SEARCH · Search NASA
Results for “Experimental Results”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Bridging-Controlled Network Microstructure and Long-Wavelength Fluctuations in Silica-Poly(2-vinylpyridine) Nanocomposites: Experimental Results and Theoretical Analysis
Explore the source record for details and available documents.
First experimental results from lithium powder injection on ST40
First experimental results from the Lithium Evaporations to Advance PFCs in ST40 (LEAPS) program.
Opportunities to Update the Model of Tank Closure Grout Aging (SRNL-STI-2012-00404) Based on Experimental Results by the Savannah River Ecology Laboratory
The purpose of this report was to review the results of experiments on evolution of tank grout pore fluids performed by the Savannah River Ecology Laboratory (SREL) and reported in Seaman et al. (2020) and highlight opportunities for updating the model of tank grout degradation presented in Denham and Millings (2012). The SREL experimental results validate some assumptions used in the 2012 grout degradation model and provide information useful for updating the model. All experiments on tank grout degradation have limitations because of reaction rates and the enormous disparity between duration of the experiments and the duration of the degradation of the real tank grout system. Given these limitations, the experimental results form the basis for several recommendations for updating the grout degradation model described in this report.
A simple json format for storing and exchanging code calculation and experimental results
Calculation codes and code systems give their results in a plethora of different formats and/or files. For instance, MCNP gives a user the MCNP specific output file, the mctal file, the ptrac file, etc. while PARTISN has a PARTISN specific output file and a number of binary files with various kinds of information about the calculation. However, the results we are interested in are always the same. These can be single values such as the effective multiplication factor k eff or the effective delayed neutron fraction β eff . It can be histogram data (such as particle spectra, reaction rates, sensitivity profiles, etc.) or even pointwise data (for example the nuclide composition as a function of time, etc.). It is also worthwhile to note that this would also apply to experimental data that we may wish to compare with as well. Calculation and experimental results can basically be split into two components: attributes (or metadata) and the actual result itself. Attributes represent information about the result that are not necessarily required for its’ interpretation but that are still good to have. Often, these attributes are what we will want to filter results on. This means that these attributes are often the answer to specific questions we may have about the result. The following is a non exhaustive list of such basic questions: what type of result is it: e.g. the effective multiplication factor k eff , the effective delayed neutron fraction β eff , etc.; which case does it relate to: e.g. a specific ICSBEP case such as PU-MET-FAST-001-001; which code and version produced this result: e.g. MCNP 6.2, etc.; which nuclear data library was used to obtain the result: e.g. ENDF/B-VIII.0 or JEFF 3.3; which nuclide and reaction does it apply to (for reaction rates and sensitivity profiles); which volume in the geometry was it calculated in? The second component of the calculation or experimental result is the actual numerical data of the result. It is this data that we want to compare, exchange, plot, interpret, etc. It consists of values with optional uncertainties and units. It also includes the underlying structure (if any structure is required to interpret the result). Depending on the type of result, it may be a single value (e.g. the effective multiplication factor), an array of values (e.g. a reaction rate or particle spectrum) or even a multidimensional array. In order to exchange results between different organisations, for instance for benchmarking, people often resort to spreadsheets or custom text files that need to be filled out. While this approach works well if little information is to be exchanged, it can become cumbersome when dealing with large amounts of data (like for instance particle spectra for thousands of cases). In addition, such an approach does not always capture the metadata we may be interested in to allow for automated processing of these files. The purpose of this report is to propose a standardised json structure to store any type of result and present an associated python interface to interact with these results directly. For such a structure to be useful, it must fulfill a specific set of functional requirements that we try to meet with this proposal. The format must allow for the calculation result to stand by itself. This means that we should not have to look in multiple places to be able to understand it. For example, if the result relates to a particle spectrum, the group structure in which the result is given should be stored with it. The format should be code agnostic. This means that we do not need to know where it came from to understand it. The format should be result type agnostic. This means that the format must be generic enough so that we can even use it for results we have not thought of yet. The format should be relatively easy to interact with through different scripting or programming languages (i.e. the machine interface) while still providing a clean structure that can be used directly by any human.
