At least 19 records

Active minimization of energy density in three-dimensional enclosures

The objective of this research project is to further investigate and develop a novel approach for actively controlling the sound field in enclosures. Typically the acoustic field in an enclosure has been controlled by minimizing the sum of the squared pressures from several microphones distributed throughout the enclosure. The approach being investigated in this project involves minimizing the acoustic energy density at the sensor locations, rather than the squared pressure. Previous research in a simple one-dimensional enclosure showed that improved global attenuation of the acoustic field is often obtained by minimizing the energy density, rather than the pressure. The current project builds on the previous research by extending the method of controlling the acoustic energy density to three-dimensional enclosures. The results will establish if improved control can still be expected in a more general enclosure. Pending successful results, the method could be applied to control problems such as attenuating the acoustic noise in an aircraft fuselage, an automobile cabin, or other general enclosures. The research project was set up as a two-year project designed to achieve both numerical and experimental results. The primary focus of the first year of research (now being completed) was on the analytical/numerical modeling of the method of controlling the acoustic energy density. During the second year, the research focuses on experimental verification of the approach and extending our understanding of the method.

Sommerfeldt, Scott D.↗

Application of static and dynamic enclosures for determining dimethyl sulfide and carbonyl sulfide exchange in Sphagnum peatlands: Implications for the magnitude and direction of flux

A static enclosure method was applied to determine the exchange of dimethyl sulfide (DMS) and carbonyl sulfide (OCS) between the surface of Sphagnum peatlands and the atmosphere. Measurements were performed concurrently with dynamic (flow through) enclosure measurements with sulfur-free air used as sweep gas. This latter technique has been used to acquire the majority of available data on the exchange of S gases between the atmosphere and the continental surfaces and has been criticized because it is thought to overestimate the true flux of gases by disrupting natural S gas gradients. DMS emission rates determined by both methods were not statistically different between 4 and greater than 400 nmol/sq m/h, indicating that previous data on emissions of at least DMS are probably valid. However, the increase in DMS in static enclosures was not linear, indicating the potential for a negative feedback of enlosure DMS concentrations on efflux. The dynamic enclosure method measured positive OCS flux rates (emission) at all sites, while data using static enclosures indicated that OCS was consumed from the atmosphere at these same sites at rates of 3.7 to 55 nmol/sq m/h. Measurements using both enclosure techniques at a site devoid of vegetation showed that peat was a source of both DMS and OCS. However, the rate of OCS efflux from decomposing peat was more than counterbalanced by OCS consumption by vegetation, including Sphagnum mosses, and net OCS uptake occurred at all sites. We propose that all wetlands are net sinks for OCS.

De Mello, William Z.↗

Active minimization of energy density in three-dimensional enclosures

The objective of this study was to further investigate and develop a novel approach for actively controlling the sound field in enclosures that is based on the acoustic energy density. Typically the acoustic field in an enclosure has been controlled by minimizing the sum of the squared pressures from several microphones distributed throughout the enclosure. The approach investigated in this study involved minimizing the acoustic energy density at the sensor locations, rather than the squared pressure. Research previous to this study in a simple one-dimensional enclosure showed that improved global attenuation of the acoustic field is often obtained by minimizing the energy density, rather than the pressure. The current study built on the previous research by extending the method of controlling the acoustic energy density to three-dimensional enclosures. The study was intended to help establish if improved control can still be expected in a more general enclosure. The study was designed to be both analytical/numerical and experimental in nature.

Sommerfeldt, Scott D.↗

Net radiation method for enclosure systems involving partially transparent walls

The net radiation method is developed for analyzing radiation heat transfer in enclosure systems involving partially transparent walls. One such system is an enclosure with windows in it. The conventional net radiation method was developed for enclosures having opaque walls. If a partially transparent wall is present, it will permit radiation to enter and leave the enclosure. The net radiation equations are developed here for gray and semigray enclosures with one or more windows. Another system of interest, such as in a flat plate solar collector, consists of a series of parallel transparent layers. The transmission characteristics of such window systems are obtained by the net radiation method, and the technique appears to be more convenient than the ray tracing method which has been used in the past. Relations are developed for windows consisting of any number of parallel layers having differing absorption coefficients and differing surface reflectivities, and for systems composed of parallel transmitting layers and opaque plates.

