Search NASASearch

SEARCH · Search NASA

Results for “Exhaust Capture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Natural Gas Combined Cycle Power Plants with Carbon Capture and Exhaust Gas Recycle

This is a presentation given at the 3rd International Conference on Energy and Environment. The presentation highlights analysis work conducted by NETL to assess the cost and performance for natural gas combined cycle (NGCC) power plants that incorporate solvent-based post combustion carbon dioxide (CO2) capture and exhaust gas recycle (EGR). Increasing the inlet CO2 concentration by EGR is expected to improve the efficiency of the capture system and reduce its cost, however the analysis results show that the cost improvement is minimal as is the cost of capture reduction.

Hackett, Gregory

Demonstration of the carbon capture with building make-up air unit

Building-integrated carbon capture technology has the potential to reduce the cost of CO 2 capture while improving indoor air quality (IAQ). To promote the adoption of CO 2 capture in a building environment, this study investigated the possibility of integrating carbon capture technology with an existing rooftop make-up air unit (MAU) system to trap CO 2 . Here, in this study, a modular compact CO 2 capture system containing amine-functionalized polymer fibers was examined. The system, which was installed at the exhaust of the MAU, captures CO 2 before it leaves the building to enter the atmosphere as a greenhouse gas. The demonstrated average amount of CO 2 captured was 1.1–1.4 mmol/g of adsorbent material. Techno-economic analysis (TEA) was further performed on the CO 2 capture system, considering material costs, energy costs, as well as transportation and regeneration costs. These results were then used to estimate the levelized cost per ton CO 2 captured (LCOC). To achieve LCOC below $\$$100/t-CO 2 , adsorbents should have working capacities of 4.9 t and 3 t-CO 2 /year for 5 years and 10 years of operation, respectively. In summary, this study highlights a viable path toward the decarbonization of the commercial buildings sector and provides quantitative performance and economic insight on the suitability of building-integrated carbon capture technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

A Life Cycle Analysis Framework for Point Source Capture Systems

NETL studies the costs and benefits of PSC for electricity, industry, and mobile applications. Mobile point source capture (MPSC) and storage applied to freight modes captures emissions directly from exhaust. This poster presents a framework for conducting LCA of PSC systems applied to heavy-duty trucks, freight trains, and marine vessels. The framework defines a wheels-to-storage (gate-to-grave) boundary, including energy demands (electricity, heat, and cooling requirements), solvent use and cycling, onboard system components, carbon storage in a saline aquifer, and upstream manufacturing impacts for equipment, with a suggested functional unit of 1 tonne-km. Potential data sources for analysis include material, energy, and operational data from Oak Ridge National Laboratory, GREET (Greenhouse gases, Regulated Emissions, and Energy use in Technologies) model, and scientific literature. The suggested analytical approach includes comparison to publicly available business-as-usual systems without capture across all modes of transportation, sensitivity to composition of the capture solvent, and sensitivity to capture rate variation, all of which would support a wholistic PSC business case analysis. For future consideration, analysis can be augmented with consideration of different sources of electricity (e.g., nuclear), fuel substitution, deploying supportive infrastructure such as pipeline offloading points, and downstream applications like enhanced oil recovery (EOR).

life cycle analysis (LCA)

Fluor Solvent Evaluation and Testing New Scope: Techno-economic Assessment of EEMPA Solvent for CO 2 Separations from Natural Gas Combined Cycle Power Plant

