and in the Aβ-positive CU group (R 2 , 0.16 [tau PET] vs 0.08 [MRI] vs 0.08 [amyloid PET]; P < .001, bootstrapped for difference). These findings were replicated in the [ 18 F]RO948 PET cohort. MRI mediated the association between [ 18 F]flortaucipir PET and MMSE in the groups with AD dementia (33.4% [95% CI, 15.5%-60.0%] of the total effect) and Aβ-positive MCI (13.6% [95% CI, 0.0%-28.0%] of the total effect), but not the Aβ-positive CU group (3.7% [95% CI, -17.5% to 39.0%]; P = .71). Age (t = -2.28; P = .02), but not sex (t = 0.92; P = .36) or APOE genotype (t = 1.06; P = .29) modified the association between baseline [ 18 F]flortaucipir PET and cognitive change, such that older individuals showed faster cognitive decline at similar tau PET levels. Conclusions and relevance: The findings of this prognostic study suggest that tau PET is a promising tool for predicting cognitive change that is superior to amyloid PET and MRI and may support the prognostic process in preclinical and prodromal stages of AD.

59 BASIC BIOLOGICAL SCIENCES↗

Systems and methods for point-of-care positron emission tomography

A positron emission tomography (PET) system is provided. The system includes a first detector panel including a first array of detectors, a second detector panel including a second array of detectors, said second detector panel being moveable relative to a point between the first detector panel and the second detector panel, a tracking system configured to detect a position of said second detector panel relative to the first detector panel while imaging a subject, a computing device in communication with the first detector panel, the second detector panel, and the tracking system, the computing device configured to receive coincidence data from the first and second detector panels, receive position data from the tracking system, wherein each coincidence datum of the received coincidence data is associated with a unique position datum of the received position data, and reconstruct a plurality of images based on the received coincidence data and the received position data.

Tai, Yuan-Chuan↗

Stimulated emission tomography for efficient characterization of spatial entanglement

Stimulated-emission tomography (SET) is an excellent tool for characterizing the process of spontaneous parametric down conversion (SPDC), which is commonly used to create pairs of entangled photons for use in quantum information protocols. The use of stimulated emission increases the average number of detected photons by several orders of magnitude compared to the spontaneous process. In a SET measurement, the parametric down conversion is seeded by an intense signal field prepared with specified mode properties rather than by broadband multimodal vacuum fluctuations, as is the case for the spontaneous process. The SET process generates an intense idler field in a mode that is the complex conjugate to the signal mode. In this work we use SET to estimate the joint spatial mode distribution (JSMD) in the Laguerre-Gaussian (LG) basis of the two photons of an entangled photon pair. The pair is produced by parametric down conversion in a beta barium borate (BBO) crystal with type-II phase matching pumped at a wavelength of 405 nm along with a 780 nm seed signal beam prepared in a variety of LG modes to generate an 842 nm idler beam of which the spatial mode distribution is measured. We observe strong idler production and good agreement with the theoretical prediction of its spatial mode distribution. Our experimental procedure should enable the efficient determination of the photon-pair wavefunctions produced by low-brightness SPDC sources and the characterization of high-dimensional entangled-photon pairs. Published by the American Physical Society 2024

Xu, Yang (ORCID:0009000954547320)↗

Evaluation of a positron-emission-tomography-based SiPM readout for compact segmented neutron imagers

