Search NASA⌕ Search

SEARCH · Search NASA

Results for “Exit hole”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Reinforcing the exit hole from friction stir welding and processing

After friction stir welding/processing (FSW/P), an exit hole remains at the end of the run, which can be the weakest region of the welded/processed workpiece. In addition, tensile residual stress around the exit hole resulting from heating during FSW/P facilitates incipient crack initiating from the exit hole under external loading. Current solutions include removing or repairing the exit hole, which are time-consuming and costly. Here, we propose a novel method to reinforce the exit hole by applying an additional FSW/P pass around it, in a way that replaces preexisting tensile residual stress with compressive residual stress. Under external loading, there is no evident strain accumulation around the exit hole, and the workpiece ultimately fails along the FSW/P heat affected zone. This method provides a more convenient way to reinforce the exit hole than the current exit-hole repair or removal methods for industrial applications.

36 MATERIALS SCIENCE↗

Effect of velocity and temperature distribution at the hole exit on film cooling of turbine blades

An existing three-dimensional Navier-Stokes code, modified to include film cooling considerations, has been used to study the effect of coolant velocity and temperature distribution at the hole exit on the heat transfer coefficient on three-film-cooled turbine blades, namely, the C3X vane, the VKI rotor, and the ACE rotor. Results are also compared with the experimental data for all the blades. Moreover, Mayle's transition criterion, Forest's model for augmentation of leading edge heat transfer due to freestream turbulence, and Crawford's model for augmentation of eddy viscosity due to film cooling are used. Use of Mayle's and Forest's models is relevant only for the ACE rotor due to the absence of showerhead cooling on this rotor. It is found that, in some cases, the effect of distribution of coolant velocity and temperature at the hole exit can be as much as 60% on the heat transfer coefficient at the blade suction surface, and 50% at the pressure surface. Also, different effects are observed on the pressure and suction surface depending upon the blade as well as upon the hole shape, conical or cylindrical.

Garg, Vijay K.↗

Effect of Velocity and Temperature Distribution at the Hole Exit on Film Cooling of Turbine Blades

An existing three-dimensional Navier-Stokes code (Arnone et al, 1991), modified Turbine Branch, to include film cooling considerations (Garg and Gaugler, 1994), has been used to study the effect of coolant velocity and temperature distribution at the hole exit on the heat transfer coefficient on three film-cooled turbine blades, namely, the C3X vane, the VKI rotor, and the ACE rotor. Results are also compared with the experimental data for all the blades. Moreover, Mayle's transition criterion (1991), Forest's model for augmentation of leading edge heat transfer due to free-stream turbulence (1977), and Crawford's model for augmentation of eddy viscosity due to film cooling (Crawford et al, 1980) are used. Use of Mayle's and Forest's models is relevant only for the ACE rotor due to the absence of showerhead cooling on this rotor. It is found that, in some cases, the effect of distribution of coolant velocity and temperature at the hole exit can be as much as 60 percent on the heat transfer coefficient at the blade suction surface, and 50 percent at the pressure surface. Also, different effects are observed on the pressure and suction surface depending upon the blade as well as upon the hole shape, conical or cylindrical.

Garg, V. K.↗

Modeling Film-Coolant Flow Characteristics at the Exit of Shower-Head Holes

The coolant flow characteristics at the hole exits of a film-cooled blade are derived from an earlier analysis where the hole pipes and coolant plenum were also discretized. The blade chosen is the VKI rotor with three staggered rows of shower-head holes. The present analysis applies these flow characteristics at the shower-head hole exits. A multi-block three-dimensional Navier-Stokes code with Wilcox's k-omega model is used to compute the heat transfer coefficient on the film-cooled turbine blade. A reasonably good comparison with the experimental data as well as with the more complete earlier analysis where the hole pipes and coolant plenum were also gridded is obtained. If the 1/7th power law is assumed for the coolant flow characteristics at the hole exits, considerable differences in the heat transfer coefficient on the blade surface, specially in the leading-edge region, are observed even though the span-averaged values of h (heat transfer coefficient based on T(sub o)-T(sub w)) match well with the experimental data. This calls for span-resolved experimental data near film-cooling holes on a blade for better validation of the code.