Siegel, R.↗

Electrical enclosure hydrogen intrusion study

As a cost savings measure for the space shuttle program, the feasibility of substituting dry air for nitrogen as the purge gas used to minimize the probability of fire and explosions which could erupt from propellant vapor (hydrogen) diffusion into the electrical enclosures at Launch Complex 39 was investigated. It was concluded that: (1) Hydrogen concentrations of approximately 1% were obtained in an electrical enclosure under design purge conditions. (2) Hydrogen concentrations exceeding the lower explosive limit, 4%, could probably be obtained within the enclosure under worst case conditions. (3) Most of the hydrogen intrusion into the enclosure probably occurred at the point with the shortest leak path, such as the door seal. (4) More stringent electrical enclosure design requirements should be imposed before air is using as a purge gas.

Welch, P. J.↗

Shielding Effectiveness of Metallic Enclosures at Oblique and Arbitrary Polarizations

Shielding effectiveness of metallic enclosures with apertures when illuminated by an oblique incidence arbitrary polarized plane wave has been studied by using an efficient hybrid modal/moment technique. Shielding effectiveness of rectangular enclosures with one, two, and four apertures at multiple points inside the enclosures for various frequencies has been calculated when the illuminating source flies by the front of the enclosure. The work shows that the shielding effectiveness is seriously affected by frequency, angle of incidence and polarization of the illuminating field; the number and orientation of apertures; and the location inside the cavity. It has been shown that the usual assumption about the normal incidence being the worst-case scenario for shielding effectiveness values may not be valid when there is more than one aperture in the cavity. The paper emphasizes the need for the statistical investigation of shielding effectiveness problem of metallic enclosures with apertures.

Deshpande, Manohar D.↗

Application of the relative energy release criteria to enclosure fire testing

The five relative energy release criteria (RERC) which are a first step towards formulating a unified concept that can be applied to the development of fires in enclosures, place upper bounds on the rate and amount of energy released during a fire. They are independent, calculated readily, and may be applied generally to any enclosure regardless of size. They are useful in pretest planning and for interpreting experimental data. Data from several specific fire test programs were examined to evaluate the potential use of RERC to provide test planning guidelines. The RERC were compared with experimental data obtained in full-scale enclosures. These results confirm that in general the RERC do identify the proper limiting constraints on enclosure fire development and determine the bounds of the fire development envelope. Plotting actual fire data against the RERC reveals new valid insights into fire behavior and reveals the controlling constraints in fire development. The RERC were calculated and plotted for several descrpitions of full-scale fires in various aircraft compartments.

Roschke, E. J.↗

Enclosure fire hazard analysis using relative energy release criteria

A method for predicting the probable course of fire development in an enclosure is presented. This fire modeling approach uses a graphic plot of five fire development constraints, the relative energy release criteria (RERC), to bound the heat release rates in an enclosure as a function of time. The five RERC are flame spread rate, fuel surface area, ventilation, enclosure volume, and total fuel load. They may be calculated versus time based on the specified or empirical conditions describing the specific enclosure, the fuel type and load, and the ventilation. The calculation of these five criteria, using the common basis of energy release rates versus time, provides a unifying framework for the utilization of available experimental data from all phases of fire development. The plot of these criteria reveals the probable fire development envelope and indicates which fire constraint will be controlling during a criteria time period. Examples of RERC application to fire characterization and control and to hazard analysis are presented along with recommendations for the further development of the concept.

Coulbert, C. D.↗

Development of a General Method for Determining Leak Rates from Limiting Enclosures

This paper discusses the development of a general method for the determination of very low leak rates from limiting enclosures. There are many methods that can be used to detect and repair leaks from enclosures. Many methods have also been proposed that allow the estimation of actual leak rates, usually expressed as enclosure volume turnover. The proposed method combines measurements of the state variables (pressure, temperature, and volume) as well as the change in the concentration of a tracer gas to estimate the leak rate. The method was applied to the containment enclosure of the Engineering Development Unit of the CELSS Test Facility, currently undergoing testing at the NASA Ames Research Center.

