Search NASA⌕ Search

SEARCH · Search NASA

Results for “Exoskeleton”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Design and control of a hand exoskeleton for use in extravehicular activities

To counter problems inherent in extravehicular activities (EVA) and complex space operations, an exoskeleton, a unique adaptive structure, has been designed. The exoskeleton fits on the hand and powers the proximal and middle phalanges of the index finger, the middle finger, and the combined ring and little finger. A kinematic analysis of the exoskeleton joints was performed using the loop-closure method. This analysis determined the angular displacement and velocity relationships of the exoskeleton joints. This information was used to determine the output power of the exoskeleton. Three small DC motors (one for each finger) are used to power the exoskeleton. The motors are mounted on the forearm. Power is transferred to the exoskeleton using lead screws. The control system for the exoskeleton measures the contact force between the operator and the exoskeleton. This information is used as the input to drive the actuation system. The control system allows the motor to rotate in both directions so that the operator may close or open the exoskeleton.

Shields, B.↗

Sensing And Force-Reflecting Exoskeleton

Sensing and force-reflecting exoskeleton (SAFiRE) provides control signals to robot hand and force feedback from robot hand to human operator. Operator makes robot hand touch objects gently and manipulates them finely without exerting excessive forces. Device attaches to operator's hand; comfortable and lightweight. Includes finger exoskeleton, cable mechanical transmission, two dc servomotors, partial thumb exoskeleton, harness, amplifier box, two computer circuit boards, and software. Transduces motion of index finger and thumb. Video monitor of associated computer displays image corresponding to motion.

Eberman, Brian↗

Exoskeleton master controller with force-reflecting telepresence

A thorough understanding of the requirements for successful master-slave robotic systems is becoming increasingly desirable. Such systems can aid in the accomplishment of tasks that are hazardous or inaccessible to humans. Although a history of use has proven master-slave systems to be viable, system requirements and the impact of specifications on the human factors side of system performance are not well known. In support of the next phase of teleoperation research being conducted at the Armstrong Research Laboratory, a force-reflecting, seven degree of freedom exoskeleton for master-slave teleoperation has been concepted, and is presently being developed. The exoskeleton has a unique kinematic structure that complements the structure of the human arm. It provides a natural means for teleoperating a dexterous, possibly redundant manipulator. It allows ease of use without operator fatigue and faithfully follows human arm and wrist motions. Reflected forces and moments are remotely transmitted to the operator hand grip using a cable transmission scheme. This paper presents the exoskeleton concept and development results to date. Conceptual design, hardware, algorithms, computer architecture, and software are covered.

Burke, James B.↗

Lightweight Exoskeletons with Controllable Actuators

A proposed class of lightweight exoskeletal electromechanical systems would include electrically controllable actuators that would generate torques and forces that, depending on specific applications, would resist and/or assist wearers movements. The proposed systems would be successors to relatively heavy, bulky, and less capable human-strength-amplifying exoskeletal electromechanical systems that have been subjects of research during the past four decades. The proposed systems could be useful in diverse applications in which there are needs for systems that could be donned or doffed easily, that would exert little effect when idle, and that could be activated on demand: examples of such applications include (1) providing controlled movement and/or resistance to movement for physical exercise and (2) augmenting wearers strengths in the performance of military, law-enforcement, and industrial tasks. An exoskeleton according to the proposal would include adjustable lightweight graphite/epoxy struts and would be attached to the wearer's body by belts made of hook-and-pile material. At selected rotary and linear joints, the exoskeleton would be fitted, variously, with lightweight, low-power-consumption rotary and linear brakes, clutches, and motors. The exoskeleton would also be equipped with electronic circuitry for monitoring, control, and possibly communication with external electronic circuits that would perform additional monitoring and control functions.