Gamma-ray emission from special nuclear material (SNM) is relatively easy to shield from detection using modest amounts of high-Z material. In contrast, fast-neutrons are much more penetrating and can escape relatively thick high-Z shielding without losing significant energy. Furthermore, fast neutrons provide a clear and unambiguous signature of the presence of SNM with few competing natural background sources. The challenge of detecting fast neutrons is twofold. First, the neutron flux from SNM are only a fraction of the corresponding gamma-ray flux. Second, fast neutrons can be difficult to differentiate from gamma rays. The ability to discriminate gamma rays from neutrons, combined with a neutron imaging capability, can in some situations enable the localization of SNM neutron sources distinct from background. With the developments of pulse-shape-sensitive plastic scintillators that offer excellent gamma-ray/neutron discrimination, and arrays of silicon photomultipliers combined with highly scalable and fast positron-emission-tomography (PET) multi-channel readout systems, field-deployable neutron imagers suitable for SNM detection might now be within reach. In this paper, we present a characterization of the performance of a recently available commercial PET-scanner readout, including its sensitivity to pulse-shape differences between fast neutrons and gamma rays, energy and timing resolution. Here, we find that, while the pulse-shape discrimination is achievable with stilbene, further improvement of the readout is required to achieve it with the PSD-capable available plastic scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Harmonizing tau positron emission tomography in Alzheimer's disease: The CenTauR scale and the joint propagation model

Abstract INTRODUCTION Tau‐positron emission tomography (PET) outcome data of patients with Alzheimer's disease (AD) cannot currently be meaningfully compared or combined when different tracers are used due to differences in tracer properties, instrumentation, and methods of analysis. METHODS Using head‐to‐head data from five cohorts with tau PET radiotracers designed to target tau deposition in AD, we tested a joint propagation model (JPM) to harmonize quantification (units termed “CenTauR” [CTR]). JPM is a statistical model that simultaneously models the relationships between head‐to‐head and anchor point data. JPM was compared to a linear regression approach analogous to the one used in the amyloid PET Centiloid scale. RESULTS A strong linear relationship was observed between CTR values across brain regions. Using the JPM approach, CTR estimates were similar to, but more accurate than, those derived using the linear regression approach. DISCUSSION Preliminary findings using the JPM support the development and adoption of a universal scale for tau‐PET quantification. Highlights Tested a novel joint propagation model (JPM) to harmonize quantification of tau PET. Units of common scale are termed “CenTauRs”. Tested a Centiloid‐like linear regression approach. Using five cohorts with head‐to‐head tau PET, JPM outperformed linearregressionbased approach. Strong linear relationship was observed between CenTauRs values across brain regions.

Neurosciences & Neurology↗

Initial Measurements with the Prototype Parallel-Slit Ring Collimator Fast Neutron Emission Tomography System

Since 2017, Oak Ridge National Laboratory (ORNL) has been developing a passive fast-neutron emission tomography capability. The goal of this development is the ability to quantify the neutron source strength of individual fuel pins (rods) in spent nuclear fuel assemblies. Such a system could be used to measure the burnup of each fuel pin in a spent fuel assembly to take burnup credit when loading dry storage casks or to count individual fuel pins in spent fuel assemblies for safeguards purposes. At present, a laboratory prototype imager has been built and initial imaging measurements performed. The purpose of this prototype is to demonstrate imaging capability sufficient to resolve individual fuel pins in spent fuel assemblies, and in initial measurements, neutron sources separated by a spacing of 1.27 cm (similar to the spacing between fuel pins in commercial pressurized water reactor 17×17 nuclear fuel assemblies) have been resolved. This report documents the as-built imager, first measurements performed with it, and tomographic reconstructions performed using the measured data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Tomographic Image Reconstruction for the Parallel-Slit Ring Collimator Fast Neutron Emission Tomography System

For the past three years, Oak Ridge National Laboratory (ORNL) has been developing a passive fast-neutron emission tomography capability. The goal of this development is the ability to quantify the neutron source strength of individual fuel pins (rods) in spent nuclear fuel assemblies. Such a system could be used to measure the burnup of each fuel pin in a spent fuel assembly in order to take burnup credit when loading dry storage casks or to count individual fuel pins in spent fuel assemblies for safeguards purposes. At present, a laboratory prototype imager is under construction. The purpose of this prototype is to demonstrate imaging capability sufficient to resolve individual fuel pins in spent fuel assemblies. This report documents the development of the iterative reconstruction code used to perform tomographic image reconstruction, the imager response calculation used by the reconstruction code, and the results of reconstructions of simulated tomographic imaging measurements for the prototype imager design.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assembly and Initial Testing of the Gamma-Ray Emission Tomography Assessment Prototype for Irradiated Fuel

