Search NASA⌕ Search

SEARCH · Search NASA

Results for “Error functions.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Technical Note: Dose-volume histogram analysis in radiotherapy using the Gaussian error function

A mathematical model based on the Gaussian error and complementary error functions was proposed to describe the cumulative dose-volume histogram (cDVH) for a region of interest in a radiotherapy plan. Parameters in the model (a, b, c) are related to different characteristics of the shape of a cDVH curve such as the maximum relative volume, slope and position of a curve drop off, respectively. A prostate phantom model containing a prostate, the seminal vesicle, bladder and rectum with cylindrical organ geometries was used to demonstrate the effect of interfraction prostate motion on the cDVH based on this error function model. The prostate phantom model was planned using a five-beam intensity modulated radiotherapy (IMRT), and a four-field box (4FB), technique with the clinical target volume (CTV) shifted in different directions from the center. In the case of the CTV moving out of the planning target volume (PTV), that is, the margin between the CTV and PTV is underestimated, parameter c (related to position of curve drop off) in the 4FB plan and parameters b (related to the slope of curve) and c in the IMRT plan vary significantly with CTV displacement. This shows that variation of the cDVH is present in the 4FB plan and such variation is more serious in the IMRT plan. These variations of cDVHs for 4FB and IMRT are due to the different dose gradients at the CTV edges in the anterior and posterior directions for the 4FB and IMRT plan. It is believed that a mathematical representation of the dose-volume relationship provides another viewpoint from which to illustrate problems with radiotherapy delivery such as internal organ motion that affect the dose distribution in a treatment plan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-385: Evaluation of DVH Change for PTV Due to Patient Weight Loss in Prostate VMAT Using Gaussian Error Function

Purpose: We proposed a method to predict the change of dose-volume histogram (DVH) for PTV due to patient weight loss in prostate volumetric modulated arc therapy (VMAT). This method is based on a pre-calculated patient dataset and DVH curve fitting using the Gaussian error function (GEF). Methods: Pre-calculated dose-volume data from patients having weight loss in prostate VMAT was employed to predict the change of PTV coverage due to reduced depth in external contour. The effect of patient weight loss in treatment was described by a prostate dose-volume factor (PDVF), which was evaluated by the prostate PTV. Along with the PDVF, the GEF was used to fit into the DVH curve for the PTV. To predict a new DVH due to weight loss, parameters from the GEF describing the shape of DVH curve were determined. Since the parameters were related to the PDVF as per the specific reduced depth, we could first predict the PDVF at a reduced depth based on the prostate size from the pre-calculated dataset. Then parameters of the GEF could be determined from the PDVF to plot the new DVH for the PTV corresponding to the reduced depth. Results: A MATLAB program was built basing on the patient dataset with different prostate sizes. We input data of the prostate size and reduced depth of the patient into the program. The program then calculated the PDVF and DVH for the PTV considering the patient weight loss. The program was verified by different patient cases with various reduced depths. Conclusion: Our method can estimate the change of DVH for the PTV due to patient weight loss quickly without CT rescan and replan. This would help the radiation staff to predict the change of PTV coverage, when patient’s external contour reduced in prostate VMAT.

60 APPLIED LIFE SCIENCES↗

SU-E-J-164: Estimation of DVH Variation for PTV Due to Interfraction Organ Motion in Prostate VMAT Using Gaussian Error Function

Purpose: We developed a method to predict the change of DVH for PTV due to interfraction organ motion in prostate VMAT without repeating the CT scan and treatment planning. The method is based on a pre-calculated patient database with DVH curves of PTV modelled by the Gaussian error function (GEF). Methods: For a group of 30 patients with different prostate sizes, their VMAT plans were recalculated by shifting their PTVs 1 cm with 10 increments in the anterior-posterior, left-right and superior-inferior directions. The DVH curve of PTV in each replan was then fitted by the GEF to determine parameters describing the shape of curve. Information of parameters, varying with the DVH change due to prostate motion for different prostate sizes, was analyzed and stored in a database of a program written by MATLAB. Results: To predict a new DVH for PTV due to prostate interfraction motion, prostate size and shift distance with direction were input to the program. Parameters modelling the DVH for PTV were determined based on the pre-calculated patient dataset. From the new parameters, DVH curves of PTVs with and without considering the prostate motion were plotted for comparison. The program was verified with different prostate cases involving interfraction prostate shifts and replans. Conclusion: Variation of DVH for PTV in prostate VMAT can be predicted using a pre-calculated patient database with DVH curve fitting. The computing time is fast because CT rescan and replan are not required. This quick DVH estimation can help radiation staff to determine if the changed PTV coverage due to prostate shift is tolerable in the treatment. However, it should be noted that the program can only consider prostate interfraction motions along three axes, and is restricted to prostate VMAT plan using the same plan script in the treatment planning system.