Garg, Vijay K.↗

Dense Pattern Optical Multipass Cell

A multiple pass optical cell and method comprising providing a pair of opposed cylindrical mirrors having curved axes with substantially equal focal lengths, positioning an entrance hole for introducing light into the cell and an exit hole for extracting light from the cell, wherein the entrance hole and exit hole are coextensive or non-coextensive, introducing light into the cell through the entrance hole, and extracting light from the cell through the exit hole.

Silver, Joel A.↗

Neutron Characterization of 3D Printed Gas Turbine Alloy With Internal Cooling Structure

The objective of this research work is to investigate the residual strains induced by the presence of a exit hole and internal hollow geometry present in a 3D printed IN718 similar to that seen in a gas turbine blade. The specimens were manufactured with an internal hollow structure that ended with an exit hole, and fabricated by direct metal laser sintering additive manufacturing technique. Using this technique, metal powder was melted by a laser source and rapidly cooled to form the part layer by layer. Rapid heating and cooling generate large thermal gradients and residual stresses in the 3D printed material. To be aligned with industry standards, specimens were heat-treated to relieve most of the residual stresses as well as to investigate whether IN718 still preserved a nonhomogeneous stress state after the thermal treatment. Roughness and microstructure analysis was performed to understand the heat-treated sample properties. To investigate the volumetric residual strain, the neutron diffraction technique was used with a definite neutron wavelength. Bragg’s law was used to determine lattice spacing. Interplanar lattice spacing and stress-free state lattice spacings were measured to calculate the strains. Residual strains were measured in the x and y direction to understand the impact of the presence of a exit hole and internal hollow geometry. The results of volumetric residual strain in the x and y directions showed no significant variations in the distribution of the strain due to the presence of a hollow structure as well as the exit hole. Overall, no significant stress concentration was observed in the heat treated sample. Sample geometry, instrumentation for neutron diffraction, and material properties are discussed in detail in this paper.

Raju, Nandhini↗

Continuous laminar smoke generator

A smoke generator capable of emitting a very thin, laminar stream of smoke for use in high detail flow visualization was invented. The generator is capable of emitting a larger but less stable rope of smoke. The invention consists of a pressure supply and fluid supply which supply smoke generating fluid to feed. The feed tube is directly heated by electrical resistance from current supplied by power supply and regulated by a constant temperature controller. A smoke exit hole is drilled in the wall of feed tube. Because feed tube is heated both before and past exit hole, no condensation of smoke generating occurs at the smoke exit hole, enabling the production of a very stable smoke filament. The generator is small in size which avoids wind turbulence in front of the test model.

Weinstein, L. M.↗

STS-118 Radiator Impact Damage

During the August 2007 STS-118 mission to the International Space Station, a micro-meteoroid or orbital debris (MMOD) particle impacted and completely penetrated one of shuttle Endeavour s radiator panels and the underlying thermal control system (TCS) blanket, leaving deposits on (but no damage to) the payload bay door. While it is not unusual for shuttle orbiters to be impacted by small MMOD particles, the damage from this impact is larger than any previously seen on the shuttle radiator panels. A close-up photograph of the radiator impact entry hole is shown in Figure 1, and the location of the impact on Endeavour s left-side aft-most radiator panel is shown in Figure 2. The aft radiator panel is 0.5-inches thick and consists of 0.011 inch thick aluminum facesheets on the front and back of an aluminum honeycomb core. The front facesheet is additionally covered by a 0.005 inch thick layer of silver-Teflon thermal tape. The entry hole in the silver-Teflon tape measured 8.1 mm by 6.4 mm (0.32 inches by 0.25 inches). The entry hole in the outer facesheet measured 7.4 mm by 5.3 mm (0.29 inches by 0.21 inches) (0.23 inches). The impactor also perforated an existing 0.012 inch doubler that had been bonded over the facesheet to repair previous impact damage (an example that lightning can strike the same place twice, even for MMOD impact). The peeled-back edge around the entry hole, or lip , is a characteristic of many hypervelocity impacts. High velocity impact with the front facesheet fragmented the impacting particle and caused it to spread out into a debris cloud. The debris cloud caused considerable damage to the internal honeycomb core with 23 honeycomb cells over a region of 28 mm by 26 mm (1.1 inches by 1.0 inches) having either been completely destroyed or partially damaged. Figure 3 is a view of the exit hole in the rear facesheet, and partially shows the extent of the honeycomb core damage and clearly shows the jagged petaled exit hole through the backside facesheet. The rear facesheet exit hole damage including cracks in the facesheet measures 14 mm by 14 mm (0.55 inches by 0.55 inches). The remnants of the impacting particle and radiator panel material blown through the rear facesheet hole also created two penetrations in the TCS blanket 115 mm (4.5 inches) behind the rear facesheet. Figure 4 shows these two impacts, which are located 75 mm (3 inches) apart. Some deposits of material were found on the payload bay door beneath the TCS blanket, but no additional damage occurred to the door. Figure 5 illustrates the relationship of the facesheet entry hole to the TCS blanket damage, which may indicate the direction of the impacting particle. The image on the left side of Figure 5 shows an overhead view of the damaged radiator after the facesheet holes were cored out of the panel. The entry hole location and the two underlying TCS blanket damage sites are annotated on the image. Section A-A, running through the entry hole and TCS blanket damage locations, describes a 25 angle from the longitudinal axis of the shuttle. The 2nd impact angle can be seen in section A-A on the right side of Figure 5. An average 17 angle of impact to the surface normal was derived by measuring the angles of the two damage sites in TCS blanket to the entry hole.