Zografos, A. I.↗

On the Maximum Expected Electric Field in Electrically Small, Undermoded Enclosures

This paper reports the experimental validation of an improved statistical model for the prediction of maximum expected electric field in electrically small and under-moded enclosures. The aerospace community is interested in application of Hill’s statistical models to design of avionics boxes for shielding effectiveness and for tailoring EMC test requirements for critical applications. However, it is observed that the probability distribution for mean-squared electric field (|E(sub x)|(exp 2)) in an electrically small enclosure differs from the exponential distribution which is widely used in reverberation chamber testing. It is postulated here that the difference is attributable to the under-moded character of the small enclosure. We will define “under-moded” as the condition where a single excitation frequency does not excite enough closely spaced resonant modes to achieve Hill’s assumption of an isotropic (or fully diffuse) plane wave field in the enclosure.

Bremner, P. G.↗

Advanced Modular Power System Fully Populated Electronics Enclosure Thermal Testing

A thermal test of an enclosure housing the AMPS electronics cards was performed. The enclosure was fully populated with 17 nonfunctioning AMPS electronics cards. Heaters were applied to the cards to simulate their operation. A cold plate was installed on the top of the case. The case was then insulated to simulate its installation within an electronics rack with the face and rear of the enclosure left open. The cold plate was connected to a chiller which provided cooling water at a fixed input temperature to the cold plate. Flow rates from the chiller of 0.0 L/min, 1.4 L/min and 1.8 L/min were tested. The test was operated at each flow rate over a range of heater power levels until the steady state temperature of the electronics cards was reached. Heater power levels from 2.5 W/card to 45 W/card were tested. The data collected was used to determine the steady state operating temperature of the cards, the temperature distribution between the cards, the time to reach steady-state temperature, the change in steady state temperature with change in heater power, the temperature distribution between the cards at the steady state condition and the heat lost to the surrounds by the enclosure. One of the main goals of the testing was to determine how much waste heat the cards could generate and still maintain a touch temperature at or below 40°C. Based on this requirement, for the 3 cooling rates tested, the maximum card waste heat that could be generated by each individual card was 3.9 W, 16.3 W and 17.6 W respectively. An analysis was also set up to provide an analytical model to estimate the card temperature under different cold plate flow rates and card heater power levels. The results off the analysis was compared to that of the experiment of the range of flow rates and power levels tested.

Anthony Colozza↗

Radiative equilibrium in a rectangular enclosure bounded by gray walls

Two-dimensional temperature and heat-flux distributions are calculated for an absorbing-emitting gray medium at radiative equilibrium in a rectangular enclosure. The bounding walls are gray and diffuse with arbitrary surface-temperature distributions, and heat generation may take place inside the medium. As a first approximation, the problem is solved for optically thick systems (differential approximation). These results are subsequently improved by the introduction of a number of geometrical parameters to yield good accuracy for all optical thicknesses. As examples, two cases are discussed in detail: (1) uniform heat generation in a black enclosure, and (2) an enclosure with one gray surface at constant temperature. Comparison with some numerical solutions generated by Hottel's /Hottel and Cohen (1958) and Einstein (1963)/ zonal method shows excellent agreement.

Modest, M. F.↗

Tissue stimulator enclosure welding fixture

It was demonstrated that the thickness of the stimulator titanium enclosure is directly related to the battery recharge time cycle. Reduction of the titanium enclosure thickness from approximately 0.37 mm (0.015 inch) to 0.05 mm (0.002 inch) significantly reduced the recharge time cycle and thereby patient inconvenience. However, fabrication of titanium enclosures from the thinner material introduced problems in forming, holding, and welding that required improvement in state of the art shop practices. The procedures that were utilized to resolve these fabrication problems are described.

