Search NASASearch

SEARCH · Search NASA

Results for “Energy Loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The updated algorithm of the Energy Consumption Program (ECP): A computer model simulating heating and cooling energy loads in buildings

The energy Comsumption Computer Program was developed to simulate building heating and cooling loads and compute thermal and electric energy consumption and cost. This article reports on the new additional algorithms and modifications made in an effort to widen the areas of application. The program structure was rewritten accordingly to refine and advance the building model and to further reduce the processing time and cost. The program is noted for its very low cost and ease of use compared to other available codes. The accuracy of computations is not sacrificed however, since the results are expected to lie within + or - 10% of actual energy meter readings.

Lansing, F. L.

Evaluation of integral exposure energy load on aural analyzer of miners

The individual exposure integral noise load on workers before the beginning of hearing impairment was determined for a group of 20 male miners who had worked with drilling equipment and harvesters for 8 to 20 years before the onset of the disability. Results show that the total exposure energy load of about 4 kw x h sq m, obtained by miners in the examined group, resulted in occupational injury to the auditory organ (cochlear neuritis) in 75% of the cases. The equivalent energy level of noise computed according to the date of total energy load is roughly 99 db A, which significantly exceeds the permissible amount of 85 db A. There is a correlation (r = 0.77) between the integral exposure energy noise on the aural analyzer in the degree of increase in the total threshold for the mean speech range.

Kornilov, A. N.

Energy consumption program: A computer model simulating energy loads in buildings

The JPL energy consumption computer program developed as a useful tool in the on-going building modification studies in the DSN energy conservation project is described. The program simulates building heating and cooling loads and computes thermal and electric energy consumption and cost. The accuracy of computations are not sacrificed, however, since the results lie within + or - 10 percent margin compared to those read from energy meters. The program is carefully structured to reduce both user's time and running cost by asking minimum information from the user and reducing many internal time-consuming computational loops. Many unique features were added to handle two-level electronics control rooms not found in any other program.

Stoller, F. W.

JPL Energy Consumption Program (ECP) documentation: A computer model simulating heating, cooling and energy loads in buildings

The engineering manual provides a complete companion documentation about the structure of the main program and subroutines, the preparation of input data, the interpretation of output results, access and use of the program, and the detailed description of all the analytic, logical expressions and flow charts used in computations and program structure. A numerical example is provided and solved completely to show the sequence of computations followed. The program is carefully structured to reduce both user's time and costs without sacrificing accuracy. The user would expect a cost of CPU time of approximately $5.00 per building zone excluding printing costs. The accuracy, on the other hand, measured by deviation of simulated consumption from watt-hour meter readings, was found by many simulation tests not to exceed + or - 10 percent margin.

Lansing, F. L.

Stability of structural rings under uniformly distributed radial loads

Energy method analysis establishes parameters governing stability of circular rings acted upon by constant, uniformly distributed loads. Energy method is used so that nonlinear behavior of structure before buckling can be accounted for. Method affords conceptually superior basis for analyzing the axisymmetric deviation mode.

Williams, H. E.

QUOKKA-based understanding of outflows (QED) – III. Outflow loading and phase structure as a function of galactic environment

ABSTRACT We present results from a suite of 3D high-resolution hydrodynamic simulations of supernova-driven outflows from galactic disc regions with a range of gas surface density, metallicity, and supernova scale height. We use this suite to quantify how outflow properties – particularly the loading factors for mass, metallicity, and energy – vary with these parameters. We find that the winds fall into three broad categories: steady and hot, multiphase and moderately bursty, and cool and highly bursty. The first of these is characterized by efficient metal and energy loading but weak mass loading, the second by moderate loading of mass, metals, and energy, and the third by negligible metal and energy loading but substantial mass loading. The most important factor in determining the kind of wind a galaxy will produce is the ratio of supernova to gas scale heights, with the latter set by a combination of supernova rate, metallicity-dependent cooling rate, and the gravitational potential. These often combine in counterintuitive ways – for example increased cooling causes cold clouds to sink into the galactic midplane more rapidly, lowering the volume-filling factor of dense gas and making the environment more favourable for strong winds. Our findings suggest that the nature of galactic winds is likely highly sensitive to phenomena such as runaway stars occurring at a large height and dense gas and are poorly captured in most simulations, and that metal loading factors for type Ia supernovae may be substantially larger than those for type II, with important implications for galactic chemical evolution.