The following report documents the final development, assembly, and initial testing of the gamma-ray emission tomography assessment system (GRETA-1) for post-irradiation examination of irradiated fuel. It includes descriptions of the system components, including the high-purity germanium gamma-ray detector, the surrounding shield and collimator, the sample scanning hardware, and the control and collection software package. A series of MCNP6 simulations were performed that modeled a fuel rod scan to test image reconstruction algorithms with a complex and understood source distribution. A bench-top scan of isotopic check sources was also performed and analyzed using standard image reconstruction algorithms. The system is currently awaiting deployment at Idaho National Laboratory’s Hot Fuel Examination Facility.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Quantitative imaging and automated fuel pin identification for passive gamma emission tomography

Compliance of member States to the Treaty on the Non-Proliferation of Nuclear Weapons is monitored through nuclear safeguards. The Passive Gamma Emission Tomography (PGET) system is a novel instrument developed within the framework of the International Atomic Energy Agency (IAEA) project JNT 1510, which included the European Commission, Finland, Hungary and Sweden. The PGET is used for the verification of spent nuclear fuel stored in water pools. Advanced image reconstruction techniques are crucial for obtaining high-quality cross-sectional images of the spent-fuel bundle to allow inspectors of the IAEA to monitor nuclear material and promptly identify its diversion. In this work, we have developed a software suite to accurately reconstruct the spent-fuel cross sectional image, automatically identify present fuel rods, and estimate their activity. Unique image reconstruction challenges are posed by the measurement of spent fuel, due to its high activity and the self-attenuation. While the former is mitigated by detector physical collimation, we implemented a linear forward model to model the detector responses to the fuel rods inside the PGET, to account for the latter. The image reconstruction is performed by solving a regularized linear inverse problem using the fast-iterative shrinkage-thresholding algorithm. We have also implemented the traditional filtered back projection (FBP) method based on the inverse Radon transform for comparison and applied both methods to reconstruct images of simulated mockup fuel assemblies. Higher image resolution and fewer reconstruction artifacts were obtained with the inverse-problem approach, with the mean-square-error reduced by 50%, and the structural-similarity improved by 200%. We then used a convolutional neural network (CNN) to automatically identify the bundle type and extract the pin locations from the images; the estimated activity levels finally being compared with the ground truth. The proposed computational methods accurately estimated the activity levels of the present pins, with an associated uncertainty of approximately 5%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Three‐Dimensional Permeability Inversion Using Convolutional Neural Networks and Positron Emission Tomography

Abstract Quantification of heterogeneous multiscale permeability in geologic porous media is key for understanding and predicting flow and transport processes in the subsurface. Recent utilization of in situ imaging, specifically positron emission tomography (PET), enables the measurement of three‐dimensional (3‐D) time‐lapse radiotracer solute transport in geologic media. However, accurate and computationally efficient characterization of the permeability distribution that controls the solute transport process remains challenging. Leveraging the relationship between local permeability variation and solute advection behavior, an encoder‐decoder based convolutional neural network (CNN) is implemented as a permeability inversion scheme using a single PET scan of a radiotracer pulse injection experiment as input. The CNN can accurately capture the 3‐D spatial correlation between the permeability and the radiotracer solute arrival time difference maps in geologic cores. We first test the inversion accuracy using synthetic test datasets and then test the accuracy on a suite of experimental PET imaging datasets acquired on four different geologic cores. The network‐predicted permeability maps from the geologic cores are used to parameterize forward numerical models that are directly compared with the experimental PET imaging data. The results indicate that a single trained network can generate robust 3‐D permeability inversion maps in seconds. Numerical models parameterized with these permeability maps closely capture the experimentally observed solute arrival time behavior. This work provides an unprecedented approach for efficiently characterizing multiscale permeability heterogeneity in complex geologic samples.

