Search NASASearch

SEARCH · Search NASA

Results for “Evaporation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Effect of Variable Gravity on Evaporation of Binary Fluids in a Capillary Pore Evaporator

The research project focuses on experimental investigation of the capillary-pumped evaporative heat transfer phenomenon. The objective is to examine whether the heat transfer and stability of a heated meniscus in a capillary pore can be enhanced by adding trace amounts of a non-volatile solute to a solvent and to understand the changes that occur. The experimental setup consists of a single pore evaporator connected to a reservoir which supplies liquid to the evaporator. In addition to the experiments of capillary-pumped evaporation, a parallel experimental study has been conducted to systematically investigate the effects of gravity as well as the effects of bulk composition on the heat transfer characteristics of evaporating binary thin films near the contact line region along an inclined heated surface. To investigate the buoyancy effects on evaporation along an inclined heated surface, the angle of inclination from a horizontal plane was varied fro 15 C to 90 C. An optimum concentration between 0.5% and 1% decane in pentane/decane solutions has been demonstrated at different angles of inclination. Improved heat transfer was found for the geometry with the smallest angle of inclination of 15 degrees. In addition, flow visualization has revealed that at low inclination angles effective heat transfer takes place primarily due to an extension of the thin film near the contact line. At these low inclination angles, the optimum concentration is associated with enhanced wetting characteristics and reduced thermocapillary stresses along the interface.

Girgis, Morris M.

Evaporator Development for an Evaporative Heat Pipe System

As fossil fuel resources continue to deplete, research for alternate power sources continues to develop. One of these alternate technologies is fuel cells. They are a practical fuel source able to provide significant amounts of power for applications from laptops to automobiles and their only byproduct is water. However, although this technology is over a century old and NASA has been working with it since the early 1960 s there is still room for improvement. The research I am involved in at NASA's Glenn Research Center is focusing on what is called a regenerative fuel cell system. The unique characteristic of this type of system is that it used an outside power source to create electrolysis of the water it produces and it then reuses the hydrogen and oxygen to continue producing power. The advantage of this type of system is that, for example, on space missions it can use solar power to recharge its gas supplies between periods when the object being orbited blocks out the sun. This particular system however is far from completion. This is because of the many components that are required to make up a fuel cell that need to be tested individually. The specific part of the system that is being worked on this summer of 2004 is the cooling system. The fuel cell stack, that is the part that actually creates the power, also produces a lot of heat. When not properly cooled, it has been known to cause fires which, needless to say are not conducive to the type of power that is trying to be created. In order to cool the fuel cell stack in this system we are developing a heat pipe cooling system. One of the main components of a heat pipe cooling system is what is known as the evaporator, and that is what happens to be the part of the system we are developing this summer. In most heat pipe systems the evaporator is a tube in which the working fluid is cooled and then re-circulated through the system to absorb more heat energy from the fuel cell stack. For this system, instead of a tube, the evaporator is made up of a stack-up of screen material and absorbent membranes inside a stainless steel shell and held together by a film adhesive and epoxy. There is an initial design for this flat plate evaporator, however is has not yet been made. The components of the stack-up are known, so all testing is focused on how it will all go together. This includes finding an appropriate epoxy to make the evaporator conductive all the way through and finding a way to hold the required tight tolerances as the stainless steel outer shell is put together. By doing the tests on smaller samples of the stack-ups and then testing the fill size component, the final flat plate evaporator will reach its final design so that research can continue on other parts of the regenerative fue1 cell system, and another step in the improvement of fue1 cell technology can be made.

Peters, Leigh C.

