Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Energy resolution and gain measurements in Argon-based gas mixtures: Exploring Ar:CF 4 for low energy measurements with TPCs

Time Projection Chambers (TPCs) are among the most advanced charged-particle detectors. Gas-filled TPCs have tracking capabilities that provide 3D-imaging of charged particles with a good energy resolution for spectroscopy. Different gas mixtures have different properties that determine the energy resolution as well as the spatial resolution. Therefore, optimization of operating conditions is required to simultaneously obtain adequate gain, energy resolution, spatial/track resolution, as well as higher drift velocities for high counting rates applications. Ar:CF 4 gas mixture has higher electron drift velocities and lower electron diffusion, which makes it an attractive candidate for TPC filling gas for low energy nuclear physics applications as compared to commonly used Ar:CH 4 and Ar:CO 2 gas mixtures, namely when tracking information is needed. However, other properties, including energy resolution and gain, remain largely unexplored in Ar:CF 4 especially at pressures and other operating conditions relevant for low-energy nuclear physics applications. Here, in this paper we report on gain and energy resolution measurements, using Gas Electron Multipliers (GEMs), in the less explored Ar:CF 4 mixture (Alfonsi et al., 2006), as well as in the more commonly used gas mixtures Ar:CH 4 and Ar:CO 2 . In addition to obtaining energy resolution and gain, we provide results from Garfield++ simulations for gain fluctuations, and their impact on energy resolution is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of energy resolution with the NEXT-White silicon photomultipliers

The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses $^{83m}$Kr data from the NEXT-White detector to measure and understand the energy resolution that can be obtained with the SiPMs, rather than with PMTs. The energy resolution obtained of (10.9 ± 0.6)%, full-width half-maximum, is slightly larger than predicted based on the photon statistics resulting from very low light detection coverage of the SiPM plane in the NEXT-White detector. The difference in the predicted and measured resolution is attributed to poor corrections, which are expected to be improved with larger statistics. Furthermore, the noise of the SiPMs is shown to not be a dominant factor in the energy resolution and may be negligible when noise subtraction is applied appropriately, for high-energy events or larger SiPM coverage detectors. These results, which are extrapolated to estimate the response of large coverage SiPM planes, are promising for the development of future, SiPM-only, readout planes that can offer imaging and achieve similar energy resolution to that previously demonstrated with PMTs.[graphic not available: see fulltext]

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Device response principles and the impact on energy resolution of epitaxial quantum dot scintillators with monolithic photodetector integration

Abstract Epitaxial quantum dot (QD) scintillator crystals with picosecond-scale timing and high light yield have been created for medical imaging, high energy physics and national security applications. Monolithic photodetector (PD) integration enables the sensing of photons generated within the waveguiding crystal and allows a wide range of scintillator-photodetector coupling geometries. Until recently, these doubly novel devices have suffered from complex, high variance responses to monoenergetic sources which significantly reduces their precision and accuracy. The principles governing the overall device response have now been discerned and embodied by an expression derived within a geometrical optics framework which considers optical properties, surface roughness and photodetector coupling geometry. Response variation due to these factors was sufficiently reduced to obtain material-related energy resolution values of 2.4% with alpha particles. These findings place energy resolution alongside luminescence timescale, photon yield, and radiation hardness as outstanding properties of these engineered materials.

36 MATERIALS SCIENCE↗

Characterizing the energy resolution of the MicroBooNE LArTPC at the MeV scale using monoenergetic features of 208-Tl decays

A proper understanding of the capabilities and fidelity of low-energy reconstruction is crucial for taking advantage of MeV-scale neutrino physics opportunities in LArTPCs. This poster will present an analysis resulting in the first-ever demonstration of LArTPC energy resolution in the MeV regime. A measurement of the resolution of energy reconstruction in the MicroBooNE LArTPC at ~1.5 MeV was performed using monoenergetic signals generated by 208Tl decay gamma-rays pair-producing in the detector. This study provides a pathway for MeV-scale monoenergetic energy calibrations in future LArTPC experiments.