Experimental results from the characterization of a 32-channels mixed-signal processor for the GAPS experiment
This work describes the experimental results obtained from the characterization of a 32-channels readout ASIC that is the core of a module composed by 4 Lithium-drifted Silicon, Si(Li), detectors. The module is the building block of a tracker in an upcoming balloon experiment. The activity is carried out within the General AntiParticle Spectrometer (GAPS) international collaboration, whose objective is the indirect detection of dark matter through the detection of antiparticles present in cosmic rays at low energies. The balloon flight is foreseen in 2024 from the McMurdo station in Antarctica. The ASIC is designed in a 180 nm CMOS technology and has 32 low-noise analog readout channels featuring a dynamic compression of the signal, an 11-bit SAR ADC, and a digital back-end section responsible for channel setting and for sending digital information to the data acquisition system of the tracker. This work has a twofold goal: it intends on the one hand to verify the performance of the circuit, on the other to select at least 300 good samples to be used for the assembly of the GAPS Si(Li) tracker.
Performance of microchannel plate based detectors for <25 keV x rays: Monte Carlo simulations and comparisons with experimental results
We present the results of Monte Carlo simulations of the microchannel plate (MCP) response to x rays in the 250 eV to 25 keV energy range as a function of both x-ray energy and impact angle and their comparisons with the experimental results from the X8A beamline at the National Synchrotron Light Source at Brookhaven National Laboratory. Incoming x rays interact with the lead glass of the microchannel plate, producing photoelectrons. Transport of the photoelectrons is neglected in this model, and it is assumed that photoelectrons deposit all their energy at the point they are created. This deposition leads to the generation of many secondary electrons, some fraction of which diffuse to the MCP pore surface where they can initiate secondary electron cascades in the pore under an external voltage bias. X-ray penetration through multiple MCP pore walls is increasingly important above 5 keV, and the effect of this penetration on MCP performance is studied. In agreement with past measurements, we find that the dependence of MCP sensitivity with angle relative to the pore bias changes from a cotangent dependence to angular independence and then proceeds to a secant dependence as the x-ray energy increases. We also find that with the increasing x-ray energy, the MCP gain sensitivity as a function of bias voltage decreases. The simulations also demonstrate that for x rays incident normal to the MCP surface, spatial resolution shows little dependence on the x-ray energy but degrades with the increasing x-ray energy as the angle of incidence relative to the surface normal increases. This agrees with experimental measurements. Simulation studies have also been completed for MCPs gated with a subnanosecond voltage pulse. In this work, we find that the optical gate profile width increases as the x-ray energy is increased above 5 keV, a consequence of increased x-ray penetration at energies >5 keV. Simulations of the pulsed dynamic range show that the dynamic range varies between ~100 and 1000 depending on x-ray energy and peak voltage.
Design and Preliminary Experimental Results on a Uniform-Field Test Fixture for Power Flow Experiments
Electrodes that produce a uniform electric field across their surfaces are desired for a variety of high-voltage systems including spark-gap switches and transversely excited atmospheric lasers. Here, the implementation of uniform-field electrodes to a parallel-plate load is described for the study of vacuum power flow under pulsed-power applications. We begin with an overview of general uniform-field geometries, and provide an open-source program that generates these geometries as described by Ernst. Following that, a modification to an existing power-flow experimental platform, that adopts a uniform-field geometry, is introduced and its utility is described. Lastly, preliminary experimental results are presented and future steps are outlined.
Experimental Results for an Inverter Integrated with A High-Speed Surface Permanent Magnet External Rotor Motor
This work presents the prototyping and testing of a high-speed outer rotor surface permanent magnet motor. The motor employs non-heavy rare-earth permanent magnets and operates at a rated speed of 6,666 rpm. In-slot ceramic heat exchangers are used to cool the windings. The external rotor configuration provides substantial space within the stator bore, which is used for power electronics integration. This integration introduces several design and thermal management challenges that are discussed in the paper. The machine has been prototyped and tested under various operating conditions, and both simulation and experimental results are presented.
Experimental results of a magnetically coupled piezoelectric actuator to relieve microchannel heat exchanger maldistribution
Refrigerant maldistribution is a common issue in microchannel heat exchangers. Refrigerant maldistribution can have significant negative effects on the heat transfer performance and increase the pressure drop, leading to increased superheat temperature at the outlet and increased compressor work, lowering system efficiency. In this work, a novel piezoelectric-driven magnetic actuator (PEDMA) was fabricated and inserted into the inlet header of the microchannel evaporator, with the goal of improving the non-uniformity of the flow distribution by regulating the flow in the header to the microchannels. Two prototype PEDMA designs were tested and showed significant impact on the refrigerant flow in the region of actuation. In the first design, the experimental data showed superheat reductions up to 9 °C when the individual channel temperatures were measured. The second design redistributed the refrigerant such that a 1% increase in capacity was calculated for the whole heat exchanger without significantly impacting the heating efficiency. The experimental results demonstrate the successful operation of the PEDMA devices and represent a new method of active flow distribution control which is based on a simple design with minimal additional energy consumption, and which can be inserted into microchannel heat exchanger headers to potentially relieve the refrigerant maldistribution.