Spacesuit Water Membrane Evaporator; An Enhanced Evaporative Cooling Systems for the Advanced Extravehicular Mobility Unit Portable Life Support System

Spacesuit Water Membrane Evaporator - Baseline heat rejection technology for the Portable Life Support System of the Advanced EMU center dot Replaces sublimator in the current EMU center dot Contamination insensitive center dot Can work with Lithium Chloride Absorber Radiator in Spacesuit Evaporator Absorber Radiator (SEAR) to reject heat and reuse evaporated water The Spacesuit Water Membrane Evaporator (SWME) is being developed to replace the sublimator for future generation spacesuits. Water in LCVG absorbs body heat while circulating center dot Warm water pumped through SWME center dot SWME evaporates water vapor, while maintaining liquid water - Cools water center dot Cooled water is then recirculated through LCVG. center dot LCVG water lost due to evaporation (cooling) is replaced from feedwater The Independent TCV Manifold reduces design complexity and manufacturing difficulty of the SWME End Cap. center dot The offset motor for the new BPV reduces the volume profile of the SWME by laying the motor flat on the End Cap alongside the TCV.

Bue, Grant C.

Direct Prelithiation of Silicon-Based Composite Electrodes via Island-like Thermal Evaporation

Irreversible losses of Li during solid electrolyte interface (SEI) conditioning is a key contributor to the lower specific capacities observed in silicon-containing Li-ion batteries. Herein, thermal evaporation of between 1 and 20 µm of Li onto Si-based composite anodes has been investigated as a prelithiation method to account for such losses. To account for mechanical strain caused by Li-Si alloying during the deposition, a stainless-steel mesh is applied to the electrodes before prelithiation to form “island-like” deposition on the electrode surface. The open circuit potential was also found to decrease as a function of increased Li evaporation, consistent with the potentials of electrochemically prepared LixSi alloys. Prelithiating to account for irreversible Li losses to SEI formation resulted in full cells with a 15.8% increase in initial coulombic efficiency and a 47.8% reduction in irreversible capacity loss after SEI formation cycling. Subsequent C/3 cycling showed up to a 62.9% increase in specific capacity in prelithiated cells. X-ray photoelectron spectroscopy (XPS) revealed differences in the SEI composition that was formed by electrochemical cycling and reactively formed in prelithiated cells upon exposure to Gen2 + 3% FEC electrolyte. The reactively formed SEI from the spontaneous reaction with lithiated silicon was carbonate-rich while the electrochemical SEI formation showed significantly more LiPFx species, which could play a role in overall cycling performance.

Musgrove, Amanda

Thermal and Hydrologic Signatures of Soil Controls on Evaporation: A Combined Energy and Water Balance Approach with Implications for Remote Sensing of Evaporation

The overall goal of this research is to examine the feasibility of applying a newly developed diagnostic model of soil water evaporation to large land areas using remotely sensed input parameters. The model estimates the rate of soil evaporation during periods when it is limited by the net transport resulting from competing effects of capillary rise and drainage. The critical soil hydraulic properties are implicitly estimated via the intensity and duration of the first stage (energy limited) evaporation, removing a major obstacle in the remote estimation of evaporation over large areas. This duration, or "time to drying" (t(sub d)), is revealed through three signatures detectable in time series of remote sensing variables. The first is a break in soil albedo that occurs as a small vapor transmission zone develops near the surface. The second is a break in either surface to air temperature differences or in the diurnal surface temperature range, both of which indicate increased sensible heat flux (and/or storage) required to balance the decrease in latent heat flux. The third is a break in the temporal pattern of near surface soil moisture. Soil moisture tends to decrease rapidly during stage 1 drying (as water is removed from storage), and then become more or less constant during soil limited, or "stage 2" drying (as water is merely transmitted from deeper soil storage). The research tasks address: (1) improvements in model structure, including extensions to transpiration and aggregation over spatially variable soil and topographic landscape attributes; and (2) applications of the model using remotely sensed input parameters.

Salvucci, Guido D.