In this project, a techno-economic analysis (TEA) and sensitivity studies were conducted to assess the PNNL’s leading water-lean CO 2 capture solvent, EEMPA, for capture CO 2 from a natural gas combined cycle (NGCC) power plant at different levels of capture rate. Process models for the NGCC power plant, integrated with EEMPA carbon capture processes, were developed in Aspen Plus V14 using the most up-to-date property package for EEMPA-H 2 O-CO 2 system. The TEA evaluated EEMPA carbon capture process at normal capture rates (90%, 95% and 97%) against Case B32B (Cansolv) described in NETL Rev4a baseline report, and at higher capture rates aimed at achieving zero or negative emissions from the power plant (400 ppmv, 200 ppmv, and 100 ppmv CO 2 in exhaust gas), compared to typical Direct Air Capture (DAC) technologies. A manuscript was drafted for peer-reviewed publication. The results suggested that the carbon capture cost reaches a minimum of $\$$53.7/tonne CO 2 at 90% capture rate. Compared to Cansolv, one of the industrial benchmarks, EEMPA demonstrates 2-4% cost savings at capture rates up to 95%, but minimal savings at higher capture rate. The water lean-solvent system proves economically attractive for achieving moderate negative emissions (about 200 ppmv CO 2 in exhaust gas, and equivalent to 50% CO 2 removal from air) for NGCC flue gas, with marginal capture costs comparable to direct air capture (DAC) technologies. A sensitivity analysis results reveal that its economic advantage, unaffected by EEMPA price due to low solvent loss and degradation rate. However, the marginal carbon capture cost exceeds $\$$1,000/tonne CO 2 when transitioning from moderate to extreme negative emissions (100 ppmv CO 2 in exhaust gas), suggesting that water-lean solvents may not be economically competitive with other DAC technologies for removing more than 75% CO 2 from air. In addition, initial connection was established with Technology Center Mongstad (TCM) for a potential pilot testing proposal. However, detailed modeling and proposal preparation was not conducted due to the delay of non-disclosure agreement.

20 FOSSIL-FUELED POWER PLANTS

Simulations of the churning mode: Toroidally symmetric plasma convection and turbulence around the X-points in a snowflake divertor

Using a reduced MHD model, extended to include field-aligned thermal conduction, we present numerical simulations of the churning mode (CM): a toroidally symmetric, non-linear plasma vortex in the vicinity of the null points in a snowflake (SF) divertor [D. D. Ryutov et al., Phys. Scr. 89, 088002 (2014)]. Simulations are carried out across a range of inter-null separations, d xx ⁠, and inter-null orientations, θ⁠, primarily in conditions relevant to the MAST-U tokamak. We find that, when d xx is small, the CM induces additional transport across the X-points when β pm ≳8%, where β pm is the ratio of the plasma pressure in the null region to poloidal magnetic pressure at the midplane. This transport also increases approximately linearly as d xx is reduced. A diffusive model of this transport is shown to predict the total transport across the null points, where diffusion coefficients of up to ∼ 10 2 m 2 s −1 centered on a small region around the X-points are used. However, the CM also results in significant changes to the flux surfaces in the null region, which is not captured by this diffusive model. The changes in magnetic geometry mean the fractional exhaust power delivered to each divertor leg is highly sensitive to β pm ⁠, d xx ⁠, and θ⁠. For small values of θ⁠, the CM can induce a change in topology, redirecting exhaust power from a secondary divertor leg on the high field side to one on the low field side. Similar behavior is found in the fraction of exhaust power going to the inner and outer divertor. Such changes in the flux surfaces may not be captured by Grad–Shafranov solvers and so may be a source of error in the magnetic reconstruction of SF experiments. We consistently find that the fractional exhaust power going to a secondary divertor leg on the high field side is small, consistent with SF experiments.

Computer simulation

Off-Design Load Analysis of sCO2 Bottoming Cycle for a Natural Gas Combined Cycle Power Plant with Carbon Capture

As an alternative to a steam cycle, a supercritical carbon dioxide (sCO2) power cycle can be considered. Able et. al performed an analysis of an sCO2 cycle in a 2x2-1 configuration; however, this study did not include carbon capture. Previous studies assumed an H-Frame turbine and added a solvent based 95% carbon capture system and performed a levelized cost of electricity (LCOE) optimization for the plant. Their results suggest a LCOE slightly better than when using a steam cycle. In the study, steam is still generated in the heat recovery sections for the solvent regeneration in the carbon capture stripper reboiler. H-Frame gas turbines are also assumed. This work starts with the optimal design from the mentioned work to analyze the off-design performance of the power plant from 100% down to 50% load. The main operational findings and plant-efficiency for off-load conditions while maintaining the target CO2 capture rate are presented. H-Frame gas turbine off-design performance and exhaust conditions to the heat recovery section are obtained from commercial software, Thermoflow®. The CO2 turbomachinery, heat exchangers and other unit operations are sized and implemented in an Aspen Plus® model. Using the gas turbine exhaust conditions as input, the sCO2 cycle is optimized by adjusting stream split ratios, sCO2 circulation flowrate and compressor speed for maximum efficiency. This is done while keeping the target 95% CO2 capture.