Manuel Alves, Maria Gabriela [IIT, Chicago] (ORCID↗

MeV-Scale Energy Resolution Calibration in MicroBooNE

We report MicroBooNE s first energy resolution calibration in the MeV scale, obtained from a monoenergetic feature from 208-Tl gamma s pair production. Our analysis lead to a (9.37 0.90)% resolution, which is consistent with the prediction from previous simulation studies and further demonstrates the LArTPC capabilities for MeV-scale physics.

Alves, Maria G.M. [IIT, Chicago] (ORCID:0000000219↗

Demonstration of Sub-Percent Energy Resolution in the NEXT-100 Detector

NEXT-100 is a high-pressure xenon time projection chamber with electroluminescent amplification, designed to operate with up to approximately 70.5 kg at 13.5 bar. It is the most recent detector developed by the NEXT collaboration to search for the neutrinoless double-beta decay ($ββ0ν$) of Xe-136. The NEXT gas TPC technology offers the best energy resolution near the Q-value of the decay ($Q_{ββ}$ = 2458 keV) among xenon detectors, which is set by design to be <1% FWHM. We report here the high-energy calibration of the detector using a Th-228 source, demonstrating linear response and an energy resolution of $(0.90 \pm 0.02)$% FWHM at the Tl-208 photopeak (2615 keV). This performance extrapolates to a resolution at the double-beta decay end-point of $R(Q_{ββ})$ = $(0.93 \pm 0.02)$% FWHM, confirming the detector's capability for precision energy measurement in the search for $ββ0ν$.

Pérez Maneiro, M. [Santiago de Compostela U., IGFA↗

Development of High Energy Resolution Fluorescence Detection Methods for Advanced Microscale X-ray Absorption Fine Structure Analysis of Critical Elements (Final Report)

This project is developing High-Energy Resolution Fluorescence Detection (HERFD) X-ray Absorption Fine-Structure Spectroscopy (XAFS) at the hard X-ray microprobe beamline at GSECARS beamline 13-ID-E, at the Advanced Photon Source at Argonne National Laboratory. This enhancement will improve sensitivity and spectral interpretation limitations of conventional XAFS which uses energy dispersive solid-state detectors (SSD) to measure the total fluorescence yield (TFY-XAFS). By using high-quality Si and Ge crystal analyzers to select X-ray fluorescence (XRF) from specific emission lines, background signals from other elements or X-ray scattering that can paralyze SSDs can be nearly eliminated, improving the sensitivity to the oxidation and chemical state of dilute species even though the solid angle of the analyzers is relatively small. Furthermore, by using analyzers of low-strain Si or Ge, the energy selection can be smaller than the natural widths of the core electron level. We are particularly interested in applying these enhanced sensitivities to Lanthanide series of rare-earth elements, which are typically at concentrations at or below 10 ppm, and where spectral overlaps with the 3rd row transition metals degrade sensitivity.

47 OTHER INSTRUMENTATION↗

Using pile-up collisions as an abundant source of low-energy hadronic physics processes in ATLAS and an extraction of the jet energy resolution

During the 2015–2018 data-taking period, the Large Hadron Collider delivered proton-proton bunch crossings at a centre-of-mass energy of 13 TeV to the ATLAS experiment at a rate of roughly 30 MHz, where each bunch crossing contained an average of 34 independent inelastic proton-proton collisions. The ATLAS trigger system selected roughly 1 kHz of these bunch crossings to be recorded to disk. Offline algorithms then identify one of the recorded collisions as the collision of interest for subsequent data analysis, and the remaining collisions are referred to as pile-up. Pile-up collisions represent a trigger-unbiased dataset, which is evaluated to have an integrated luminosity of 1.33 pb -1 in 2015–2018. This is small compared with the normal trigger-based ATLAS dataset, but when combined with vertex-by-vertex jet reconstruction it provides up to 50 times more dijet events than the conventional single-jet-trigger-based approach, and does so without adding any additional cost or requirements on the trigger system, readout, or storage. The pile-up dataset is validated through comparisons with a special trigger-unbiased dataset recorded by ATLAS, and its utility is demonstrated by means of a measurement of the jet energy resolution in dijet events, where the statistical uncertainty is significantly reduced for jet transverse momenta below 65 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ECAL Calibration and Energy Resolution for a 10TeV Detector Geometry