Thermal and Hydrologic Signatures of Soil Controls on Evaporation: A Combined Energy and Water Balance Approach with Implications for Remote Sensing of Evaporation

The overall goal of this research is to examine the feasibility of applying a newly developed diagnostic model of soil water evaporation to large land areas using remotely sensed input parameters. The model estimates the rate of soil evaporation during periods when it is limited by the net transport resulting from competing effects of capillary rise and drainage. The critical soil hydraulic properties are implicitly estimated via the intensity and duration of the first stage (energy limited) evaporation, removing a major obstacle in the remote estimation of evaporation over large areas. This duration, or 'time to drying' (t(sub d)) is revealed through three signatures detectable in time series of remote sensing variables. The first is a break in soil albedo that occurs as a small vapor transmission zone develops near the surface. The second is a break in either surface to air temperature differences or in the diurnal surface temperature range, both of which indicate increased sensible heat flux (and/or storage) required to balance the decrease in latent heat flux. The third is a break in the temporal pattern of near surface soil moisture. Soil moisture tends to decrease rapidly during stage I drying (as water is removed from storage), and then become more or less constant during soil limited, or 'stage II' drying (as water is merely transmitted from deeper soil storage). The research tasks address: (1) improvements in model structure, including extensions to transpiration and aggregation over spatially variable soil and topographic landscape attributes; and (2) applications of the model using remotely sensed input parameters.

Salvucci, Guido D.

Reduced Volume Prototype Spacesuit Water Membrane Evaporator; A Next-Generation Evaporative Cooling System for the Advanced Extravehicular Mobility Unit Portable Life Support System

Development of the Advanced Extravehicular Mobility Unit (AEMU) portable life support subsystem (PLSS) is currently under way at NASA Johnson Space Center. The AEMU PLSS features a new evaporative cooling system, the reduced volume prototype (RVP) spacesuit water membrane evaporator (SWME). The RVP SWME is the third generation of hollow fiber SWME hardware. Like its predecessors, RVP SWME provides nominal crew member and electronics cooling by flowing water through porous hollow fibers. Water vapor escapes through the hollow fiber pores, thereby cooling the liquid water that remains inside of the fibers. This cooled water is then recirculated to remove heat from the crew member and PLSS electronics. Major design improvements, including a 36% reduction in volume, reduced weight, and a more flight-like backpressure valve, facilitate the packaging of RVP SWME in the AEMU PLSS envelope. The development of these evaporative cooling systems will contribute to a more robust and comprehensive AEMU PLSS.

Makinen, Janice V.

Spacesuit Water Membrane Evaporator; An Enhanced Evaporative Cooling System for the Advanced Extravehicular Mobility Unit Portable Life Support System

Development of the Advanced Extravehicular Mobility Unit (AEMU) portable life support subsystem (PLSS) is currently under way at NASA Johnson Space Center. The AEMU PLSS features a new evaporative cooling system, the Generation 4 Spacesuit Water Membrane Evaporator (Gen4 SWME). The SWME offers several advantages when compared with prior crewmember cooling technologies, including the ability to reject heat at increased atmospheric pressures, reduced loop infrastructure, and higher tolerance to fouling. Like its predecessors, Gen4 SWME provides nominal crew member and electronics cooling by flowing water through porous hollow fibers. Water vapor escapes through the hollow fiber pores, thereby cooling the liquid water that remains inside of the fibers. This cooled water is then recirculated to remove heat from the crew member and PLSS electronics. Test results from the backup cooling system which is based on a similar design and the subject of a companion paper, suggested that further volume reductions could be achieved through fiber density optimization. Testing was performed with four fiber bundle configurations ranging from 35,850 fibers to 41,180 fibers. The optimal configuration reduced the Gen4 SWME envelope volume by 15% from that of Gen3 while dramatically increasing the performance margin of the system. A rectangular block design was chosen over the Gen3 cylindrical design, for packaging configurations within the AEMU PLSS envelope. Several important innovations were made in the redesign of the backpressure valve which is used to control evaporation. A twin-port pivot concept was selected from among three low profile valve designs for superior robustness, control and packaging. The backpressure valve motor, the thermal control valve, delta pressure sensors and temperature sensors were incorporated into the manifold endcaps, also for packaging considerations. Flight-like materials including a titanium housing were used for all components. Performance testing of the Gen4 SWME is underway.

Bue, Grant C.