Chinen, Anderson Soares

High-temperature carbon dioxide capture in a porous material with terminal zinc hydride sites

Carbon capture can mitigate point-source carbon dioxide (CO 2 ) emissions, but hurdles remain that impede the widespread adoption of amine-based technologies. Capturing CO 2 at temperatures closer to those of many industrial exhaust streams (>200°C) is of interest, although metal oxide absorbents that operate at these temperatures typically exhibit sluggish CO 2 absorption kinetics and instability to cycling. Here, in this study, we report a porous metal–organic framework featuring terminal zinc hydride sites that reversibly bind CO 2 at temperatures above 200°C—conditions that are unprecedented for intrinsically porous materials. Gas adsorption, structural, spectroscopic, and computational analyses elucidate the rapid, reversible nature of this transformation. Extended cycling and breakthrough analyses reveal that the material is capable of deep carbon capture at low CO 2 concentrations and high temperatures relevant to postcombustion capture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Transformational Sorbent System for Post-Combustion Carbon Capture (Final Report)

As part of this DOE Contract (Transformational Sorbent System for Post-Combustion Carbon Capture, DE-FE0031734),TDA Research Inc. developed a transformational sorbent system for post combustion CO 2 capture process that captures more than 95% of CO 2 emissions from a coal fired power plant, recovering CO 2 at 95% purity with a cost of CO 2 capture significantly lower than with amine-based system (~$30 per tonne (MT) of CO 2 captured). TDA’s transformational sorbent system uses a novel, highly stable, high-capacity metal organic framework (MOF) based CO 2 sorbent in a new vacuum/concentration swing adsorption (VCSA) process that allows us to use high efficiency vacuum pumps with a low auxiliary load. A pulverized coal fired power plant equipped with TDA’s transformational sorbent system for post combustion CO 2 capture is expected to efficiently produce electricity with a low Cost of Electricity (COE) and capture greater than 95% of the CO 2 from the power plant exhaust.

01 COAL, LIGNITE, AND PEAT

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

An Exploratory Data Mining Investigation for Constructing a Publicly Sourced Dataset of Foreign Hypersonic Tests

This document details a data mining exercise that resulted in an exploratory dataset of publicly reported foreign (non-US) hypersonic vehicle test events. Using a combination of targeted English language searches and country-specific queries, the study aggregates information from digital news media, official press releases, and social media posts. The resulting list of events captures the publicly available accounts of foreign hypersonic tests, although it does not represent an exhaustive record. Limitations such as inconsistent reporting, translation challenges, and the inherently provisional nature of open-source data are acknowledged. This dataset serves as an initial reference point for further inquiries into high-speed atmospheric phenomena and may facilitate future efforts to correlate these events with geophysical measurements.

33 ADVANCED PROPULSION SYSTEMS

Clean Water Production in Cooling Towers

This project developed and demonstrated a novel technology that produces clean water from cooling tower recirculating water by using the natural evaporation and condensation cycle inside cooling towers. The system captures the escaping plume and converts blowdown quality water into high purity water suitable for on-site reuse such as boiler feed. The technology uses electric fields to ionize exhaust plumes, charge the entrained droplets, and direct them toward collection electrodes where they coalesce and flow downward. This allows water recovery at a low energy cost while reducing visible plume emissions. In addition, we developed a complementary software platform that improves overall cooling tower performance. The system uses wireless sensors and physics-based machine learning algorithms to optimize key parameters of the cooling process. For power generation facilities, this increases the thermal efficiency of the cooling loop and condenser, resulting in measurable cycle efficiency gains. Improvements of one percent or more can deliver significant increases in electricity production for the same fuel input.