Bar-Cohen, Yoseph↗

X1: A Robotic Exoskeleton for In-Space Countermeasures and Dynamometry

Bone density loss and muscle atrophy are among the National Aeronautics and Space Administration's (NASA) highest concerns for crew health in space. Countless hours are spent maintaining an exercise regimen aboard the International Space Station (ISS) to counteract the effect of zero-gravity. Looking toward the future, NASA researchers are developing new compact and innovative exercise technologies to maintain crew health as missions increase in length and take humans further out into the solar system. The X1 Exoskeleton, initially designed for assisted mobility on Earth, was quickly theorized to have far-reaching potential as both an in-space countermeasures device and a dynamometry device to measure muscle strength. This lower-extremity device has the ability to assist or resist human movement through the use of actuators positioned at the hips and knees. Multiple points of adjustment allow for a wide range of users, all the while maintaining correct joint alignment. This paper discusses how the X1 Exoskeleton may fit NASA's onorbit countermeasures needs.

Rea, Rochelle↗

Comparison of Knee and Ankle Dynamometry between NASA's X1 Exoskeleton and Biodex System 4

Pre- and post-flight dynamometry is performed on International Space Station crewmembers to characterize microgravity-induced strength changes. Strength is not assessed in flight due to hardware limitations and there is poor understanding of the time course of in-flight changes. PURPOSE: To assess the reliability of a prototype dynamometer, the X1 Exoskeleton (EXO) and its agreement with a Biodex System 4 (BIO). METHODS: Eight subjects (4 M/4 F) completed 2 counterbalanced testing sessions of knee extension/flexion (KE/KF), 1 with BIO and 1 with EXO, with repeated measures within each session in normal gravity. Test-retest reliability (test 1 and 2) and device agreement (BIO vs. EXO) were evaluated. Later, to assess device agreement for ankle plantarflexion (PF), 10 subjects (4 M/6 F) completed 3 test conditions (BIO, EXO, and BIOEXO); BIOEXO was a hybrid condition comprised of the Biodex dynamometer motor and the X1 footplate and ankle frame. Ankle comparisons were: BIO vs. BIOEXO (footplate differences), BIOEXO vs. EXO (motor differences), and BIO vs. EXO (all differences). Reliability for KE/KF was determined by intraclass correlation (ICC). Device agreement was assessed with: 1) repeated measures ANOVA, 2) a measure of concordance (rho), and 3) average difference. RESULTS: ICCs for KE/KF were 0.99 for BIO and 0.96 to 0.99 for EXO. Agreement was high for KE (concordance: 0.86 to 0.95; average differences: -7 to +9 Nm) and low to moderate for KF (concordance: 0.64 to 0.78; average differences: -4 to -29 Nm, P<0.05). BIO vs. BIOEXO PF concordance ranged from 0.89 to 0.92 and mean differences ranged from -9 to +3 Nm (BIO < BIOEXO). BIOEXO vs. EXO PF concordance ranged from 0.73 to 0.80 while mean differences were -18 to -36 Nm (BIOEXO < EXO, P<0.05). PF concordance for BIO vs. EXO was slightly lower (0.61 to 0.84) and mean differences were greater (-27 to -33 Nm; BIO < EXO, P<0.05). CONCLUSION: BIO and EXO were similarly reliable for KE and KF. KE measures produced high agreement between devices; KF did not. For ankle PF, torque differences due to the two footplates were small. However, the X1 motor reports greater torques than the Biodex motor during PF. This first prototype provides proof of concept for a reliable, robotic-based exoskeleton to perform portable dynamometry for large muscle groups of the lower body.

English, K. L.↗

Human Grasp Assist Device With Exoskeleton

A grasp assist system includes a glove, actuator assembly, and controller. The glove includes a digit, i.e., a finger or thumb, and a force sensor. The sensor measures a grasping force applied to an object by an operator wearing the glove. Phalange rings are positioned with respect to the digit. A flexible tendon is connected at one end to one of the rings and is routed through the remaining rings. An exoskeleton positioned with respect to the digit includes hinged interconnecting members each connected to a corresponding ring, and/or a single piece of slotted material. The actuator assembly is connected to another end of the tendon. The controller calculates a tensile force in response to the measured grasping force, and commands the tensile force from the actuator assembly to thereby pull on the tendon. The exoskeleton offloads some of the tensile force from the operator's finger to the glove.