Optimization of Delignified Wood Rods for Interfacial Solar Evaporation

Interfacial solar evaporation using three-dimensional evaporator materials has shown promise to achieve high evaporation rates exceeding the photothermal limit for water treatment and resource recovery processes. However, challenges remain in optimizing the material geometry to balance the vertical capillary uptake of water and the rate of evaporation to achieve both stable and high evaporation rates. Delignified wood can serve as a highly porous and hydrophilic substrate material to achieve high evaporation rates. In this work, we designed a suspended biochar-coated delignified wood rod evaporator and investigated the influence of its geometric parameters on its evaporation performance. The height of the evaporator exposed to air for evaporation was observed to be an important parameter in governing the evaporation rate, as shorter evaporators limited the available surface area for evaporation, but taller evaporators could not achieve sufficient rates of capillary uptake to maintain stable evaporation rates over 24 h under 1-sun illumination (1 kW m –2 ). In conclusion, the exposed height of the evaporator was optimized to achieve an average hourly evaporation rate of 3.05 ± 0.23 kg m –2 h –1 , which could be maintained in saline solutions containing up to 5 wt % NaCl.

Coating materials

Trends and meteorological drivers of extreme daily reservoir evaporation events in the western United States

Extreme daily evaporation from reservoir surfaces can lead to significant short-term water losses, affecting water quality, water supply, and reservoir operation strategies. Historical trends in daily reservoir evaporation events have eluded the scientific and operational communities, largely due to a lack of long-term, consistent data record. This study quantifies trends in extreme daily reservoir evaporation events at 165 major reservoirs located in the western U.S. Here, we use the place-based energy balance and aerodynamic Daily Lake Evaporation Model (DLEM) driven by multiple meteorological data products (RTMA, gridMET, Daymet) to estimate daily evaporation rates at these reservoirs from 1981 to 2022. The results—while are based on different meteorological forcing datasets—consistently indicate that the California, Lower Colorado, and Rio Grande hydrologic regions are more prone to higher daily evaporation extremes. Compared to the rest of western U.S, these three regions also experience a more pronounced increasing trend in the annual maximum daily evaporation rate, at about 0.3 mm day -1 decade -1 during 1981-2022. The results show that heat and dryness are the main drivers to the increasing trend of extreme evaporation, while extreme wind speed is the primary contributor to exceptionally high daily evaporation events across all regions. This phenomenon is particularly prominent in the arid Lower Colorado region, but less significant in the cold and humid Pacific Northwest region. We also find that the correlation between extreme wind speed and extreme evaporation degrades as the time scale increases from daily, to monthly and seasonal. Our findings have strong implications for the pattern and distribution of extreme evaporation events at the western U.S. reservoirs, and illustrate how various drivers influence extreme evaporation across different time scales.

13 HYDRO ENERGY

Thermal performance of a multi-evaporator loop heat pipe with thermal masses and thermal electrical coolers

This paper describes thermal performance of a loop heat pipe (LHP) with two evaporators and two condensers in ambient testing. Each evaporator has an outer diameter of 15mm and a length of 76mm, and has an integral compensation chamber (CC). An aluminum mass of 500 grams is attached to each evaporator to simulate the instrument mass. A thermal electric cooler (TEC) is installed on each CC to provide heating as well as cooling for CC temperature control. A flow regulator is installed in the condenser section to prevent vapor from going back to the evaporators in the event that one of condenser is fully utilized. Ammonia was used ad the working fluid. Tests conducted included start-up, power cycle, heat load sharing, sink temperature cycle, operating temperature control with TECs, and capillary limit tests. Experimental data showed that the loop could start with a heat load of less than 1OW even with added thermal masses. The loop operated stably with even and uneven evaporator heat loads, and even and uneven condenser sink temperatures. The operating temperature could be controlled within +/-0.5K of the set point temperature using either or both TECs, and the required TEC control heater power was less than 2W under most test conditions. Heat load sharing between the two evaporators was also successfully demonstrated. The loop had a heat transport capability of 120W to 140W, and could recover from a dry-out when the heat load was reduced. The 500-gram aluminum mass on each evaporator had a negligible effect on the loop operation. Existing LHPs servicing the orbiting spacecraft have a single evaporator with an outer diameter of about 25mm. Important performance characteristics demonstrated by this LHP included: 1) Operation of an LHP with 15mm diameter evaporators; 2) Robustness and reliability of an LHP with multiple evaporators and multiple condensers under various test conditions; 3) Heat load sharing among LHP evaporators; 4) Effectiveness of TECs in controlling the LHP operating temperature; and 5) Effectiveness of the flow regulator in preventing vapor from going back the evaporators.