Vapor liquid equilibrium of pure and aqueous Methyl diethanolamine (MDEA), 2-Dimethylmonoethanolamine (DMMEA), N-Methylmonoethanolamine (MMEA) and 1-(2-Aminoethyl)piperazine (AEP): Experimental results and modeling
This work presents new vapor-liquid data for the pure components 2-dimethylmonoethanolamine (DMMEA) and N-methylethanolamine (MMEA) and for the binary systems of aqueous methyldiethanolamine (MDEA), DMMEA, MMEA, and 1-(2-aminoethyl)piperazine (AEP). New Antoine models are developed for the pure component systems, and new and improved NRTL models for the binary systems. In the model development, together with new data from this work, all available data on VLE, excess heat of mixing, H E , freezing point depression, and specific heat were gathered, evaluated and used selectively for parameter optimization. Emphasis has been put on a best possible representation of amine volatility to enable reasonable predictions of amine emissions from absorption plants and to form a basis for subsequent models of ternary systems with CO 2 . In conclusion, model predictions are compared with experimental results and other models, source by source, and the overall results are satisfactory.
Report on High Energy Arcing Fault Experiments: Experimental Results from Open Box Enclosures
This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena. The experiments focus on providing data to better characterize the arc to improve the prediction of arc energy emitted during a HEAF event. An open box experiment allow for direct observation of the arc, which allows diagnostic instrumentation to record the phenomenological data needed for better characterization of the arc energy source term. The data collected supports characterization of the arc and arc jet, enclosure breach, material loss, and electrical properties. These results will be used to better characterizing the hazard for improvements in fire probabilistic risk assessment (PRA) realism. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the NRC, the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA Labs. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setup and execution. The HEAF experiments were performed between August 22, 2020 and September 18, 2020 on near-identical 51 cm (20 in) cube metal boxes suspended from a Unistrut support structure. The three-phase arcing fault was initiated at the ends of the conductors oriented vertically and located at the center of the box. Either aluminum or copper conductors were used for the conductors. The low-voltage experiments used 1 000 volts AC, while the medium-voltage experiments used 6 900 volts AC consistent with other recently completed experiments. Durations of the experiment ranged from 1 s to 5 s with fault currents ranging from 1 kA to 30 kA. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers, radiometers, and slug calorimeters at various locations around the electrical enclosures. The experiments were documented with normal and high-speed videography, infrared imaging and photography.
Report on High Energy Arcing Fault Experiments: Experimental Results from Low-Voltage Switchgear Enclosures
This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena for low-voltage metal enclosed switchgear containing aluminum conductors. This report covers full-scale laboratory experiments using representative nuclear power plant (NPP) three-phase electrical equipment. Electrical, thermal, and pressure data were recorded for each experiment and documented in this report. This report covers experiments performed on two low-voltage switchgear units with each unit consisting of two vertical sections. The data collected supports characterization of the low-voltage HEAF hazard and these results will be used to support potential improvements in fire probabilistic risk assessment (PRA) methods. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the NRC, the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setup and execution. The HEAF experiments were performed between August 26 and Augsut 29, 2019 on nearidentical Westinghouse Type DS low-voltage metal-enclosed indoor switchgear. The threephase arcing fault was initiated on the aluminum main bus or in select cases on the copper bus stabs near the breaker. These experiments used either nominal 480 volts AC or 600 volts AC. Durations of the experiments ranged from approximately 0.4 s to 8.3 s with fault currents ranging from approximately 9.2 kA to 19.3 kA. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers, radiometers, and slug calorimeters at various locations around the electrical enclosures. Environmental measurements of breakdown, conductivity and electromagnetics were also taken. The experiments were documented with normal and high-speed videography, infrared imaging and photography. The results, while limited, indicated the difficulty in maintaining and sustaining low-voltage arcs on aluminum components of sufficient duration and at a single point as observed operating experience.
Simulation and Experimental Results of Interdigital Capacitor (IDC) Sensors to Monitor Insulation Degradation of Cables
The efficacy of using interdigital capacitor (IDC) sensors to monitor cable insulation aging was studied through electromagnetic simulations and experimental measurements. Simulation results on both planar and conformal dielectric materials indicated that IDCs on thin substrates and with conducting backplanes provide superior performance in terms of higher capacitance. An airgap study showed that even a very small airgap between the sensor and the cable’s insulation results in significant reduction in capacitance; therefore, airgaps should be minimized. Finally, cables that underwent accelerated aging exposure in an oven were tested using fabricated IDC sensors. Measurement results showed a 12.5% increase in capacitance when the IDC was pressed against the insulation versus a 91.3% increase in capacitance when the IDC was pressed against the jackets of the cables for cable specimens ranging from unaged to aged 35 days.