54 ENVIRONMENTAL SCIENCES↗

Positron emission tomography harmonization in the Alzheimer's Disease Neuroimaging Initiative: A scalable and rigorous approach to multisite amyloid and tau quantification

Abstract INTRODUCTION A key goal of the Alzheimer's Disease NeuroImaging Initiative (ADNI) positron emission tomography (PET) Core is to harmonize quantification of β‐amyloid (Aβ) and tau PET image data across multiple scanners and tracers. METHODS We developed an analysis pipeline (Berkeley PET Imaging Pipeline, B‐PIP) for ADNI Aβ and tau PET images and applied it to PET data from other multisite studies. Steps include image pre‐processing, refacing, magnetic resonance imaging (MRI)/PET co‐registration, visual quality control (QC), quantification of tracer uptake, and standardization of Aβ and tau standardized uptake value ratios (SUVrs) across tracers. RESULTS Measurements from 10,105 cross‐sectional and longitudinal Aβ and tau PET scans acquired in several studies between 2010 and 2024 can be processed, harmonized, and directly merged across tracers and cohorts. DISCUSSION The B‐PIP developed in ADNI is a scalable image harmonization approach used in several observational studies and clinical trials that facilitates rigorous Aβ and tau PET quantification and data sharing. Highlights Quantitative results from ADNI Aβ and tau PET data are generated using a rigorous, scalable image processing pipeline This pipeline has been applied to PET data from several other large, multisite studies and trials Quantitative outcomes are harmonizable across studies and are shared with the scientific community

Neurosciences & Neurology↗

Tau Positron Emission Tomography for Predicting Dementia in Individuals With Mild Cognitive Impairment

An accurate prognosis is especially pertinent in mild cognitive impairment (MCI), when individuals experience considerable uncertainty about future progression. To evaluate the prognostic value of tau positron emission tomography (PET) to predict clinical progression from MCI to dementia. This was a multicenter cohort study with external validation and a mean (SD) follow-up of 2.0 (1.1) years. Data were collected from centers in South Korea, Sweden, the US, and Switzerland from June 2014 to January 2024. Participant data were retrospectively collected and inclusion criteria were a baseline clinical diagnosis of MCI; longitudinal clinical follow-up; a Mini-Mental State Examination (MMSE) score greater than 22; and available tau PET, amyloid-β (Aβ) PET, and magnetic resonance imaging (MRI) scan less than 1 year from diagnosis. A total of 448 eligible individuals with MCI were included (331 in the discovery cohort and 117 in the validation cohort). None of these participants were excluded over the course of the study. Exposures included Tau PET, Aβ PET, and MRI. Positive results on tau PET (temporal meta–region of interest), Aβ PET (global; expressed in the standardized metric Centiloids), and MRI (Alzheimer disease [AD] signature region) was assessed using quantitative thresholds and visual reads. Clinical progression from MCI to all-cause dementia (regardless of suspected etiology) or to AD dementia (AD as suspected etiology) served as the primary outcomes. The primary analyses were receiver operating characteristics. In the discovery cohort, the mean (SD) age was 70.9 (8.5) years, 191 (58%) were male, the mean (SD) MMSE score was 27.1 (1.9), and 110 individuals with MCI (33%) converted to dementia (71 to AD dementia). Only the model with tau PET predicted all-cause dementia (area under the receiver operating characteristic curve [AUC], 0.75; 95% CI, 0.70-0.80) better than a base model including age, sex, education, and MMSE score (AUC, 0.71; 95% CI, 0.65-0.77; P = .02), while the models assessing the other neuroimaging markers did not improve prediction. In the validation cohort, tau PET replicated in predicting all-cause dementia. Compared to the base model (AUC, 0.75; 95% CI, 0.69-0.82), prediction of AD dementia in the discovery cohort was significantly improved by including tau PET (AUC, 0.84; 95% CI, 0.79-0.89; P < .001), tau PET visual read (AUC, 0.83; 95% CI, 0.78-0.88; P = .001), and Aβ PET Centiloids (AUC, 0.83; 95% CI, 0.78-0.88; P = .03). In the validation cohort, only the tau PET and the tau PET visual reads replicated in predicting AD dementia. In this study, tau-PET showed the best performance as a stand-alone marker to predict progression to dementia among individuals with MCI. This suggests that, for prognostic purposes in MCI, a tau PET scan may be the best currently available neuroimaging marker.