loop heat pipes

Evaporation in equilibrium, in vacuum, and in hydrogen gas

Evaporation experiments were conducted for SiO2 in three different conditions: in equilibrium, in vacuum, and in hydrogen gas. Evaporation rate in vacuum is about two orders of magnitude smaller than that in equilibrium, which is consistent with previous works. The rate in hydrogen gas changes depending on hydrogen pressure. The rate at 10 exp -7 bar of hydrogen pressure is as small as that of free evaporation, but at 10 exp -5 bar of hydrogen pressure it is larger than that in equilibrium. In equilibrium and in vacuum, the evaporation rate is limited by decomposition of SiO2 on the crystal surface, but it is limited by a diffusion process for evaporation in hydrogen gas. Therefore, evaporation rate of minerals in the solar nebula can be shown neither by that in equilibrium nor by that in vacuum. The maximum temperature of the solar nebula at the midplane at 2-3 AU where chondrites are believed to have originated is calculated to be as low as 150 K, 1500 K, or in between them. The temperature is, in any case, not high enough for total evaporation of the interstellar materials. Therefore, evaporation of interstellar materials is one of the most important processes for the origin and fractionation of solid materials. The fundamental process of evaporation of minerals has been intensively studied for these several years. Those experiments were carried out either in equilibrium or in vacuum; however, evaporation in the solar nebula is in hydrogen (and much smaller amount of helium) gas. In order to investigate evaporation rate and compositional (including isotopic) fractionation during evaporation, vaporization experiments for various minerals in various conditions are conducted. At first, SiO2 was adopted for a starting material, because thermochemical data and its nature of congruent vaporization are well known. Experiments were carried out in a vacuum furnace system.

Nagahara, Hiroko

Thermal Performance of a Multi-Evaporator Loop Heat Pipe with Thermal Masses and Thermoelectric Coolers

This paper describes thermal performance of a loop heat pipe (LHP) with two evaporators and two condensers in ambient testing. Each evaporator has an outer diameter of 15mm and a length of 76mm, and has an integral compensation chamber (CC). An aluminum mass of 500 grams is attached to each evaporator to simulate the instrument mass. A thermoelectric cooler (TEC) is installed on each CC to provide heating as well as cooling for CC temperature control. A flow regulator is installed in the condenser section to prevent vapor from going back to the evaporators in the event that one of the condensers is fully utilized. Ammonia was used as the working fluid. Tests conducted included start-up, power cycle, heat load sharing, sink temperature cycle, operating temperature control with TECs, and capillary limit tests. Experimental data showed that the loop could start with a heat load of less than 10W even with added thermal masses. The loop operated stably with even and uneven evaporator heat loads, and even and uneven condenser sink temperatures. The operating temperature could be controlled within +/- 0.5K of the set point temperature using either or both TECs, and the required TEC control heater power was less than 2W under most test conditions. Heat load sharing between the two evaporators was also successfully demonstrated. The loop had a heat transport capability of 120W to 140W, and could recover from a dry-out when the heat load was reduced. The 500-gram aluminum mass on each evaporator had a negligible effect on the loop operation. Existing LHPs servicing orbiting spacecraft have a single evaporator with an outer diameter of about 25mm. Important performance characteristics demonstrated by this LHP included: 1) Operation of an LHP with 15mm diameter evaporators; 2) Robustness and reliability of an LHP with multiple evaporators and multiple condensers under various test conditions; 3) Heat load sharing among LHP evaporators; 4) Effectiveness of TECs in controlling the LHP operating temperature; and 5 ) Effectiveness of the flow regulator in preventing vapor from going back the evaporators.