Bergelin, Bryan J↗

Small Business Innovations (Exoskeletons)

The Dexterous Hand Master (DHM), a 1989 winner of an R&D 100 Award, is an exoskeleton device for measuring the joints of the human hand with extreme precision. It was originally developed for NASA by Arthur D. Little, and is sold commercially by EXOS, Inc. The DHM is worn on the hand and connected to a computer that records hand motions. The resulting data is transmitted as control signals to robots and other computers, enabling robotic hands to emulate human hand actions. Two additional spinoff products were also inspired by the DHM.

Source record↗

Plugin for Integrated Exoskeleton Simulations (PIES)

Upper extremity offload is a new capability to be developed for the Active Response Gravity Offload System (ARGOS) at the Johnson Space Center. To address the need, the Actuated Real-time Control for ARGOS Negation of Gravitational Effects on the Limbs (ARC-ANGEL) system is being designed and developed by the HumanWorks team in the Flight Systems Branch (ER3). The Plugin for Integrated Exoskeleton Simulations (PIES) is a multibody modeling and analysis capability developed by the Digital Astronaut Simulation (DAS) team in the Simulation and Graphics Branch (ER7). The C++ plugin is used in the open source biomechanics software, OpenSim (Stanford University), and integrates human multibody modeling with system dynamic modeling. The latest ‘flavor’ is the ANGEL with Passive and Powered Line of force Evaluation (APPLE) PIES.

Kaitlin Lostroscio↗

Gravity Reception and Cardiac Function in the Spider

The following features of the arachnid gravity system were studied. (1) the absolute threshold to hyper-gz is quite low indicating fine proprioreceptive properties of the lyriform organ, the Gz/vibration detector; (2) the neurogenic heart of the spider is a good dependent variable for assessing its behavior to Gz and other stimuli which produce mechanical effects on the exoskeleton; (3) Not only is the cardiac response useful but it is now understood to be an integral part of the system which compensates for the consequences of gravity in the spider (an hydraulic leg extension); and (4) a theoretical model was proposed in which a mechanical amplifier, the leg lever, converts a weak force (at the tarsus) to a strong force (at the patella), capable of compressing the exoskeleton and consequently the lyriform receptor.

Finck, A.↗

RoboLab and virtual environments

A useful adjunct to the manned space station would be a self-contained free-flying laboratory (RoboLab). This laboratory would have a robot operated under telepresence from the space station or ground. Long duration experiments aboard RoboLab could be performed by astronauts or scientists using telepresence to operate equipment and perform experiments. Operating the lab by telepresence would eliminate the need for life support such as food, water and air. The robot would be capable of motion in three dimensions, have binocular vision TV cameras, and two arms with manipulators to simulate hands. The robot would move along a two-dimensional grid and have a rotating, telescoping periscope section for extension in the third dimension. The remote operator would wear a virtual reality type headset to allow the superposition of computer displays over the real-time video of the lab. The operators would wear exoskeleton type arms to facilitate the movement of objects and equipment operation. The combination of video displays, motion, and the exoskeleton arms would provide a high degree of telepresence, especially for novice users such as scientists doing short-term experiments. The RoboLab could be resupplied and samples removed on other space shuttle flights. A self-contained RoboLab module would be designed to fit within the cargo bay of the space shuttle. Different modules could be designed for specific applications, i.e., crystal-growing, medicine, life sciences, chemistry, etc. This paper describes a RoboLab simulation using virtual reality (VR). VR provides an ideal simulation of telepresence before the actual robot and laboratory modules are constructed. The easy simulation of different telepresence designs will produce a highly optimum design before construction rather than the more expensive and time consuming hardware changes afterwards.