Lear, Dana M.↗

Heat Transfer on a Film-Cooled Blade - Effect of Hole Physics

A multi-block, three-dimensional Navier-Stokes code has been used to study the within-hole and near-hole physics in relation to heat transfer on a film-cooled blade. The flow domain consists of the coolant flow through the plenum and hole-pipes for the three staggered rows of shower-head holes on the VK1 rotor, and the main flow over the blade. A multi-block grid is generated that is nearly orthogonal to the various surfaces. It may be noted that for the VK1 rotor the shower-head holes are inclined at 30 deg. to the spanwise direction, and are normal to the streamwise direction on the blade. Wilcox's k-omega turbulence model is used. The present study provides a much better comparison for the heat transfer coefficient at the blade mid-span with the experimental data than an earlier analysis wherein coolant velocity and temperature distributions were specified at the hole exits rather than extending the computational domain into the hole-pipe and plenum. Details of the distributions of coolant velocity, temperature, k and omega at the hole exits are also presented.

Garg, Vijay K.↗

Heat Transfer on a Film-Cooled Blade: Effect of Hole Physics

A multiblock, three-dimensional Navier Stokes code has been used to study the within-hole and near-hole physics in relation to heat transfer on a film-cooled blade. The flow domain consists of the coolant flow through the plenum and hole-pipes for the three staggered rows of shower-head holes on the VKI rotor, and the main flow over the blade. A multiblock grid is generated that is nearly orthogonal to the various surfaces. It may be noted that for the VKI rotor the shower-head holes are inclined at 30 deg to the spanwise direction, and are normal to the streamwise direction on the blade. Wilcox's k-omega turbulence model is used. The present study provides a much better comparison for the span-averaged heat transfer coefficient on the blade surface with the experimental data than an earlier analysis wherein coolant velocity and temperature distributions were specified at the hole exits rather than extending the computational domain into the hole-pipe and plenum. Details of the distributions of coolant velocity, temperature, k and omega at the hole exits are also presented.

Garg, Vijay K.↗

Liquid Scavenger for Separator/Pump

Pump for hydrogen modified to remove moisture that condenses in impeller stage. Impeller-pump housing has circumferential groove leading to exit hole near high-pressure outlet. As impeller disk rotates, flings water droplets condensed in pump toward groove. Aerodynamic drag drives water around groove to exit hole.