60 APPLIED LIFE SCIENCES↗

Density-functional errors in ionization potential with increasing system size

This work investigates the effects of molecular size on the accuracy of density-functional ionization potentials for a set of 28 hydrocarbons, including series of alkanes, alkenes, and oligoacenes. As the system size increases, delocalization error introduces a systematic underestimation of the ionization potential, which is rationalized by considering the fractional-charge behavior of the electronic energies. The computation of the ionization potential with many density-functional approximations is not size-extensive due to excessive delocalization of the incipient positive charge. While inclusion of exact exchange reduces the observed errors, system-specific tuning of long-range corrected functionals does not generally improve accuracy. These results emphasize that good performance of a functional for small molecules is not necessarily transferable to larger systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uncertainty analysis technique for OMEGA Dante measurements

The Dante is an 18 channel x-ray filtered diode array which records the spectrally and temporally resolved radiation flux from various targets (e.g., hohlraums, etc.) at x-ray energies between 50 eV and 10 keV. It is a main diagnostic installed on the OMEGA laser facility at the Laboratory for Laser Energetics, University of Rochester. The absolute flux is determined from the photometric calibration of the x-ray diodes, filters and mirrors, and an unfold algorithm. Understanding the errors on this absolute measurement is critical for understanding hohlraum energetic physics. We present a new method for quantifying the uncertainties on the determined flux using a Monte Carlo parameter variation technique. This technique combines the uncertainties in both the unfold algorithm and the error from the absolute calibration of each channel into a one sigma Gaussian error function. One thousand test voltage sets are created using these error functions and processed by the unfold algorithm to produce individual spectra and fluxes. Statistical methods are applied to the resultant set of fluxes to estimate error bars on the measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An inverse problem strategy based on forward model evaluations: Gradient-based optimization without adjoint solves

This study presents a new nonlinear programming formulation for the solution of inverse problems. First, a general inverse problem formulation based on the compliance error functional is presented. The proposed error functional enables the computation of the Lagrange multipliers, and thus the first order derivative information, at the expense of just one model evaluation. Therefore, the calculation of the Lagrange multipliers does not require the solution of the computationally intensive adjoint problem. This leads to significant speedups for large-scale, gradient-based inverse problems.

42 ENGINEERING↗

SU-E-T-432: A Rapid and Comprehensive Procedure for Daily Proton QA

Purpose: The objective is to develop a rapid and comprehensive daily QA procedure implemented at the S. Lee Kling Proton Therapy Center at Barnes-Jewish Hospital. Methods: A scribed phantom with imbedded fiducials is used for checking lasers accuracy followed by couch isocentricity and for X-ray imaging congruence with isocenter. A Daily QA3 device (Sun Nuclear, FL) was used to check output, range and profiles. Five chambers in the central region possess various build-ups. After converting the thickness of the inherent build-ups into water equivalent thickness (WET) for proton, range of any beam can be checked with additional build-up on the Daily QA3 device. In our procedure, 3 beams from 3 bands (large, small and deep) with nominal range of 20 cm are checked daily. 17cm plastic water with WET of 16.92cm are used as additional build-up so that four chambers sit on the SOBP plateau at various depths and one sit on the distal fall off. Reading from the five chambers are fitted to an error function that has been parameterized to match the SOBP with the same nominal range. Shifting of the error function to maximize the correlation between measurements and the error function is deemed as the range shift from the nominal value. Results: We have found couch isocentricity maintained over 180 degrees. Imaging system exhibits accuracy in regard to imaging and mechanical isocenters. Ranges are within 1mm accuracy from measurements in water tank, and sensitive to change of sub-millimeter. Data acquired since the start of operation show outputs, profiles and range stay within 1% or 1mm from baselines. The whole procedure takes about 40 minutes. Conclusion: Taking advantage of the design of Daily QA3 device turns the device originally designed for photon and electron into a comprehensive and rapid tool for proton daily QA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solution of D dimensional Dirac equation for hyperbolic tangent potential using NU method and its application in material properties