59 BASIC BIOLOGICAL SCIENCES↗

Primary Mediastinal B Cell Lymphoma in the Positron-Emission Tomography Era Executive Summary of the American Radium Society Appropriate Use Criteria

Primary mediastinal B cell lymphoma (PMBCL) is a highly curable subtype of non-Hodgkin lymphoma that is diagnosed predominantly in adolescents and young adults. Consequently, long-term treatment-related morbidity is critical to consider when devising treatment strategies that include different chemoimmunotherapy strategies with or without radiation therapy. Furthermore, adaptive approaches using the end-of-chemotherapy (EOC) positron emission tomography (PET)/computed tomography (CT) scanning may help to determine which patients may benefit from additional therapies. We aimed to develop evidence-based guidelines for treating these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-dimensional electron temperature measurement of inertial confinement fusion hotspots using x-ray emission tomography

Here we present a novel approach to reconstruct three-dimensional (3D) electron temperature distributions of inertially confined fusion plasma hotspots at the National Ignition Facility. Using very limited number of two-dimensional (2D) x-ray imaging lines of sight, we perform 3D reconstructions of x-ray emission distributions from different x-ray energy channels ranging from 20 to 30 keV. 2D time-integrated x-ray images are processed using the algebraic reconstruction technique to reconstruct a 3D hotspot x-ray emission distribution that is self-consistent with the input images. 3D electron temperatures are computed using the energy channel ratios. We demonstrate the high accuracy and applicability of this method with different complex hotspot geometries in both synthetic and experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-dimensional hot-spot x-ray emission tomography from cryogenic deuterium–tritium direct-drive implosions on OMEGA

A three-dimensional model of the hot-spot x-ray emission has been developed and applied to the study of low-mode drive asymmetries in direct-drive inertial confinement fusion implosions on OMEGA with cryogenic deuterium–tritium targets. Here, the steady-state model assumes an optically thin plasma and the data from four x-ray diagnostics along quasi-orthogonal lines of sight are used to obtain a tomographic reconstruction of the hot spot. A quantitative analysis of the hot-spot shape is achieved by projecting the x-ray emission into the diagnostic planes and comparing this projection to the measurements. The model was validated with radiation-hydrodynamic simulations assuming a mode-2 laser illumination perturbation resulting in an elliptically shaped hot spot, which was accurately reconstructed by the model using synthetic x-ray images. This technique was applied to experimental data from implosions in polar-direct-drive illumination geometry with a deliberate laser-drive asymmetry, and the hot-spot emission was reconstructed using spherical-harmonic modes of up to ℓ = 3. A 10% stronger drive on the equator relative to that on the poles resulted in a prolate-shaped hot spot at stagnation with a large negative A 2,0 coefficient of A 2,0 = –0.47 ± 0.03, directly connecting the modal contribution of the hot-spot shape with the modal contribution in laser-drive asymmetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Positron Emission Tomography Imaging of Functional Transforming Growth Factor β (TGFβ) Activity and Benefit of TGFβ Inhibition in Irradiated Intracranial Tumors

Transforming growth factor β (TGFβ) promotes cell survival by endorsing DNA damage repair and mediates an immunosuppressive tumor microenvironment. Thus, TGFβ activation in response to radiation therapy is potentially targetable because it opposes therapeutic control. Strategies to assess this potential in the clinic are needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