Berg, P. F.↗

Heat Transfer on a Film-Cooled Rotating Blade

A multi-block, three-dimensional Navier-Stokes code has been used to compute heat transfer coefficient on the blade, hub and shroud for a rotating high-pressure turbine blade with 172 film-cooling holes in eight rows. Film cooling effectiveness is also computed on the adiabatic blade. Wilcox's k-omega model is used for modeling the turbulence. Of the eight rows of holes, three are staggered on the shower-head with compound-angled holes. With so many holes on the blade it was somewhat of a challenge to get a good quality grid on and around the blade and in the tip clearance region. The final multi-block grid consists of 4784 elementary blocks which were merged into 276 super blocks. The viscous grid has over 2.2 million cells. Each hole exit, in its true oval shape, has 80 cells within it so that coolant velocity, temperature, k and omega distributions can be specified at these hole exits. It is found that for the given parameters, heat transfer coefficient on the cooled, isothermal blade is highest in the leading edge region and in the tip region. Also, the effectiveness over the cooled, adiabatic blade is the lowest in these regions. Results for an uncooled blade are also shown, providing a direct comparison with those for the cooled blade. Also, the heat transfer coefficient is much higher on the shroud as compared to that on the hub for both the cooled and the uncooled cases.

Garg, Vijay K.↗

A Numerical Study of Anti-Vortex Film Cooling Designs at High Blowing Ratio

A concept for mitigating the adverse effects of jet vorticity and liftoff at high blowing ratios for turbine film cooling flows has been developed and studied at NASA Glenn Research Center. This "anti-vortex" film cooling concept proposes the addition of two branched holes from each primary hole in order to produce a vorticity counter to the detrimental kidney vortices from the main jet. These vortices typically entrain hot freestream gas and are associated with jet separation from the turbine blade surface. The anti-vortex design is unique in that it requires only easily machinable round holes, unlike shaped film cooling holes and other advanced concepts. The anti-vortex film cooling hole concept has been modeled computationally for a single row of 30deg angled holes on a flat surface using the 3D Navier-Stokes solver Glenn-HT. A modification of the anti-vortex concept whereby the branched holes exit adjacent to the main hole has been studied computationally for blowing ratios of 1.0 and 2.0 and at density ratios of 1.0 and 2.0. This modified concept was selected because it has shown the most promise in recent experimental studies. The computational results show that the modified design improves the film cooling effectiveness relative to the round hole baseline and previous anti-vortex cases, in confirmation of the experimental studies.

Heidmann, James D.↗

Sweeping Jet Film Cooling at High Blowing Ratio on a Turbine Vane

Abstract Experimental and numerical investigations were performed to study the effects of high blowing ratios and high freestream turbulence on sweeping jet film cooling. Experiments were conducted on a nozzle guide vane suction surface in a low-speed linear cascade at a range of blowing ratios of 0.5–3.5 and freestream turbulence of 0.6% and 14.3%. Infrared thermography was used to estimate the adiabatic cooling effectiveness. Thermal field and boundary layer measurements were conducted at a cross-plane at x/D = 12 downstream of the hole exit. Results were compared with a baseline 777-shaped hole and showed that the sweeping jet hole has improved cooling effectiveness at high blowing ratios (M > 1). The thermal field data revealed that the coolant separates from the surface at high blowing ratios for the 777-shaped hole while the coolant remains attached for the sweeping jet hole. Boundary layer measurements further confirmed that due to the sweeping motion of the jet, the effective jet momentum of the sweeping jet hole remains much lower than that of a 777-shaped hole. Thus, the coolant remains closer to the wall even at high blowing ratios. Large Eddy simulations (LES) were performed for both the sweeping jet and 777-shaped hole to evaluate the interaction between the coolant jet and the freestream in the near hole regions. Results showed that 777-shaped hole has a strong jetting at high blowing ratio that originates inside the hole breakout edges thus causing the jet to blow-off from the surface. In contrast, the sweeping jet does not show this behavior due to its internal geometry and flapping motion of the jet.

Engineering↗

A Three-Dimensional Coupled Internal/External Simulation of a Film-Cooled Turbine Vane

A three-dimensional Navier-Stokes simulation has been performed for a realistic film-cooled turbine vane using the LeRC-HT code. The simulation includes the flow regions inside the coolant plena and film cooling holes in addition to the external flow. The vane is the subject of an upcoming NASA Glenn Research Center experiment and has both circular cross-section and shaped film cooling holes. This complex geometry is modeled using a multi-block grid which accurately discretizes the actual vane geometry including shaped holes. The simulation matches operating conditions for the planned experiment and assumes periodicity in the spanwise direction on the scale of one pitch of the film cooling hole pattern. Two computations were performed for different isothermal wall temperatures, allowing independent determination of heat transfer coefficients and film effectiveness values. The results indicate separate localized regions of high heat transfer coefficient values, while the shaped holes provide a reduction in heat flux through both parameters. Hole exit data indicate rather simple skewed profiles for the round holes, but complex profiles for the shaped holes with mass fluxes skewed strongly toward their leading edges.