The analytical solution of D-dimensional Dirac equation for hyperbolic tangent potential is investigated using Nikiforov-Uvarov method. In the case of spin symmetry the D dimensional Dirac equation reduces to the D dimensional Schrodinger equation. The D dimensional relativistic energy spectra are obtained from D dimensional relativistic energy eigen value equation by using Mat Lab software. The corresponding D dimensional radial wave functions are formulated in the form of generalized Jacobi polynomials. The thermodynamically properties of materials are generated from the non-relativistic energy eigen-values in the classical limit. In the non-relativistic limit, the relativistic energy equation reduces to the non-relativistic energy. The thermal quantities of the system, partition function and specific heat, are expressed in terms of error function and imaginary error function which are numerically calculated using Mat Lab software.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using the Diffusion Equation to Predict CST Resin Breakthroughs - 19051

The crystalline silicotitanate, CST, resin manufactured by UOP Honeywell is well-suited for single-use decontamination of caustic liquid wastes at Hanford and Savannah River Sites. There are many measurements of column loading and breakthrough for CST resin decontamination of Cs-137 in various Hanford and SRS waste simulants. Such measurements provide a very good basis for estimating CST resin demand and these more refined predictions make the CST column loading as efficient as possible given the very expensive CST resin. Although there are a variety of tools for predicting chromatographic resin column performance, [1-4], there is a particularly useful method that is suitable as a simple spreadsheet model [4]. This spreadsheet model is an analytical error function for the mass transfer zone (mtz) diffusion width in resin columns and is well-suited for resin breakthrough and column loading. This paper describes just such an error function spreadsheet model and how well the error function agrees with more traditional models and fits the observed small scale breakthrough curves for CST that can then better predict large scale column loading efficiency. The very high sorption of Cs onto CST tends to be slower than that of other lower sorption resins and as a result of the slow CST kinetics, there is also a marked asymmetry in many CST breakthrough curves. The CST breakthrough asymmetry is largely due to the distribution of CST particle sizes because smaller particles sorb much faster than larger particles. It is then the smaller particles that determine the leading mtz at a decontamination factor of 1,000 breakthrough and therefore the decontamination efficiency for a given loading. The larger CST particles correspondingly determine the tailing mtz width and therefore the overall loading efficiency and it is important to model both leading and tailing mtz widths to best optimize CST for a particular Cs-137 decontamination application. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nodal variational principle for excited states

It is proven that the exact excited-state wave function and energy may be obtained by minimizing the energy expectation value of trial wave functions that are constrained only to have the correct nodes of the state of interest. This excited-state nodal minimum principle has the advantage that it requires neither minimization with the constraint of wave-function orthogonality to all lower eigenstates nor the antisymmetry of the trial wave functions. It is also found that the minimization over the entire space can be partitioned into several interconnected minimizations within the individual nodal regions, and the exact excited-state energy may be obtained by a minimization in just one or several of these nodal regions. For the proofs of the theorem, it is observed that the many-electron eigenfunction (excited state as well as ground state), restricted to a nodal region, is equivalent to a ground-state wave function of one electron in a higher-dimensional space; and, alternatively, an explicit excited-state energy variational expression is utilized by generalizing the Jacobi method of multiplicative variation. In corollaries, error functions are constructed for cases for which the nodes are not necessarily exact. The exact nodes minimize the energy error functions with respect to nodal variations. In conclusion, simple numerical illustrations of the error functions are presented.