Vijayan, Aditi (ORCID:0000000277142379)

Electric load management and energy conservation

Electric load management and energy conservation relate heavily to the major problems facing power industry at present. The three basic modes of energy conservation are identified as demand reduction, increased efficiency and substitution for scarce fuels. Direct and indirect load management objectives are to reduce peak loads and have future growth in electricity requirements in such a manner to cause more of it to fall off the system's peak. In this paper, an overview of proposed and implemented load management options is presented. Research opportunities exist for the evaluation of socio-economic impacts of energy conservation and load management schemes specially on the electric power industry itself.

Kheir, N. A.

Filament Extension Atomization for High Solids Loading in Energy Efficient Spray Drying Systems

We demonstrate that we could scale FEA to reach outputs needed by industrial production, while increasing solids loading of the sprayed product by at least 30% and maintaining equal or better spray powder. After testing a wide range of products, in collaboration with industry partners we decided on our primary spray products of dry whey and WPC-80, two common materials processed and sold by US manufacturers with different parameters. We sprayed these with FEA at solids loadings of 70% for dry whey and 45% for WPC-80 with a spray output with particle sizes similar to industrial particles sizes and reduced variation in particle size. We simultaneously scaled up FEA first with a multi-nip with 6 nips surrounding a central roller with parallel axis of rotation and eventually with a tapered design that solved problems we encountered with our initial design. We were able to achieve output from a single array from our first design of up to 4.7 liters per minute (L/min) and from an array of our second multi-nip of 8 L/min exceeding expectations. This demonstrates that FEA technology can indeed be scaled up to meet the needs of industrial production. More arrays can be added as necessary to meet a wide range of spray dryer designs. We also tested FEA to create dried powders from a small scale (10 L/hour of water removal) spray dryer. Though we were not able to produce large quantities of powder from FEA due to challenges in integration, the powder we produced was higher quality and produced from higher solids loading materials. From our technoeconomic analysis we for a typically sized spray dryer, we estimate a 27% cost reduction and 41% energy and carbon reduction for WPC-80 and a 39-57% cost reduction and 52-76% energy reduction for sweet dry whey (depending on the exact product).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Performance of a CW double electric discharge for supersonic CO lasers

The results of an experimental investigation of a CW double discharge in supersonic CO mixtures are reported. Stable discharges in CO/N2 and CO/Ar mixtures, with a maximum energy loading of 0.5 eV/CO molecule, were achieved in a small-scale continuous-flow supersonic channel. Detailed measurements of the discharge characteristics were performed, including electrostatic probe measurements of floating potential and electron number density and spectroscopic measurements of the CO vibrational population distributions. The results of these measurements indicate that the vibrational excitation efficiency of the discharge is approximately 60%, for moderate levels of main discharge current. These experiments, on a small scale, demonstrate that the double-discharge scheme provides adequate vibrational energy loading for efficient CO laser operation under CW supersonic flow conditions.

Stanton, A. C.

Optimizing district energy systems by integrating Borehole Thermal Energy Storage Using a Mixed-Integer Linear Programming g-function framework with a Multi-Timescale Rolling Horizon method

Shallow geothermal has gained increasing attention in recent years; however, a reliable framework for its accurate incorporation into large-scale energy system optimization remains lacking. This study proposes a Mixed-Integer Linear Programming (MILP) framework combined with the g-function approach to integrate Borehole Thermal Energy Storage (BTES) technology into energy system optimization. Validation against a Modelica-based reservoir network simulation demonstrates that the proposed framework effectively captures the ground thermal response under varying energy loads and accurately estimates the borefield energy supply. To enhance scalability, a Rolling Horizon with Multi-Timescale (RH-MTS) method is further introduced, reducing computational time by 73 % for the 1-year optimization model with only minor loss of optimality. The framework is demonstrated through the case study of the UC Berkeley campus. Results indicate that BTES is a cost-effective and low-carbon solution: two borefields comprising 382 boreholes can meet 8.0 % and 6.6 % of the total campus heating and cooling demand, respectively, at an average energy rate of 0.70–0.77 USD/kWh and carbon intensity of 0.54 kg-CO2/kWh. Short-term analysis reveals a 35%–65% decline in BTES energy flow after 3–6 months of continuous heating/cooling operation, while long-term simulation shows that annual energy production of BTES can vary by up to 12.0 % after four years before stabilizing. Overall, this study develops a novel optimization framework that couples physics-based g-function method with MILP optimization framework, thereby advancing methodological development for shallow-geothermal integration and providing actionable guidance for BTES deployment in district-energy systems.