Transient pulse‐based impedance characterisation of DC‐link capacitor for EV systems
In this study, a method for impedance characterisation of DC‐link capacitors based on transient pulse analysis is proposed. The fundamentals of the concept are presented and design considerations are discussed. The functionality of the proposed approach is supported by SPICE simulation with two different commercial capacitors from different manufacturers and validated with experimental results. Experimental results for equivalent series resistance, equivalent series inductance (ESL) and capacitance estimation are presented for commercial DC‐link capacitors and compared with component analyser results. The simulation and experimental results show that the proposed method is a promising candidate for capacitance and ESL estimation of capacitors in EV traction systems.
Validation and Verification for INL Modelica-based TEDS models Via Experimental Results
This report provides an overview on the verification and validation (V&V) of the Thermal Energy Distribution System (TEDS) model developed in the Modelica process modeling ecosystem using experimental data. Model development has led to the creation of a dynamic process model of the experimental TEDS facility housed within the Energy Systems Laboratory (ESL) at Idaho National Laboratory (INL). The model was then used during the preconstruction phase of the experimental effort to inform experimental design (e.g., insulation requirements, bypass line placement, expected performance of components) and to test innovative control schemes prior to the initial operation. The TEDS model developed in Modelica includes the primary components of the TEDS experimental unit: a 200kW Chromalox heater; a single-tank packed-bed thermal energy storage system filled with 0.125-inch alumina (Al2O3) beads; an ethylene-glycol-to-Therminol-66 heat exchanger; system piping; five control valves; and all associated temperature, pressure, and volumetric flow sensors. Using the Institute of Electrical and Electronics Engineers (IEEE) V&V methodologies, considered the gold standard in the engineering field, the model was verified using a combination of static analysis, spatial convergence, and regression tests. Then using dynamic time warping (DTW) initial runs to validate and tune the TEDS model versus the experiment were conducted. This tuning method was accomplished using the INL Risk Analysis Virtual ENvironment (RAVEN) software package. Tuning is required to account for physical phenomena that are less understood within the empirical heat transfer correlations. Through the commencement of this work, a systems-level model of TEDS with associated control systems, sensors, piping diameters, and component capabilities has been created. This model was utilized in the pre-experimental phase to inform system design, insulation thicknesses, and potential control schemes to operate the system effectively and safely. Then, initial experimental startup and operational data were used to demonstrate the validation and tuning methodology. This process demonstrates the classical two-step approach of a model informing experimental design followed by the experiment validation and tuning the model.
Experimental results of embedded phase change material capsules for increasing the performance of a wrapped heat pump water heater
Herein, to enhance the capacity of heat pump water heaters (HPWHs), high energy density phase change material (PCM) was used in two experimentally tested HPWH prototypes. Preliminary findings showed that in the PCM, stored thermal potential energy could be effectively converted into sensible heat in the water over a slight temperature difference, with the goal of increasing the capacity of hot water above a desired cut-off temperature. This exchange of energy results in an increased amount of hot water necessary for mixing at the location utilized by the consumer. It was also found that for a wrapped HPWH, there was an average increase of 27.7% in the capacity when 7.6 L of novel PCM filled spherical capsules were added to a 22.7 L tank downstream of the HPWH. In the second design (Beta), PCM capsules were immersed into the tank with a cylindrical geometry, and the UEF was increased by 5.5% over the baseline HPWH test result. As for the Beta design, heat loss was reduced significantly compared to a typical HPWH and the Alpha design. Food-grade PCMs were selected as appropriate. The novel encapsulation design increased the effective conductivity inside the capsule by adding metal fins.
Experimental results of wake steering using fixed angles
In this article, the authors present a test of wake steering at a commercial wind farm. A single fixed yaw offset, rather than an optimized offset schedule, is alternately applied to an upstream wind turbine, and the effect on downstream turbines is analyzed. This experimental design allows for comparison with engineering wake models independent of the controller's ability to track a varying offset and correctly measure wind direction. Additionally, by applying the same offset in beneficial and detrimental conditions, we are able to collect important data for assessing second-order wake model predictions. Results of the article from collected data show good agreement with the FLOw Redirection and Induction in Steady State (FLORIS) engineering model and offer support for the asymmetry of wake steering predicted by newer models, such as the Gauss–curl hybrid model.