Heidmann, James D.↗

Prediction of Film Cooling on Gas Turbine Airfoils

A three-dimensional Navier-Stokes analysis tool has been developed in order to study the effect of film cooling on the flow and heat transfer characteristics of actual turbine airfoils. An existing code (Arnone et al., 1991) has been modified for the purpose. The code is an explicit, multigrid, cell-centered, finite volume code with an algebraic turbulence model. Eigenvalue scaled artificial dissipation and variable-coefficient implicit residual smoothing are used with a full-multigrid technique. Moreover, Mayle's transition criterion (Mayle, 1991) is used. The effects of film cooling have been incorporated into the code in the form of appropriate boundary conditions at the hole locations on the airfoil surface. Each hole exit is represented by several control volumes, thus providing an ability to study the effect of hole shape on the film-cooling characteristics. Comparison is fair with near mid-span experimental data for four and nine rows of cooling holes, five on the shower head, and two rows each on the pressure and suction surfaces. The computations, however, show a strong spanwise variation of the heat transfer coefficient on the airfoil surface, specially with shower-head cooling.

Garg, Vijay K.↗

Coarse Grid Modeling of Turbine Film Cooling Flows Using Volumetric Source Terms

The recent trend in numerical modeling of turbine film cooling flows has been toward higher fidelity grids and more complex geometries. This trend has been enabled by the rapid increase in computing power available to researchers. However, the turbine design community requires fast turnaround time in its design computations, rendering these comprehensive simulations ineffective in the design cycle. The present study describes a methodology for implementing a volumetric source term distribution in a coarse grid calculation that can model the small-scale and three-dimensional effects present in turbine film cooling flows. This model could be implemented in turbine design codes or in multistage turbomachinery codes such as APNASA, where the computational grid size may be larger than the film hole size. Detailed computations of a single row of 35 deg round holes on a flat plate have been obtained for blowing ratios of 0.5, 0.8, and 1.0, and density ratios of 1.0 and 2.0 using a multiblock grid system to resolve the flows on both sides of the plate as well as inside the hole itself. These detailed flow fields were spatially averaged to generate a field of volumetric source terms for each conservative flow variable. Solutions were also obtained using three coarse grids having streamwise and spanwise grid spacings of 3d, 1d, and d/3. These coarse grid solutions used the integrated hole exit mass, momentum, energy, and turbulence quantities from the detailed solutions as volumetric source terms. It is shown that a uniform source term addition over a distance from the wall on the order of the hole diameter is able to predict adiabatic film effectiveness better than a near-wall source term model, while strictly enforcing correct values of integrated boundary layer quantities.

Heidmann, James D.↗

Updated Thermofluid Performance of the Simplified Flat Variant of the HEMJ

Our group has recently developed and studied “finger”-type divertors that are a simplified version of the helium-cooled modular divertor with multiple jets (HEMJ) using coupled computational fluid dynamics and thermal stress simulations. Such a simplified geometry could reduce complexity and cost given the large number of fingers required to cover the total divertor target area. Previous experimental studies for this simplified flat design reported lower heat transfer coefficients and higher pressure drops than the HEMJ, contrary to numerical predictions. Subsequent measurements determined that the original test section had significant dimensional variations in the jet exit holes. A new test section was therefore manufactured and tested in the Georgia Tech (GT) helium loop. The experimental results presented here for this test section at maximum heat flux of 7.1 MW/m 2 are in good agreement with numerical predictions. Correlations developed from these experimental data are extrapolated to predict the maximum heat flux that can be accommodated by the flat design and the coolant pumping power requirements under prototypical conditions. Lastly, numerical simulations are used to estimate the sensitivity of the flat design to geometric variations typical of manufacturing tolerances and variations in the gap width.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