In the pursuit of a muon collider operating at ~10 TeV center-of-mass-energy, designing a highly accurate and sensitive detector is crucial. Calorimetry plays a key part in any detector setup, as we rely on our calorimeters for energy reconstruction and particle identification. Therefore, an effective calorimeter must be extremely well-calibrated and achieve excellent resolution. This poster will report on efforts to achieve a comprehensive energy calibration of the electromagnetic calorimeter (ECAL) for our 10 TeV detector design. This calibration is necessary in order to achieve desired energy resolution for reconstructed photons across a wide range of energies (0-1TeV). We report on the challenges introduced by the new location of the solenoid in our latest 10 TeV detector design, the necessity of a calibration strategy that is both energy-dependent and angularly dependent, and the resulting effects on photon energy resolution.

Powers, Rose↗

Characterizing the energy resolution of the MicroBooNE LArTPC at the MeV scale using monoenergetic features of $^{208}$Tl decays

A detailed understanding of the capabilities and fidelity of low-energy reconstruction is crucial for taking advantage of MeV-scale neutrino physics opportunities in liquid argon time projection chambers (LArTPCs). This study presents a measurement of the resolution of reconstructed energy in the MicroBooNE LArTPC at $\approx 1.5$ MeV. The characterization is performed using monoenergetic signals generated by $2.614$ MeV $γ$-rays from $^{208}$Tl decays undergoing pair production in the detector. The resolution is found to be ($7.52 \pm 0.78 \text{(stat)} \pm 0.92 \text{(syst)}$)%. This value is consistent with the MicroBooNE simulation prediction of ($9.70 \pm 0.65 \text{(stat)}$)% at the $1.6 σ$ level. This study represents the first ever measurement of LArTPC energy resolution at the MeV scale and provides a pathway for monoenergetic energy calibrations in future experiments using LArTPC detectors.

Abratenko, P. [Tufts U.]↗

Development of the first relativistic electron loss probe with pitch and energy resolution in the DIII-D tokamak

A relativistic electron probe has been developed in the DIII-D tokamak, capable of simultaneously resolving pitch angles and energies of runaway electrons (REs) for the first time. Due to the relativistic speeds of REs, their gyro-orbit size becomes comparable to those of fast deuterium with energies in the tens of keV range. This allows for the measurement of RE strike images on a phosphor plane, with their orbits being deflected by the Lorentz force as they pass through a pinhole aperture. The strike positions correspond to the energies and pitch of the incident REs. Monte Carlo N-Particle Transport Code has shown that an ultra-thin phosphor coating significantly reduces the energy deposition from γ-rays, while allowing a much greater deposition from REs, minimizing the background noise. Finally, the novel system, developed for the DIII-D tokamak, is expected to provide unprecedented insights into the phase-space dynamics of REs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Delving into the depths of NGC 3783 with XRISM II. Cross-calibration of X-ray instruments used in the large, multi-mission observational campaign

Context. Accurate X-ray spectroscopic measurements are fundamental for deriving basic physical parameters of the most abundant baryon components in the Universe. The plethora of X-ray observatories currently operational enables a panchromatic view of the high-energy emission of celestial sources. However, uncertainties in the energy-dependent calibration of the instrument transfer functions (e.g. the effective area, energy redistribution, or gain) can limit - and historically, did limit - the accuracy of X-ray spectroscopic measurements. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign.

Active Galactic Nuclei, individual: NGC 3783↗

First-Principles insights into group-V impurities and their impact on germanium detector performance

The outstanding properties of high-purity germanium (HPGe) detectors, such as excellent energy resolution, high energy sensitivity, and a low background-to-signal ratio, make them essential and ideal candidates for detecting particle signatures in nuclear processes such as neutrino-less double beta decay (0νββ). However, the presence of defects and impurities in HPGe crystals can lead to charge trapping, which affects carrier mobility and results in significant energy resolution degradation. In this work, we employ density functional theory with a hybrid functional to study the energetics of possible point defects in Ge. Our findings indicate that group-V impurities form more readily in Ge compared to vacancy and interstitial of Ge. Unlike N dopants, which yield deep trap states, P, As, and Sb create shallow traps close to the conduction band edge of Ge. Furthermore, we predict that group-V defects can condense into defect complexes with Ge vacancies. These vacancy-impurity complexes form deep traps in Ge, similar to Ge vacancies, suggesting that both vacancies and vacancy-impurity complexes contribute to charge trapping in these detectors, thereby diminishing their performance.