01 COAL, LIGNITE, AND PEAT

CFD modeling of non-catalytic, partial-oxidation engine reformer for flare mitigation

Flaring associated natural gas is commonly employed in the oil and gas industry to reduce methane (CH 4 ) emissions but generates carbon dioxide (CO 2 ) and harmful pollutants, significantly contributing to air pollution and posing risks to public health. To mitigate this impact, M2X Energy Inc. has developed a small-scale, modular gas-to-methanol system. This system features an engine reformer that performs fuel-rich partial oxidation of wellhead gas to produce syngas—a mixture of carbon monoxide (CO) and hydrogen (H 2 )—followed by a downstream reactor for methanol synthesis. This study focused on computational fluid dynamics (CFD) modeling of the engine reformer to simulate partial oxidation chemistry, predict the rich-burn operating limit, and assess syngas quality, ultimately aiding in design and operational optimization. The CFD model, developed within a Reynolds-Averaged Navier-Stokes (RANS) turbulence framework, incorporated sub-models for turbulent combustion, a chemical mechanism with polycyclic aromatic hydrocarbon (PAH) pathways, and soot emissions to accurately capture the fuel-rich, turbulent jet ignition and combustion processes. Model validation against experimental data showed good agreement across pre- and main-chamber pressures, apparent heat release rates, and exhaust gas concentrations of key species (H 2 , CO, CO 2 , CH 4 ) for varying intake equivalence ratios. Here, the model identified a rich-burn operating limit near a fuel-air equivalence ratio of 2.35, consistent with experimental observations. Furthermore, syngas quality analysis revealed that extending the rich-burn limit through engine reformer optimization could enhance syngas production, contributing to higher methanol synthesis efficiency.

Computational Fluid Dynamics

Comparative Technoeconomic Analysis and Life Cycle Assessment of Emerging Reactive Carbon Capture-to-Methanol Pathways

Our group recently developed dual-function materials (DFMs) and reactive carbon capture (RCC) processes for the selective production of methanol (MeOH) or CO, offering two novel and unique pathways for MeOH production. This study conducted a comparative techno-economic analysis (TEA) of the two RCC pathways from exhaust CO 2 : 1) a “Direct RCC-to-MeOH” pathway and 2) an “Indirect RCC-to-CO” pathway followed by MeOH synthesis. The “Direct RCC-to-MeOH” pathway produced a lower levelized cost of MeOH (LCOM) at $\$$0.78/kg, compared to $\$$0.84/kg for the “Indirect RCC-to-CO” pathway. The key difference is the need to recompress the syngas from RCC before MeOH synthesis in “Indirect RCC-to-CO.” Nonetheless, with reduced catalyst costs and hydrogen requirements for “RCC-to-CO,” this pathway merits further study to produce syngas rather than MeOH. Both pathways are comparable in LCOM to baseline e-MeOH production from CO 2 hydrogenation ($\$$0.72/kg) while having lower carbon intensities (0.45 and 0.51 kg-CO 2 e/kg vs 0.54 kg-CO 2 e/kg).

08 HYDROGEN

Carbon Capture Pilot at Dry Fork Power Station (Final Technical Report)

The objective of this project was to design, seek necessary approvals, build and operate a large-scale pilot sorbent-based post combustion carbon capture system (CCS) at a coal fired power generation facility. TDA’s CCS uses a highly stable, low-cost, high-capacity physical adsorbent to effectively remove CO 2 via a combination vacuum and concentration swing adsorption (VCSA) process. The CCS is integrated with the power plant flue gas exhaust, which is rich in CO 2 (~13% vol. CO 2 ) and removes more than 90% of the plant’s overall carbon emissions.