Yang, Jiahui

Low-Cost Identification and Monitoring of Diverse MELs in Residential and Commercial Buildings with PowerBlade (Final Technical Report)

This report describes our progress in developing a scalable wireless metering system that integrates plug-load energy meters that measure real, reactive, and apparent power along with load monitoring based on extracting high-fidelity electrical waveform features collected at every load to capture power profiles and automatically identify and categorize MELs, and make this technology available to the research, commercial, and government sectors.

47 OTHER INSTRUMENTATION

The Energy Systems Optimization Computer Program /ESOP/ developed for Modular Integrated Utility Systems /MIUS/ analysis

A significant energy and cost savings can be obtained by integrating various utility services (space heating and cooling, electrical power generation, solid waste disposal, potable water, and waste water treatment) into a single unit which provides buildings or groups of buildings with these services. This paper presents a description of a computer program, called the Energy Systems Optimization Program (ESOP). This program predicts the loads, energy requirements, equipment sizes, and life-cycle costs of alternative methods of meeting these utility requirements. The program has been used extensively for performing energy analyses of Modular Integrated Utility Systems (MIUS).

Ferden, S. L.

Energy 101: Distributed Energy Resources and Controllable Loads [Slides]

The Energy 101: Distributed Energy Resources and Storage presentation, developed for the Energy Technology Innovation Partnership Project (ETIPP), provides an overview of distributed energy resources (DERs) and energy storage. It covers fundamental concepts, technologies, considerations, case studies, and additional resources.

14 SOLAR ENERGY

Unified Modeling Architecture for Load Management in Extreme Heat: The New York City Case

Integration of renewable resources to meet growing energy demand is becoming a global priority under decarbonization mandates. This study contributes to ongoing efforts on this key subject by assessing the feasibility of using coastal-urban renewable energy resources, namely, offshore wind and rooftop photovoltaic systems, to meet electricity demand of New York City during the intense recent heat wave period of June 2025. A unified modeling framework, based on the urbanized weather research and forecasting model, is used to simulate climate, renewable resources, and energy demand variables. Findings show significant energy load mismatch of approximately 1150 GWh over the month, between the demand and the combined renewable generation outcome. Three storage integration scenarios are analyzed to mitigate the deficits, reducing said deficits by a minimum of approximately 9% over the duration of the month. This study provides a transferable modeling framework tool for evaluating renewable integration in dense urban environments that can be used by grid operators to support grid resilience during extreme heat events.

54 ENVIRONMENTAL SCIENCES

Study of Lyndon B. Johnson Space Center utility systems

The results of an engineering study of potential energy saving utility system modifications for the NASA Lyndon B. Johnson Space Center are presented. The objective of the study was to define and analyze utility options that would provide facility energy savings in addition to the approximately 25 percent already achieved through an energy loads reduction program. A systems engineering approach was used to determine total system energy and cost savings resulting from each of the ten major options investigated. The results reported include detailed cost analyses and cost comparisons of various options. Cost are projected to the year 2000. Also included are a brief description of a mathematical model used for the analysis and the rationale used for a site survey to select buildings suitable for analysis.

Redding, T. E.

Geothermal-integrated thermally anisotropic building envelope for energy and peak-demand reduction

Buildings consume large amounts of energy for heating and cooling, while peak electricity demand places significant stress on the power grid. This paper presents a reduced-order co-simulation framework and load-oriented supervisory control strategy for a geothermal-integrated thermally anisotropic building envelope with a ground loop (TABE+GL). In TABE+GL, a hydronic loop embedded in the building envelope is directly coupled with a geothermal ground loop, allowing for bidirectional heat exchange between the envelope, the ground, and the indoor environment. A hybrid co-simulation framework was established by coupling a reduced-order resistor–capacitor (RC) thermal network model with EnergyPlus augmented with GHEDesigner modules. The RC model generated feasible heat flux options under three operating modes, and EnergyPlus predicted sensible loads, energy use, and pump energy demand. At each simulation step, a supervisory control algorithm selected the optimal loop configuration and duty factor that maximizes useful TABE geothermal utilization without exceeding the predicted sensible load, thereby avoiding overheating or cooling. Case studies were conducted for Los Angeles, California, Charleston, South Carolina, and Denver, Colorado. Results showed that the proposed framework reduced HVAC electricity consumption by 43%–67%, natural gas use for space heating by 11%–38%, and peak electricity demand by 43%–88%. These results highlight the potential of combining reduced-order envelope modeling, direct geothermal coupling, and load-oriented supervisory control to improve whole building energy performance and reduce peak demand across diverse weather conditions.

Howard, Daniel [Southern Adventist University]