36 MATERIALS SCIENCE↗

Discovery of Dielectric Response and Forces in Sub-Nanoscale Objects (Final Technical Report)

This is the final technical report for DOE Award DE-SC0005132 entitled “Discovery of Dielectric Response and Forces in Sub-Nanoscale Objects.” This award originated on August 15, 2010 with Principle Investigator Prof. Phil Batson of Rutgers, The State University of New Jersey. Prof. Batson transitioned to Professor Emeritus status on January 31, 2023. At that time PI status was transferred to Prof. Robert Bartynski of the Department of Physics and Astronomy at Rutgers, The State University of New Jersey, and Director of the Rutgers Laboratory for Surface Modification. The central theme of the research performed under this award is develop and refine a NION aberration-corrected Scanning Transmission Electron Microscope to attain atomic spatial resolution and sub 10meV energy resolution in electron energy loss spectroscopy (EELS) performed on the transmitted electron beam. These capabilities allow examination of the excitation properties (primarily plasmonic and vibrational [ie., phonons] of nanoscale objects when excited with a highly-localized (~ Angstrom-scale) high energy (~ 60 keV) electron beam. Direct excitations (i.e., the response to electrons impinging directly on the sample) as well as excitations in response to the dynamic electric (and magnetic!) fields of an aloof electron beam (i.e., a beam that is close to but displaced from the target) have been studied. Our experimental work has benefited greatly from close collaborations with theoretical colleagues, but at Rutgers and from around the world, providing a much more complete understanding of the observed phenomena and suggesting avenues for further study and practical applications. This report summarizes the technical and scientific achievements accomplished during the entire award period. More extensive details are available in the Progress Reports that have already been filed with the Department of Energy. The report is divided into six sections. The first four sections focus on exploring, developing and understanding several unique capabilities and phenomena discovered and accessible owing to the high spatial- and energy-resolution we have been able to achieve. The latter two sections focus on applications of the STEM’s novel capabilities to study atomic- and nanometer-scale properties of solids, as well as broader applications to advanced and bio-materials.

47 OTHER INSTRUMENTATION↗

Hyperspectral x-ray imaging mapping capabilities for nuclear forensics

Nuclear forensics relies on the integration of complementary signatures to constrain the origins and history of materials. Outcomes benefit from the timeliness and precision of the disparate methods that form typical analysis chains. Sample forms are often either minute in quantity or contain signatures like morphology or composition heterogeneity encoded on a microscale, so many analysis techniques focus on resolving signatures on ever-smaller length scales. The new hyperspectral x-ray imaging (HXI) instrument developed at Los Alamos National Laboratory seeks to improve the information available from scanning electron microscopy (SEM) x-ray spectrum analysis through superior spectral energy resolution vs. typical energy dispersive spectroscopy (EDS) systems in common use in nuclear forensics and other microanalysis fields. Based on arrays of transition-edge sensor (TES) microcalorimeter detectors, this instrument achieves a typical energy resolution of 7 eV full-width at half-maximum (FWHM) at 2 keV, opening new possibilities in trace element detection/analysis and chemical state determination through spectral shape shifts. We present here some of the first applications of the HXI instrument to actinide samples and discuss potential maturation of this nascent technology for future analysis pipelines.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TinyTPC: A TEST STAND FOR LAr DOPING

TinyTPC is a small scale liquid-argon time projection chamber (LArTPC) that studies how photosensitive dopants can improve the energy resolution of low energy events in LArTPCs. Bench tests to resolve high voltage breakdown issues and to improve the low voltage system readout are described. Experimental data with a radioactive source of Th-228 for the calibration of the pixelated readout and the characterization of TinyTPC's energy resolution is explained. Provisional results from the addition of isobutylene (photosensitive dopant) and xenon (wavelength shifter) to liquid-argon (LAr) are also presented. Further steps to improve voltage system and enhance the data collection are discussed.

Rodriguez Thorne, Paloma↗