Ku, Jen-Tung

Optimization of lithium vapor box divertor evaporator location on NSTX-U using SOLPS-ITER

Commercial fusion reactors will be faced with extremely high divertor target heat fluxes that will require mitigation. Simulations of detachment in an NSTX-U scenario projected to have 92 MW/m 2 unmitigated peak target heat flux are presented, which reaches sub-10 MW/m 2 target heat flux using a highly dissipating lithium vapor box divertor design. The lithium vapor box is a detached divertor design which employs lithium vapor evaporation and condensation to contain lithium below the X-point. Previous SOLPS modeling has indicated a lithium vapor box can reduce the heat flux down to 10 MW/m 2 via simultaneous evaporation from the Private Flux Region (PFR) and the Common Flux Region (CFR) sides of the vapor box. It is found here that PFR evaporation has improved access to the separatrix leading to significantly more efficient power dissipation than CFR evaporation. Simulations of target evaporation with an evaporation distribution that is self-consistent with the temperature of a Capillary Porous System with Fast flowing liquid lithium (CPSF) could reach n Li / n e ~ 0.025-0.030 at the Last Closed Flux Surface (LCFS) depending on the liquid metal flow speeds and lithium sputtering yield, while PFR-side evaporation can reach acceptable heat fluxes with n Li / n e ~ 0.038 at the LCFS. However, PFR evaporator performance can be improved if the target is allowed to be hot enough such that it reflects lithium, reaching n Li / n e ~ 0.028 and reducing required lithium evaporation. Ultimately PFR evaporation and target evaporation are found to have similar ability to produce acceptable heat flux solutions with minimal upstream concentration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Surface Crust Formation Controls Evaporation Kinetics of Secondary Organic Aerosols

Gas-particle partitioning is critical for the evolution of secondary organic aerosols (SOA) in the atmosphere. SOA particles evaporate more slowly than expected at nearly size-independent rates, but the underlying mechanism remains controversial. Here, in this study, we apply kinetic multilayer modeling to simulate evaporation of α-pinene SOA, demonstrating that surface crust formation, emerging from accumulation of low-volatility compounds at the particle surface, leads to slow evaporation and reduced size dependence of the evaporation rate. While evaporation induced by decomposition of oligomers would naturally lead to size-independent evaporation rates, we observe and simulate nearly size-independent slow evaporation of polyethylene glycol mixture particles containing polymeric species that do not decompose, confirming the relevance of composition-dependent diffusivity for size-independent, slow evaporation. Slow evaporation of limonene SOA was also observed in environmental chamber experiments, and model simulations demonstrate strong surface crust formation with bulk diffusivity being depressed by up to 5 orders of magnitude compared to the inner bulk. We present experimental evidence using a surface-based mass spectrometry technique that shows that the particle surface becomes enriched in high molecular weight compounds upon evaporation of monomers. Our findings imply that viscous surface crusts may also limit the growth and chemical transformation of SOA particles, influencing their impacts on air quality and climate.

heterogeneous chemistry

The continuous similarity model of bulk soil-water evaporation

The continuous similarity model of evaporation is described. In it, evaporation is conceptualized as a two stage process. For an initially moist soil, evaporation is first climate limited, but later it becomes soil limited. During the latter stage, the evaporation rate is termed evaporability, and mathematically it is inversely proportional to the evaporation deficit. A functional approximation of the moisture distribution within the soil column is also included in the model. The model was tested using data from four experiments conducted near Phoenix, Arizona; and there was excellent agreement between the simulated and observed evaporation. The model also predicted the time of transition to the soil limited stage reasonably well. For one of the experiments, a third stage of evaporation, when vapor diffusion predominates, was observed. The occurrence of this stage was related to the decrease in moisture at the surface of the soil. The continuous similarity model does not account for vapor flow. The results show that climate, through the potential evaporation rate, has a strong influence on the time of transition to the soil limited stage. After this transition, however, bulk evaporation is independent of climate until the effects of vapor flow within the soil predominate.

Clapp, R. B.