Giarratano, Joseph C.↗

On-Command Force and Torque Impeding Devices (OC-FTID) Using ERF

Various machines have been developed to address the need for countermeasures of bone and muscle deterioration when humans operate over extended time in space. Even though these machines are in use, each of them has many limitations that need to be addressed in an effort to prepare for human missions to distant bodies in the solar system. An exercise exoskeleton was conceived that performs on-demand resistivity by inducing force and torque impedance via ElectroRheological Fluid (ERF). The resistive elements consist of pistons that are moving inside ERF-filled cylinders or a donut-shaped cavity, and the fluid flows through the piston when the piston is moved. Tests of the operation of ERF against load showed the feasibility of this approach. ERF properties of high yield stress, low current density, and fast response (less than one millisecond) offer essential characteristics for the construction of the exoskeleton. ERFs can apply very high electrically controlled resistive forces or torque while their size (weight and geometric parameters) can be very small. Their long life and ability to function in a wide temperature range (from -40 to 200 C) allows for their use in extreme environments. ERFs are also nonabrasive, non-toxic, and nonpolluting (meet health and safety regulations). The technology is applicable as a compact exercise machine for astronauts' countermeasure of microgravity, an exercise machine for sport, or as a device for rehabilitation of patients with limb issues.

Bar-Cohen, Yoseph↗

Anthropomorphic Telemanipulation System in Terminus Control Mode

This paper describes a prototype anthropomorphic kinesthetic telepresence system that is being developed at JPL. It utilizes dexterous terminus devices in the form of an exoskeleton force-sensing master glove worn by the operator and a replica four finger anthropomorphic slave hand. The newly developed master glove is integrated with our previously developed non-anthropomorphic six degree of freedom (DOF) universal force-reflecting hand controller (FRHC). The mechanical hand and forearm are mounted to an industrial robot (PUMA 560), replacing its standard forearm. The notion of 'terminus control mode' refers to the fact that only the terminus devices (glove and robot hand) are of anthropomorphic nature, and the master and slave arms are non-anthropomorphic. The system is currently being evaluated, focusing on tool handling and astronaut equivalent task executions. The evaluation revealed the system's potential for tool handling but it also became evident that hand tool manipulations and space operations require a dual arm robot. This paper describes the system's principal components, its control and computing architecture, discusses findings of the tool handling evaluation, and explains why common tool handling and EVA space tasks require dual arm robots.

glove exoskeleton force-sensing master glove EVA s↗

Supervisory control systems

The various functions of a computer are considered that serve in connecting the man, with his displays and controls, to an external environment, manipulator activators and the interoceptors that are in the actuators, and to the interosensors and the motors or the actuators to drive the sensors. Projected is an improved exoskeleton mechanism with computer control and some supervisory control that may give a quadriplegic the ability to walk and run around.

Sheridan, T. B.↗

Personnel occupied woven envelope robot

The Personnel Occupied Woven Envelope Robot (POWER) provides an alternative to extravehicular activity (EVA) of space suited astronauts and/or use of long slender manipulator arms such as are used in the Shuttle Remote Manipulator System. POWER provides the capability for a shirt sleeved astronaut to perform such work by entering a control pod through air locks at both ends of an inflated flexible bellows (access tunnel). The exoskeleton of the tunnel is a series of six degrees of freedom (Six-DOF) articulated links compressible to 1/6 of their fully extended length. The operator can maneuver the control pod to almost any location within about 50 m of the base attachment to the space station. POWER can be envisioned as a series of hollow Six-DOF manipulator segments or arms wherein each arm grasps the shoulder of the next arm. Inside the hollow arms ia a bellow-type access tunnel. The control pod is the fist of the series of linked hollow arms. The fingers of the fist are conventional manipulator arms under direct visual control of the nearby operator in the pod. The applications and progress to date of the POWER system is given.

Wessling, Francis↗