Mcclure, S. R.↗

Experimental determination of the particle motions associated with the low order acoustic modes in enclosures

A procedure for experimentally determining, in terms of the particle motions, the shapes of the low order acoustic modes in enclosures is described. The procedure is based on finding differentiable functions which approximate the shape functions of the low order acoustic modes when these modes are defined in terms of the acoustic pressure. The differentiable approximating functions are formed from polynomials which are fitted by a least squares procedure to experimentally determined values which define the shapes of the low order acoustic modes in terms of the acoustic pressure. These experimentally determined values are found by a conventional technique in which the transfer functions, which relate the acoustic pressures at an array of points in the enclosure to the volume velocity of a fixed point source, are measured. The gradient of the function which approximates the shape of a particular mode in terms of the acoustic pressure is evaluated to give the mode shape in terms of the particle motion. The procedure was tested by using it to experimentally determine the shapes of the low order acoustic modes in a small rectangular enclosure.

Byrne, K. P.↗

Analytical study of acoustic response of a semireverberant enclosure with application to active noise control

The acoustic response of a semireverberant enclosure with two interacting, velocity-prescribed source distributions was analyzed using standard modal analysis techniques with a view toward a better understanding of active noise control. Different source and enclosure dimensions, source separations, and single-wall admittances were studied over representative frequency bandwidths of 10 Hz with source relative phase as a parameter. Results indicate that power radiated into the enclosure agree qualitatively with the spatial average of the mean square pressure, even though the reverberant field is nondiffuse. Decreases in acoustic power can therefore be used to estimate global noise reduction in a nondiffuse semireverberant environment. As might be expected, parametric studies indicate that maximum power reductions of up to 25 dB can be achieved when secondary and primary sources are compact and closely spaced. Although less success is achieved with increasing frequency and source separation or size, significant suppression of up to 8 dB still occurs over the 1 to 2 Hz bandwidth.

Parrott, T. L.↗

Thermal enclosures for electronically scanned pressure modules operating in cryogenic environments

Specific guidelines to design, construct, and test ESP thermal enclosures for applications at cryogenic temperatures are given. The enclosures maintain the ESP modules at a constant temperature (10 C plus or minus 1 C) to minimize thermal zero and sensitivity shifts, to minimize the frequency of expensive on-line calibrations, and to avoid adverse effects on tunnel and model boundary layers. The enclosures are constructed of a rigid closed-cell foam and are capable of withstanding the stagnation pressures to 932kPa (135 psia) without reduction in thermal insulation properties. This construction procedure has been used to construct several thermal packages which have been successfully used in National Transonic Facility.

Mitchell, Michael↗

Numerical studies of convective heat transfer in an inclined semiannular enclosure

Natural convection heat transfer in a two-dimensional differentially heated semiannular enclosure is studied. The enclosure is isothermally heated and cooled at the inner and outer walls, respectively. A commercial software based on the SIMPLER algorithm was used to simulate the velocity and temperature profiles. Various parameters that affect the momentum and heat transfer processes were examined. These parameters include the Rayleigh number, Prandtl number, radius ratio, and the angle of inclination. A flow regime extending from conduction-dominated to convection-dominated flow was examined. The computed results of heat transfer are presented as a function of flow parameter and geometric factors. It is found that the heat transfer rate attains a minimum when the enclosure is tilted about +50 deg with respect to the gravitational direction.

Wang, Lin-Wen↗

Numerical studies of convective heat transfer in an inclined semi-annular enclosure

Natural convection heat transfer in a two-dimensional differentially heated semiannular enclosure is studied. The enclosure is isothermally heated and cooled at the inner and outer walls, respectively. A commercial software based on the SIMPLER algorithm was used to simulate the velocity and temperature profiles. Various parameters that affect the momentum and heat transfer processes were examined. These parameters include the Rayleigh number, Prandtl number, radius ratio, and the angle of inclination. A flow regime extending from conduction-dominated to convection-dominated flow was examined. The computed results of heat transfer are presented as a function of flow parameter and geometric factors. It is found that the heat transfer rate attains a minimum when the enclosure is tilted about +50 deg with respect to the gravitational direction.

Wang, L.-W.↗