74 ATOMIC AND MOLECULAR PHYSICS↗

Kinetic modelling for zinc (II) ions biosorption onto Luffa cylindrica

The biosorption of Zinc (II) ions onto a biomaterial - Luffa cylindrica has been studied. This biomaterial was characterized by elemental analysis, surface area, pore size distribution, scanning electron microscopy, and the biomaterial before and after sorption, was characterized by Fourier Transform Infra Red (FTIR) spectrometer. The kinetic nonlinear models fitted were Pseudo-first order, Pseudo-second order and Intra-particle diffusion. A comparison of non-linear regression method in selecting the kinetic model was made. Four error functions, namely coefficient of determination (R{sup 2}), hybrid fractional error function (HYBRID), average relative error (ARE), and sum of the errors squared (ERRSQ), were used to predict the parameters of the kinetic models. The strength of this study is that a biomaterial with wide distribution particularly in the tropical world and which occurs as waste material could be put into effective utilization as a biosorbent to address a crucial environmental problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Halogen Thermochemistry Assessed with Density Functional Theory: Systematic Errors, Swift Corrections and Effects on Electrochemistry

Abstract Despite its sizable errors, density functional theory (DFT) is extensively used to evaluate thermochemical properties of gases, liquids and their interfaces with solids. As numerous halogen‐containing compounds appear as reactants, products and/or electrolytes in electrochemical reactions, and ionic effects are currently an active area of research, it is important to evaluate the accuracy of DFT for halogen thermochemistry. Herein, we assess the formation energies of interhalogens, hydrogen halides, diatomic and atomic halogens and their ions using six widespread functionals at the GGA, meta‐GGA and hybrid levels. We observe that DFT errors with respect to experiments are correlated with the electronegativity of the species and there are systematic trends across functionals, such that swift corrections were devised. Specifically, the average of the mean absolute errors for the six functionals decreased from 0.19 eV before the corrections to 0.08 eV after them. Besides, the overall maximum absolute error (MAX) decreased from 0.76 to 0.44 eV and the average of the MAXs decreased from 0.51 to 0.24 eV. Finally, we illustrate the qualitative and quantitative impact of gas‐phase errors on the predictions of surface Pourbaix diagrams.

Chemistry↗

A new computational approach for the solutions of generalized pantograph-delay differential equations

In this study, a new computational approach is presented to solve the generalized pantograph-delay differential equations (PDDEs). The solutions obtained by our scheme represent by a linear combination of a special kind of basis functions, and can be deduced in a straightforward manner. Firstly, using the least squares approximation method and the Lagrange-multiplier method, the given PDDE is converted to a linear system of algebraic equations, and those unknown coefficients of the solution of the problem are determined by solving this linear system. Secondly, a PDDE related to the error function of the approximate solution is constructed based on the residual error function technique, and error estimation is presented for the suggested method. The convergence of the approximate solution is proved. Several numerical examples are given to demonstrate the accuracy and efficiency. Comparisons are made between the proposed method and other existing methods.

97 MATHEMATICS AND COMPUTING↗

Three filters for visualization of phase objects with large variations of phase gradients

We propose three amplitude filters for visualization of phase objects. They interact with the spectra of pure-phase objects in the frequency plane and are based on tangent and error functions as well as antisymmetric combination of square roots. The error function is a normalized form of the Gaussian function. The antisymmetric square-root filter is composed of two square-root filters to widen its spatial frequency spectral range. Their advantage over other known amplitude frequency-domain filters, such as linear or square-root graded ones, is that they allow high-contrast visualization of objects with large variations of phase gradients.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Solution of D dimensional Dirac equation for coulombic potential using NU method and its thermodynamics properties

The analytical solution of Ddimensional Dirac equation for Coulombic potential is investigated using Nikiforov-Uvarov method. The D dimensional relativistic energy spectra are obtained from relativistic energy eigenvalue equation by using Mat Lab software.The corresponding D dimensional radial wave functions are formulated in the form of generalized Jacobi and Laguerre Polynomials. In the non-relativistic limit, the relativistic energy equation reduces to the non-relativistic energy which will be applied to determine some thermodynamical properties of the system. The thermodynamical properties of the system are expressed in terms of error function and imaginary error function.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