01 COAL, LIGNITE, AND PEAT

Advanced Data Management for the Wastewater Industry

This information sheet discusses the technology pillar Advanced Data Management as a pathway toward improving wastewater infrastructure sustainability and resiliency. To supplement existing literature on current technologies and policies for improving resiliency at wastewater treatment plants (WWTPs), this document aims to accomplish the following: • Summarize key technologies such as Supervisory Control and Data Acquisition (SCADA), digital twins, and smart sensors • Summarize relevant cybersecurity measures and data management tools available for WW utilities • Summarize advances in sensing and monitoring technologies • Serve as a comprehensive (though not exhaustive) repository for data management for wastewater utilities The Advanced Management Technical Information Sheet should be viewed as a general guide to established best practices for the water and wastewater sector when considering implementing energy capture and energy- or process-efficient technologies. Further details are presented in the SWIFt Technology Information Sheet Series for accompanying Technology Pillars.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Resource Recovery for the Wastewater Industry

This information sheet discusses the technology pillar, Resource Recovery, as a pathway toward improving wastewater infrastructure sustainability and resiliency. To supplement existing literature on current technologies and policies for improving resiliency at wastewater (WW) treatment plants, this document aims to accomplish the following: • Summarize wastewater sludge recovery methods • Summarize biogas production and codigestion methods • Serve as a comprehensive (though not exhaustive) repository for resource recovery for wastewater utilities The Resource Recovery Technical Information Sheet should be viewed as a general guide to established best practices for the water and wastewater (W/WW) sector when considering implementing energy capture technologies. Additional details on associated energy capture avenues such as combined heat and power (CHP), renewable energy, and inline hydropower from tertiary effluent in W/WW facilities are presented in the Energy Capture Technology Information Sheet.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Hybrid combustion modeling approach for turbulent jet ignition in natural-gas pre-chamber spark-ignition engines at high EGR

Here, this study presented a hybrid modeling approach for simulating turbulent jet ignition and combustion processes in a natural-gas pre-chamber spark-ignition engine operating under exhaust gas recirculation (EGR) diluted conditions. In-depth analyses of experimental data and simulation results from previous work [Chinnathambi et al., ICEF2021-67836; Kim et al., Fuel 409: 137815, 2026] revealed two key findings: (i) the magnitude of pressure difference between the pre-chamber and main chamber ($∆P_{PC-MC}$) was positively correlated with the combustion duration from the moment of $∆P_{PC-MC}=0$ to the point of 5% mass fraction burned, with larger $∆P_{PC-MC}$ associated with longer duration; and (ii) the turbulent combustion regime in the main chamber transitioned from the broken reaction zone to the corrugated flamelet regime, with the Karlovitz number exceeding 100 immediately after turbulent hot jets were ejected from nozzles, coinciding with observed local extinction events. To accurately simulate the entire combustion process, a hybrid approach was developed under Reynolds-Averaged Navier Stokes framework, combining the G-equation model for pre-chamber combustion with the multi-zone well-stirred reactor approach and a turbulence-chemistry interaction (TCI) submodel for main chamber combustion. The TCI submodel accounted for the attenuation of reaction rates due to turbulent strain and modeled local extinction by suppressing reaction rates under certain flow and flame conditions. When applied to three EGR rate conditions toward the dilution limit, the hybrid modeling approach accurately reproduced experimental data in terms of cylinder pressure, apparent heat release rate, and the observed positive correlation, including the delayed onset of main chamber combustion—a feature not captured by existing combustion models.

computational fluid dynamics simulation

Image masks of global ship tracks for NASA MODIS data products

Ship tracks, long thin artificial cloud features formed from the pollutants in ship exhaust, are satellite-observable examples of aerosol-cloud interactions (ACI) that can lead to increased cloud albedo and thus increased solar reflectivity, phenomena of interest in solar radiation management. In addition to ship tracks being of interest to meteorologists and policy makers, their observed cloud perturbations provide benchmark evidence of ACI that remain poorly captured by climate models. To broadly analyze the effects of ship tracks, high-resolution satellite imagery data highlighting their presence are required. To support this, we provide a hand labelled dataset to serve as a benchmark for a variety of subsequent analyses. Established from a previous dataset that identified ship track presence using NASA’s MODIS Aqua satellite imager, our first-of-its-kind dataset is comprised of image masks: capturing full ship track regions, including their contours, emission points and dispersive patterns. In total, 300 images, or around 2,500 masked ship tracks, observed under varying conditions are provided, and may facilitate training of machine learning algorithms to automate extraction.

Atmospheric dynamics